Results 1 - 20 de 23
Filter
1.
Braz. dent. j ; 33(5): 108-115, Sep.-Oct. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1403780

ABSTRACT

Abstract Non-carious Cervical Lesions (NCCL) are dental tissue defects, non-related to caries, frequently observed in the dental practice. The aim of this study was to evaluate the effects of NCCL on dentin depth and thickness and the response to dental pain by means of clinical diagnostic tests. 86 teeth from 14 patients with NCCL were assessed by: depth of NCCL, clinical tests (evaporative stimulus, to detect pain levels of dentin hypersensitivity, cold thermal test to classify pulp health, percussive stimuli to evaluate the periradicular tissues and cone beam computed tomography (tomography to evaluate remaining dentin thickness (RDT). In terms of depth, the sample was divided into two groups: G1- teeth with NCCLs ≤1.0mm and G2- teeth with NCCLs between 1.1-2.0 mm. Dental pain data were compared by Mann-Whitney test and RDT by Student's t-test and correlations by the Pearson test (p<0.05). The depth of NCCL does not influence dental pain response to evaporative stimulus (p=0.129), cold thermal test (p = 0.125), vertical (p = 0.317) and horizontal (p = 0.119) percussion clinical diagnostic tests. However, G1 showed more RDT (p<0.001), and the correlation test showed that deeper NCCL presents smaller remaining dentin thickness (p=0.011/r=-0.273). In conclusion, tooth with NCCL up to 2mm-depth presents similar levels of pain for dentin hypersensitivity, pulp and periradicular tissue independent to NCCL depth, however, lesions with ≤1.0mm-depth showed greater RDT in tomographic findings.


Resumo Lesões Cervicais Não Cariosas (LCNC) são defeitos do tecido dentário, não relacionados à cárie, frequentemente observados na prática odontológica. O objetivo do estudo foi avaliar os efeitos da profundidade e espessura da dentina de LCNC na resposta à dor dentária por meio de testes de diagnóstico clínico. 86 dentes de 14 pacientes com LCNC foram avaliados por: profundidade da LCNC, testes clínicos (estímulo evaporativo, para detectar níveis de dor de hipersensibilidade dentinária, teste térmico frio para classificar a saúde pulpar, estímulos percussivos para avaliação do tecido perirradicular e tomografia computadorizada de feixe cônico (TCFC), para avaliação da espessura de dentina remanescente (EDR). Em termos de profundidade, a amostra foi dividida em dois grupos: G1- dentes com LCNCs ≤1,0mm e G2- dentes com LCNCs entre 1,1-2,0 mm. Os dados de dor dentária foram comparados pelo teste de Mann-Whitney e a EDR pelo teste t-Student e correlações pelo teste de Pearson (p <0,05). A profundidade da LCNC não influencia a resposta da dor dentária ao estímulo evaporativo (p = 0,129, teste térmico frio (p = 0,125), teste diagnóstico clínico de percussão vertical (p = 0,317) e horizontal (p = 0,119), porém o G1 apresentou maior EDR (p <0,001) e o teste de correlação mostrou que LCNC mais profunda apresenta menor EDR (p = 0,011 / r = -0,273). Conclusão: Dentes com LCNC de até 2mm de profundidade apresenta níveis semelhantes de dor para hipersensibilidade dentinária, pulpar e saúde perirradicular, independente da profundidade da LCNC. Entretanto, lesões com profundidade ≤1,0mmin apresentaram mais EDR nos achados tomográficos.

2.
Dental press j. orthod. (Impr.) ; 27(5): e2220325, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1404497

ABSTRACT

ABSTRACT Introduction: Many patients wearing orthodontic appliances request alterations in the shade of their teeth during orthodontic treatment. Objective: This study aimed to evaluate the efficacy of different products for bleaching and whitening under orthodontic brackets. Methods: Seventy bovine incisors were randomly divided into five groups (n = 14): C) non-whitening toothpaste (control); WTsi) hydrated silica whitening toothpaste; WThp) 2% hydrogen peroxide whitening toothpaste; OB) in-office bleaching; and HB) at-home bleaching. Two buccal surface areas were evaluated using the Easyshade spectrophotometer: under the metal bracket (experimental) and around the bracket (control). The paired t-test, ANOVA, and Tukey tests were applied for statistical analysis. Results: Intragroup comparisons showed that in groups C, WThp and HB, there were statistically significant differences in the enamel color changes (ΔEab) between under and around the bracket areas (C - under bracket = 7.97 ± 2.35, around bracket = 2.86 ± 0.81, p< 0.01; WThp - under bracket = 4.69 ± 2.98, around bracket = 2.05 ± 1.41, p< 0.01; HB - under bracket = 7.41 ± 2.89, around bracket: 9.86 ± 3.32, p= 0.02). Groups WTsi, OB and HB presented similar perception of tooth whiteness (ΔWID) between the tested areas. Intergroup comparisons demonstrated that under the bracket area, the color change (ΔEab) was similar for all groups, except WThp (C = 7.97 ± 2.35; WTsi = 8.54 ± 3.63; WThp = 4.69 ± 2.98; OB = 9.31 ± 4.32; HB = 7.41 ± 2.89; p< 0.01). Conclusions: The dental color changes were effective for the products tested in groups WTsi, OB and HB in the presence of metallic orthodontic brackets.


RESUMO Introdução: Durante o tratamento ortodôntico, muitos pacientes solicitam, também, alteração na cor dos seus dentes. Objetivo: O presente estudo avaliou diferentes produtos clareadores e branqueadores, quanto à sua eficácia sob os braquetes ortodônticos. Métodos: 70 incisivos bovinos foram aleatoriamente divididos em cinco grupos (n = 14): C) dentifrício não branqueador (controle); WTsi) dentifrício branqueador com sílica hidratada; WThp) dentifrício branqueador com peróxido de hidrogênio a 2%; OB) clareamento no consultório e HB) clareamento caseiro. Usando um espectrofotômetro Easyshade, foram avaliadas duas áreas na superfície vestibular dos dentes: sob o braquete (experimental) e ao redor do braquete (controle). Para análise estatística, foram usados os testest pareado, ANOVA e Tukey. Resultados: As comparações intragrupos demonstraram que, nos grupos C, WThp e HB, ocorreram diferenças estatisticamente significativas nas alterações de cor do esmalte (ΔEab) entre as áreas sob o braquete e ao redor do braquete (C: sob o braquete = 7,97 ± 2,35, ao redor do braquete = 2,86 ± 0,81, p< 0,01; WThp: sob o braquete = 4,69 ± 2,98, ao redor do braquete = 2,05 ± 1,41, p< 0,01; HB: sob o braquete = 7,41 ± 2,89, ao redor do braquete = 9,86 ± 3,32, p= 0,02). Os grupos WTsi, OB e HB demonstraram semelhanças na percepção do clareamento (ΔWID) entre as áreas avaliadas. As comparações intergrupos demonstraram que, nas áreas sob os braquetes, as alterações de cor (ΔEab) foram semelhantes para os grupos, com exceção do WThp (C = 7,97 ± 2,35; WTsi = 8,54 ± 3,63; WThp = 4,69 ± 2,98; OB = 9,31 ± 4,32; HB = 7,41 ± 2,89; p< 0,01). Conclusões: As alterações na cor dos dentes foram efetivas para os procedimentos testados nos grupos WTsi, OB e HB na presença de braquetes metálicos ortodônticos.

3.
Braz. oral res. (Online) ; 36: e006, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1355933

ABSTRACT

Abstract The aim of this scoping review was to provide sufficient information about the effectiveness of ozone gas in virus inactivation of surfaces and objects under different environmental conditions. The review was performed according to the list of PRISMA SrC recommendations and the JBI Manual for Evidence Synthesis for Scoping Reviews. The review was registered in Open Science Framework (OSF). EMBASE (Ovid), Lilacs, LIVIVO, MEDLINE (PubMed), SciELO, Scopus and Web of Science were primary sources, and "gray literature" was searched in OpenGray and OpenThesis. A study was included if it reported primary data on the effect of ozone gas application for vehicle-borne and airborne virus inactivation. No language or publication date restriction was applied. The search was conduct on July 1, 2020. A total of 16,120 studies were screened, and after exclusion of noneligible studies, fifteen studies fulfilled all selection criteria. Application of ozone gas varied in terms of concentration, ozone exposure period and the devices used to generate ozone gas. Twelve studies showed positive results for inactivation of different virus types, including bacteriophages, SARS-CoV-2 surrogates and other vehicle-borne viruses. Most of the studies were classified as unclear regarding sponsorship status. Although most of the population has not yet been vaccinated against COVID-19, disinfection of environments, surfaces, and objects is an essential prevention strategy to control the spread of this disease. The results of this Scoping Review demonstrate that ozone gas is promising for viral disinfection of surfaces.

4.
Braz. dent. j ; 32(4): 19-30, July-Aug. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1345519

ABSTRACT

Abstract: This study investigated the bleaching effectiveness and the physicochemical effects on enamel of violet light and ozone, associate or not to hydrogen peroxide, compared to 35%-hydrogen peroxide. Enamel-dentin blocks from human molars were randomly allocated to receive one of the following bleaching protocols (n=15): (HP) 35%-hydrogen peroxide, (VL) violet light, (OZ) ozone, the association between hydrogen peroxide with ozone (OZ+HP) or violet light (VL+HP). All protocols were performed in two sessions with a 48h interval. Color (spectrophotometer) and mineral composition (Raman spectroscopy) were measured before and after the bleaching. Color changes were calculated by ΔEab, ΔE00, and whitening index (WI). The surface roughness was measured with an atomic force microscope. Data were analyzed by One-way or Two-way repeated measure ANOVA followed by the Tukey's test (α = 0.05). The lowest color change values (either measured by WI, ΔEab, or ΔE00) were observed for VL and OZ used with no HP. Violet light associate with HP was unable to improve the color changes observed for the peroxide alone, in combination with OZ and HP, the highest color changes were verified. Regardless of bleaching protocol, the bleached enamel presented higher contents of PO4 and CO3 -2 than those observed at baseline. All bleaching protocols resulted in similar enamel surface roughness. Both the VL and the OZ caused reduced effects on the enamel color change when used alone. The ozone therapy improved the bleaching effect in the group that received the association of HP.


Resumo O objetivo deste estudo foi avaliar o efeito clareador e físico-químico no esmalte de luz violeta e ozônio, associado ou não ao peróxido de hidrogênio, comparado a 35% de peróxido de hidrogênio. Blocos de esmalte-dentina de molares humanos foram alocados aleatoriamente para receber um dos seguintes protocolos de clareamento (n = 15): (HP) peróxido de hidrogênio a 35%, (VL) luz violeta, (OZ) ozônio, a associação entre peróxido de hidrogênio com ozônio (HP+OZ) ou luz violeta (HP+VL). Todos os protocolos foram realizados em duas sessões, com intervalo de 48 horas entre eles. A cor (espectrofotômetro) e a composição mineral (espectroscopia Raman) do dente foram medidas antes e após os procedimentos de clareamento. As alterações de cor foram calculadas por ΔEab e ΔE00, e o índice de brancura foram calculados. A rugosidade da superfície das amostras clareadas foi medida por microscópio de força atômica. Os dados foram analisados por ANOVA One way ou ANOVA two way de medidas repetidas seguida pelo teste de Tukey (α = 0,05). Os menores valores de alterações de cor (medidos por WI, ΔEab ou ΔE00) foram observados para VL e OZ usados na ausência de HP. VL associada ao HP não foi capaz de melhorar as alterações de cor observadas com o uso do HP, mas a combinação de OZ e HP produz as maiores alterações de cor. Independentemente do protocolo de clareamento, o esmalte clareado apresentou maiores teores de PO4 e CO3 -2 do que os observados inicialmente. Não foi observada diferença significativa entre os protocolos de clareamento testados em relação à rugosidade da superfície do esmalte. É possível concluir que a VL ou o OZ tiveram efeitos reduzidos na mudança de cor do esmalte quando usados sozinhos. A terapia com OZ melhorou o efeito clareador do HP.


Subject(s)
Humans , Ozone , Tooth Bleaching , Tooth Bleaching Agents , Color , Dental Enamel , Hydrogen Peroxide
5.
Article | IMSEAR | ID: sea-210674

ABSTRACT

Ocular toxoplasmosis is caused by Toxoplasma gondii, inducing retinochoroiditis. It is the leading cause of infectiousposterior uveitis worldwide. Its treatment is based on oral drug administration. However, the blood–ocular barriersystems make the penetration of therapeutic drug concentrations within the eye difficult, limiting the effectiveness oftreatments. In this context, ocular drug delivery systems represent therapeutic alternative for the treatment of oculartoxoplasmosis. In this study, a review of clinical manifestations, diagnosis, treatment, and perspectives regardingthe treatment of ocular toxoplasmosis was conducted. A search was carried out on ScienceDirect, Scopus, Webof Science, PubMed, and SciELO, and the following keywords were used: toxoplasmosis, ocular toxoplasmosis,toxoplasmic retinochoroiditis, and congenital toxoplasmosis; and Boolean operators, associated with other keywords,such as epidemiology, ocular toxoplasmosis diagnosis, ocular toxoplasmosis treatment, and ocular toxoplasmosisperspectives, were applied. In conclusion, ocular toxoplasmosis still lacks effective treatment. Therefore, it is essentialto develop new molecules and/or new drug delivery systems capable of releasing therapeutic doses of anti-Toxoplasmadrugs directly in the posterior segment of the eye, for an extended period, since complications resulting from thedisease may shorten the productive life of individuals and may even lead to blindness

6.
Braz. dent. j ; 28(5): 624-631, Sept.-Oct. 2017. tab, graf
Article in English | LILACS | ID: biblio-888690

ABSTRACT

Abstract The aim of this study was to evaluate the degree of conversion, color stability, chemical composition, and bond strength of a light-cured resin cement contaminated with three different hemostatic solutions. Specimens were prepared for the control (uncontaminated resin cement) and experimental groups (resin cement contaminated with one of the hemostatic solutions) according to the tests. For degree of conversion, DC (n = 5) and color analyses (n = 10), specimens (3 mm in diameter and 2 mm thick) were evaluated by Fourier transform infrared spectroscopy (FTIR) and CIELAB spectrophotometry (L*, a*, b*), respectively. For elemental chemical analysis (n = 1), specimens (2 mm thick and 6 mm in diameter) were evaluated by x-ray energy-dispersive spectroscopy (EDS). The bond strengths of the groups were assessed by the microshear test (n = 20) in a leucite-reinforced glass ceramic substrate, followed by failure mode analysis by scanning electron microscopy (SEM). The mean values, except for the elemental chemical evaluation and failure mode, were evaluated by ANOVA and Tukey's HSD test. The color stability was influenced by storage time (p<0.001) and interaction between contamination and storage time (p<0.001). Hemostop and Viscostat Clear contamination did not affect the DC, however Viscostat increased the DC. Bond strength of the resin cement to ceramic was negatively affected by the contaminants (p<0.001). Contamination by hemostatic agents affected the bond strength, degree of conversion, and color stability of the light-cured resin cement tested.


Resumo O objetivo desse estudo foi avaliar o grau de conversão, estabilidade de cor, composição química e resistência de união de um cimento resinoso fotoativado contaminado com três soluções hemostáticas diferentes. Foram preparadas amostras para o grupo controle (cimento não contaminado) e grupos experimentais (cimento contaminado com uma das soluções hemostáticas) de acordo com os testes. Para o grau de conversão e análise de cor (n=10), as amostras (3 mm de diâmetro e 2 mm de espessura) foram avaliadas por espectroscopia de infravermelho com transformação de Fourier (FTIR) e espectrofotometria CIELAB (L*, A*, B*), respectivamente. Para a análise química elementar (n=1), os espécimes (2 mm de espessura e 6 mm de diâmetro) foram avaliados por espectroscopia de energia dispersiva de raios-x (EDS). As resistências de união dos grupos foram avaliadas pelo ensaio de microcisalhamento (n=20) em um substrato cerâmico de vidro reforçado com leucita, seguida da análise de modo de falha por microscopia eletrônica de varredura (MEV). Os valores médios, com exceção da avaliação química e do modo de falha, foram avaliados por ANOVA e pelo teste de Tukey. A estabilidade de cor foi influenciada pelo tempo de armazenagem (p<0,001) e interação entre a contaminação e o tempo (p<0,001). A contaminação pelo Hemostop e Viscostat Clear não influenciaram no GC, porém a contaminação com Viscostat aumentou o GC. A resistência de união do cimento a cerâmica foi negativamente afetada pelos contaminantes (p<0,001). A contaminação por agentes hemostáticos afetou a resistência de união, o grau de conversão e a estabilidade de cor do cimento resinoso fotoativado testado.


Subject(s)
Hemostatics , Resin Cements/chemistry , Color , Microscopy, Electron, Scanning , Solutions , Spectrum Analysis , Surface Properties
7.
Braz. dent. j ; 28(3): 362-371, May-June 2017. tab, graf
Article in English | LILACS | ID: biblio-888649

ABSTRACT

Abstract This study measured the radiant power (mW), irradiance (mW/cm2) and emission spectra (mW/cm2/nm) of 22 new, or almost new, light curing units (LCUs): - Alt Lux II, BioLux Standard, Bluephase G2, Curing Light XL 3000, Demetron LC, DX Turbo LED 1200, EC450, EC500, Emitter C, Emitter D, KON-LUX, LED 3M ESPE, Led Lux II, Optilight Color, Optilight Max, Optilux 501, Poly Wireless, Radii cal, Radii plus, TL-01, VALO Cordless. These LCUs were either monowave or multiple peak light emitting diode (LED) units or quartz-tungsten-halogen LCUs used in anterior and posterior teeth. The radiant power emitted by the LCUs was measured by a laboratory grade laser power meter. The tip area (cm²) of the LCUs was measured and used to calculate the irradiance from the measured radiant power source. The MARC-Patient Simulator (MARC-PS) with a laboratory grade spectrometer (USB4000, Ocean Optics) was used to measure the irradiance and emission spectrum from each LCU three times at the sensor located on the facial of the maxillary central incisors and then separately at the occlusal of a maxillary second molar. The minimum acceptable irradiance level was set as 500 mW/cm2. Irradiance data was analyzed using two-way ANOVA and the radiant power data was analyzed by one-way ANOVA followed by Tukey test (a=0.05). In general, the irradiance was reduced at the molar tooth for most LCUs. Only the Valo, Bluephase G2 and Radii Plus delivered an irradiance similar to the anterior and posterior sensors greater than 500 mW/cm2. KON-LUX, Altlux II, Biolux Standard, TL-01, Optilux 501, DX Turbo LED 1200 LCUs delivered lower irradiance values than the recommended one used in molar region, KON-LUX and Altlux II LCUs used at the maxillary incisors. Bluephase G2 and Optilight Max delivered the highest radiant power and KON-LUX, Altlux II and Biolux Standard delivered the lowest power. The emission spectrum from the various monowave LED LCUs varied greatly. The multi-peak LCUs delivered similar emission spectra to both sensors.


Resumo Este estudo mediu a potência (mW), irradiância (mW/cm2) e espectro da luz (mW/cm2/nm) emitida por 22 fontes de luz (Alt Lux II, BioLux Standard, Bluephase G2, Curing Light XL 3000, Demetron LC, DX Turbo LED 1200, EC450, EC500, Emitter C, Emitter D, KON-LUX, LED 3M ESPE, Led Lux II, Optilight Color, Optilight Max, Optilux 501, Poly Wireless, Radii cal, Radii plus, TL-01, VALO Cordless) disponíveis comercialmente. A potência emitida pelas fontes de luz foi medida usando um medidor laboratorial de potencia com grade a laser. A área (cm²) da ponta ativa efetiva das fontes de luz foi medida com paquímetro digital e utilizada para calcular a irradiância emitida. O simulador de paciente-MARC (MARC - PS) com espectrómetro (USB4000, Ocean Optics) foi usado para medir a irradiância e o espectro de luz emitida por cada fonte de luz na região anterior e posterior. Esta medição foi repetida por três vezes em dois sensores localizados na região anterior e posterior da arcada dentária. Os dados de irradiância foram analisados utilizando análise de variância em dois fatores, e os dados de potência foram analisados com análise de variância em fator único seguido pelo teste de Tukey (a=0,05). As fontes de luz Valo, Bluephase G2, Radii Plus emitiram irradiância semelhante tanto na região anterior como posterior com valores superiores ao mínimo de 500 mW/cm2. Seis fontes de luz emitiram irradiância menor que o recomendado (500 mW/cm2) quando usadas na região posterior: Kon-lux, Altlux II, Biolux Standard TL-01, Optilux 501, DX Turbo LED 1200 e duas quando usadas na região anterior: Kon-lux e Altlux II LCUs. As fontes Bluephase G2, Optilight Max emitiram os maiores valores de potência e as fontes de luz Altlux II e Biolux Standard emitiram os menores valores de potência. O espectro de luz das fontes LED de espectro único variou de forma evidente entre as fontes. As fontes LED multi pico de espectro emitiram espectros de luz similar para ambos os sensores. A fotoativação na região posterior tende a reduzir substancialmente a irradiância da maioria das fontes de luzes testadas.


Subject(s)
Humans , Curing Lights, Dental , Dental Restoration, Permanent , Lasers , Patient Simulation , Spectrum Analysis/instrumentation , Tooth/radiation effects
8.
Braz. oral res. (Online) ; 30(1): e3, 2016. tab, graf
Article in English | LILACS | ID: lil-768254

ABSTRACT

We analyzed the effect of the crosshead speed of an applied load on failure load and failure mode of restored human premolars. Fifty intact, noncarious human premolars were selected. Class II mesio-occlusodistal preparations were made with a water-cooled high-speed preparation machine, and the teeth were restored with composite resin. The specimens were divided into five groups (n = 10 each) and tested individually in a mechanical testing machine, in which a 6.0-mm-diameter steel cylinder was mounted to vary the crosshead speed: v0.5: 0.5 mm/min; v1: 1.0 mm/min; v2.5: 2.5 mm/min; v5: 5.0 mm/min; and v10: 10.0 mm/min. The cylinder contacted the facial and lingual ridges beyond the margins of the restorations. Peak load to fracture was measured for each specimen (N). The means were calculated and analyzed with one-way analysis of variance followed by Tukey's test (a = 0.05). The mean load at failure values were (N) as follows: v0.5, 769.4 ± 174.8; v1, 645.2 ± 115.7; v5, 614.3 ± 126.0; v2.5, 609.2 ± 208.1; and v10, 432.5 ± 136.9. The fracture modes were recorded on the basis of the degree of the tooth structural and restorative damage: (I) fracture of the restoration involving a small portion of the tooth; (II) fractures involving the coronal portion of the tooth with cohesive failure of the composite resin; (III) oblique tooth and restoration fracture with periodontal involvement; and (IV) vertical root and coronal fracture. Varying crosshead speeds of 0.5–5.0 mm/min did not influence the failure load of restored maxillary premolars; however, increasing the crosshead speed to 10 mm/min decreased the failure load values and the degree of tooth structural damage.


Subject(s)
Humans , Bicuspid , Dental Restoration Failure , Dental Restoration, Permanent/methods , Tooth Fractures/etiology , Analysis of Variance , Biomechanical Phenomena , Composite Resins/chemistry , Dental Stress Analysis , Dental Cavity Preparation/methods , Dental Restoration, Permanent/instrumentation , Random Allocation , Reference Values , Statistics, Nonparametric , Stress, Mechanical , Tensile Strength , Time Factors
9.
Braz. dent. j ; 25(4): 327-331, 2014. tab, graf
Article in English | LILACS | ID: lil-722604

ABSTRACT

The aim of this study was to evaluate the microtensile bond strength (µTBS) of two substrates (enamel and dentin) considering two study factors: type of composite resin [methacrylate-based (Filtek Supreme) or silorane-based (Filtek LS)] and aging time (24 h or 3 months). Twenty human molars were selected and divided into 2 groups (n=10) considering two dental substrates, enamel or dentin. The enamel and dentin of each tooth was divided into two halves separated by a glass plate. Each tooth was restored using both tested composite resins following the manufacturer's instructions. The samples were sectioned, producing 4 sticks for each composite resin. Half of them were tested after 24 h and half after 3 months. µTBS testing was carried out at 0.05 mm/s. Data were analyzed by three-way ANOVA and Tukey's HSD tests at α=0.05. Significant differences between composite resins and substrates were found (p<0.05), but no statistically significant difference was found for aging time and interactions among study factors. The methacrylate-based resin showed higher µTBS than the silorane-based resin. The µTBS for enamel was significantly higher than for dentin, irrespective of the composite resin and storage time. Three months of storage was not sufficient time to cause degradation of the bonding interaction of either of the composite resins to enamel and dentin.


O objetivo deste estudo foi avaliar a resistência adesiva por meio do teste de microtração (µTBS) entre dois substratos (esmalte e dentina) considerando dois fatores em estudo: Tipo de resina [metacrilato (Filtek Supreme) ou silorano (Filtek LS)] e tempo de envelhecimento (24 horas ou 3 meses). Vinte molares humanos foram selecionados e divididos em dois grupos (n=10) considerando dois substratos dentários, esmalte e dentina. O esmalte e a dentina de cada dente foram divididos em duas metades, por meio de uma lamínula. Cada dente foi restaurado usando ambas as resinas testadas, seguindo instruções do fabricante. As amostras foram seccionadas, resultando em quatro palitos para cada tipo de resina. Metade dos palitos foi testada após 24h e o restante após três meses. O ensaio de microtração (µTBS) foi conduzido numa velocidade de 0,05 mm/s. Os dados foram analisados usando three-way ANOVA e teste de Tukey HSD (α= 0,05). Diferença significante foi encontrada para o fator resina e substratos (p<0,05), porém não houve influência do tempo de envelhecimento e interações entre fatores estudados. A resina à base de metacrilato apresentou maior resistência adesiva do que a silorano. A adesão em esmalte foi significativamente maior do que em dentina, independente da resina e do tempo de envelhecimento. Três meses de armazenamento não foram suficientes para causar degradação da interação adesiva, para ambas as resinas compostas, no esmalte e na dentina.


Subject(s)
Humans , Dental Enamel , Dentin , Methacrylates , Silorane Resins , Tensile Strength , In Vitro Techniques
10.
Braz. dent. j ; 23(5): 484-489, Sept.-Oct. 2012. ilus, graf, tab
Article in English | LILACS | ID: lil-660348

ABSTRACT

This in vitro study analyzed the effect of different load application devices on fracture resistance and failure mode of maxillary premolars restored with composite resin. Sixty human maxillary premolars received standardized mesio-occluso-distal cavity preparations and were restored with composite resin. The specimens were randomly divided into 6 groups (n=10). Compressive loading was applied using 6 different metallic devices: S2: 2-mm sphere; S6: 6-mm sphere; C2: 2-mm cylinder; C6: 6-mm cylinder; WS: wedge shape device; and MAT: individualized metallic antagonist tooth. Data were analyzed statistically using one-way ANOVA and Tukey's test (α=0.05). The failure mode was recorded based on the 4 sequential levels. Statistical analysis revealed that WS presented significantly higher fracture resistance than S6 and C6. No significant difference was found among MAT, C2, S2 and S6. Sphere and cylinder with 6 mm were similar, with the lowest values of all groups. MAT presented the least number of catastrophic failures while C2, S2 and WS presented the highest. The type of load application device influences significantly the behavior of the teeth-restoration complex during mechanical fracture resistance test.


Este estudo avaliou o efeito de diferentes tipos de dispositivos de aplicação de carga na resistência à fratura de pré-molares superiores restaurados com resina composta. Sessenta pré-molares humanos receberam preparo mésio-ocluso-distal padronizado e as cavidades foram restauradas com resina composta. As amostras foram aleatoriamente divididas em 6 grupos (n=10). Carregamento de compressão foi realizado usando seis diferentes dispositivos metálicos de aplicação de carga: S2 e S6: esfera de 2 mm e 6 mm de diâmetro respectivamente; C2 e C6: cilindro de 2 mm e 6 mm de diâmetro respectivamente; WS: lâmina de faca e MAT: antagonista individualizado em metal. Os resultados foram submetidos à análise de variância e teste de Tukey (p<0,05). O modo de falha foi classificado em 4 níveis e estão apresentado em porcentagem. O dispositivo WS resultou em maior resistência a fratura de pré-molares que S6 e C6. Não houve diferença estatística entre os grupos MAT, C2, S2 e S6. Menor resistência foi verificada com o uso de S6 e C6. O dispositivo MAT resultou em menor número de falhas catastróficas enquanto nos grupos C2, S2 e WS essas falhas foram significativas. O tipo de dispositivo de aplicação de carga influenciou significativamente no comportamento do complexo dente-restauração durante o teste de resistência à fratura.


Subject(s)
Humans , Composite Resins/chemistry , Dental Restoration, Permanent , Equipment Failure Analysis/instrumentation , Materials Testing/instrumentation , Tooth Fractures , Analysis of Variance , Bicuspid , Equipment Failure Analysis/methods
SELECTION OF CITATIONS
SEARCH DETAIL