ABSTRACT
Objective:To explore the efficacy of the proximal tibial lateral locking plate with rafting screws combined with Jail screws in the treatment of collapse fracture of the lateral tibial plateau.Methods:A retrospective case series study was performed on clinical data of 36 patients with collapse fracture of the lateral tibial plateau admitted to Suqian Hospital of Nanjing Drum Tower Hospital Group from January 2016 to January 2020, including 19 males and 17 females, aged 34-68 years [(48.6±5.8)years]. Schatzker classification was type II in 28 patients and type III in 8 patients. All patients were treated using the proximal tibial lateral locking plate with raft screws combined with Jail screws. The operation time, intraoperative blood loss and fracture healing were detected. The distance of articular surface collapse of the tibial plateau, posterior inclination angle (PSA) of the tibial plateau, tibial plateau varus angle (TPVA) and Rasmussen anatomical score were compared before operation and at day 2 and 1 year after operation. The Hospital for Special Surgery (HSS) score was used to evaluate knee function at day 2 and 1 year after operation. Complications were also recorded.Results:All patients were followed up for 12-32 months [(19.5±3.1)months]. The operation time was 56-82 minutes [(68.5±9.1)minutes]. The intraoperative blood loss was 40-100 ml [(75.6±10.2)ml]. The fracture was clinically healed by first-stage, with the healing time of 8 to 15 weeks [(12.5±1.3)weeks]. The distance of articular surface collapse of the tibial plateau was improved from (15.5±4.2)mm before operation to (0.7±0.3)mm at day 2 after operation and (1.0±0.2)mm at 1 year after operation (all P<0.01). The PSA was improved from (21.2±2.1)° before operation to (8.9±0.8)° at day 2 after operation and (9.2±0.6)° at 1 year after operation (all P<0.01). The TPA was improved from (100.2±3.7)° before operation to (88.9±1.8)° at day 2 after operation and (87.2±1.6)° at 1 year after operation (all P<0.05). The Rasmussen anatomical score changed from (7.8±1.8)points before operation to (17.1±0.9)points at day 2 after operation and (16.3±0.7)points at 1 year after operation (all P<0.01). There were no significant difference in the distance of articular surface collapse of the tibial plateau, PSA, TPVA and Rasmussen anatomical score at day 2 and 1 year after operation (all P>0.05). The HSS score was (92.8±3.2)points at 1 year after operation, significantly higher than (74.8±3.5) points at day 2 after operation ( P<0.01). Two patients sustained superficial wound infection after operation, which healed after debridement and dressing change. No deep infection occurred. Conclusion:For patients with collapse fracture of the lateral tibial plateau, the proximal tibial lateral locking plate with rafting screws combined with Jail screws can effectively prevent secondary collapse of the articular surface and obtain satisfactory anatomical reduction, good functional recovery and few postoperative complications.
ABSTRACT
Objective:To compare the clinical effects of minimally invasive reduction through a bone tunnel combined with Jail screwing and those of posterolateral locking plating in the treatment of simple posterolateral tibial plateau fractures.Methods:A retrospective analysis was conducted of the data of 48 patients who had been operatively treated and completely followed up at Department of Orthopedics, Suqian Hospital of Nanjing Drum Tower Hospital Group for simple posterolateral tibial plateau fractures from October 2016 to October 2020. There were 26 males and 22 females, aged from 35 to 68 years. They were divided into a minimally invasive group (25 cases subjected to minimally invasive reduction through a bone tunnel combined with Jail screwing) and an incision group (23 cases subjected to posterolateral locking plating) according to their surgical methods. The operation time, incision length, intraoperative blood loss, fracture healing time, cumulative fluoroscopy time, hospital stay and posterior inclination angles of the tibial plateau and Hospital for Special Surgery (HSS) knee function scores at 1, 3, 6, 9, and 12 months after operation were compared between the 2 groups. Complications in the 2 groups of patients were recorded.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). The 48 patients were followed up for 12 to 36 months (average 16.5 months). The minimally invasive group was significantly better than the incision group in operation time [(42.6±9.1) min versus (65.7±11.5) min], incision length [(4.0±0.4) cm versus (15.0±1.5) cm], intraoperative blood loss[(22.6±5.8) mL versus (31.5±8.8) mL], hospital stay [(7.6±1.4) d versus (11.1±2.4) d], and HSS score one month after operation [(84.8±1.9) points versus (72.9±4.1) points], but the cumulative fluoroscopy time in the incision group [(4.1±1.4) s]was significantly less than that in the minimally invasive group [(22.3±4.2) s] ( P<0.05). There were no significant differences in fracture healing time, HSS scores at 3, 6, 9, or 12 months after operation, or posterior inclination angle of the tibial plateau between the 2 groups ( P>0.05). There were no such complications as wound infection, vascular injury, internal fixation failure, nonunion or malunion of fractures in either of the 2 groups. Two cases in the incision group presented with symptoms of common peroneal nerve injury but recovered 3 months after operation. Conclusions:Although both minimally invasive reduction through a bone tunnel combined with Jail screwing and posterolateral locking plating can achieve satisfactory outcomes in the treatment of simple posterolateral tibial plateau fractures, the minimally invasive technique is preferable because it shows the advantages of a smaller incision, less bleeding, shorter operation time, a lower operation risk, quicker postoperative recovery and shorter hospital stay.
ABSTRACT
Objective:To evaluate the clinical application of virtual and simulation techniques to aid pre-operative design for precise screw placement into the sustentaculum tali in the treatment of intra-articular calcaneal fractures.Methods:From January 2016 to January 2019, 68 patients were treated at Department of Orthopaedics, Suqian Hospital Affiliated to Xuzhou Medical University for intra-articular calcaneal fractures of Sanders types Ⅱ-Ⅳ. According to different designs of screw placement into the sustentaculum tali, they were assigned into a control group (38 cases and 42 feet) and an observation group (30 cases and 33 feet). There were 24 males and 14 females with an age of 39.3 years±8.8 years in the control group. There were 17 males and 13 females with an age of 42.0 years ± 7.6 years in the observation group. The control group was given a routine placement design based on the X-ray and MSCT scanning images of the injured feet. In the observation group, a Mimics model was first constructed using the X-ray and MSCT scanning images of the normal or less injured feet for further virtual screw placement into the sustentaculum tali on a 3D printed model. The disparity was investigated between the parameters designed and the actual values in both groups. The 2 groups were compared in terms of average placements, screw distribution, placement accuracy, placement time and Maryland scores of foot function one year after operation.Results:There were no significant differences in the preoperative general data between the 2 groups, showing comparability ( P>0.05). The design parameters and actual values in the control group were respectively as follows: 17.7°±3.2° versus 15.1°±5.9° in upward oblique angle, 20.3°±2.1° versus 16.2°±6.8° in backward oblique angle, and 47.9 mm ± 3.8 mm versus 45.4 mm ± 4.2 mm in length of screw path, showing significant differences ( P< 0.05). The design parameters and actual values in the observation group were as follows: 16.5°±3.5° versus 17.1°±3.9° in upward oblique angle, 20.9°±4.3° and 19.6°±3.8° in backward oblique angle, and 48.1 mm ± 3.1 mm versus 47.3 mm ± 3.8 mm in length of screw path, showing insignificant differences ( P>0.05). The average screw placements into the sustenta culum tali in the observation group (1.6±0.5) were significantly more than those in the control group (1.2±0.4). Compared with the control group, the observation group had a higher rate of placement of 2 screws[60.6 % (20/23) versus 16.7% (7/42)], higher accuracy of placement [94.3% (50/53) versus 77.6% (38/49)], less placement time for each screw (9.6 mm±3.9 min versus 13.2 mm±4.7 mm), less placement time for each foot (15.6 mm±4.8 min versus 20.5 mm±3.8 mm), and higher Maryland scores at one year after operation (94.2±6.5 versus 89.7±6.9). All the above comparisons were statistically significant ( P<0.05). Conclusions:Application of virtual and simulation techniques to aid pre-operative design for precise screw placement into the sustentaculum tali can improve the outcomes of intra-articular calcaneal fractures, because it increases the number of screws placed, enhances quality of screw placement, shortens operation time, and thus facilitates functional recovery of the injured foot.
ABSTRACT
Objective To measure the femoral head-neck ratio among Chinese adults in Nanjing to explore its clinical significance. Methods 468 Chinese without hip symptoms were chosen randomly. There were 313 males and 155 females. 13 cases were less than 20 years old, 88 cases were from 21 to 30 years old, 123 cases were from 31 to 40 years old, 104 cases were from 41 to 50 years old, 102 cases were from 51 to 60 years old, 24 cases were from 61 to 70 years old, 14 cases were more than 71 years old. The mean age was 42.4 years old (ranged from 17 to 82 years old). The maximum diameter of the femoral head and the minimum vertical diameter of femoral neck length on both sides were measured by Digimizer software in the standard anteroposterior pelvis film. The femoral head-neck ratio (FHNR) was calculated and compared with that of the western. Results The normal FHNR of Chinese in Nanjing was 1.48 ± 0.09 (1.33-1.69). FHNR was 1.46±0.09 in Chinese aged less than 20 years old. It was 1.48±0.09 in Chinese aged from 21 to 30 years, and 1.47±0.10 in those aged 31-40 years, 1.46±0.09 in 41-50 years, 1.49±0.10 in 51-60 years,1.48±0.08 in 61-70 years, 1.49±0.10 in those more than 71 years. There was no difference between male and female, the left and right side or the different age groups. There was no difference between the western and Chinese in Nanjing. Conclusion FHNR measurement has not variation with regard to sex, age and side. It may be useful to understand some kind of the hip diseases.