Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Estud. av ; 27(77): 185-200, jan.-abr. 2013. ilus
Article in Portuguese | LILACS | ID: lil-696218

ABSTRACT

Neste artigo apresentamos as bases da Física das radiações, as fontes naturais e artificiais, os efeitos biológicos, a proteção radiológica. Examinamos também a sequência de eventos que resultou no acidente de Goiânia com uma fonte de césio-137 de um equipamento de radioterapia abandonado e suas terríveis consequências.


Subject(s)
Male , Female , Humans , Abnormalities, Radiation-Induced , Cosmic Radiation , Radiation Effects , Radiation Injuries , Radiation, Ionizing , Dose-Response Relationship, Radiation , Stochastic Processes , Technological Disasters
2.
Rev. panam. salud pública ; 30(4): 309-316, oct. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-606844

ABSTRACT

OBJETIVO: Medir a exposição de fisioterapeutas aos campos elétrico e magnético produzidos por 17 equipamentos de diatermia de ondas curtas (DOC) de clínicas de fisioterapia da cidade de Presidente Prudente, São Paulo, Brasil. Comparar os valores medidos com os níveis de exposição recomendados pelo ICNIRP (International Commission on Non-Ionizing Radiation Protection). Observar a eficácia das gaiolas de Faraday como medida de proteção à exposição dos fisioterapeutas aos campos elétrico e magnético oscilantes. MÉTODOS: As medidas dos campos elétrico e magnético foram realizadas durante sessões reais de tratamento fisioterápico, em quatro pontos: nas proximidades da pelve e da cabeça do operador, dos cabos elétricos dos aparelhos e dos eletrodos de aplicação. O equipamento de medição utilizado foi o EMR-200 da Wandell & Goltermann. RESULTADOS: Os valores obtidos nas proximidades dos eletrodos e cabos estavam de 10 a 30 vezes acima dos níveis de referência ocupacionais recomendados pela ICNIRP. Nas salas de tratamento com DOC com gaiola de Faraday, os campos encontrados foram ainda mais altos que os das salas sem esse revestimento, principalmente o campo magnético, com valores superiores a 100 vezes o limite de exposição da ICNIRP. CONCLUSÕES: As intensidades dos campos elétrico e magnético obtidas neste trabalho estão, de modo geral, acima dos níveis de exposição recomendados pelas normas da ICNIRP. Além disso observou-se que a gaiola de Faraday não fornece proteção aos fisioterapeutas mas aumenta os níveis de exposição aos quais estão submetidos estes profissionais.


OBJECTIVE: Measure physical therapists' exposure to the electric and magnetic fields produced by 17 shortwave diathermy devices in physical therapy clinics in the city of Presidente Prudente, São Paulo State, Brazil. Compare the observed values with the exposure levels recommended by the International Commission on Non-ionizing Radiation Protection (ICNIRP). Observe the efficacy of Faraday cages as a means of protecting physical therapists from exposure to oscillating electric and magnetic fields. METHODS: Electric and magnetic field measurements were taken at four points during actual physical therapy sessions: in proximity to the operator's pelvis and head, the devices' electrical cables, and the electrodes. The measuring equipment was a Wandel & Goltermann EMR-200. RESULTS: The values obtained in proximity to the electrodes and cables were 10 to 30 times higher than ICNIRP's recommended occupational reference levels. In the shortwave diathermy treatment rooms with Faraday cages, the fields were even higher than in treatment rooms not so equipped-principally the magnetic field, where the values were more than 100 times higher than the ICNIRP exposure limit. CONCLUSIONS: The electric and magnetic field intensities obtained in this study are generally above the exposure levels recommend in ICNIRP standards. It was also observed that the Faraday cage offers physical therapists no protection, and instead, increases their level of exposure.


Subject(s)
Humans , Electromagnetic Fields/adverse effects , Occupational Exposure/adverse effects , Physical Therapy Modalities , Radiation, Nonionizing/adverse effects , Short-Wave Therapy/adverse effects , Brazil , Diathermy/adverse effects , Health Knowledge, Attitudes, Practice , Occupational Health , Risk Assessment
3.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.459-460, graf.
Monography in Portuguese | LILACS | ID: lil-233818

ABSTRACT

É apresentada uma análise de dados de doses de trabalhadores que utlizaram simultaneamente 2 ou 3 monitores de radiação individuais em locais diferentes do corpo, durante alguns anos. Os resultados mostram que é importante o uso do avental e pescoceira de chumbo no setor de hemodinâmica, assim como a manipulação correta de fontes não seladas no setor de Medicina Nuclear (MN). No setor de hemodinâmica, as doses equivalentes máximas no pulso chegam a cerca de 10mSv/mês, enquanto que as doses equivalentes máximas sob avental e sob pescoceira de chumbo atingem 0,8mSv/mês.


Subject(s)
Protective Devices , Hemodynamics/physiology , Radiation Monitoring/instrumentation , Thermoluminescent Dosimetry/instrumentation , Lead/radiation effects
4.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.497-498, tab.
Monography in Portuguese | LILACS | ID: lil-233837

ABSTRACT

Em alguns endoscópicos específicos são realizadas radioescopias e radiografias com a equipe de médicos e enfermeiros próxima ao paciente. Através da simulação de exames e dosímetros termoluminescentes colocados em um fantoma antropomórfico foram determinadas as doses equivalentes em diferentes locais do corpo da pessoa que permanece na sala. Usando as normas nacionais e internacionais sobre os limites de dose recomendados foram calculados os números máximos de exames mensais e anuais recomendados às pessoas da equipe. Conclui-se que, com o uso de avental plumbífero, as altas doses equivalentes no cristalino (em média 1,67 mSv/exame) limitam o número de exames de que cada um pode participar.


Subject(s)
Thermoluminescent Dosimetry/instrumentation , Endoscopy/statistics & numerical data , Radiation Dosage , Radiography/statistics & numerical data , Eye Protective Devices , Radiation Exposure , Protective Clothing
5.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.499-500, graf.
Monography in Portuguese | LILACS | ID: lil-233838

ABSTRACT

Apresentamos os resultados iniciais do estudo das propriedades termoluminescentes do topázio brasileiro visando o uso para fins dosimétricos. Os dados obtidos até o presente momento indicam a viabilidade do uso do topázio como dosímetro na faixa de 20mGy a 20Gy.


Subject(s)
Thermoluminescent Dosimetry/instrumentation , Aluminum Silicates , Brazil , Radiation Dosage
SELECTION OF CITATIONS
SEARCH DETAIL