ABSTRACT
Objective: To observe the gadolinium imaging findings of inner ear in patients with sudden deafness and to analyze its clinical features. Methods: From November 2017 to July 2020, 21 patients with sudden deafness in the People's Hospital of Dongsheng District, Ordos City were selected as the research objects, including 14 males and 7 females, aged 36-76 years, with a median age of 50 years. The course of disease was 1-19 days, with an average of 5.5 days. The patients received audiology tests, laboratory examination, and intravenous gadolinium angiography, each of whom was scanned twice by 3D-FLAIR sequence: once before intravenous gadolinium injection, and once again 4.5-6.0 h after intravenous gadolinium injection. The following corresponding clinical treatment was given. The imaging manifestations and clinical features were observed. Results: Among 21 cases of sudden deafness in acute stage, the signal intensity of 11 cases was significantly higher than that of the contralateral ear, and 2 cases had vestibular labyrinthine hydrops. In laboratory examination, only 2 cases of total deafness had increased WBC count and faster erythrocyte sedimentation rate, and the rest had no abnormality. The hearing types of 21 patients with sudden deafness were: total deafness in 8 cases, flat decline in 10 cases, low frequency decline in 1 case, high frequency decline in 2 cases. The total effective rate was 57% (12/21). The hearing types of 11 patients with abnormal gadolinium angiography were total deafness in 5 cases, flat decline in 5 cases and high frequency decline in 1 case. The total effective rate was 64% (7/11). Conclusion: Gadolinium angiography is abnormal in some patients with sudden deafness, and the permeability of blood labyrinth barrier may be increased, which is worthy of further study.
Subject(s)
Female , Humans , Male , Middle Aged , Angiography , Deafness , Gadolinium , Hearing Loss, Sudden/diagnostic imaging , Magnetic Resonance Imaging , Vestibule, LabyrinthABSTRACT
The characteristic fingerprint of conventional dairy Nanhanshuishi was established by X-ray diffraction (XRD), based on similarity of caculation on public peaks by MATLAB software, and the feasibility of new dairy technology of microwave method was explored between XRD and the dissolution rate in artificial simulation gastric juices. The result showed that similarity of shared peak in XRD of conventional dairy Nanhanshuishi was > 95%, This XRD characteristic fingerprint of conventional dairy Nanhanshuishi had strong specificity, could be used to provide a reference for identification and quality evaluation. This study also showed that the similarity of microware dairy products and conventional dairy products was good, and the sample of microwave 15 min was the best, and new dairy method by the microwave could replace the traditional method.