Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiology ; (12): E014-E014, 2020.
Article in Chinese | WPRIM | ID: wpr-811621

ABSTRACT

Objective@#In view of the difficulty of the shortage of new coronavirus nucleal acid test in the early COVID-19 outbreak, to explore the application value of chest CT in screening COVID-19 patients.@*Methods@#Retrospective analysis was performed on the data of patients with fever who received chest CT and new coronavirus nucleal acid test during January 25, 2020 to February 2, 2020 in Zhongnan Hospital of Wuhan University. A total of 587 patients were enrolled, including 290 males and 297 females, aged from 11.0 to 96.0 (51.3±17.1) years old. Take the nucleic acid test results as the gold standard, the sensitivity, specificity and rate of missed diagnosis of CT screening COVID-19 were calculated.@*Results@#Among the 587 patients, there were 433 positive cases (73.8%, 433/587) and 154 negative cases (26.2%, 154/587) of novel coronavirus nucleic acid test. Using CT screening, 494 cases (84.2%, 494/587) were positive and 93 cases (15.8%, 93/587) were negative. The sensitivity of CT screening COVID-19 was 97.7% (423/433), specificity was 53.9% (83/154) and rate of missed diagnosis was 2.3% (10/433).@*Conclusions@#In the early COVID-19 outbreak, CT screening has the advantages of high sensitivity and low rate of missed diagnosis of COVID-19, which can compensate for the shortage of new coronavirus nucleal acid test and can be used as the basis for rapid screening for early prevention and control of COVID-19 outbreak.

2.
Chinese Journal of Radiology ; (12): 430-434, 2020.
Article in Chinese | WPRIM | ID: wpr-868301

ABSTRACT

Objective:In view of the shortage of new coronavirus nucleal acid test in the early COVID-19 outbreak, the application value of chest CT in screening COVID-19 patients was explored.Methods:Retrospective analysis was performed on the data of patients with fever who received chest CT and new coronavirus nucleal acid test during January 25, 2020 to February 2, 2020 in Zhongnan Hospital of Wuhan University. A total of 587 patients were enrolled, including 290 males and 297 females, aged from 11.0 to 96.0 (51.3±17.1) years old. Taking the nucleic acid test results as the gold standard, the sensitivity, specificity and rate of misdiagnosis of CT screening were calculated.Results:Among the 587 patients, there were 433 positive cases (73.8%, 433/587) and 154 negative cases (26.2%, 154/587) of novel coronavirus nucleic acid test. Using CT screening, 494 cases (84.2%, 494/587) were positive and 93 cases (15.8%, 93/587) were negative. The sensitivity of CT screening was 97.7% (423/433), specificity was 53.9% (83/154) and rate of misdiagnosis was 2.3% (10/433).Conclusions:In the early COVID-19 outbreak, CT screening has the advantages of high sensitivity and low rate of misdiagnosis, which can compensate for the shortage of new coronavirus nucleal acid test and can be used as a rapid screening for early prevention and control.

SELECTION OF CITATIONS
SEARCH DETAIL