Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Article in Chinese | WPRIM | ID: wpr-1021553

ABSTRACT

BACKGROUND:Natural bone morphogenetic protein 2 disperses and degrades rapidly in vivo,reducing local concentration and therapeutic efficacy.Simply combining bone morphogenetic protein 2 with tissue engineering scaffolds could not stay in vivo for a long time,making it difficult to achieve good sustained and controlled release effects.OBJECTIVE:To prepare and test the biological properties and chondrogenic induction effect of collagen-binding domain-bone morphogenetic protein 2-collagen cartilage scaffold.METHODS:SD rat tail collagen was extracted and a collagen cartilage scaffold was prepared using a vacuum freeze-drying machine chemical crosslinking method.The plasmid expressing collagen-binding domain-bone morphogenetic protein 2 was constructed by rapid cloning C112 homologous recombination,constructed by genetic engineering,and introduced into E.coli,and then collagen-binding domain-bone morphogenetic protein 2 was isolated and purified.Natural bone morphogenetic protein 2 and collagen-binding domain-bone morphogenetic protein 2 were combined with collagen cartilage scaffolds,respectively,to detect the release level of bone morphogenetic protein 2 in the scaffolds.The biocompatibility of collagen-binding domain-bone morphogenetic protein 2-collagen cartilage scaffold was detected by CCK-8 assay and F-Actin staining.Bone marrow mesenchymal stem cells were implanted on two kinds of collagen cartilage scaffolds for chondrogenic induction,and their chondrogenic induction activity was tested.RESULTS AND CONCLUSION:(1)The binding rate of collagen-binding domain-bone morphogenetic protein 2 to collagen cartilage scaffolds was higher than that of natural bone morphogenetic protein 2(P<0.05).After being immersed in PBS for 7 days in vitro,the release of bone morphogenetic protein 2 in the collagen-binding domain bone morphogenetic protein 2-collagen cartilage scaffold was smaller than that in the natural bone morphogenetic protein 2-collagen cartilage scaffold(P<0.05).The results of the CCK-8 assay and F-Actin staining showed that the collagen-binding domain-bone morphogenetic protein 2-collagen cartilage scaffold had no obvious cytotoxicity and had good biocompatibility.(2)After 14 days of chondrogenic induction,ELISA detection demonstrated that the expressions of agglutincan and type Ⅱ collagen A1 in the collagen-binding domain-bone morphogenetic protein 2-collagen cartilage scaffold group were higher than those in the natural bone morphogenetic protein 2-collagen cartilage scaffold group(P<0.05).Under scanning electron microscopy,more bone marrow mesenchymal stem cells were observed on the inner wall of the pores of the two groups of scaffolds,and the cell morphology and size were the same,and the cells were closely arranged,without cell fragmentation or abnormal morphology.(3)The results indicate that the collagen-binding domain-bone morphogenetic protein 2-collagen cartilage scaffold has good biological properties and chondrogenic induction activity.

2.
Article in Chinese | WPRIM | ID: wpr-1021618

ABSTRACT

BACKGROUND:Digital three-dimensional reconstruction technology is gradually applied to orthopedic diseases with the advantages of visualization,accuracy and non-invasiveness,but there is less evidence-based support for its use in artificial hip hemiarthroplasty for intertrochanteric fractures of the femur in the elderly. OBJECTIVE:To investigate the application value and economic effects of digital three-dimensional reconstruction techniques in artificial hip hemiarthroplasty of intertrochanteric fractures of the femur in the elderly. METHODS:One hundred and thirty elderly patients with intertrochanteric femur fractures admitted to Zunyi First People's Hospital from January 2019 to December 2022 were selected and randomly divided into a control group(n=65)and an observation group(n=65).Artificial hip hemiarthroplasty was performed in both groups.The control group adopted the film template measurement method for manual preoperative planning while the observation group adopted a digital three-dimensional reconstruction technique.Preoperative planning and intraoperative actual application of prosthesis compliance rate,fibrinogen,D-dimer,bilateral femoral eccentric distance difference,bilateral lower limb length difference,Harris hip function score,visual analog scale score,excellent and good rate of hip function,complications,and hospitalization cost were observed in both groups. RESULTS AND CONCLUSION:(1)The proportion of acetabular side and femoral side prosthesis in grade 0(fully compliant)was higher in the observation group than that in the control group(P<0.05).(2)Fibrinogen and D-dimer levels in the observation group were lower than those in the control group 3 days after surgery(P<0.05).(3)The difference in bilateral femoral eccentric distance and the difference in bilateral lower limb length in the observation group were smaller than those in the control group immediately after surgery(P<0.05).The differences in Harris and visual analog scale scores were not significantly different between the two groups preoperatively,6 and 12 months postoperatively(P>0.05).There was no significant difference in excellent and good rate of hip function between the two groups 12 months postoperatively(P>0.05).(4)There was no significant difference in the complication rate between the two groups(P>0.05).The hospitalization cost of the observation group was higher than that of the control group(P<0.05).(5)It is indicated that digital three-dimensional reconstruction technology applied in artificial hip hemiarthroplasty of intertrochanteric femoral fracture in the elderly can not only accurately determine the prosthesis type before surgery,but also accurately reconstruct the bilateral lower limbs offline,but its hospitalization cost is high.

3.
Article in Chinese | WPRIM | ID: wpr-1009008

ABSTRACT

OBJECTIVE@#To explore effectiveness of positive support reduction and internal fixation in the treatment of femoral neck fractures.@*METHODS@#A clinical data of 74 patients with femoral neck fractures treated with hollow screw internal fixation between September 2017 and September 2021 was retrospectively analyzed. Based on the quality of fracture reduction, they were divided into positive support reduction group (group A, n=25), negative support reduction group (group B, n=21), and anatomical reduction group (group C, n=28). There was no significant difference in baseline data such as gender, age, cause of injury, disease duration, fracture side, Garden classification, and fracture line position classification between groups (P>0.05). The occurrence of complications such as early fixation failure, femoral neck shortening, non-union of fractures, and femoral head necrosis in three groups, as well as the Harris score of the hip joint were recorded and compared.@*RESULTS@#All patients had primary healing of incisions after operation and were followed up more than 12 months. The follow-up time for groups A, B, and C was (21.1±5.7), (22.6±4.3), and (21.9±4.1) months, respectively; there was no significant difference between groups (P>0.05). There was no significant difference in the incidences of non-union of fractures, early internal fixation failure, and the femoral head necrosis between groups (P>0.05). The incidence and length of femoral neck shortening, and the hip Harris score at last follow-up in groups A and C were all superior to those in the group B, with significant difference (P<0.05). There was no significant difference in the above indicators between groups A and C (P>0.05).@*CONCLUSION@#Positive support reduction can provide a good biomechanical environment for the healing of femoral neck fractures, thereby achieving a higher fracture healing rate, reducing the occurrence of femoral neck shortening, minimizing the function of hip joint, and achieving effectiveness similar to anatomical reduction.


Subject(s)
Humans , Femur Head Necrosis , Retrospective Studies , Femoral Neck Fractures/surgery , Femur Neck , Plastic Surgery Procedures
4.
Article in Chinese | WPRIM | ID: wpr-615394

ABSTRACT

BACKGROUND:Bone morphogenetic protein-2 (BMP-2) is a key to bone formation and repair.However,it has some disadvantages such as easy to lose and degrade and difficult to sustain continuous effect.OBJECTIVE:To study the preparation and properties of silk fibroin/chitosan/nano-hydroxyapatite (SF/CS/nHA) scaffold loading BMP-2.METHODS:After silk degumming,dissolution and purification,2% SF solution was obtained.BMP-2 was dissolved in 2% CS solution,and then fully mixed with equal volume of SF solution and proper amount of nHA.At last,the SF/CS/nHA scaffold loading BMP-2 was prepared using freeze-drying method as experimental group.The SF/CS/nHA scaffold was soaked in the BMP-2 solution as control group.The scaffold porosity was measured by Archimedes method,the surface morphology of the scaffold was observed by scanning electron microscope,the compressive strength was measured by universal testing machine.Scaffolds in the two groups were soaked in PBS,and the release of BMP-2 was measured by ELISA method at different time points.RESULTS AND CONCLUSION:(1) The scaffolds in the two groups had irregular porous structure,interconnected pores and uneven pore wall.There was no significant difference between the two groups in mean pore diameter,porosity and maximum compressive strength.(2) On the 1st day,the release rate of BMP-2 was 4.63% in the experimental group,and the release curve increased slowly.After 28 days,the release curve of BMP-2 was transferred to the plateau stage.But in the control group,the release rate of BMP-2 on the 1stday was 58.84%,and it was a significant initial burst release.The release curve increased rapidly,and was transferred to the platform stage on the 10th day.The release rate of BMP-2 release was significantly different between the two groups at days 1,2,4,10 (P < 0.05).These results show that the SF/CS/nHA scaffold loading BMP-2 could sustainably and slowly release BMP-2.

SELECTION OF CITATIONS
SEARCH DETAIL