Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Rev. mex. cardiol ; 29(3): 134-143, Jul.-Sep. 2018. tab, graf
Article in English | LILACS | ID: biblio-1020712

ABSTRACT

Abstract: Introduction: EuroSCORE is a probabilistic model with good performance in the prognosis of mortality in heart surgery in many latitudes. It is recommendable to validate it in hospitals where it is employed. Objective: To validate the EuroSCORE model in adult patients at the Hospital Regional de Alta Especialidad del Bajío (HRAEB) of León, Guanajuato, Mexico. Material and methods: We conducted an observational transversal, and retrospective study, accomplishing this through the review of the clinical files of patients submitted to heart surgery with and without extracorporeal circulation pump from 01/01/2008 to 12/31/2013 at the HRAEB. This included mortality up to hospital discharge, utilizing the on-line calculator of the EuroSCORE program to estimate risk of death. In order to validate the EuroSCORE model, we assessed discrimination and calibration through the Area Under the receiver operating characteristics (ROC) curve and χ2 test with Hosmer-Lemeshow (H-L) goodness-of-fit, respectively. Results: A total of 342 patients, aged 50.02 ± 16.66 years, 181 males (52.9%) and 161 women (47.1%). The area under the ROC curve of the additive model was 0.763, and of the Hosmer-Lemeshow test was 5.30, with p = 0.62. The area under the ROC curve of the logistic model was 0.761 and of the Hosmer-Lemeshow test, 8.78, with p = 0.36. Conclusion: The EuroSCORE model is a reliable score for estimating the probabilities of death in adult patients submitted to heart surgery with or without the pump at the HRAEB.


Resumen: Introducción: EuroSCORE es un modelo probabilístico con buen desempeño en el pronóstico de mortalidad en cirugía cardiaca en muchas latitudes. Es recomendable validarlo en los hospitales donde se emplea. Objetivo: Validar el modelo EuroSCORE en pacientes adultos en el Hospital Regional de Alta Especialidad del Bajío (HRAEB) de León, Guanajuato, México. Material y métodos: Se realizó un estudio observacional transversal y retrospectivo, que se completó con la revisión de los expedientes clínicos de pacientes sometidos a cirugía cardiaca con y sin bomba de circulación extracorpórea desde el 01/01/2008 hasta el 31/12/2013 en el HRAEB. Esto incluyó la mortalidad hasta el alta hospitalaria, utilizando la calculadora en línea del programa EuroSCORE para estimar el riesgo de muerte. Para validar el modelo EuroSCORE, evaluamos la discriminación y la calibración a través de la curva de características de operación del receptor (ROC) y la prueba de χ2 con la efectividad de ajuste de Hosmer-Lemeshow (H-L), respectivamente. Resultados: Un total de 342 pacientes, de 50.02 ± 16.66 años, 181 hombres (52.9%) y 161 mujeres (47.1%). El área bajo la curva ROC del modelo aditivo fue de 0.763, y la de la prueba Hosmer-Lemeshow fue de 5.30, con p = 0.62. El área bajo la curva ROC del modelo logístico fue 0.761 y de la prueba Hosmer-Lemeshow, 8.78, con p = 0.36. Conclusión: El modelo EuroSCORE es una herramienta confiable para estimar las probabilidades de muerte en pacientes adultos sometidos a cirugía cardiaca con o sin bomba en el HRAEB.


Subject(s)
Humans , Thoracic Surgery/methods , Risk Adjustment , Cross-Sectional Studies , Retrospective Studies , Risk Assessment
2.
Arch. cardiol. Méx ; 78(4): 392-398, Oct.-Dec. 2008.
Article in English | LILACS | ID: lil-565634

ABSTRACT

OBJECTIVE: To evaluate the diastolic function after regression of left ventricular hypertrophy, in mild to moderate hypertension treated with angiotensin converting enzyme(ACE) inhibitor and, if necessary, with a diuretic. METHODS: Ninety-eight hypertensive patients with left ventricular hypertrophy (LVH) and abnormal left ventricle diastolic function indexes received captopril (Capotena) 50 to 200 mg/day plus chlortalidone during 12 months to reach blood pressure control, defined as a diastolic blood pressure < or =90 and systolic blood pressure < or =140 mm Hg. Left ventricular (LV) mass index was calculated by M mode and two-dimensional echocardiography, and left ventricular diastolic function was assessed by transmitral pulsed Doppler ultrasound every 3 months. RESULTS: Sixty-three patients were women and 35 were men, mean age was 53.4 +/- 8.4 years (range 34-70). Thirty-six patients had mild (36.7%) and 62 (63.3%) moderate hypertension. Treatment reduced significantly both systolic pressure from 165 +/- 13 to 137 +/- 12.9 mm Hg (p<0.05) and diastolic pressure from 99 +/- 8.6 to 86 +/- 6.37 mm Hg (p<0.05). LV mass index decreased from 155.4 +/- 32.9 to 121.7 +/- 29.14 g/m2 (p<0.05). Late diastolic filling velocity (A wave) and the ratio of E/A waves improved (p<0.05), but early diastolic filling velocity (E wave) and isovolumetric relaxation time did not change with treatment. CONCLUSIONS: Some indexes of diastolic function improved after regression of left ventricular hypertrophy and good blood pressure control with captopril and chlortalidone.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Blood Pressure , Hypertension , Hypertrophy, Left Ventricular , Antihypertensive Agents , Blood Pressure/physiology , Captopril , Chlorthalidone , Diastole , Diastole/physiology , Hypertension , Hypertrophy, Left Ventricular , Prospective Studies