Results 1 - 20 de 444
Filter
1.
Medwave ; 24(4): e2775, 30-05-2024.
Article in English | LILACS-Express | LILACS | ID: biblio-1555376

ABSTRACT

Objective To compare the concentration of Low-Density Lipoprotein (LDL-c) obtained using the Friedewald formula with those obtained directly with the RAYTO CHEMRAY 120 autoanalyzer. Methods Cross-sectional study. We evaluated outpatients with a medical request for a lipid profile study (total cholesterol, triglycerides, LDL, and HDL). The analyses were carried out in a RAYTO CHEMRAY 120 autoanalyzer under the principle of spectrophotometry. We obtained LDL-c using the Friedewald and Vujovic formulas. Results We evaluated 199 individuals whose direct LDL concentration averages were measured by the RAYTO CHEMRAY 120 equipment. Those calculated by the Friedewald and Vujovic formulas were 129.97 ± 32.66, 119.28 ± 30.44, and 127.01 ± 32.01, respectively, and in all cases, significant differences (P < 0.001) were observed with the RAYTO analyzer. In both cases a low positive bias was found with the RAYTO analyzer.. The Passing-Bablok and Deming's regressions showed a linear correlation between both methods (Friedewald and Vujovic) with the LDL values obtained with the Rayto autoanalyzer. Conclusions Our study found that the Friedewald and Vujovic methods are good predictors of LDL cholesterol levels and have a low level of bias. Therefore, they could be used as potential predictors.


Objetivo Comparar las concentraciones de Lipoproteínas de Baja Densidad (LDL-c) obtenidas mediante la fórmula de Friedewald con las obtenidas directamente con el autoanalizador RAYTO CHEMRAY 120. Métodos Estudio transversal. Se evaluaron pacientes ambulatorios con solicitud médica de perfil lipídico (colesterol total, triglicéridos, LDL y HDL). Los análisis se realizaron con un autoanalizador RAYTO CHEMRAY 120 bajo el principio de espectrofotometría. Obtuvimos el LDL-c usando las fórmulas de Friedewald y Vujovic. Resultados Se evaluaron 199 individuos cuyos promedios directos de concentración de LDL fueron medidos con el equipo RAYTO CHEMRAY 120. Las concentraciones calculadas por las fórmulas de Friedewald y Vujovic fueron de 129,97 ± 32,66, 119,28 ± 30,44, y de 127,01 ± 32,01, respectivamente, y en todos los casos se observaron diferencias significativas (P < 0,001) con el analizador RAYTO. En ambos casos se encontró un sesgo positivo bajo en el analizador RAYTO. Las regresiones de Passing-Bablok y Deming mostraron una correlación lineal entre ambos métodos (Friedewald y Vujovic) con los valores de LDL obtenidos con el autoanalizador Rayto. Conclusión Nuestro estudio encontro que los métodos de Friedewald y Vujovic son buenos predictores de los niveles de colesterol LDL y presentan un nivel de sesgo bajo. Por lo que podrían usarse como potenciales predictores.

2.
Article in Chinese | WPRIM | ID: wpr-1019973

ABSTRACT

With the progress of information technology and intelligent technology,the intelligent development of urine testing instruments is facing new opportunities.Using the disease cybernetics theory model to analyze the business process and current urine testing instruments of clinical urine analyzer,a generational theoretical model of urine testing instruments has been constructed,which is conducive to guiding the intelligent development direction of urine testing instruments.The study divides urine testing instruments into one to four generations of products,with the first-generation of products being operated by doctors.The second-generation products are currently available for laboratory technicians to use various urine analyzers.The third-generation products further optimize the testing process and intelligence,without the need for inspectors to operate.The fourth-generation products are unmanned and do not require sampling.It can be seen that with the development of technology,urine analysis has indeed become more convenient,but after all,various instruments have their limitations.Therefore,the establishment of a theoretical model for the generation of urine testing instruments should be applied in clinical urine testing,which can not only improve the efficiency of urine analysis but also improve its quality.

3.
International Eye Science ; (12): 1285-1290, 2024.
Article in Chinese | WPRIM | ID: wpr-1038546

ABSTRACT

AIM: To investigate the diagnostic value of the difference of binocular biological parameters of the anterior segment in early keratoconus.METHODS: Retrospective case-control study. A total of 183 patients(366 eyes)who visited our hospital from March 2022 to November 2023 were included, including 107 cases(214 eyes)in the control group(patients with simple refractive error), 40 cases(80 eyes)in the subclinical keratoconus group, and 36 cases(72 eyes)in the clinical keratoconus group. All of the patients were examined by the Pentacam anterior segment analyzer to determine the inferior-superior 3 mm of the posterior corneal surface(I-S), corneal posterior elevation of the thinnest point(P.E.), maximum posterior elevation of the best fit sphere(MPE from BFS), the maximum posterior elevation of the best fit toric ellipsoid(MPE from BFTE), posterior aspherical asymmetry index(AAI), central corneal thickness(CCT), thinnest corneal thickness(TCT), pachymetric progression index average(PPIavg), Ambrósio relational thickness maximum(ARTmax), Belin/ Ambrósio enhanced ectasia display(BAD-D), and the binocular difference of each test was calculated separately for each patient. The control group was further divided according to corneal diameter: 21 cases(42 eyes)with corneal diameter &#x003C;11.2 mm in group A, 54 cases(108 eyes)with 11.2 mm≤ corneal diameter ≤11.8 mm in group B, and 32 cases(64 eyes)with corneal diameter &#x003E;11.8 mm in group C.RESULTS: There was significant differences in the binocular I-S, P.E., MPE from BFS, MPE from BFTE, AAI, CCT, TCT, PPIavg, ARTmax and BAD-D between the clinical keratoconus group and the control group(P&#x003C;0.05). The difference of binocular I-S, P.E., MPE from BFS, MPE from BFTE, AAI, CCT, TCT, PPIavg, and BAD-D were of high diagnostic value(AUC≥0.900), with the best diagnostic ability for P.E. and BAD-D, and an AUC as high as 0.999 and 0.995, respectively. The difference of binocular P.E. and ARTmax between the subclinical keratoconus group and the control group were statistically significant(P&#x003C;0.05). The difference of binocular I-S, P.E. and BAD-D had high diagnostic value for subclinical keratoconus(AUC≥0.900). In the control group A, B and C, there were no significant difference in binocular I-S, CCT, TCT, MPE from BFS, MPE from BFTE, AAI, PPIavg and ARTmax(all P&#x003E;0.05), and none of them had correlation with corneal diameter(P&#x003E;0.05); however, there were statistical significant differences in binocular P.E. and BAD-D in the control group A, B and C(P=0.007, 0.003), while the P.E. differences had no correlation with corneal diameter(P=0.270), and binocular BAD-D differences were negatively correlated with corneal diameter(r=-0.230, P=0.017).CONCLUSION: Pentacam anterior segment analyzer can accurately measure a variety of corneal biological parameters. Difference of binocular corneal I-S, P.E. and BAD-D are sensitive indexes for the early diagnosis of keratoconus. Among them, difference of binocular I-S and P.E. are less affected by corneal diameter, thus being significant for the early diagnosis of keratoconus with different cornea diameters.

4.
China Pharmacy ; (12): 1708-1714, 2024.
Article in Chinese | WPRIM | ID: wpr-1039348

ABSTRACT

OBJECTIVE To evaluate the palatability and chewability of chewable tablets, and provide reference for the quality evaluation of various types of chewable tablets. METHODS Using self-made Glucosamine hydrochloride chewable tablets as the model drug, the quality test was conducted. The in vitro simulation system for chewable tablets was established by using a texture analyzer and rheometer, and an oral simulation experiment was conducted on chewable tablets. The texture analyzer was used to measure the force required for chewing and simulate the static disintegration process of chewable tablets; the rheometer was adopted to measure the viscoelasticity, thixotropy, and deformability of chewable tablets during the chewing process. RESULTS The disintegration time limit, principal component content, and dissolution of self-made Glucosamine hydrochloride chewable tablets all met the limit requirements. The in vitro simulation results of the texture analyzer showed that self-made chewable tablets were easy to chew in both axial and radial directions, and the force required for chewing was within the range of the chewing force of the teeth; chewable tablets could disintegrate at an appropriate time without being chewed and only taken in the oral cavity. The in vitro simulation results of the rheometer showed that the chewable tablets in the oral cavity exhibited a behavior of elasticity as the main factor and viscosity as the secondary factor through the continuous stirring of the tongue, and the viscosity of the chewable tablets gradually decreased with tongue stirring or tooth chewing; when chewing with teeth, the internal force of the chewing tablets decreased, causing plastic deformation and crushing. After being crushed, the shape couldn’t be restored, making it easy to chew and swallow. CONCLUSIONS The combination of texture analyzer and rheometer can be used to simulate the oral chewing process and evaluate the palatability and chewability of self-made Glucosamine hydrochloride chewable tablets. This model can provide reference for the evaluation of various chewable tablets.

5.
Acta bioquím. clín. latinoam ; 57(4): 2-2, dic. 2023. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1556640

ABSTRACT

Resumen Los objetivos del trabajo fueron evaluar el desempeño del analizador de orinas Laura XL® Erba Mannhein, por comparación con el analizador iRICELL® Beckman Coulter y valorar la determinación de proteínas urinarias semicuantitativas como tamizaje en su estudio, con el establecimiento de un punto de corte para su cuantificación. Se emplearon 225 muestras de orina procesadas en simultáneo. Se evaluó pH, densidad, turbidez, color, hemoglobina, glucosa, cetonas, nitritos, proteínas, número de tiras reactivas positivas; células epiteliales, leucocitos, hematíes y criterio de normalidad del sedimento por microscopía. Se cuantificaron las proteínas urinarias positivas por tiras en un Modular COBAS® 8000 (Hitachi-Roche). Se empleó el coeficiente de concordancia Kappa de Cohen (k) y el índice de correlación de Spearman. Se obtuvo escasa concordancia en turbidez (k=0,334), buena concordancia en color (k=0,681), hemoglobina (k=0,620), glucosa (k=0,677), cetonas (k=0,768), nitritos (k=0,827), tiras reactivas positivas (k=0,620), células epiteliales (k=0,783), leucocitos (k=0,745) y hematíes (k=0,609); muy buena concordancia en proteínas (k=0,842) y criterio de normalidad del sedimento (k=1,000). Correlación estadísticamente significativa en pH (r=0,8064; p<0,0001), densidad (r=1,000; p<0,0001) y proteína urinaria (rs=0,9157; p<0,0001) comparada con COBAS® 8000. Se concluyó un desempeño satisfactorio de Laura XL®; se muestra un rendimiento acorde a las necesidades y normativas de este laboratorio y se avala su utilidad como test de tamizaje para la valoración de proteínas urinarias. Se estableció, además, la cuantificación de orinas que presentaron 1+ o más por tira en Laura XL®. Se consideró realizar mejoras en el software.


Abstract The objectives of this work were to evaluate the performance of the Laura XL® Erba Mannheim urine analyzer, in comparison with the iRICELL® Beckman Coulter analyzer, and to assess the determination of semiquantitative urinary protein as screening in its study, establishing a cut-off point for its quantification. A total of 225 urine samples were simultaneously processed. pH, density, turbidity, colour, hemoglobin, glucose, ketones, nitrites, proteins, and number of positive reactive strips were evaluated; and epithelial cells, leukocytes, red blood cells and criteria for normality of the sediment were evaluated by microscopy. Positive urinary proteins per strip were quantified on a Modular COBAS® 8000 (Hitachi-Roche). Cohen's Kappa concordance coefficient (k) and Spearman's correlation index were used. Little agreement was obtained in turbidity (k=0.334), good agreement in colour (k=0.681), hemoglobin (k=0.620), glucose (k=0.677), ketones (k=0.768), nitrites (k=0.827), positive test strips (k=0.620), epithelial cells (k=0.783), leukocytes (k=0.745) and red blood cells (k=0.609); very good agreement for proteins (k=0.842) and sediment normality criteria (k=1,000). Statistically significant correlation in pH (r=0.8064; p<0.0001), density (r=1.000; p<0.0001), urinary protein (rs=0.9157; p<0.0001) compared with COBAS® 8000. A satisfactory performance of Laura XL® was concluded, showing a performance consistent with the needs and regulations of this institution, and its usefulness is endorsed as a screening test for the assessment of urinary proteins, establishing the quantification of urines that present 1+ or more per strip in Laura XL®. Software improvements are considered.


Resumo Os objetivos do trabalho foram avaliar o desempenho do analisador de urina Laura XL® Erba Mannheim, em comparação com o analisador iRICELL® Beckman Coulter, e avaliar a determinação de proteínas urinárias semiquantitativa como triagem em seu estudo, estabelecendo um ponto de corte para sua quantificação. Foram utilizadas 225 amostras de urina processadas simultaneamente. Foram avaliados pH, densidade, turbidez, cor, hemoglobina, glicose, cetonas, nitritos, proteínas, número de testes reativos positivos; células epiteliais, leucócitos, hemácias e critérios de normalidade do sedimento à microscopia. As proteínas urinárias positivas por teste foram quantificadas em um Modular COBAS® 8000 (Hitachi-Roche). Foram utilizados o coeficiente de concordância Kappa de Cohen (k) e o índice de correlação de Spearman. Escassa concordância foi obtida em turbidez (k=0,334), boa concordância em cor (k=0,681), hemoglobina (k=0,620), glicose (k=0,677), cetonas (k=0,768), nitritos (k=0,827), testes reativos positivos (k=0,620), células epiteliais (k=0,783), leucócitos (k=0,745) e hemácias (k=0,609); concordância muito boa para proteínas (k=0,842) e critérios de normalidade do sedimento (k=1,000). Correlação estatisticamente significativa em pH (r=0,8064 p<0,0001), densidade (r=1,000 p<0,0001), proteína urinária (rs=0,9157 p<0,0001) em comparação com COBAS® 8000. A conclusão é um desempenho satisfatório de Laura XL®, mostrando um rendimento consistente com as necessidades e normas deste laboratorio e sua utilidade é endossada como teste de triagem para avaliação de proteínas urinárias, estabelecendo também a quantificação de urinas que apresentaram 1+ ou mais por teste em Laura XL®. Melhorias no software são consideradas.

6.
Indian J Ophthalmol ; 2023 Apr; 71(4): 1488-1494
Article | IMSEAR | ID: sea-224953

ABSTRACT

Purpose: To evaluate dry eyes in children with vernal kerato?conjunctivitis (VKC) and correlate it with symptoms, clinical findings, and ocular surface analysis (OSA) parameters. Methods: Children with clinically diagnosed VKC underwent complete ophthalmological examination, Schirmer’s testing, modified ocular surface disease index (OSDI) scoring, Bonini grading, fluorescein tear?film break?up time (TBUT), VKC – Collaborative Longitudinal Evaluation of Keratoconus (CLEK) scoring, and OSA. Children with a TBUT of < 10 s were defined to have dry eyes. The above?mentioned parameters were compared between dry eye and non?dry eye VKC children. Results: The mean age of the 87 children included in the study was 9.1 ± 2.9 years. Dry eyes were seen in 60.9% [95% confidence interval (CI); 51% to 71%]. The mean TBUT was 13.4 ± 3.8 and 5.9 ± 1.9 s in non?dry and dry eye groups, respectively (P < 0.001). The mean value of Schirmer’s test was 25.9 ± 9.8 and 20.8 ± 8.6 mm in the non?dry and dry eye groups, respectively (P = 0.01). The two groups did not differ in their OSDI scores, Bonini grading, and CLEK scores. The OSA parameter of non?invasive break?up time (NIBUT) was 8.3 ± 3.2 s in non?dry eye group and 6.4 ± 2.9 s in dry eye group, P = 0.008. The lower lid Meibomian gland (MG) loss was 7.4% in non?dry eye group and 12.2% in dry eye group, P = 0.028. Other OSA parameters did not differ significantly among the two groups. Conclusion: Dry eyes are seen in two?thirds of pediatric VKC. Evaluation of dry eyes should be incorporated in their clinical evaluation. Among OSA parameters, NIBUT and lower lid MG loss are associated with dry eyes in pediatric VKC patients.

7.
Article in Chinese | WPRIM | ID: wpr-995726

ABSTRACT

Objective:To evaluate the performance of an artificial intelligent (AI)-based automated digital cell morphology analyzer (hereinafter referred as AI morphology analyzer) in detecting peripheral white blood cells (WBCs).Methods:A multi-center study. 1. A total of 3010 venous blood samples were collected from 11 tertiary hospitals nationwide, and 14 types of WBCs were analyzed with the AI morphology analyzers. The pre-classification results were compared with the post-classification results reviewed by senior morphological experts in evaluate the accuracy, sensitivity, specificity, and agreement of the AI morphology analyzers on the WBC pre-classification. 2. 400 blood samples (no less than 50% of the samples with abnormal WBCs after pre-classification and manual review) were selected from 3 010 samples, and the morphologists conducted manual microscopic examinations to differentiate different types of WBCs. The correlation between the post-classification and the manual microscopic examination results was analyzed. 3. Blood samples of patients diagnosed with lymphoma, acute lymphoblastic leukemia, acute myeloid leukemia, myelodysplastic syndrome, or myeloproliferative neoplasms were selected from the 3 010 blood samples. The performance of the AI morphology analyzers in these five hematological malignancies was evaluated by comparing the pre-classification and post-classification results. Cohen′s kappa test was used to analyze the consistency of WBC pre-classification and expert audit results, and Passing-Bablock regression analysis was used for comparison test, and accuracy, sensitivity, specificity, and agreement were calculated according to the formula.Results:1. AI morphology analyzers can pre-classify 14 types of WBCs and nucleated red blood cells. Compared with the post-classification results reviewed by senior morphological experts, the pre-classification accuracy of total WBCs reached 97.97%, of which the pre-classification accuracies of normal WBCs and abnormal WBCs were more than 96% and 87%, respectively. 2. The post-classification results reviewed by senior morphological experts correlated well with the manual differential results for all types of WBCs and nucleated red blood cells (neutrophils, lymphocytes, monocytes, eosinophils, basophils, immature granulocytes, blast cells, nucleated erythrocytes and malignant cells r>0.90 respectively, reactive lymphocytes r=0.85). With reference, the positive smear of abnormal cell types defined by The International Consensus Group for Hematology, the AI morphology analyzer has the similar screening ability for abnormal WBC samples as the manual microscopic examination. 3. For the blood samples with malignant hematologic diseases, the AI morphology analyzers showed accuracies higher than 84% on blast cells pre-classification, and the sensitivities were higher than 94%. In acute myeloid leukemia, the sensitivity of abnormal promyelocytes pre-classification exceeded 95%. Conclusion:The AI morphology analyzer showed high pre-classification accuracies and sensitivities on all types of leukocytes in peripheral blood when comparing with the post-classification results reviewed by experts. The post-classification results also showed a good correlation with the manual differential results. The AI morphology analyzer provides an efficient adjunctive white blood cell detection method for screening malignant hematological diseases.

8.
Acta Medica Philippina ; : 72-91, 2023.
Article in English | WPRIM | ID: wpr-998844

ABSTRACT

Objectives@#The implementation of Philippine National Standard PNS ISO 15189:2013 to support the medical laboratory to produce competent results is a recognised challenge. It is apparent that the approach of ensuring the equipment availability can be specifically optimised. No known research has focused on exploring on the conduct of conformity evaluation of Afinion 2 Analyzer maintainability for the PNS ISO 15189:2013 accredited medical laboratory. The aim of the current study was to develop a practical tool for the medical laboratory to support the internal audit process by determining the compliance status of Afinion 2 Analyzer maintainability. @*Methods@#The relevant conformance requirements in Clauses 4 (Management requirements) and 5 (Technical requirements) of PNS ISO 15189:2013, manufacturer requirements and specific requirements for accreditation from 70/101 (69%) accreditation bodies in 80/249 (32%) countries were identified as specific audit criteria for Afinion 2 Analyzer conformity evaluation checklists for the maintenance and reference equipment.

9.
International Eye Science ; (12): 267-272, 2023.
Article in Chinese | WPRIM | ID: wpr-960949

ABSTRACT

AIM: To investigate the diagnostic value of ocular morphological parameters under different corneal diameters for early keratoconus.METHODS: A retrospective case-control study. A total of 201 patients(201 eyes)who were treated in our hospital from January 2019 to March 2022 were included. They were divided into 135 cases(135 eyes)in the control group(patients with history of refractive error)and 66 cases(66 eyes)in the subclinical keratoconus group. The Pentacam anterior segment analyzer was used to determine the horizontal central curvature of corneal posterior surface(Kf), posterior vertical central curvature of corneal posterior surface(Ks), average curvature of corneal posterior surface(Km), Posterior I-S ratio, corneal posterior surface height after the thinnest point(PE at the thinnest point), maximum posterior elevation from best fit sphere(MPE from BFS), maximum posterior elevation from best fit toric ellipsoid(MPE from BFTE), posterior asphericity asymmetry index(AAI), thinnest point thickness of the cornea(TCT), central corneal thickness(CCT), depressed corneal thickness(DCT), pachymetric progression index average(PPIavg), Ambrósio relational thickness maximum(ARTmax)and Belin D value. The differences of each parameter between the two groups were analyzed. Receiver operating characteristic(ROC)curves were analyzed to determine the best diagnosis point. The control group was further divided into groups according to the corneal diameter: corneal diameter ≤11.0mm, 11.1mm≤ corneal diameter ≤11.5mm, 11.6mm≤ corneal diameter ≤12.0mm, corneal diameter ≥12.1mm. The differences of each parameter among these groups were compared. Pearson correlation analysis was used to analyze the correlation between corneal diameter and other parameters.RESULTS: There were significant differences in posterior I-S ratio, PE at the thinnest point, MPE from BFS, MPE from BFTE, posterior AAI, TCT, DCT, PPIavg, ARTmax, Belin D value between the subclinical keratoconus group and the control group(P&#x0026;#x003C;0.05). Sensitive index of Pentacam to diagnosis subclinical keratoconus were Belin D value, posterior I-S ratio, PPIavg, posterior AAI and MPE from BFTE(AUC≥0.9). In the control group, there was no significant difference in posterior I-S ratio, MPE from BFTE, posterior AAI, TCT, CCT, and DCT among different corneal diameter groups (P&#x0026;#x003E;0.05), and there was no significant correlation with corneal diameter(all P&#x0026;#x003E;0.05).CONCLUSION: The Belin D value, posterior I-S ratio, PPIavg, posterior AAI, MPE from BFTE obtained by Pentacam are sensitive indicators for the diagnosis of early keratoconus, among which posterior I-S ratio, posterior AAI, MPE from BFTE are less affected by corneal diameter. They play an important role in the early diagnosis of keratoconus under different corneal diameters.

10.
International Eye Science ; (12): 273-277, 2023.
Article in Chinese | WPRIM | ID: wpr-960950

ABSTRACT

AIM: To explore Bland-Altman analysis of corneal curvature and astigmatism measured by new swept-source optical coherence tomography(SS-OCT)and Scheimpflug anterior segment analyzer in patients with age-related cataract.METHODS: A total of 177 patients(282 eyes)with age-related cataract admitted to the hospital between January and December 2021 were enrolled. The steep-axis curvature(Ks), flat-axis curvature(Kf), mean corneal curvature(Km), corneal astigmatism and astigmatism axis of anterior corneal surface, posterior surface and the whole cornea were measured by SS-OCT and Scheimpflug anterior segment analyzer respectively. All parameters were detected by paired sample t-test, intra-group repeatability test, Pearson correlation and Bland-Altman consistency analysis.RESULTS: There was no significant difference in Ks, Kf and Km of anterior corneal surface measured by SS-OCT and Scheimpflug anterior segment analyzer(P&#x0026;#x003E;0.05). Ks, Kf and Km of posterior corneal surface and whole cornea measured by Scheimpflug anterior segment analyzer were all greater than those measured by SS-OCT(P&#x0026;#x003C;0.05). There was no significant difference in astigmatism and axial values of anterior corneal surface, posterior surface and whole cornea measured by SS-OCT and Scheimpflug anterior segment analyzer(P&#x0026;#x003E;0.05). The intraclass correlation coefficient(ICC)of all parameters was greater than 0.88, indicating a good intra-group repeatability. Ks, Kf, Km, astigmatism and axis of anterior corneal surface, posterior surface and whole cornea measured by SS-OCT were positively correlated with those measured by Scheimpflug anterior segment analyzer(P&#x0026;#x003C;0.05). Bland-Altman consistency analysis showed that Ks, Kf, Km, corneal astigmatism and axis of anterior corneal surface, posterior surface and whole cornea measured by SS-OCT were highly consistent with those measured by Scheimpflug anterior segment analyzer(P&#x0026;#x003C;0.05).CONCLUSION: The corneal curvature and astigmatism parameters measured by new SS-OCT are highly consistent with those measured by Scheimpflug anterior segment analyzer, which can be applied in the diagnosis of corneal curvature and astigmatism in patients with age-related cataract.

11.
Article in Chinese | WPRIM | ID: wpr-1010231

ABSTRACT

Ventilator is an important medical instrument which can replace the function of autonomous ventilation artificially. Its safety and reliability are related to the health and even life safety of patients. With the publishing of the new national standard and international standard for ventilators, higher requirements are put forward for the detection and evaluation. This study mainly introduces an automatic test system for ventilator performance. The test system is based on PF-300 air-flow analyzer of Imtmedical and standard simulation lung. The automatic switch module of simulation lung is developed, and the automatic test system of ventilator is designed using the software development platform based on Python. It can not only automatically test all ventilation control parameters and monitoring parameters of the ventilator, but also realize automatic data recording, form reports and data analysis, and improve the efficiency and quality of inspection, detection and quality control.


Subject(s)
Humans , Reproducibility of Results , Ventilators, Mechanical , Computer Simulation , Data Analysis , Quality Control
12.
Article in Chinese | WPRIM | ID: wpr-1022895

ABSTRACT

Objective To propose a UML-based architecture design method of the automatic verification system for Siemens ADVIA2400 Automatic Biochemical Analyzer to solve the problems of manual verification in time cost,labor cost and sample turnaround time.Methods Automatic verification rules were established with AUTO 10-A guidelines and Sergey Brin logic,and UML design tools and Enterprise Architect software were used to develop the automatic verification system software involving in the use case model,dynamic model,logic model and physical deployment model,then the index thresholds were determined based on the practical experience of the clinical laboratory department and the specifications such as the instrument SOPs of the biochemical group.The automatic verification system was tested and validated with the working experience.Results The automatic verification system developed detected the changes in the patient's indexes and gave alarms accurately,which shortened the sample turnaround time by about 25.6%when compared with manual verification.Conclusion The automatic verification system for Siemens ADVIA2400 Automatic Biochemical Analyzer gains advantages in stability,reliability and efficiency during clinical laboratory examination.[Chinese Medical Equipment Journal,2023,44(10):81-85]

13.
Chinese Journal of Endemiology ; (12): 1004-1007, 2023.
Article in Chinese | WPRIM | ID: wpr-1023969

ABSTRACT

Objective:To study the application of antimony cerium catalytic spectrophotometry using a fully automatic biochemical analyzer (hereinafter referred to as this method) in the determination of water iodine.Methods:Based on the principle of antimony cerium reoxidation reduction reaction catalyzed by iodine, the iodine content in water was determined in the range of 0 - 100 μg/L iodine mass concentration. The detection limit, precision and accuracy (determination of standard substances GBW09113j and GBW09114j for iodine composition analysis in water and the experiment of standard recovery) of this method were verified. This method was compared with the arsenic and cerium catalytic spectrophotometry recommended by the National Reference Laboratory for Iodine Deficiency Disorders.Results:Within the range of 0 - 100 μg/L iodine mass concentration, the qualitative and quantitative detection limits of this method were 0.81 and 2.70 μg/L, respectively (sampling quantity was 35 μl). In the precision experiment, the relative standard deviation of water samples with different iodine mass concentrations ranged from 1.2% to 4.0%. The determination results of the standard substances GBW09113j and GBW09114j for iodine composition analysis in water were both within the given standard value range. The standard recovery rates of water samples with low, medium and high iodine mass concentrations ranged from 101.0% to 106.0%, and the total average standard recovery rate was 103.2%. The results of the method comparison experiment showed that there was no statistically significant difference in the results of water iodine determination between the two methods ( t = - 0.78, P = 0.779). Conclusion:This method has a low detection limit, high precision and good accuracy, making it suitable for the detection of large quantities of samples in the monitoring of iodine deficiency disorders.

14.
Article in Chinese | WPRIM | ID: wpr-1019094

ABSTRACT

Objective To investigate the effects of high concentration of semen samples in detection by fully automated sperm quality analyzer for sperm concentration,progressive motility(PR),non-progressive motility(NP)and percentage of immotile sperm(IM).Methods The semen samples from the patients who visited the reproductive clinic in our hospital from February 2023 to May 2023 were analyzed using the fully automated sperm quality analyzer.A total of 155 semen samples with initial sperm concentration ≥100× 106/mL and semen volume ≥1.5 mL were set as the high concentration semen group(group A).The semen samples with self seminal plasma dilution group(group B)and 37 ℃ normal saline dilution group(group C)were prepared with their own seminal plasma and normal saline at 1∶2 dilution ratio respectively.The sperm concentration of group A was detected by the manual method as the control.The sperm concentration and motility parameters of each group were detected.The differences of sperm concentration and the values of PR,NP and IM among the group A,B and C were analyzed.The correlations between sperm concentration and PR,NP and IM were also assessed.Results The sperm concentration of group A was significantly lower than that of the control group and groups B and C(all P<0.05).There was no statistically significant difference for the results between group B and group C(P>0.05).The PR in group C was significantly lower than that in groups A and B(all P<0.05),and there was no significant difference of PR between group A and group B(P>0.05).The values of NP in group A was significantly higher than that in groups B and C(all P<0.05),and there was no significant difference in NP between group B and group C(P>0.05).The IM in group A was significantly lower than that in groups B and C(all P<0.05),and there was no statistical difference of IM values between group B ang group C(P>0.05).Conclusion The direct analysis of undiluted semen samples with high sperm concentration may lead to lower results of sperm concentration,increased percentage of NP sperm and decreased percentage of IM sperm.The dilution of semen samples may improve the accuracy of the detec-tion results.The dilution with 37 ℃ normal saline can lead to decrease of the percentage of PR sperm.The self seminal plasma should be recommended as the first choice of diluent for the semen samples with high sperm concentration.

15.
Article in Chinese | WPRIM | ID: wpr-1029844

ABSTRACT

Objective:To assess the role of Delta-RBC parameters in the automated hematocrit analyzer RET channel for the recognition of cold agglutinins (CA) and to explore the value of RET channel optical method parameters in correcting interference with CA.Methods:This is a retrospective study. The Cas group included 68 samples with Cas interference and the control group included 45 samples without CA interference. All specimens were collected from Zhongshan Hospital Fudan University Outpatient Department from January 2022 to January 2023. Specimens in both the CA and Control group were examined using the CBC+RET channel at room temperature. Recorded and calculated the Impedance method test parameters RBC-I, HGB, HCT-I, MCH-I, MCV-I, MCHC-I and the Optical method test parameters RBC-O, HCT-O, MCH-O, R-MFV, MCHC-O, Delta-RBC. Examined the specimens in the CA group using the CBC channel after prewarmed at 37 ℃ for 2 h, and Impedance method parameters RBC-I 37 ℃ 2 h, HGB 37 ℃ 2 h, HCT-I 37 ℃ 2 h, MCH-I 37 ℃ 2 h, MCV-I 37 ℃ 2 h, MCHC-I 37 ℃ 2 h were recorded. The ROC curves were used to analyze the discrimination efficacy of Delta-RBC in identifying CA interference, and the Bland-Altman method was used to analyze the consistency between the results of the optical method RBC parameters at room temperature and the results of the impedance method after prewarming. The correlation analysis was performed using Pearson and Spearman correlation analysis to analyze the results of the RBC parameters before and after prewarming in the CA group. Result:If Delta-RBC was used as diagnostic indicators for the identification of CA interference, the best cut-off value was 1.065, with AUCs of 0.998. In the CA group, the correlation coefficients between RBC-O, HCT-O, R-MFV, MCH-O, MCHC-O, and RBC-I 37 ℃ 2 h, HCT-I 37 ℃ 2 h, MCV-I 37 ℃ 2 h, MCH-I 37 ℃ 2 h, MCHC-I 37 ℃ 2 h were 0.985, 0.981, 0.729, 0.870, and 0.649, respectively. The percentages within the limits of agreement of the percentage differences between the results of the two methods were 95.6%, 92.6%, 95.6%, 94.1%, and 95.6%, respectively. Conclusions:The RBC parameter Delta-RBC from RET channel optical method can be used as an indicator to effectively assist in the clinical determination of the presence of CA. Reporting results using the optical method RBC parameters of the RET channel can correct the interference of CA without specimen pre-treatment and obtain more correct results of complete blood counts.

16.
Psicol. ciênc. prof ; 43: e248295, 2023.
Article in Portuguese | LILACS, INDEXPSI | ID: biblio-1431129

ABSTRACT

Este ensaio propõe que a Covid-19 pode operar como um analisador, dentro da perspectiva da análise institucional, iluminando um determinado modo de organização social que promove profundas desigualdades e ameaça a vida em diversos níveis e revelando as condições sociais, institucionais e políticas de produção de sofrimento no corpo profissional de Enfermagem. A pandemia desvelou um conjunto de marcas relacionadas à profissão, agravadas pela crise sanitária, reforçando a naturalização das relações de cuidado atribuídas ao feminino, bem como um conjunto de clivagens e hierarquias internas à profissão a partir da sinergia de marcadores da diferença, como gênero, cor/raça, classe e geração. Além disso, este trabalho mostra a presença de uma necropolítica nas respostas à pandemia que banaliza a vida e permite morrer determinados grupos sociais. A ideia de "profissionais de linha de frente" é criticada em suas metáforas bélicas, mas tomada como figura de linguagem em sua potência para afirmar que existem corpos que, pelas marcas sociais e históricas e pela interdependência do cuidado, são mais presentes e exigidos e, portanto, mais vulneráveis à doença e ao sofrimento dela decorrente.(AU)


The essay proposes that Covid-19 can operate as an analyzer, within the perspective of institutional analysis, illuminating a certain mode of social organization that promotes profound inequalities and threatens life at various levels, revealing the social, institutional and political conditions for the production of suffering in the professional nursing body. The pandemic would unveil a set of marks related to the profession, aggravated by the sanitary crisis, reinforcing the naturalization of the care relations attributed to the feminine, as well as a set of cleavages and internal hierarchies to the profession from the synergy of markers of difference as gender, color/race, class and generation. The work shows the presence of necropolitics in responses to the pandemic, which trivializes life and allows certain social groups to die. The idea of "front-line professionals" is criticized in its war metaphors, but taken as a figure of speech in its potency to affirm that there are bodies that by social and historical marks, and by the interdependence of care, are more present and demanded, and therefore more vulnerable to disease and the resulting suffering.(AU)


El ensayo propone que el Covid-19 puede funcionar como analizador, desde la perspectiva del análisis institucional, revelando las condiciones sociales, institucionales y políticas de producción de sufrimiento de enfermeras. La pandemia revela algunas marcas relacionadas con la profesión, agravadas por la crisis de salud, reforzando la naturalización de la atribución del cuidado a lo femenino y un conjunto de jerarquías internas de la profesión. El trabajo también muestra la presencia de una necropolítica en las respuestas a la pandemia. La idea de "profesionales de primera línea" es criticada, pero tomada como una figura del lenguaje en su potencia para afirmar que hay cuerpos que, por las marcas sociales e históricas y por la interdependencia del cuidado, están más presentes y demandados, y por lo tanto más vulnerables a la enfermedad.(AU)


Subject(s)
Humans , Female , Nursing , Psychological Distress , Gender Identity , Self-Testing , COVID-19 , Oxygen Inhalation Therapy , Pain , Patient Care Team , Patient Discharge , Patients , Politics , Primary Health Care , Psychology , Quality Assurance, Health Care , Quality of Life , Race Relations , Salaries and Fringe Benefits , Social Change , Social Isolation , Social Sciences , Socioeconomic Factors , Stress Disorders, Post-Traumatic , Women, Working , Behavior and Behavior Mechanisms , Population Characteristics , Nursing Theory , Occupational Risks , Burnout, Professional , Virus Diseases , Vaccines , Nursing Research , Accidents, Occupational , Carrier State , Mental Health , Mortality , Models, Nursing , Occupational Health , Workload , Professional Autonomy , Long-Term Care , Health Care Quality, Access, and Evaluation , Immunization Programs , Disease Transmission, Infectious , Continuity of Patient Care , Feminism , Critical Care , Disaster Vulnerability , Health Risk , Access to Information , Delivery of Health Care , Air Pollution , Health Care Economics and Organizations , Emergencies , Employment , Environment and Public Health , Essential Public Health Functions , Health Status Disparities , Ethics, Professional , Surveillance of the Workers Health , Program of Risk Prevention on Working Environment , Air Contamination Effects , Evidence-Based Nursing , Fear , Remuneration , Early Medical Intervention , Medicalization , Ambulatory Care , Personal Protective Equipment , Psychosocial Support Systems , Occupational Stress , Burnout, Psychological , Patient Care , Caregiver Burden , Models, Biopsychosocial , COVID-19 Serological Testing , Gender Equity , Vaccine Development , Community Resources , Intersectional Framework , Systemic Racism , Social Vulnerability , Humanitarian Crisis , Working Conditions , Post-Acute COVID-19 Syndrome , Accident Prevention , Health Occupations , Health Services , Health Services Accessibility , Helping Behavior , Hierarchy, Social , Hospitalization , Hospitals , Humanism , Life Support Care , Masks , Muscle Tonus , Night Care , Nursing Care , Nursing, Practical , Nursing, Team , Occupational Diseases
17.
Article | IMSEAR | ID: sea-221250

ABSTRACT

ZnO and CdO pellets with and without Mn doping were prepared by using Hydraulic pressure machine at room temperature. The effect of Mn content (1,3,5 wt % ) on the electrical properties have been carried out by Keithley meter. The result shows that the resistivity decreases as increasing Mn content. Impedance analyzer are used for dielectric behavior and results shows that decrement of dielectric constant as well as dielectric loss with the increment of frequency

18.
Article | IMSEAR | ID: sea-220007

ABSTRACT

Background: One of the most widely performed surgical procedures nowadays is cataract surgery combined with monofocal intraocular lens implantation (IOL). Monofocal IOLs can compensate for the spherical refractive error but not astigmatism. Thus, patients with astigmatism are unable to see well after surgery without spectacles. A new generation of IOLs called toric IOLs, improve uncorrected visual acuity in eyes with high astigmatism due to a specific lens design. This study aimed to present a practical method of toric intraocular lens (IOL) implantation based on a refractive power analyzer system and slit-lamp observation.Material & Methods:This prospective study comprised 30 patients who underwent toric IOL implantation with cataract extraction at the Department of Ophthalmology, National Institute of Ophthalmology, Dhaka, Bangladesh. This study was conducted from Jan 2021 to Dec 2021. Approval from the local ethical committee was obtained.Results:The study included 45 eyes of 30 patients. The sex distribution of the study patients where the male was 18(60%) and the female was 12(40%). In the age distribution of the study, 5(16.67%) patients were from the 60-69 range, 10(33.33%) patients were from the 70-79 range, and 15(50.00%) patients were from the 80-89 range. The patients’ demographic variables consequently. Changes in visual acuity and refraction are shown in table-4 thorough preoperative and postoperative. Postoperative IOL alignment methods are shown in table-5, the mean±SD of the slit-lamp target was 2.55±2.76 and in the range, of 0.0 to 12.0, the mean±SD of the corneal analyzer target was 2.55±1.98 and range was 0.0 to 11.0, and the mean±SD of the slit-lamp corneal analyzer was 3.27±2.98 and range was 0.0 to 16.0.Conclusions:We studied 2 methods of assessing toric IOL alignment postoperatively and found no significant difference between them. Both were reliable and predictable. In addition, we found that the simple preoperative marking technique we used yielded toric IOL alignment that was as accurate as that obtained with other commonly used techniques and that was within a clinically acceptable level.

19.
Indian J Ophthalmol ; 2022 Jun; 70(6): 1963-1970
Article | IMSEAR | ID: sea-224357

ABSTRACT

Purpose: To compare the efficacy of physiological, non?detergent eyelid wipes with conventional lid hygiene in patients with meibomian gland dysfunction (MGD). Methods: Fifty participants with MGD were recruited and randomized into two groups. Participants in group I used Evolve Pure? Eyewipes twice a day to clean the eyelid debris along with standard therapy (antibiotic and lubricants) and participants in group II followed lid hygiene with warm compresses along with standard therapy. Symptoms, ocular surface assessment (lipid layer thickness, tear meniscus height, non?invasive tear film breakup time, and meibography), slit?lamp biomicroscopy (eyelash contamination, meibomian gland blockage, meibomian gland secretion, and meibomian gland telangiectasia) and tear film osmolarity were noted at baseline and 90 days after therapy. Results: Significant improvement in symptoms and signs of MGD was observed in both groups after treatment (P < 0.001); however, the clinical improvement was better with the use of eyelid wipes. Lipid layer thickness increased significantly in group I (P = 0.0006) and group II (P = 0.0002), which was maintained even after adjusting for sociodemographic variables such as age, sex, and severity score of symptoms and signs. Conclusion: Lipid layer thickness of the tear film is a sensitive marker in monitoring response to treatment in patients with MGD. The use of physiological detergent?free eyelid wipes is non?inferior to lid hygiene and warm compresses, which remains the mainstay for treatment of MGD; the clinical improvement with eyelid wipes was noted to be better

20.
Article | IMSEAR | ID: sea-218304

ABSTRACT

Background: High performance liquid chromatography (HPLC) is the most commonly used method for detection and quantitative estimation of hemoglobin variants. Hemoglobinopathies are amongst the most common genetically inherited disorders, however, the exact magnitude of different hemoglobinopathies is obscure in India. This study was done with the aim of analyzing the different findings in HPLC using D-10 analyzer and evaluating the spectrum of different hemoglobin disorders in a hospital-based population of South Delhi. Such a prevalence study would be useful to review the various strategies that can be implemented for effective control and prevention of these disorders. Methods: A hospital based descriptive observational study was conducted in which all OPD and IPD patients who were advised HPLC during their clinical workup were included. Analysis of EDTA blood samples was done by Bio Rad D10 Dual program HPLC instrument. The exact percentage of HbA, HbA2, HbF and any other variant hemoglobin was estimated. Presumptive identification of hemoglobin variants was made primarily by their percentage, retention time (RT) and peak characteristics. HPLC findings were correlated with the clinical history, family history and the CBC and peripheral smear findings in all cases. Results: On HPLC analysis, 79% of the patients had no abnormality detected and the report was within normal limits. The commonest hemoglobinopathy was Beta Thalassemia Trait followed by HbE trait. The other hemoglobinopathies detected were HbD Punjab Heterozygous (3 cases, 0.5%), Beta thalassemia homozygous (3 cases, 0.5%), Sickle cell Heterozygous (2 cases, 0.3%), HbJ Meerut Heterozygous (2 cases, 0.3%). One case each of Sickle cell Homozygous (0.15%), Compound Heterozygous HbS/beta thalassemia trait (0.15%), HbE Homozygous (0.15%), Compound Heterozygous HbE/beta thalassemia trait (0.15%), and Homozygous delta beta thalassemia (0.15%) were also diagnosed. Conclusion: This study gives an important insight to the present day scenario of hemoglobinopathies in patients in South Delhi in relation to the hematological profile. It highlights the chromatogram findings of different hemoglobinopathies on the D10 analyzer. The comprehensive data obtained by such series can help in the formulation and development of infrastructure and policies for hemoglobinopathy prevention, diagnosis and management.