Chinese Journal of Surgery ; (12): 203-207, 2022.
Article in Chinese | WPRIM | ID: wpr-935600

ABSTRACT

The modern surgical treatment of cervical degenerative disc disease can be traced back to the advent of anterior cervical decompression and fusion.With the emergence of fusion-related complications,different scholars have promoted the gradual transformation of cervical degenerative disc diseases from "fusion fixation" to "non-fusion reconstruction" through in-depth fusion with materials science,engineering mechanics and other disciplines.The innovation of this treatment concept is consistent with the original intention of "structural remodeling,functional reconstruction,maximum repair and reconstruction of the morphology and function of skeletal muscle system" in orthopedic bionic treatment,which is essentially in line with the "bionic alternative therapy" in orthopedic bionic therapy.This paper focuses on the surgical treatment of cervical degenerative disc diseases,reviews the development history of artificial cervical disc replacement,analyzes the evolution from orthopedic biomimetic therapy,and explores a new direction for the design of artificial cervical disc prostheses and the treatment of cervical degenerative disc diseases in the future.


Subject(s)
Humans , Bionics , Cervical Vertebrae/surgery , Diskectomy , Follow-Up Studies , Intervertebral Disc/surgery , Intervertebral Disc Degeneration/surgery , Spinal Fusion , Total Disc Replacement , Treatment Outcome
2.
Chinese Medical Journal ; (24): 2594-2600, 2019.
Article in English | WPRIM | ID: wpr-771163

ABSTRACT

BACKGROUND@#Reports on the efficacy of modifications to the thread design of pedicle screws are scarce. The aim of the study was to investigate initial and early fixation of pedicle screws with a plasma-sprayed titanium coating and dual pitch in the pedicle region (dual pitch titanium-coated pedicle screw [DPTCPS]) in a polyetheretherketone (PEEK) rod semi-rigid fixation system.@*METHODS@#Fifty-four sheep spine specimens and 64 sheep were used to investigate initial ("0-week" controls) and early (post-operative 6 months) fixation, respectively. Sheep were divided into dual pitch pedicle screw (DPPS), standard pitch pedicle screw (SPPS), DPTCPS, and standard pitch titanium-coated pedicle screw (SPTCPS) groups. Specimens/sheep were instrumented with four screws and two rods. Biomechanical evaluations were performed, and histology at the implant-bone interface was investigated.@*RESULTS@#At 0-week, mean axial pull-out strength was significantly higher for the DPTCPS and SPTCPS than the SPPS (557.0 ± 25.2 vs. 459.1 ± 19.1 N, t = 3.61, P < 0.05; 622.6 ± 25.2 vs. 459.1 ± 19.1 N, t = 3.43, P < 0.05). On toggle-testing, the DPTCPS was significantly more resistant than the SPPS and SPTCPS (343.4 ± 16.5 vs. 237.5 ± 12.9 N, t = 3.52, P < 0.05; 343.4 ± 16.5 vs. 289.9 ± 12.8 N, t = 3.12, P < 0.05; 124.7 ± 13.5 vs. 41.9 ± 4.3 cycles, t = 2.18, P < 0.05; 124.7 ± 13.5 vs.79.5 ± 11.8 cycles, t = 2.76, P < 0.05). On cyclic loading, maximum displacement was significantly lower for the DPTCPS than the SPPS and SPTCPS (1.8 ± 0.13 vs. 3.76 ± 0.19 mm, t = 2.29, P < 0.05; 1.8 ± 0.13 vs. 2.46 ± 10.20 mm, t = 2.69, P < 0.05). At post-operative 6 months, mean axial pull-out strength was significantly higher for the DPTCPS and SPTCPS than the SPPS (908.4 ± 33.6 vs. 646.5 ± 59.4 N, t = 3.34, P < 0.05; 925.9 ± 53.9 vs. 646.5 ± 59.4 N, t = 3.37, P < 0.05). On toggle-testing, the DPTCPS was significantly more resistant than the SPPS and SPTCPS (496.9 ± 17.9 vs. 370.3 ± 16.4 N, t = 2.86, P < 0.05; 496.9 ± 17.9 vs. 414.1 ± 12.8 N, t = 2.74, P < 0.05; 249.1 ± 11.0 vs.149.9 ± 11.1 cycles, t = 2.54, P < 0.05; 249.1 ± 11.0 vs.199.8 ± 7.2 cycles, t = 2.61, P < 0.05). On cyclic loading, maximum displacement was significantly lower for the DPTCPS than the SPPS and SPTCPS (0.96 ± 0.11 vs. 2.39 ± 0.14 mm, t = 2.57, P < 0.05; 0.96 ± 0.11 vs. 1.82 ± 0.12 mm, t = 2.73, P < 0.05). Resistance to toggle testing (370.3 ± 16.4 vs. 414.1 ± 12.8 N, t = 3.29, P < 0.05; 149.9 ± 11.1 vs.199.8 ± 7.2 cycles, t = 2.97, P < 0.05) was significantly lower and maximum displacement in cyclic loading (2.39 ± 0.14 vs.1.82 ± 0.12 mm; t = 3.06, P < 0.05) was significantly higher for the SPTCPS than the DPTCPS. Bone-to-implant contact was significantly increased for the DPTCPS compared to the SPPS (58.3% ± 7.0% vs. 36.5% ± 4.4%, t = 2.74, P < 0.05); there was no inflammatory reaction or degradation of coated particles.@*CONCLUSION@#DPTCPSs might have stronger initial and early fixation in a PEEK rod semi-rigid fixation system.

3.
Chinese Medical Journal ; (24): 2594-2600, 2019.
Article in English | WPRIM | ID: wpr-803153

ABSTRACT

Background@#Reports on the efficacy of modifications to the thread design of pedicle screws are scarce. The aim of the study was to investigate initial and early fixation of pedicle screws with a plasma-sprayed titanium coating and dual pitch in the pedicle region (dual pitch titanium-coated pedicle screw [DPTCPS]) in a polyetheretherketone (PEEK) rod semi-rigid fixation system.@*Methods@#Fifty-four sheep spine specimens and 64 sheep were used to investigate initial ( "0-week" controls) and early (postoperative 6 months) fixation, respectively. Sheep were divided into dual pitch pedicle screw (DPPS), standard pitch pedicle screw (SPPS), DPTCPS, and standard pitch titanium-coated pedicle screw (SPTCPS) groups. Specimens/sheep were instrumented with four screws and two rods. Biomechanical evaluations were performed, and histology at the implant-bone interface was investigated.@*Results@#At 0-week, mean axial pull-out strength was significantly higher for the DPTCPS and SPTCPS than the SPPS (557.0 ± 25.2 vs. 459.1 ± 19.1 N, t = 3.61, P < 0.05; 622.6 ± 25.2 vs. 459.1 ± 19.1 N, t = 3.43, P < 0.05). On toggle-testing, the DPTCPS was significantly more resistant than the SPPS and SPTCPS (343.4 ± 16.5 vs. 237.5 ± 12.9 N, t = 3.52, P < 0.05; 343.4 ± 16.5 vs. 289.9 ± 12.8 N, t = 3.12, P < 0.05; 124.7 ± 13.5 vs. 41.9 ± 4.3 cycles, t = 2.18, P < 0.05; 124.7 ± 13.5 vs.79.5 ± 11.8 cycles, t = 2.76, P < 0.05). On cyclic loading, maximum displacement was significantly lower for the DPTCPS than the SPPS and SPTCPS (1.8 ± 0.13 vs. 3.76 ± 0.19 mm, t = 2.29, P < 0.05; 1.8 ± 0.13 vs. 2.46 ± 10.20 mm, t = 2.69, P < 0.05). At post-operative 6 months, mean axial pull-out strength was significantly higher for the DPTCPS and SPTCPS than the SPPS (908.4 ± 33.6 vs. 646.5 ± 59.4 N, t = 3.34, P < 0.05; 925.9 ± 53.9 vs. 646.5 ± 59.4 N, t = 3.37, P < 0.05). On toggle-testing, the DPTCPS was significantly more resistant than the SPPS and SPTCPS (496.9 ± 17.9 vs. 370.3 ± 16.4 N, t = 2.86, P < 0.05; 496.9 ± 17.9 vs. 414.1 ± 12.8 N, t = 2.74, P < 0.05; 249.1 ± 11.0 vs.149.9 ± 11.1 cycles, t = 2.54, P < 0.05; 249.1 ± 11.0 vs.199.8 ± 7.2 cycles, t = 2.61, P < 0.05). On cyclic loading, maximum displacement was significantly lower for the DPTCPS than the SPPS and SPTCPS (0.96 ± 0.11 vs. 2.39 ± 0.14 mm, t = 2.57, P < 0.05; 0.96 ± 0.11 vs. 1.82 ± 0.12 mm, t = 2.73, P < 0.05). Resistance to toggle testing (370.3 ± 16.4 vs. 414.1 ± 12.8 N, t = 3.29, P < 0.05; 149.9 ± 11.1 vs.199.8 ± 7.2 cycles, t = 2.97, P < 0.05) was significantly lower and maximum displacement in cyclic loading (2.39 ± 0.14 vs.1.82 ± 0.12 mm; t = 3.06, P < 0.05) was significantly higher for the SPTCPS than the DPTCPS. Bone-to-implant contact was significantly increased for the DPTCPS compared to the SPPS (58.3% ± 7.0% vs. 36.5% ± 4.4%, t = 2.74, P < 0.05); there was no inflammatory reaction or degradation of coated particles.@*Conclusion@#DPTCPSs might have stronger initial and early fixation in a PEEK rod semi-rigid fixation system.

4.
Chinese Journal of Surgery ; (12): 1675-1677, 2006.
Article in Chinese | WPRIM | ID: wpr-334432

ABSTRACT

<p><b>OBJECTIVE</b>To investigate the diagnostic value of lumbar discography in discogenic low back pain and the effects of intervertebral fusion surgery.</p><p><b>METHODS</b>Forty-five cases with 101 discs underwent discography, 360 degree fusion manipulation were performed on 18 discography abnormal cases, 27 cases were treated conservatively. Discography, MRI and provocative pain were observed and all the cases were followed up.</p><p><b>RESULTS</b>Twenty-one cases showed positive provocative pain (21/45, 47%), and 21 discs of 101 were concordant discography (21/101, 21%). All cases were followed up for an average 16 months (15 to 23 months), the satisfactory rate was 83% (15/18) in the surgery group and 41% (11/27) in the conservative group.</p><p><b>CONCLUSIONS</b>It is concluded that the discography is moderately sensitive in the diagnosis of discogenic low back pain. Furthermore, the short term follow-up reveals that operative group has better pain relief than conservative group.</p>


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Arthrography , Methods , Diskectomy , Follow-Up Studies , Intervertebral Disc , Diagnostic Imaging , Low Back Pain , Diagnosis , General Surgery , Lumbar Vertebrae , Diagnostic Imaging , Sensitivity and Specificity , Spinal Diseases , Spinal Fusion