Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Korean Neurosurgical Society ; : 572-581, 2022.
Article in English | WPRIM | ID: wpr-938087

ABSTRACT

Objective@#: Compared to microscopes, exoscopes have advantages in field-depth, ergonomics, and educational value. Exoscopes are especially well-poised for adaptation into fluorescence-guided surgery (FGS) due to their excitation source, light path, and image processing capabilities. We evaluated the feasibility of near-infrared FGS using a 3-dimensional (3D), 4 K exoscope with nearinfrared fluorescence imaging capability. We then compared it to the most sensitive, commercially-available near-infrared exoscope system (3D and 960 p). In-vitro and intraoperative comparisons were performed. @*Methods@#: Serial dilutions of indocyanine-green (1–2000 μg/mL) were imaged with the 3D, 4 K Olympus Orbeye (system 1) and the 3D, 960 p VisionSense Iridium (system 2). Near-infrared sensitivity was calculated using signal-to-background ratios (SBRs). In addition, three patients with brain tumors were administered indocyanine-green and imaged with system 1, with two also imaged with system 2 for comparison. @*Results@#: Systems 1 and 2 detected near-infrared fluorescence from indocyanine green concentrations of >250 μg/L and >31.3 μg/L, respectively. Intraoperatively, system 1 visualized strong near-infrared fluorescence from two, strongly gadoliniumenhancing meningiomas (SBR=2.4, 1.7). The high-resolution, bright images were sufficient for the surgeon to appreciate the underlying anatomy in the near-infrared mode. However, system 1 was not able to visualize fluorescence from a weakly-enhancing intraparenchymal metastasis. In contrast, system 2 successfully visualized both the meningioma and the metastasis but lacked high resolution stereopsis. @*Conclusion@#: Three-dimensional exoscope systems provide an alternative visualization platform for both standard microsurgery and near-infrared fluorescent guided surgery. However, when tumor fluorescence is weak (i.e., low fluorophore uptake, deep tumors), highly sensitive near-infrared visualization systems may be required.

2.
Journal of Korean Neurosurgical Society ; : 389-397, 2019.
Article in English | WPRIM | ID: wpr-788795

ABSTRACT

OBJECTIVE: Mechanical thrombectomies with balloon-guide catheters (BGC) are thought to improve successful recanalization rates and to decrease the incidence of distal emboli compared to thrombectomies without BGC. We aimed to assess the effects of BGC on the outcomes of mechanical thrombectomy in acute ischemic strokes.METHODS: Studies from PubMed, EMBASE, and the Cochrane library database from January 2010 to February 2018 were reviewed. Random effect model for meta-analysis was used. Analyses such as meta-regression and the “trim-and-fill” method were additionally carried out.RESULTS: A total of seven articles involving 2223 patients were analyzed. Mechanical thrombectomy with BGC was associated with higher rates of successful recanalization (odds ratio [OR], 1.632; 95% confidence interval [CI], 1.293–2.059). BGC did not significantly decrease distal emboli, both before (OR, 0.404; 95% CI, 0.108–1.505) and after correcting for bias (adjusted OR, 1.165; 95% CI, 0.310–4.382). Good outcomes were observed more frequently in the BGC group (OR, 1.886; 95% CI, 1.564–2.273). Symptomatic intracranial hemorrhage and mortality did not differ significantly with BGC use.CONCLUSION: Our meta-analysis demonstrates that BGC enhance recanalization rates. However, BGC use did not decrease distal emboli after mechanical thrombectomies. This should be interpreted with caution due to possible publication bias and heterogeneity. Additional meta-analyses based on individual patient data are needed to clarify the role of BGC in mechanical thrombectomies.


Subject(s)
Humans , Bias , Catheters , Incidence , Intracranial Hemorrhages , Methods , Mortality , Population Characteristics , Publication Bias , Stroke , Thrombectomy
3.
Journal of Korean Neurosurgical Society ; : 389-397, 2019.
Article in English | WPRIM | ID: wpr-765368

ABSTRACT

OBJECTIVE: Mechanical thrombectomies with balloon-guide catheters (BGC) are thought to improve successful recanalization rates and to decrease the incidence of distal emboli compared to thrombectomies without BGC. We aimed to assess the effects of BGC on the outcomes of mechanical thrombectomy in acute ischemic strokes. METHODS: Studies from PubMed, EMBASE, and the Cochrane library database from January 2010 to February 2018 were reviewed. Random effect model for meta-analysis was used. Analyses such as meta-regression and the “trim-and-fill” method were additionally carried out. RESULTS: A total of seven articles involving 2223 patients were analyzed. Mechanical thrombectomy with BGC was associated with higher rates of successful recanalization (odds ratio [OR], 1.632; 95% confidence interval [CI], 1.293–2.059). BGC did not significantly decrease distal emboli, both before (OR, 0.404; 95% CI, 0.108–1.505) and after correcting for bias (adjusted OR, 1.165; 95% CI, 0.310–4.382). Good outcomes were observed more frequently in the BGC group (OR, 1.886; 95% CI, 1.564–2.273). Symptomatic intracranial hemorrhage and mortality did not differ significantly with BGC use. CONCLUSION: Our meta-analysis demonstrates that BGC enhance recanalization rates. However, BGC use did not decrease distal emboli after mechanical thrombectomies. This should be interpreted with caution due to possible publication bias and heterogeneity. Additional meta-analyses based on individual patient data are needed to clarify the role of BGC in mechanical thrombectomies.


Subject(s)
Humans , Bias , Catheters , Incidence , Intracranial Hemorrhages , Methods , Mortality , Population Characteristics , Publication Bias , Stroke , Thrombectomy
SELECTION OF CITATIONS
SEARCH DETAIL