Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Year range
1.
Chinese Medical Journal ; (24): 1401-1409, 2023.
Article in English | WPRIM | ID: wpr-980967

ABSTRACT

BACKGROUND@#There is still uncertainty regarding whether diabetes mellitus (DM) can adversely affect patients undergoing carotid endarterectomy (CEA) for carotid stenosis. The aim of the study was to assess the adverse impact of DM on patients with carotid stenosis treated by CEA.@*METHODS@#Eligible studies published between 1 January 2000 and 30 March 2023 were selected from the PubMed, EMBASE, Web of Science, CENTRAL, and ClinicalTrials databases. The short-term and long-term outcomes of major adverse events (MAEs), death, stroke, the composite outcomes of death/stroke, and myocardial infarction (MI) were collected to calculate the pooled effect sizes (ESs), 95% confidence intervals (CIs), and prevalence of adverse outcomes. Subgroup analysis by asymptomatic/symptomatic carotid stenosis and insulin/noninsulin-dependent DM was performed.@*RESULTS@#A total of 19 studies (n = 122,003) were included. Regarding the short-term outcomes, DM was associated with increased risks of MAEs (ES = 1.52, 95% CI: [1.15-2.01], prevalence = 5.1%), death/stroke (ES = 1.61, 95% CI: [1.13-2.28], prevalence = 2.3%), stroke (ES = 1.55, 95% CI: [1.16-1.55], prevalence = 3.5%), death (ES = 1.70, 95% CI: [1.25-2.31], prevalence =1.2%), and MI (ES = 1.52, 95% CI: [1.15-2.01], prevalence = 1.4%). DM was associated with increased risks of long-term MAEs (ES = 1.24, 95% CI: [1.04-1.49], prevalence = 12.2%). In the subgroup analysis, DM was associated with an increased risk of short-term MAEs, death/stroke, stroke, and MI in asymptomatic patients undergoing CEA and with only short-term MAEs in the symptomatic patients. Both insulin- and noninsulin-dependent DM patients had an increased risk of short-term and long-term MAEs, and insulin-dependent DM was also associated with the short-term risk of death/stroke, death, and MI.@*CONCLUSIONS@#In patients with carotid stenosis treated by CEA, DM is associated with short-term and long-term MAEs. DM may have a greater impact on adverse outcomes in asymptomatic patients after CEA. Insulin-dependent DM may have a more significant impact on post-CEA adverse outcomes than noninsulin-dependent DM. Whether DM management could reduce the risk of adverse outcomes after CEA requires further investigation.


Subject(s)
Humans , Endarterectomy, Carotid/adverse effects , Carotid Stenosis/surgery , Risk Factors , Treatment Outcome , Time Factors , Stents/adverse effects , Diabetes Mellitus, Type 2/complications , Diabetes Mellitus, Type 1 , Stroke/complications , Insulin/therapeutic use , Myocardial Infarction/complications , Risk Assessment
2.
Chinese Journal of Medical Instrumentation ; (6): 258-262, 2020.
Article in Chinese | WPRIM | ID: wpr-942739

ABSTRACT

Wireless technology has been widely used in medical devices and has brought convenience to medical care. However, wireless medical devices face risks such as data security and radio frequency interference. This study highlights safety and effectiveness evaluation of wireless medical devices, and discusses technical characteristics and regulation requirements, providing references for industry development and regulation.


Subject(s)
Computer Security , Wireless Technology
3.
Chinese Journal of Medical Instrumentation ; (6): 129-131, 2019.
Article in Chinese | WPRIM | ID: wpr-772546

ABSTRACT

Based on analysis of the domestic and foreign laws and regulations for hearing aids,some suggestions of safety evaluation about standards,premarket technical review and regulation are presented in this article.It is hoped to be helpful for registration and regulation of hearing aids.


Subject(s)
Equipment Safety , Hearing Aids
4.
Chinese Journal of Medical Instrumentation ; (6): 222-224, 2011.
Article in Chinese | WPRIM | ID: wpr-330477

ABSTRACT

This article describes the measure to decrease the emission of a domestic infusion pump which can't pass the radiated emission test when performing EMC tests. Then optimizes the measure and evaluates whether these measures affect the original electrical safety of the pump.


Subject(s)
Electricity , Infusion Pumps , Reference Standards , Quality Control , Safety Management
5.
Chinese Journal of Medical Instrumentation ; (6): 371-391, 2011.
Article in Chinese | WPRIM | ID: wpr-325978

ABSTRACT

In this paper we did some comparisons between YY0505-2005 and IEC 60601-1-2 edition2.1, and concluded that they are identical in respects of testing items and methods, but significantly different in respects of classification, essential performance and risk analysis. Some suggestions about the transformation and implementation of edition 2.1 standards in our country were proposed.


Subject(s)
Electricity , Electromagnetic Fields , Equipment and Supplies , Reference Standards , Reference Values
SELECTION OF CITATIONS
SEARCH DETAIL