Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add filters








Year range
1.
Korean Journal of Ophthalmology ; : 210-217, 2022.
Article in English | WPRIM | ID: wpr-938716

ABSTRACT

Purpose@#To assess the feasibility of applying ultra-widefield fundus (UWF) images for macular staphyloma area (MSA) measurement and investigate the associated factors with MSA. @*Methods@#This is a retrospective study. MSA was measured by UWF imaging. Central foveal thickness, subfoveal choroidal thickness, subfoveal scleral thickness were measured on spectral domain optical coherence tomography. Intraclass correlation coefficients of MSA measurement would be evaluated. Multiple linear regression analysis was used to analyze the associated factors with MSA. @*Results@#In total, 135 eyes of 92 patients were enrolled. The mean age was 64.73 ± 10.84 years. Mean MSA on UWF image was 279.67 ± 71.70 mm2. Intraclass correlation coefficients of MSA measurement was 0.965 (95% confidence interval [CI], 0.946 to 0.977; p < 0.001). In the multiple linear regression analysis, after adjusting for subfoveal choroidal thickness, best-corrected visual acuity, central foveal thickness, and subfoveal scleral thickness, the factors independently related to MSA were axial length (β = 8.352; 95% CI, 3.306 to 13.398; p = 0.001), sex (β = -26.673; 95% CI, -51.759 to -1.586; p = 0.037), age (β = 1.184; 95% CI, 0.020 to 2.348; p = 0.046). @*Conclusions@#It is feasible to measure MSA on UWF image. Female, longer axial length, and older age may indicate larger MSA.

2.
Chinese Journal of Radiation Oncology ; (6): 996-999, 2020.
Article in Chinese | WPRIM | ID: wpr-868726

ABSTRACT

Objective:To identify the key factors affecting the time of proton and carbon ion radiotherapy by analyzing the timing characteristics of the accelerator system and to find out potential solutions to enhance treatment efficiency.Methods:The log files for 47 patients with different types of tumors treated with proton beams and carbon ion beams were analyzed. Lung cancer patients were treated with the gating technology. The timing characteristics of beam delivery were analyzed and potential solutions to enhance treatment efficiency were explored.Results:The mean spill time and mean cycle time per iso-energy slice (IES) for proton radiotherapy with beam gating technology were (2.98±1.98) s and (5.71±4.51) s, which were longer than the radiotherapy without using gating technology. The mean total cycle time for treatment without using gating technology was approximately 7 min for both proton and carbon ion beams. The mean total cycle time for lung cancer treatment using gating technology was approximately 15 min.Conclusion:Application of mini-ridge filter or ripple filter to reduce per IES numbers and use of passive breath hold technology to eliminate interruptions during beam delivery in each IES for gating radiotherapy are two feasible approaches to improve treatment efficiency for this specific machine.

3.
Progress in Modern Biomedicine ; (24): 4864-4868, 2017.
Article in Chinese | WPRIM | ID: wpr-615153

ABSTRACT

Objective:To study the effect of different doses of oxycodone on the serum thromboxane A2 (TXA2),plasma endothelin (ET) levels and immune function of patients underwent laparoscopic cholecystectomy.Methods:90 patients of elective laparoscopic cholecystectomy who were treated from August 2013 to August 2016 in our hospital were selected and divided into 3 groups by random number table,with 30 cases in each group.At the beginning of operation,they were given intravenous oxycodone,group A was given 0.1 mg/kg oxycodone,group B was given 0.2 mg/kg oxycodone,group C was given 0.3 mg/kg oxycodone.The changes of hemodynamics,serum TXA2 and ET levels were compared between the three groups at T0 (after admission),T1 (after anesthesia induction),T2 (after intubation),T3 (gallbladder separation),T4 (end of surgery) and the changes of immune function was compared at T0,T5 (postoperative 2h),T6(postoperative 1d),T7 (postoperative 3d);and the extubation time,recovery time,hypotensor,additional analgesics situationin and adverse reactions were recorded.Results:The diastolic pressure (DBP),systolic blood pressure (SBP),heart rate (HR) in three groups at T2,T3 point was significantly higher than T0 point(P<0.05),the DBP,SBP and HR in the B,C groups were significantly lower than the A group at T2 and T3 point(P<0.05);the TXA2 in three groups at T2,T3,T4 point was significantly higher than T0 point(P<0.05),and A group>B group>C group,there was significant difference between the two groups (P<0.05);the ET in three groups at T2,T3 point was significantly higher than T0 point(P<0.05),the ET in the B,C group was significantly higher than the A group at T2,T3 point(P< 0.05);the CD3+,CD4+,CD8+ and CD4+/CD8+ of the three groups at T5 point were significantly lower than that ofT0 point (P<0.05),the CD3+,CD4+,CD8+ and CD4+/CD8+ in A group were significantly lower than that of B,C group at T5 point (P<0.05);the extubation time in C group was significantly longer than that of A,B group(P<0.05);the total incidence of adverse reactions in C group was significantly higher than that the A,B group (P<0.05).Conclusion:In the laparoscopic cholecystectomy,application of 0.2 mg/kg oxycodone had little effect on hemodynamics,serum TXA2,ET levels and immune function with higher safety.

4.
Chinese Journal of Tissue Engineering Research ; (53): 3837-3842, 2016.
Article in Chinese | WPRIM | ID: wpr-492668

ABSTRACT

BACKGROUND:Preliminary experiments have performed three-dimensional (3D) reconstruction of proximal tibial fractures, digital steel plate design, the establishmentof the proximal tibia plate standard parts library and the operation simulation of 3D printing. OBJECTIVE:To explore feasibility and accuracy of standard parts library plates and screws in the proximal tibial fracture internal fixation navigation in digital design combined with 3D printing model on the basis of preliminary studies. METHODS:Dicom format images of continuous thin layer CT scanning were colected in 20 cases of proximal tibial fractures, and uploaded in Mimics software for 3D reconstruction and fracture reduction. Plate and screw selected from standard part library wereusedfor virtual fixation. Navigation module with screw channel was designed. 3D printing skeleton, bone plate, and navigation module were used for skeleton model and internal fixation. Screw and plate were placed by navigation. Navigation module card, nail and board position were observed. Postoperative appearance and CT scanning were utilized to assess outcomes. RESULTS AND CONCLUSION:After CT scanning and reconstructionin 20 skeleton models, in combination with appearance, the position of plate, screw insertion point, the direction, length and diameter of the screw were consistent with that in Mimics software. The navigation module and the corresponding proximal end of the tibia were closely bonded with good fitting degree. In the application, card slots and stability were good, and could perfectly guide plate and screw placement. These reuslts suggest that with the aid of navigation module, standard parts library plate internal fixation for proximal tibia fracture has high accuracy. On the basis of digital design and 3D printing, digital internal fixation technology of standard parts library plate is expected to achieve good implant navigation in the department of orthopedics.

5.
Chinese Journal of Tissue Engineering Research ; (53): 1895-1903, 2016.
Article in Chinese | WPRIM | ID: wpr-485704

ABSTRACT

BACKGROUND:On CT reconstruction of three-dimensional (3D) model, fracture virtual reduction and internal fixation cannot be achieved, and reasonable operation scheme cannot be formulated. Digital design can fuly meet the needs of clinical orthopedics physicians. Standard parts database can provide the possibility to choose the ideal internal fixation. 3D printing makes the reasonable operation scheme accurate in clinical implementation. OBJECTIVE:To discuss the feasibility, accuracy and minimal invasion of internal fixation in treatment of the distal femoral fracture with digital design of standard parts database by 3D printing. METHODS: (1) Nine adult lower extremity specimens were selected to take continuously thin-layer CT scanning. After Dicom images were imported into the mimics software, the model was established. According to the AO classification, they were classified into A1-3, B1-3 and C1-3 types of distal femoral fracture by virtual design. Internal fixation with plate and screw formed standard parts database virtualy. It was printed out the pilot hole of the navigation module design by three-dimensional printing forming technique. Plate and screw were inserted assisted by the module. X-ray and CT scan were taken postoperatively to access the position. (2) 30 patients with distal femoral fracture were subjected to above fixation. The operation time, intraoperative blood loss and postoperative drainage were recorded. Imaging and curative effects were evaluated during folow-up. RESULTS AND CONCLUSION: (1) Nine samples underwent X-ray and CT scan. 3D reconstruction results revealed plate position, screw entry point, nail direction, length and diameter were consistent with presetting data in Mimics software. The navigation models were designed to fit the lateral bony structure of distal femur. There were good fitting degree, good card position and good stability when the navigation was applied. It could guide plant and screw implantation. (2) In 30 cases, the operation time was (104.63±26.12) minutes, intraoperative blood loss was (121.74±11.49) mL, and postoperative drainage volume was (30.29±6.38) mL. Al patients were folowed up. According to Schagzker criterion, the efficiency of 22 cases was excelent, 6 cases good and 2 cases average, and the excelent and good rate was 93%. The parameters of length, diameter, orientation and angle were consistent with that preoperatively. (3) Internal fixation formed by standard parts database assisted by 3D printing navigation model has advantages of high accuracy, short process, lessened blood loss, high safety, less complications, and precise fixation. Digital design of standard parts database via3D printing navigation module is expected to achieve implant navigation and application.

6.
Chinese Journal of Tissue Engineering Research ; (53): 4235-4241, 2015.
Article in Chinese | WPRIM | ID: wpr-471644

ABSTRACT

BACKGROUND:In three-dimensional CT reconstruction model, fracture virtual reduction and internal fixation cannot be achieved, and reasonable operation scheme cannot be formulated. It cannot fuly meet the needs of clinical orthopedics physicians. OBJECTIVE:To explore the methods to perform three-dimensional reconstruction, reduction on proximal tibial fracture and to design digital plate using software. METHODS:Nine specimens of knee joint were built to be A1-3, B1-3 and C1-3 types of proximal tibial fracture according to the AO standard. Al specimens were treated with CT scan. Three-dimensional reconstruction and reduction on nine types of bone fracture models were performed in Mimics. The digital plates and screws were designed in Solidworks. Virtual internal fixation on the reduced three-dimensional models was performed. RESULTS AND CONCLUSION:Al bone fracture models received three-dimensional reconstruction and reduction, and the design for internal fixational plates and screws as wel as virtual internal fixation were accomplished. A3, B3 and C3 types were presented. These results suggest that the digital plates for proximal tibial fracture could be designed in Mimics and Solidworks with a personal computer. Our experience could be used in the real operation.

7.
Chinese Journal of Tissue Engineering Research ; (53): 1700-1705, 2014.
Article in Chinese | WPRIM | ID: wpr-446420

ABSTRACT

BACKGROUND:Previous studies have found that cholecystokinin octapeptide (CCK-8) can promote the regeneration after sciatic nerve injury in rats, but the exact mechanism remains unclear. OBJECTIVE:To screen effective indicators and analyze the mechanism of CCK-8 promoting sciatic nerve regeneration from the perspective of nerve growth factor and nerve regeneration microenvironment. METHODS:Healthy Sprague-Dawley rats, for the preparation of unilateral sciatic nerve transection injury model, were randomly divided into two groups. In the CCK-8 group, the animal model received intraperitoneal injection of CCK-8 (8 nmol/kg) for consecutive 7 days, while the control group was injected with equal volume of normal saline. The nerve growth factor expression, inducible nitric oxide synthase in the spinal cord, serum superoxide dismutase activity and malondialdehyde concentration, as wel as apoptotic cel s in spinal cord were al detected. RESULTS AND CONCLUSION:In the CCK-8 group, nerve growth factor expression was higher than that in the control group (P<0.01), while inducible nitric oxide synthase and the number of apoptotic cel s were lower (P<0.01), serum superoxide dismutase activity was higher but malondialdehyde concentrations was lower (P<0.01, 0.05). The mechanisms of CCK-8 promoting sciatic nerve regeneration include protecting neurons, anti-apoptosis, inhibiting inflammatory response, anti-NO and anti-oxidation, reducing malondialdehyde, and al eviating free radical damage, as wel as stimulating nerve growth factor expression and release.

8.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 16-17, 2011.
Article in Chinese | WPRIM | ID: wpr-384686

ABSTRACT

Objective To investigate the effect of total hip arthroplasty in treatment of patients with ankylosing spondylitis and bilateral hip bony ankylosis. Methods 43 patients with ankylosing spondylitis and bilateral hip bony ankylosis were randomly divided into observation group (23 cases) and control group (20 cases) in accordance with the principle of informed consent, individually treated by total hip arthroplasty and conservative treatment, the effect of two groups were compared and analyzed. Results In the observation group, the postoperative Harris hip score and the VAS pain score of patients were significantly better than the control group,the differences were all statistically significant between two groups( all P < 0.05 ). Excellent rate of the two groups were 91.3% and 60.0% respectively, and the difference was statistically significant ( x2 = 4.328, P < 0.05 ). Conclusion Total hip arthroplasty in treatment of patients with ankylosing spondylitis and bilateral hip bony ankylosis has better clinical effect, and could improve the quality of life of patients, so it was worthy of clinical application.

SELECTION OF CITATIONS
SEARCH DETAIL