Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Article | IMSEAR | ID: sea-217205

ABSTRACT

Background: The quinolone group, a synthetic antimicrobial, is widely used worldwide to treat many diseases, including those caused by Gram-negative bacteria. Escherichia coli and others are among the bacteria that produce quinolone resistance genes (qnr) such as qnrA and aac(6?)-Ib-cr. Objective: The present study aimed to the isolate Escherichia coli from patients attending some Hospitals in Wad Medani city, identification of drug resistance patterns and detection of the frequency of quinolones resistance genes; qnrA and aac(6?)-Ib-cr among isolated strains. Methods: A cross-sectional descriptive, hospital-based study included 119 Escherichia coli strains was conducted. A designed questionnaire used for demographic data collection and the attitude toward antimicrobials usage. Clinical specimens were processed for aerobic bacterial isolation and identification. Antimicrobial sensitivity performed by Kirby Bauer disc diffusion technique according to the CLSI guidelines. Presence of qnrA and aac(6?)-Ib-cr genes was assessed by multiplex PCR. Results: Most strains of Escherichia coli originated from urine 53.8% (64/119) and wounds 42.9% (51/119) specimens. Meropenem had the best effect against tested strains with susceptibility of 85% (101/119). Multiplex PCR assay, using specific primers, demonstrated that 41.2% (49/119) and 37.8% (45/119) of isolated Escherichia coli possessed qnrA and aac(6?)-Ib-cr genes respectively. Conclusion: The high rate of qnrA and aac (6)-Ib-cr genes among Escherichia coli necessitate the usage of molecular tools in detecting the genetic determinants of drug resistance microorganisms in countries such as Sudan.

2.
Korean Journal of Ophthalmology ; : 304-310, 2021.
Article in English | WPRIM | ID: wpr-902320

ABSTRACT

Purpose@#This study aims to investigate the safety, efficacy and feasibility of sutureless trabeculectomy using a porous collagen matrix that contains a connected porous structure (Ologen) in the control of intraocular pressure (IOP) in glaucoma patients . @*Methods@#The study includes 25 eyes from 24 patients that met the inclusion criteria. All eyes underwent trabeculectomy with the Ologen implant that provides a space with a dynamic and physiological aqueous reservoir system. The operation was considered successful if IOP is <15 mmHg without need of IOP-lowering drops at 18 months of follow-up. @*Results@#The target IOP was achieved in 21 out of the 25 eyes (84%), the remaining four eyes all had an IOP of 16 mmHg at 18 months. Short-term complications consisted of seven cases of bleb leakage treated with bandage contact lens and one case of mild choroidal effusion which resolved after observation alone. @*Conclusions@#We can conclude that this technique can provide safety, effectiveness and short learning curve for ophthalmology trainees with lower incidence of perioperative and postoperative complications. Further studies may be required to prove stability and long-term efficacy in management of glaucoma patients.

3.
Korean Journal of Ophthalmology ; : 304-310, 2021.
Article in English | WPRIM | ID: wpr-894616

ABSTRACT

Purpose@#This study aims to investigate the safety, efficacy and feasibility of sutureless trabeculectomy using a porous collagen matrix that contains a connected porous structure (Ologen) in the control of intraocular pressure (IOP) in glaucoma patients . @*Methods@#The study includes 25 eyes from 24 patients that met the inclusion criteria. All eyes underwent trabeculectomy with the Ologen implant that provides a space with a dynamic and physiological aqueous reservoir system. The operation was considered successful if IOP is <15 mmHg without need of IOP-lowering drops at 18 months of follow-up. @*Results@#The target IOP was achieved in 21 out of the 25 eyes (84%), the remaining four eyes all had an IOP of 16 mmHg at 18 months. Short-term complications consisted of seven cases of bleb leakage treated with bandage contact lens and one case of mild choroidal effusion which resolved after observation alone. @*Conclusions@#We can conclude that this technique can provide safety, effectiveness and short learning curve for ophthalmology trainees with lower incidence of perioperative and postoperative complications. Further studies may be required to prove stability and long-term efficacy in management of glaucoma patients.

SELECTION OF CITATIONS
SEARCH DETAIL