Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Shanghai Journal of Preventive Medicine ; (12): 1229-1233, 2022.
Article in Chinese | WPRIM | ID: wpr-964220

ABSTRACT

ObjectiveTo determine the level of serum 25-hydroxyvitamin D (25(OH)D) and its association with thyroid autoantibodies and thyroid nodules in adult women for health examination in Shanghai. MethodsWe recruited a total of 2 108 healthy women for examination in the hospital. According to the serum 25-hydroxyvitamin D, the women were classified into four groups: 25(OH)D≥30 μg·L-1 as sufficient group, 20 μg·L-1≤25(OH)D<30 μg·L-1 as insufficient group, 10 μg·L-1≤25(OH)D<20 μg·L-1 as the deficiency group, and<10 μg·L-1 as severe deficiency group. The association was determined between the serum 25(OH)D and thyroid autoantibodies and thyroid nodules. ResultsThe prevalence of deficiency in adult women was determined to be 69.31%. Alkaline phosphatase (ALP), low-density lipoprotein (LDL), anti-thyroglobulin antibodies (TGAB) and anti-thyroid peroxidase autoantibody (TPOAB) levels significantly differed between the severe deficiency group and sufficient group (each P<0.05). Moreover, prevalence of thyroid nodules, TGAB, TGAB and/or TPOAB differed significantly across the four groups (each P<0.05). Logistic regression analysis showed that decrease of serum 25(OH)D was significantly associated with age and increasing prevalence of thyroid nodules, TGAB, TGAB and/or TPOAB. ConclusionVitamin D deficiency remains high in adult women for health examination in Shanghai. Serum 25(OH)D insufficiency or deficiency is associated with age, thyroid autoantibodies and thyroid nodules.

2.
Arch. endocrinol. metab. (Online) ; 64(5): 542-547, Sept.-Oct. 2020. tab
Article in English | LILACS | ID: biblio-1131140

ABSTRACT

ABSTRACT Objective Warthin-like papillary thyroid cancer (WL-PTC) is an uncommon variant of PTC, usually associated with lymphocytic thyroiditis. Scarce evidence suggests that WL-PTC has similar clinical presentation to classic PTC (C-PTC), with no studies comparing risks of recurrence and response to treatment between both variants. Our objective was to describe the clinical presentation and prognosis of WL-PTC and compare it to C-PTC. Subjects and methods Retrospective analysis of a prospective cohort, including 370 (96%) patients with C-PTC and 17 (4%) with WL-PTC, consecutively treated with total thyroidectomy with or without RAI, followed for at least 6 months. We compared clinical presentation, risk of mortality and recurrence, as well as response to treatment between both variants. Results Of the total cohort: 317 (82%) female, 38 ± 13.5 years, median follow-up 4 years (0.5-28.5); most of them stage I and low/intermediate risk of recurrence. We found no differences regarding clinical-pathological data and risk of recurrence. WL-PTC was associated with a higher rate of anti-thyroglobulin antibodies (TgAb) (65% vs. 36%, p = 0.016) and lymphocytic thyroiditis (59% vs. 34%, p = 0.03). The rates of biochemical and structural incomplete responses were similar in both variants. WL-PTC had a lower rate of excellent response (23% vs. 54%, p = 0.01), which became non-significant when performing analysis by TgAb presence (50% vs. 67%, p = NS). Conclusions WL-CPT and C-CPT have similar clinical presentation and rate of recurrence. The lower rate of excellent response to treatment in WL-PTC is due to a higher frequency of TgAb. WL-PCT should not be considered an aggressive variant of PTC.


Subject(s)
Humans , Female , Thyroid Neoplasms/surgery , Carcinoma, Papillary , Prognosis , Thyroglobulin , Thyroidectomy , Prospective Studies , Retrospective Studies , Thyroid Cancer, Papillary , Neoplasm Recurrence, Local
3.
Arch. endocrinol. metab. (Online) ; 61(2): 108-114, Mar.-Apr. 2017. tab, graf
Article in English | LILACS | ID: biblio-838426

ABSTRACT

ABSTRACT Objectives The presence of thyroglobulin (Tg) in needle washouts of fine needle aspiration biopsy (Tg-FNAB) in neck lymph nodes (LNs) suspected of metastasis has become a cornerstone in the follow-up of patients with papillary thyroid carcinoma (PTC). However, there are limited data regarding the measurement of anti-Tg antibodies in these washouts (TgAb-FNAB), and it is not clear whether these antibodies interfere with the assessment of Tg-FNAB or whether there are other factors that would more consistently justify the finding of low Tg-FNAB in metastatic LNs. Materials and methods We investigated 232 FNAB samples obtained from suspicious neck LNs of 144 PTC patients. These samples were divided according to the patient’s serum TgAb status: sTgAb- (n = 203 samples) and sTgAb+ (n = 29). The TgAb-FNAB levels were measured using two different assays. Tg-FNAB was also measured using two assays when low levels (< 10 ng/mL) were identified in the first assay of the metastatic LNs from the sTgAb+ samples. Results The TgAb-FNAB results were negative in both assays in all samples. Low levels of Tg-FNAB were identified in 11/16 of the metastatic LNs of the sTgAb+ patients and 16/63 of the sTgAb- patients (p < 0.05) using assay 1. The measurement of the Tg-FNAB levels using assay 2 indicated additional metastases in 5 LNs of the sTgAb+ patients. Conclusions Factors other than the presence of TgAb-FNAB may contribute to the higher number of metastatic LNs with undetectable Tg-FNAB in the sTgAb+ group. In addition, the measurement of Tg-FNAB using different assays was useful to enhance the diagnosis of metastatic LNs, particularly when cytological and Tg-FNAB results are discordant.


Subject(s)
Humans , Autoantibodies/blood , Thyroglobulin/blood , Thyroid Neoplasms/blood , Carcinoma/blood , Lymph Nodes/immunology , Reference Values , Carcinoma/immunology , Carcinoma/pathology , Carcinoma, Papillary , Fluoroimmunoassay/methods , Predictive Value of Tests , Biopsy, Fine-Needle/instrumentation , Biopsy, Fine-Needle/methods , Lymph Nodes/pathology , Lymphatic Metastasis/immunology , Lymphatic Metastasis/pathology , Neck
4.
International Journal of Laboratory Medicine ; (12): 2426-2428, 2016.
Article in Chinese | WPRIM | ID: wpr-497445

ABSTRACT

Objective To investigate the application value of anti‐thyroid peroxidase antibodies(TPO‐Ab) ,thyroid stimulating hormone(TSH) ,anti‐thyroglobulin antibody(TGA) in screening thyroid disease among pregnant women .Methods A total of 125 pregnant women of thyroid nodule diagnosed by neck ultrasonography in our hospital from January 2014 to June 2015 were selected as the thyroid disease group ,other 120 pregnant women with no thyroid disease family history or past disease history by the routine antenatal examination were selected as the pregnant control group .And 100 non‐pregnant child‐bearing healthy women were select‐ed as the healthy control group .The levels of serum TPO‐Ab ,TSH and TGA ,and positive rate in each group were detected by u‐sing the chemiluminescence method .The receiver operation working(ROC) curve was adopted to evaluate the application value of TPO‐Ab ,TSH and TGA in screening early thyroid disease among pregnant women .Results The serum TPO‐Ab ,TSH and TGA levels and positive rate in the thyroid disease group were significantly higher than those in the pregnant control group and healthy control group(P<0 .05) ,the ROC curve analysis showed that the sensitivity from high to low were TPO‐Ab ,TSH and TGA ;the specificity from high to low were TPO‐Ab ,TSH ,TGA ;the sensitivity and specificity in TPO‐Ab ,TSH and TGA combined diagno‐sis were higher than those in single index diagnosis .Conclusion TPO‐Ab ,TSH and TGA can be used as diagnostic indicators for pregnant women thyroid disease ,the joint diagnosis method can increase their clinical application value .

5.
Annals of Pediatric Endocrinology & Metabolism ; : 179-182, 2013.
Article in English | WPRIM | ID: wpr-10174

ABSTRACT

PURPOSE: It has been reported that antithroglobulin (anti-TG) antibody is increased in the sera of both children with transient congenital hypothyroidism and their mothers. And transplacental transport of thyroid autoantibody was proposed as the pathogenesis of transient congenital hypothyroidism. However this is not known in nontransient congenital hypothyroidism. This study was done to see changes of anti-TG antibody in children with nontransient congenital hypothyroidism. METHODS: Study patients consisted of 60 patients diagnosed as congenital hypothyroidism in the Department of Pediatrics, Kyungpook National University Children's Hospital, Daegu, Republic of Korea between January 2010 and March 2013. Healthy control were 45 children showing normal thyroid function. Anti-TG antibody and various laboratory tests were analyzed retrospectively, and compared in both children with congenital hypothyroidism and controls. RESULTS: Anti-TG antibody was significantly higher in children with congenital hypothyroidism compared to healthy controls, 119.4+/-34.7 U/mL versus 80.6+/-19.6 U/mL, respectively (P<0.001). There was no significant difference of anti-TG antibody in gender and age. CONCLUSION: We observed a significant increase of anti-TG antibody in children with nontransient congenital hypothyroidism compared to healthy controls. Further study focusing pathogenetic role of anti-TG antibody in nontransient congenital hypothyroidism is necessary. Furthermore, the clinical significance in the course of congenital hypothyroidism need to be known.


Subject(s)
Child , Humans , Autoantibodies , Congenital Hypothyroidism , Mothers , Pediatrics , Republic of Korea , Retrospective Studies , Thyroid Gland
6.
Laboratory Medicine Online ; : 35-42, 2011.
Article in Korean | WPRIM | ID: wpr-178809

ABSTRACT

BACKGROUND: Measurements of serum anti-thyroglobulin antibody (anti-Tg) and anti-thyroid peroxidase antibody (anti-TPO) are important for the diagnosis of autoimmune thyroid diseases. Although ELISA is most commonly used for the detection of anti-thyroid autoantibodies, other methods like particle agglutination assay (PA) or radioimmunoassay (RIA) are still being used in clinical laboratories. There are few studies about the comparison between PA and ELISA, and we evaluated the validity of these assays in this study. METHODS: We have used three methods, PA (Fujirebio Inc.), ELISA-1 (Zeus Scientific Inc.), and ELISA-2 (Orgentec Diagnostika) for the measurements of titers or concentrations of anti-thyroid autoantibodies. A total of 212 patients belonging to six different disease groups were tested: 40 patients for anti-Tg only, 64 for anti-TPO (or anti-microsome) only, and 108 for both antibodies. All test results were compared with each other in six disease groups. RESULTS: Concordance of positive or negative results was obtained in 78.5-97.3% of the samples tested, and positive rates of three methods were similar in autoimmume thyroid disease group. In the comparable concentration range, the correlation coefficients were 0.328-0.820 between the two ELISAs or between ELISA and PA. CONCLUSIONS: Positive or negative decisions by three assay systems have high concordance rates, and antibody levels measured by three methods correlate well in the comparable concentration range. The ELISA-1 shows less non-specific reactions, better discrimination in low level of autoantibodies, and the highest positive rate in autoimmume thyroid disease group.


Subject(s)
Humans , Agglutination , Antibodies , Autoantibodies , Discrimination, Psychological , Enzyme-Linked Immunosorbent Assay , Peroxidase , Radioimmunoassay , Thyroid Diseases
7.
Journal of the Korean Ophthalmological Society ; : 1167-1173, 2010.
Article in Korean | WPRIM | ID: wpr-42502

ABSTRACT

PURPOSE: The same autoimmune process is thought to cause thyroid associated ophthalmopathy (TAO) and Graves' disease. The aim of this study is to determine hether thyroid autoantibody is related to the development of thyroid associated ophthalmopathy. METHODS: A retrospective chart analysis was performed on patients with a newly diagnosed Graves' disease, who presented to our ophthalmology clinic between January 2006 and December 2009. Thyroid autoantibody titers were obtained at the time of diagnosis and were used to determine the presence or absence of TAO. In addition, any correlations between thyroid autoantibodies were analyzed in patients with TAO. RESULTS: Thyroid autoantibody levels correlated with the development of TAO. Fifty-eight (69%) out of 84 patients with positive thyroid-stimulating hormone receptor antibody (TRAB) levels at the time of diagnosis had TAO. Only 50 (51%) of the 99 patients with negative TRAB levels had TAO. This difference between the two groups was statistically significant (odds ratio, OR=2.2, p=0.013). A statistically significant correlation with the development of TAO was also found in thyroid peroxidase antibody (TPOAb) and anti-thyroglobulin antibody (TgAb), respectively (OR=0.5, p=0.317; OR=0.3, p=<0.001). In patients with TAO, the correlation between TPOAb and TgAb levels was very high (r=0.64, p=<0.001). CONCLUSIONS: A significant association was determined to exist between the development of TAO and thyroid autoantibody level. This result demonstrates the clinical utility of thyroid autoantibody for the diagnosis of TAO in patients with newly diagnosed Graves' disease.


Subject(s)
Humans , Autoantibodies , Graves Disease , Graves Ophthalmopathy , Iodide Peroxidase , Ophthalmology , Retrospective Studies , Thyroid Gland , Thyrotropin , Troleandomycin
8.
Korean Journal of Nuclear Medicine ; : 252-256, 2005.
Article in Korean | WPRIM | ID: wpr-115916

ABSTRACT

PURPOSE: Thyroglobulin (Tg) is a valuable and sensitive tool as a marker for diagnosis and follow-up for several thyroid disorders, especially, in the follow-up of patients with differentiated thyroid cancer (DTC). Often, clinical decisions rely entirely on the serum Tg concentration. But the Tg assay is one of the most challenging laboratory measurements to perform accurately owing to antithyroglobulin antibody (Anti-Tg). In this study, we have compared the degree of Anti-Tg effects on the measurement of Tg between availale Tg measuring kits. MATERIALS AND METHODS: Measurement of Tg levels for standard Tg solution was performed with two different kits commercially available (A/B kits) using immunoradiometric assay technique either with absence or presence of three different concentrations of Anti-Tg. Measurement of Tg for patient's serum was also performed with the same kits. Patient's serum samples were prepared with mixtures of a serum containing high Tg levels and a serum containg high Anti-Tg concentrations. RESULTS: In the measurements of standard Tg solution, presence of Anti-Tg resulted in falsely lower Tg level by both A and B kits. Degree of Tg underestimation by A kit was more prominent than B kit. The degree of underestimation by B kit was trivial therefore clinically insignificant, but statistically significant. Addition of Anti-Tg to patient serum resulted in falsely lower Tg levels with only A kit. CONCLUSION: Tg level could be underestimated in the presence of anti-Tg. Anti-Tg effect on Tg measurement was variable according to assay kit used. Therefore, accuracy test must be performed for individual Tg-assay kit.


Subject(s)
Humans , Diagnosis , Follow-Up Studies , Immunoradiometric Assay , Thyroglobulin , Thyroid Gland , Thyroid Neoplasms
9.
Journal of Korean Society of Endocrinology ; : 42-47, 2004.
Article in Korean | WPRIM | ID: wpr-173604

ABSTRACT

BACKGROUND: Serum thyroglobulin(Tg) is a valuable and sensitive tool needed in the follow-up of patients with differentiated thyroid cancer(DTC), but antithyroglobulin antibody(Anti-Tg), common in patients with DTC, can interfere with the assay for Tg. In this study, we evaluated the influence of Anti-Tg on the measurement of Tg using the immunoradiometric assay(IRMA). METHODS: In using ELSA-hTg in vivo test(CIS international, Schering, France), a solid phase two-site IRMA was used to measure Tg(23.5ng/mL, 62.5ng/mL) under the absence or presence of three concentrations of Anti-Tg(25U/mL, 50U/mL, 100U/mL). We also performed Tg measurement using patients serum that was mixed with patients serum containing high Anti-Tg. ANOVA and Scheffe tests were performed to evaluate the effect of Anti-Tg on Tg IRMA, and an inverse regression was made to calculate the level of Tg from measured Tg and used Anti-Tg levels and also to assess the degree of effect of anti-Tg on Tg IRMA. RESULTS: In measuring Tg using the standard solution, the presence of Anti-Tg resulted in a falsely suppressed Tg value. The IRMAs for 23.5ng/mL of the standard Tg solution resulted in 24.5+/-.1 ng/mL under no Anti-Tg, 11.8+/-.4ng/mL under 25U/mL of Anti-Tg, 7.7+/-.1ng/mL under 50U/mL of Anti-Tg, and 4.5+/-.4ng/mL under 100U/mL of Anti-Tg. IRMAs 62.5ng/mL of the standard Tg solution resulted in 65.9+/-.7ng/mL under no Anti-Tg, 36.3+/-.2ng/mL under 25U/mL of Anti-Tg, 23.7+/-.7ng/mL under 50U/mL of Anti-Tg, and 14.0+/-.0ng/mL under 100U/mL of Anti-Tg. (ANOVA test, p=0.000). The degree of suppression of the measured Tg value was positively correlated with the Anti-Tg level (Quadratic model regression, Sig T=0.000). The presence of Anti-Tg also resulted in a falsely suppressed Tg value for the Tg measurement using patient's serum. CONCLUSION: The presence of Anti-Tg could consist of the use of Tg as a tumor, therefore Anti-Tg should be measured in all patients diagnosed with DTC. The interpretation of the Tg level must be performed with extreme caution in patients with Anti-Tg.


Subject(s)
Humans , Immunoradiometric Assay , Thyroglobulin , Thyroid Gland
10.
Journal of Korean Society of Endocrinology ; : 339-350, 1998.
Article in Korean | WPRIM | ID: wpr-184983

ABSTRACT

BACKGROUND: Postpartum thyroiditis(PPT) is one of syndromes of thyroid dysfunction that occurs in the first year after parturition. Reported incidence of PPT is 3.9-8.2% of postpartum women in several studies from different countries. The fact that 52-100% of patients with PPT have thyroid autoantibodies, and that lymphocytic infiltration of thyroid gland is the characteristic pathological feature of PPT suggest that PPT is an autoimmune disease. High iodine intake in short term period is known to aggrevate the experimental autoimmune thyroiditis. This study was performed to investigate the incidence and clinical features of PPT in Korean postpartum women who usually ingest excessive amount of idine in immediate postpartum period and to investigate the predictive value of thyroid autoantibodies in the development of PPT in them. METHOD: Between March 1996 and February 1997, 99 women without previous history of any thyroid disease who delivered babies at Boramae hospital were enrolled. Thyroid function parameters(T3, T4, free T4, TSH), thyroid autoantibodies(anti-microsomal antibody, anti-thyroglobulin antibody) and urinary iodine excretion were measured prospectively before and 1, 3 months after delivery. Dietary iodine intake during postpartum period was evaluated by questionnaire, and clinical parameters were followed up. RESULTS: During 3 months of observation, PPT developed in 8.1%(8/99) of postpartum women. Five cases had typical course having thyrotoxic phase and the other 3 cases had hypothyroid phase without toxic phase. However, only one of those required thyroid hormone replacement therapy in the latter group. There were no differences in age, baseline thyroid function parameters, parity, percent cases with family history of thyroid disease between those developed PPT (n=8) and those did not develop PPT(n=91). Duration of high iodine intake(3.8 +- 0.5 wk. vs. 3.7 +- 0.8 wk., p>0.05), total ingested amount of high iodine diet(77 +- 28 vs. 79 +- 24 bowels of miyokguk, p)0.05), and the urinary iodine excretion(1.9 +- 1.4 mg/g creatinine vs. 3.7 +- 3.7mg/g creatinine, p0.05) at 1 month postpartum were not different between two groups. Of 99 total subjects, anti-microsomal antibody(AMA) was present in 13.1%(13/99) before delivery in their sera. Positive predictive value of the presence of AMA before delivery in predicting the development of PPT was 30.8%. CONCLUSION: The fact that incidence of PPT in normal Korean postpartum women who usually have high iodine intake in immediate postpartum period is not higher than those of other countries, and that there was no difference in the amount of iodine intake between those developed PPT and those did not suggest that high iodine intake in immediate postpartum period do not influence on the incidence of PPT. The presence of AMA before delivery had low specificity in prediction of development of PPT, so the measurement of AMA seems not to be a useful screening test.


Subject(s)
Female , Humans , Autoantibodies , Autoimmune Diseases , Creatinine , Hormone Replacement Therapy , Incidence , Iodine , Mass Screening , Parity , Parturition , Postpartum Period , Postpartum Thyroiditis , Prospective Studies , Surveys and Questionnaires , Sensitivity and Specificity , Thyroid Diseases , Thyroid Gland , Thyroiditis, Autoimmune
SELECTION OF CITATIONS
SEARCH DETAIL