Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Chinese Medical Journal ; (24): 300-305, 2013.
Article in English | WPRIM | ID: wpr-331276

ABSTRACT

<p><b>BACKGROUND</b>Posterior pedicle screw device is widely used in treatment of thoracolumbar burst fractures. As the clinical operation is not based upon quantitative data of adjustments, the results are not optimal. At present, no study has assessed the associations between the device adjustments and the restoration of stiffness. We investigated the biomechanical effects that adjustments of a pedicle screw device had on the burst fracture, and explored an optimal adjustment.</p><p><b>METHODS</b>Burst fractures were produced at L1 vertebra in 24 fresh calf spines (T12-L3). The specimens were divided into four groups at random. Pedicle screw devices were attached to T13 and L2. Four device adjustments, consisting of distraction and extension, were applied. Adjustment 1 was pure 6° extension, adjustment 2 was pure 5 mm distraction, adjustment 3 was 6° extension followed by 5 mm distraction, and adjustment 4 was 5 mm distraction followed by 6° extension. The effect of each adjustment on the stiffness restoration, anatomical reduction, and neural decompression for the burst fractures was analyzed and evaluated.</p><p><b>RESULTS</b>Pure extension (Group 1) produced the closest segment height and the least restoration of the canal to the intact. Pure distraction (Group 2) restored stiffness most, but with only 60% stiffness of the intact value, and lost the segmental angle most to the intact. The combination of extension-distraction (Group 3 and Group 4) produced the maximum reduction of the anatomy and restoration of the canal in the burst fracture, and the least stiffness restoration. The sequence of extension and distraction did not affect stiffness restoration, anatomical reduction, and neural decompression.</p><p><b>CONCLUSIONS</b>The device adjustments affected stiffness restoration, anatomical reduction, and neural decompression. The combined extension-distraction adjustment may be the most suitable considering the anatomical reduction and neural decompression, but the stiffness decreased the most; it should be considered to reconstruct L1 vertebra.</p>


Subject(s)
Animals , Cattle , Female , Male , Biomechanical Phenomena , Fracture Fixation, Internal , Lumbar Vertebrae , Wounds and Injuries , General Surgery , Spinal Fractures , General Surgery , Thoracic Vertebrae , Wounds and Injuries , General Surgery
SELECTION OF CITATIONS
SEARCH DETAIL