Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 65
Filter
1.
Rev. gastroenterol. Perú ; 44(1): 67-70, ene.-mar. 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1560051

ABSTRACT

ABSTRACT Acute gastric variceal bleeding is a life-threatening condition that could be effectively treated with endoscopic cyanoacrylate injection diluted with lipiodol. The mixture acts as a tissue adhesive that polymerizes when in contact with blood in a gastric varix. This work reports a patient that presented to the emergency department with upper gastrointestinal bleeding due to acute variceal bleeding, who developed systemic embolization following cyanoacrylate injection therapy. This complication culminated in cerebral, splenic and renal infarctions with a fatal outcome. Systemic embolization is a very rare, but the most severe complication associated with endoscopic cyanoacrylate injection and should be considered in patients undergoing this treatment.


RESUMEN La hemorragia digestiva por várices gástricas es una afección potencialmente mortal que puede tratarse eficazmente con la inyección endoscópica de cianoacrilato diluida con lipiodol. La mezcla actúa como un adhesivo tisular que se polimeriza cuando entra en contacto con la sangre de la várice gástrica. Este trabajo nos reporta un paciente que acudió al servicio de urgencias con hemorragia digestiva alta debido a hemorragia aguda por várices, que desarrolló embolización sistémica después de la terapia con inyección de cianoacrilato. Esta complicación culminó en infartos cerebrales, esplénicos y renales con desenlace fatal. La embolización sistémica es una complicación muy rara, pero con alta mortalidad, asociada con la inyección endoscópica de cianoacrilato y debe considerarse en pacientes sometidos a este tratamiento.

2.
Rev. bras. oftalmol ; 83: e0057, 2024. graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1576096

ABSTRACT

RESUMO Paciente sexo masculino, 46 anos, portador de ceratocone avançado, evoluiu com hidropsia e perfuração corneana considerada pequena. Inicialmente, foi realizado tamponamento da perfuração com cola de cianoacrilato e lente de contato terapêutica, porém, o ceratocone avançado não permitia estabilização adequada da lente de contato, e o paciente evoluiu com dor intensa, inviabilizando a manutenção da cola de cianoacrilato. Foi indicada, então, a realização de injeção intraestromal de sangue autólogo no centro cirúrgico ambulatorial, que foi efetiva para conter a perfuração. Após melhora do quadro de hidropsia, o paciente foi submetido ao transplante corneano penetrante para reabilitação visual.


ABSTRACT A 46-year-old male who was already diagnosed with keratoconus presented with hydrops followed by a small corneal perforation. At first, the perforation was managed with a cyanoacrylate glue and therapeutic contact lens; however, the advanced keratoconus did not allow stabilization of the contact lens, and the patient developed intense pain, making it impossible to maintain the cyanoacrylate glue. An intrastromal injection of autologous blood was then performed at the operating room, which was effective in containing the perforation. After the hydrops condition improved, the patient underwent penetrating corneal transplantation for visual rehabilitation.

3.
Article | IMSEAR | ID: sea-218904

ABSTRACT

The use of root coverage procedures to treat gingival recession defects, a common periodontal condition, is an important aspect of periodontal regenerative therapy. The synergistic relationship between vascular configuration and involved tissues is the most important factor in soft tissue graft success. The present case reports the clinical effectiveness of Gingival Unit Graft (GUG) for the management of Miller's class III gingival recession.Clinical parameters like Probing depth, recession depth, keratinized tissue width and clinical attachment level were measured at baseline and postoperative 6 months. Percentage of defect coverage was evaluated at postoperative 6 months. Healing was uneventful and 3mm root coverage was observed with 1mm residual recession and increase in keratinized gingiva after 6 months follow up. Free soft tissue autografts such as gingival unit transfers can be used along with bio-adhesives such as cyanoacrylates for predictable results in the management of recession defects.

4.
Int. j interdiscip. dent. (Print) ; 14(2): 191-193, ago. 2021. tab, ilus
Article in English | LILACS | ID: biblio-1385214

ABSTRACT

ABSTRACT: A variety of periodontal plastic surgery techniques have been proposed to correct aesthetic and functional problems caused by gingival recession, with root coverage using connective tissue grafts being the one most commonly performed. These surgeries, however, are partially dependent on tissue graft stability. In this case series, we describe the use of a tissue adhesive (cyanoacrylate) as a solution for graft stabilization. Two patients with Cairo's type 1 gingival recession were treated with an envelope technique using connective tissue graft stabilized with cyanoacrylate alone. The results were a faster procedure and complete root coverage, even after 5 years of follow-up. Our findings suggest that cyanoacrylates can be an alternative to standard graft stabilizing procedures, leading to a stable root coverage in RT1 recessions.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Tissue Adhesives/therapeutic use , Cyanoacrylates/therapeutic use , Gingival Recession/therapy , Treatment Outcome , Connective Tissue/transplantation
5.
Acta Paul. Enferm. (Online) ; 34: eAPE02724, 2021. tab
Article in Portuguese | LILACS, BDENF | ID: biblio-1349810

ABSTRACT

Resumo Objetivo Descrever o uso da cola cirúrgica no reparo do trauma perineal no parto normal. Métodos Estudo série de casos realizado em três momentos (até 2 horas, 12-24 horas e 36-48 horas após o parto), em Itapecerica da Serra, SP. Foram incluídas mulheres que tiveram parto normal com trauma perineal com indicação de sutura (laceração de primeiro ou segundo graus e episiotomia). O trauma perineal foi reparado exclusivamente com cola cirúrgica Glubran-2®. Avaliou-se: intensidade da dor perineal (Escala Visual Numérica com 11 pontos), processo de cicatrização (escala REEDA de 15 pontos), satisfação com o reparo (escala Likert de 5 pontos). Os dados foram analisados de forma descritiva e inferencial comparando os três momentos. Resultados A técnica de aplicação da cola e a quantidade necessária foram definidas em uma amostra de 19 mulheres. Destas, 78,9% tiveram laceração de primeiro grau, 15,8% de segundo grau e 5,3% episiotomia. Os desfechos nos momentos 1, 2 e 3, foram respectivamente: ausência de dor (73,6%, 94,7% e 89,4%); escore ≤1 na escala REEDA (94,7%, 78,9% e 84,2%); 100% satisfeitas com o reparo em todos os momentos. Não houve diferença pelo teste de Friedman para dor e satisfação. O processo de cicatrização mostrou diferença, porém sem confirmação no pós-teste hoc. Conclusão A aplicação da cola mostrou-se viável para avaliação em uma amostra maior de mulheres, pois os resultados sugerem boa aceitação pelas mulheres e dor de baixa intensidade ou ausente, cicatrização adequada e alta satisfação com o reparo nas primeiras 48 horas após o parto.


Resumen Objetivo Describir el uso de pegamento quirúrgico para reparar traumas perineales en partos vaginales. Métodos Estudio serie de casos realizado en tres momentos (hasta 2 horas, de 12 a 24 horas y de 36 a 48 horas después de parto), en Itapecerica da Serra, estado de São Paulo. Se incluyeron mujeres que tuvieron parto vaginal con trauma perineal e indicación de sutura (desgarro de primer o segundo grado y episiotomía). El trauma perineal fue reparado exclusivamente con pegamento quirúrgico Glubran-2®. Se evaluó la intensidad del dolor perineal (Escala Visual Numérica de 11 puntos), el proceso de cicatrización (Escala REEDA de 15 puntos) y la satisfacción respecto a la reparación (Escala Likert de 5 puntos). Los datos fueron analizados de forma descriptiva e inferencial, comparando los tres momentos. Resultados La técnica de aplicación del pegamento y la cantidad necesaria fueron definidas en una muestra de 19 mujeres. De ellas, el 78,9 % tuvieron un desgarro de primer grado, el 15,8 % de segundo grado y el 5,3 % episiotomía. Los resultados de los momentos 1, 2 y 3 fueron, respectivamente: ausencia de dolor (73,6 %, 94,7 % y 89,4 %); puntuación ≤1 en la escala REEDA (94,7 %, 78,9 % y 84,2 %); 100 % satisfechas con la reparación en todos los momentos. No se observó diferencia de dolor y satisfacción con la prueba de Friedman. El proceso de cicatrización mostró diferencia, pero sin confirmación en la prueba post hoc. Conclusión La aplicación del pegamento demostró ser viable para un análisis con una muestra mayor de mujeres, ya que los resultados sugieren buena aceptación por parte de las mujeres, dolor de baja intensidad o ausente, cicatrización adecuada y alta satisfacción respecto a la reparación en las primeras 48 horas después del parto.


Abstract Objective To describe the use of surgical glue to repair perineal trauma during normal delivery. Methods This is a case series study, which was carried out in three moments (up to 2 hours, 12-24 hours and 36-48 hours after delivery) in Itapecerica da Serra, SP. Women who had a normal delivery with perineal trauma with a suture (first or second degree laceration and episiotomy) were included. Perineal trauma was repaired exclusively with Glubran-2® surgical glue. Perineal pain intensity (11-point Visual Numeric Scale), healing process (15-point REEDA scale), satisfaction with repair (5-point Likert scale) were assessed. Data were analyzed in a descriptive and inferential way comparing the three moments. Results The technique of applying the glue and the required amount were defined in a sample of 19 women. Of these, 78.9% had first-degree lacerations, 15.8%, second-degree lacerations and 5.3%, episiotomy. The outcomes at moments 1, 2 and 3 were absence of pain (73.6%, 94.7% and 89.4%), score ≤1 on the REEDA scale (94.7%, 78.9% and 84, two%); 100% were satisfied with the repair at all times. There was no difference by the Friedman test for pain and satisfaction. The healing process showed a difference, but without confirmation in the hoc post-test. Conclusion The glue application proved to be viable for assessment in a larger sample of women, as the results suggest good acceptance by women and low or no pain, adequate healing and high satisfaction with the repair in the first 48 hours after delivery.


Subject(s)
Humans , Female , Perineum/injuries , Tissue Adhesives , Lacerations/therapy , Postpartum Period , Obstetric Nursing
6.
Rev. méd. Chile ; 148(11)nov. 2020.
Article in Spanish | LILACS | ID: biblio-1389251

ABSTRACT

In patients with actively bleeding gastric varices, the treatment of choice is the endoscopic use of sclerosing agents such as cyanoacrylate. We report a 69-year-old man who, after being treated with cyanoacrylate, suffered from recurrent febrile episodes. After an extensive study and broad-spectrum antibiotic treatment, discarding other presumably infectious focus, the superinfection of the cyanoacrylate plug was suspected, and its surgical removal was decided. A partial gastrectomy of the gastric fundus, a splenectomy, and a distal pancreatectomy were performed. The patient evolved without fever and without new episodes of bacteremia, but with decompensation of his cirrhosis manifested by ascites, spontaneous bacterial peritonitis, pneumonia, and collections in the pancreatic bed. These complications were managed with medical treatment consisting in a long course of broad-spectrum antibiotics. Thereafter, the patient evolved satisfactorily.


Subject(s)
Aged , Humans , Male , Esophageal and Gastric Varices , Cyanoacrylates , Sclerosing Solutions/therapeutic use , Gastrointestinal Hemorrhage/drug therapy , Liver Cirrhosis
7.
São Paulo med. j ; São Paulo med. j;138(2): 98-105, Mar.-Apr. 2020. tab
Article in English | LILACS, SES-SP | ID: biblio-1139675

ABSTRACT

ABSTRACT BACKGROUND: Diagnosis and treatment of small saphenous vein (SSV) insufficiency is of utmost importance for relieving chronic venous insufficiency symptoms. OBJECTIVES: To investigate the efficacy and safety of five different treatment approaches among patients with SSV insufficiency. DESIGN AND SETTING: Two-center retrospective clinical study, conducted at cardiovascular surgery clinics in a local training and research hospital and a state hospital. METHODS: A total of 282 extremities of 268 patients with SSV insufficiency alone who were treated for symptomatic varicose veins between January 2012 and January 2017 were included in the study. All extremities included in the study were divided into five groups as follows: high ligation + stripping; radiofrequency ablation (RFA); cyanoacrylate closure (CAC); and endovenous laser ablation (EVLA) at the wavelengths 980 nm and 1,470 nm. RESULTS: Although the recurrence rate at six months was similar among the treatment groups, we found significant differences in recurrence rates at one year, with lower rates in the CAC, RFA and 1,470 nm EVLA groups, compared with the other treatments (P = 0.005). No sural neuritis was observed in the CAC group. The pigmentation rate was higher in the two EVLA groups (980 nm and 1,470 nm). CONCLUSIONS: Our study results showed that although CAC, RFA and EVLA at 1,470 nm seemed to be effective methods for treating SSV insufficiency alone, CAC and RFA had better aesthetic results than EVLA at 1,470 nm. We consider that endovenous non-thermal techniques for treating SSV insufficiency may be preferable because of relatively low risk of nerve injury.


Subject(s)
Humans , Varicose Veins , Venous Insufficiency , Saphenous Vein , Retrospective Studies , Treatment Outcome
8.
Rev. gastroenterol. Perú ; 39(3)jul. 2019.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1508549

ABSTRACT

Objetivo: Evaluar el éxito de la terapia endoscópica con N-butil-2-cianoacrilato sobre las várices gástricas y determinar las tasas de resangrado y mortalidad. Materiales y métodos: Estudio observacional prospectivo de 47 casos de pacientes con várices gástricas que fueron tratados con N-butil-2-cianoacrilato, utilizando una dilución 1:1 con lipiodol entre febrero de 2013 a marzo de 2017 en un hospital público de nivel III en Lima- Perú. La indicación terapéutica fue hemorragia activa, profilaxis primaria o secundaria. Resultados: De los 47 pacientes, 5 (10,6%) presentaban hemorragia activa, se obtuvo control de la misma en todos los casos, 24 (51,1%) tuvieron estigmas de sangrado reciente durante la endoscopía. Se realizó profilaxis secundaria en 16 (34%) pacientes y profilaxis primaria en 2 (4,7%), 59,6% requirió una sola sesión. El volumen total de cianoacrilato (ml/paciente) promedio fue 1,28 ± 0,44. Se aplicó una sola inyección por sesión en el 87,2% de los pacientes. El hallazgo endoscópico fue GOV-2 en el 78,7% de los casos, IGV-1 en el 12,8% y GOV-1 en el 8,5%. Siete pacientes (14,8%) presentaron resangrado tardío, con nueva terapia exitosa en 6 de ellos, uno fallece por fracaso de la terapia. Seis (12,76%) pacientes fallecen en total, cinco (83,3%) por otras causas. Se realizó 18 meses de seguimiento. No se reportaron eventos adversos relacionados con la terapia. Se constata obturación en 28 (59,5%) pacientes. Conclusiones: El manejo endoscópico de várices gástricas con cianoacrilato es un tratamiento seguro y eficaz, con baja tasa de recurrencia y mortalidad.


Objective: To evaluate the therapeutic success of endoscopic therapy with N-butyl-2-cyanoacrylate and to determine the rebleeding and mortality rates. Materials and methods: Prospective analytical observational study of 47 cases of patients with gastric varices who were treated with N-butyl-2-cyanoacrylate, using a 1: 1 mixture with lipiodol between 2013 and 2017 in a level III public hospital in Lima - Peru. The therapeutic indication was active hemorrhage, primary or secondary prophylaxis. Results: Of the 47 patients, 5 (10.6%) had active hemorrhage, control was obtained in all cases, 24 (51.1%) had stigmas of recent bleeding during endoscopy. Secondary prophylaxis was performed in 16 (34%) patients and primary prophylaxis in 2 (4.7%). 59.6% required a single session with a total volume of cyanoacrylate (ml / patient) of 1.28 ± 0.44. The endoscopic finding was GOV-2 in 78.7% of the cases, IGV-1 in 12.8% and GOV-1 in 8.5%. Seven patients (14.8%) presented late rebleeding, with successful new therapy in 6 of them, one dying due to therapy failure. Of the six (12.76%) patients who died in total, 5 (83.3%) were due to other causes. No adverse events related to the therapy were reported. No adverse events were reported. Variceal obturation was observed in 28 (59.5%) patients. Conclusions: Endoscopic management of gastric varices with cyanoacrylate is a safe and effective treatment, with low recurrence and mortality rates.

9.
Braz. dent. j ; Braz. dent. j;30(3): 266-271, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1011545

ABSTRACT

Abstract The aim of this study was to verify whether modifications made in a hard chairside reline resin by an ethyl-cyanoacrylate adhesive, ECA (Super Bonder®, Loctite, Itapevi, SP, Brazil) would be able to inhibit or reduce Candida albicans biofilm formation on its surface, comparing to a commercial surface sealant (BisCover®, Bisco, Schaumburg, USA). Reline resin specimens were fabricated and randomly divided into 6 groups (n=8): CG (control group), no surface treatment; ECA1, ECA coating on the surface before sterilization; ECA2, ECA coating after sterilization; ECA3, ECA incorporated in the resin bulk; DPE1, BisCover® coating before sterilization; DPE2, BisCover® coating after sterilization. Specimens were inoculated with C. albicans SC5314 (1x107 cells/mL) and incubated for 24 h. Then, the biofilm were stained with LIVE/DEAD® BaclightTM L7007 Kit and analyzed by Confocal Laser Scanning Microscopy. The images were evaluated by bioImageL® v.2.0 software and total biovolume (µm3), viable cells (%), and covered area (%) were calculated. Data were statistically analyzed by Kruskal-Wallis and Dunn tests (p<0.05). Results showed that ECA-coated groups presented better results, reducing C. albicans biofilm formation. Acquired images revealed that these groups (ECA1 and ECA2) presented a reduced number of cells, mostly in yeast form (less pathogenic), while the other groups presented higher number of cells, mostly in hyphae form (more pathogenic). Based on these findings, a beneficial effect of Super Bonder® coating reline resins surface could be demonstrated, suggesting a promising way to prevent fungal biofilm formation on dentures.


Resumo O objetivo deste estudo foi verificar se as modificações feitas com o adesivo etil cianoacrilato, ECA (Super Bonder ®, Loctite, Itapevi, SP, Brasil) sobre as resinas acrílicas para reembasamento, poderiam inibir ou reduzir a formação de biofilmes de C.albicans sobre sua superfície quando comparado com um selante de superfície comercial (BisCover®, Bisco, Schaumburg, EUA). Amostras de resina acrílica para reembasamento foram fabricadas e divididas aleatoriamente em 6 grupos (n=8): CG (grupo controle), sem tratamento superficial; ECA1, revestimento de ECA na superfície antes da esterilização; ECA2, revestimento de ECA após esterilização; ECA3, ECA incorporado no volume da resina; DPE1, revestimento de BisCover® antes da esterilização; DPE2, revestimento de BisCover® após esterilização. Os espécimes foram inoculados com C. albicans SC5314 (1x107 células/mL) e incubados durante 24 h. Seguidamente, o biofilme foi corado com LIVE/DEAD® BaclightTM L7007 Kit e analisado no microscópio confocal de varredura a laser. As imagens foram avaliadas pelo software bioImageL® v.2.0, no qual foram calculados o biovolume total (μm3), as células viáveis (%) e a área coberta (%). Os dados foram analisados estatisticamente pelos testes de Kruskal-Wallis e Dunn (p<0,05). Os resultados mostraram que os grupos revestidos com ECA apresentaram os melhores resultados, reduzindo a formação do biofilme de C. albicans. As imagens adquiridas revelaram que esses grupos (ECA1 e ECA2) apresentaram um número reduzido de células, principalmente na forma de levedura (menos patogênico), enquanto os outros grupos apresentaram um maior número de células, principalmente na forma de hifas (mais patogênicas). Com base nessas descobertas, encontra-se um efeito benéfico na aplicação do adesivo ECA sobre as superfícies das resinas acrílicas para reembasamento, sugerindo assim uma nova alternativa de prevenir a formação de biofilme fúngico em próteses dentárias.


Subject(s)
Candida albicans , Denture Bases , Surface Properties , Acrylic Resins , Brazil , Biofilms , Cyanoacrylates
10.
Arq. gastroenterol ; Arq. gastroenterol;56(1): 99-105, Jan.-Mar. 2019. tab, graf
Article in English | LILACS | ID: biblio-1001334

ABSTRACT

ABSTRACT BACKGROUND: One of the most feared complications with the use of cyanoacrylate for treatment of gastric varices is the occurrence of potentially life-threatening systemic embolism. Thus, endoscopists are turning towards new techniques, including endoscopic coiling, as a potentially safer and more effective treatment option. However, no studies have been performed comparing the two techniques. OBJECTIVE: This study aims to compare the safety and efficacy of endoscopic ultrasound guided coil and cyanoacrylate injection versus the conventional technique of injection of cyanoacrylate alone. DESIGN: A pilot randomized controlled trial. METHODS: Patients randomized into group I were treated with coil and cyanoacrylate, and those in group II with cyanoacrylate alone. Flow within the varix was evaluated immediately after the treatment session and one month following initial treatment. If thrombosis was confirmed, additional follow-up was performed 4 and 10 months following initial treatment. All patients underwent a thoracic computerized tomography scan after the procedure. RESULTS: A total of 32 patients, 16 in each group, were followed for an average of 9.9 months (range 1-26 months). Immediately after the procedure, 6 (37.5%) group-I patients and 8 (50%) group-II patients presented total flow reduction in the treated vessel (P=0.476). After 30 days, 11 (73.3%) group-I patients and 12 (75%) group-II patients were found to have varix thrombosis. In both groups, the majority of patients required only one single session for varix obliteration (73.3% in group I versus 80% in group II). Asymptomatic pulmonary embolism occurred in 4 (25%) group-I patients and 8 (50%) group-II patients (P=0.144). No significant difference between the groups was observed. CONCLUSION: There is no statistical difference between endoscopic ultrasound guided coils plus cyanoacrylate versus conventional cyanoacrylate technique in relation to the incidence of embolism. However, a greater tendency towards embolism was observed in the group treated using the conventional technique. Both techniques have similar efficacy in the obliteration of varices. Given the small sample size of our pilot data, our results are insufficient to prove the clinical benefit of the combined technique, and do not yet justify its use, especially in light of higher cost. Further studies with larger sample size are warranted.


RESUMO CONTEXTO: Uma das complicações mais temidas com o uso de cianoacrilato para tratamento de varizes gástricas é a ocorrência de embolia sistêmica potencialmente fatal. Assim, os endoscopistas estão se aprimorando com novas técnicas, incluindo o uso de coils endoscópico, como uma opção de tratamento potencialmente mais segura e eficaz. No entanto, nenhum estudo foi realizado comparando as duas técnicas. OBJETIVO: Este estudo tem como objetivo comparar a segurança e eficácia da injeção de coil com cianoacrilato guiados por ultrassom endoscópico versus a técnica convencional de injeção de cianoacrilato. DESIGN: Um ensaio piloto controlado aleatoriamente. MÉTODOS: Os pacientes randomizados para o grupo I foram tratados com coil + cianoacrilato e os do grupo II apenas com cianoacrilato. O fluxo dentro da variz foi avaliado imediatamente após a sessão de tratamento e um mês após o tratamento inicial. Se a trombose foi confirmada, o acompanhamento adicional era realizado em 4 e 10 meses após o tratamento inicial. Todos os pacientes foram submetidos a uma tomografia computadorizada torácica após o procedimento. RESULTADOS: Um total de 32 pacientes, 16 em cada grupo, foram acompanhados por uma média de 9,9 meses (variação de 1-26 meses). Imediatamente após o procedimento, 6 (37,5%) pacientes do grupo I e 8 (50%) pacientes do grupo II apresentaram redução total do fluxo no vaso tratado (P=0,476). Após 30 dias, 11 (73,3%) pacientes do grupo I e 12 (75%) pacientes do grupo II apresentaram trombose da variz. Em ambos os grupos, a maioria dos pacientes necessitou de apenas uma única sessão para obliteração da variz (73,3% no grupo I versus 80% no grupo II). Embolia pulmonar assintomática ocorreu em 4 (25%) pacientes do grupo I e em 8 (50%) pacientes no grupo II (P=0,144). Nenhuma diferença significativa entre os grupos foi observada. CONCLUSÃO Apesar de não haver diferença estatística entre os dois grupos em relação à incidência de embolia neste estudo piloto, observou-se maior tendência de embolia no grupo tratado pela técnica convencional.


Subject(s)
Humans , Male , Female , Adult , Aged , Esophageal and Gastric Varices/therapy , Cyanoacrylates/administration & dosage , Pulmonary Embolism/etiology , Esophageal and Gastric Varices/diagnostic imaging , Injections, Intralesional/adverse effects , Injections, Intralesional/methods , Pilot Projects , Treatment Outcome , Hemostasis, Endoscopic/methods , Ethiodized Oil/administration & dosage , Endosonography/methods , Middle Aged
11.
Acta cir. bras ; Acta cir. bras;34(7): e201900701, 2019. tab, graf
Article in English | LILACS | ID: biblio-1038120

ABSTRACT

Abstract Purpose: To compare the use of new cyanoacrylate surgical adhesive associated with macroporous tapes in cutaneous synthesis. Methods: Male Wistar rats with a longitudinal incision of 4cm were used on the back, divided into four groups: GI used octyl-cyanoacrylate (Dermabond®), GII used N-2-butylcyanoacrylate, GIII used octyl-cyanoacrylate and macroporous tape and GIV used N-2-butyl cyanoacrylate and macroporous tape. On the fourteenth day, the rats were submitted to euthanasia, were divided in two parts, and a layer of skin subcutaneous tissue through an area of operative healing was removed. One part was submitted to the study of rupture strength with the use of tensiometer, and in the other part histological examination was performed. Results: No force test was similar between groups I and II, being different from groups III and IV (P <0.001), which were identical to each other (P> 0.05). The units were compared among the studied groups, and they were different with the use of macroporous tapes (P> 0.05). Conclusions: The purpose of macroporous tapes is associated with CA adhesives in cutaneous tissues that provide more resistant scars. The use of a combination of macroporous tapes leads to complete re-epithelialization, without provoking foreign body reaction, has hemostatic properties and does not cause an absorptive reaction.


Subject(s)
Animals , Male , Rats , Skin/drug effects , Surgical Wound Dehiscence/prevention & control , Tissue Adhesives/pharmacology , Wound Healing/physiology , Enbucrilate/pharmacology , Suture Techniques , Rats, Wistar
12.
Rev. Col. Bras. Cir ; 46(5): e20192286, 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1057171

ABSTRACT

RESUMO Objetivo: avaliar o perfil de segurança e os resultados estéticos do 2-octilcianoacrilato versus sutura intradérmica com fio de nylon em cirurgias mamárias. Métodos: ensaio clínico randomizado, aberto, que avaliou a ocorrência de complicações, como deiscência, hematoma, infecção e reações alérgicas após o uso do 2-octilcianoacrilato ou do fio de nylon. Também foi analisado o tamanho das incisões, o tempo de fechamento da pele e o tempo cirúrgico total. O resultado estético foi avaliado após 40 e 180 dias da cirurgia, por meio da largura média da ferida operatória e por avaliação subjetiva conceitual (ótimo, bom, razoável ou ruim). Resultados: foram incluídas 79 pacientes, sendo 37 no grupo 2-octilcianoacrilato e 42 no grupo de sutura com fio de nylon. O estudo foi interrompido antes do término do recrutamento dos pacientes pela ocorrência de maior número de deiscências no grupo do adesivo (OR: 11,42; IC95%: 1,36-96,02; p=0,007). Em relação às demais complicações analisadas, ao tempo cirúrgico e ao resultado estético no pós-operatório, não se observaram diferenças significativas entre os grupos. A média do tamanho da ferida operatória foi maior no grupo do adesivo em relação ao grupo da sutura, mas não houve correlação entre o tamanho da ferida e o maior número de deiscências. Conclusão: o 2-octilcianoacrilato apresentou maior risco de deiscência em relação à sutura intradérmica, com resultados estéticos equivalentes.


ABSTRACT Objective: to evaluate the safety profile and aesthetic results of 2-octyl-cyanoacrylate versus intradermal nylon suture in breast surgeries. Methods: an open-label, randomized, clinical trial evaluating the occurrence of complications, such as dehiscence, hematoma, infection, and allergic reactions after the use of 2-octyl-cyanoacrylate or nylon thread. The size of the incisions, skin closure time, and total surgical time were also analyzed. The aesthetic outcome was evaluated at 40 and 180 days after surgery, by means of the average width of the surgical wound and by subjective conceptual assessment (optimal, good, reasonable, or poor). Results: 79 patients were included: 37 in the 2-octyl-cyanoacrylate group and 42 in the nylon suture group. The study was stopped before the end of patient recruitment due to the occurrence of a greater number of dehiscences in the adhesive group (OR: 11.42; 95%CI: 1.36-96.02; p=0.007). Regarding the other analyzed complications, the surgical duration and postoperative aesthetic result, no significant differences were observed between the groups. The mean operative wound size was greater in the adhesive group than in the suture group, but there was no correlation between wound size and the largest number of dehiscences. Conclusion: while the cosmetic outcomes with the two techniques were similar, there was a greater risk of dehiscence with the use of 2-octyl-cyanoacrylate compared to intradermal suturing.


Subject(s)
Humans , Female , Child , Adolescent , Adult , Aged , Aged, 80 and over , Young Adult , Breast Diseases/surgery , Suture Techniques/instrumentation , Cyanoacrylates/therapeutic use , Nylons , Time Factors , Treatment Outcome , Patient Satisfaction , Surgical Wound , Middle Aged
13.
Rev. Ciênc. Méd. Biol. (Impr.) ; 17(2): 164-169, maio -jun. 2018. tab, ilus
Article in Portuguese | LILACS | ID: biblio-1224366

ABSTRACT

Introdução: a face é o centro estético do indivíduo. Por isso, lesões nessa região podem repercutir mais negativamente do que em qualquer outra parte do corpo. Os cianoacrilatos, devido às suas vantagens de uso, incluindo a ausência de marcas de ponto, apresentam-se como um atrativo método de fechamento de feridas faciais em suas mais diversas formas. Objetivo: avaliação da eficácia do fechamento de excisões cutâneas faciais, usando o 2-etilcianoacrilato. Metodologia: estudo retrospectivo, no qual 36 feridas foram ocluídas com 2-etilcianoacrilatocomo alternativa à sutura intradérmica. Resultados: feridas excisionais (100%) foram tratadas com 2-etilcianoacrilato e suturas profundas relaxadoras como método de síntese. Cicatrizes inestéticas (13,9%), deiscência (5,6%) e infecção (2,8%) foram os problemas encontrados. Não houve casos de necrose, reações alérgicas ou de queloide. Os resultados foram considerados satisfatórios na maioria dos pacientes (96,4%). Conclusão: o uso do 2-etilcianoacrilato se mostrou seguro e com excelentes resultados cosméticos no grupo de pacientes selecionados.


Introduction: the face is the aesthetic center of the individual. Therefore, lesions in this region may have more negative repercussions than in any other part of the body. Cyanoacrylates (CA), due to their advantages of use, including the absence of dot marks, present themselves as an attractive method of closing facial wounds in their most diverse forms. Objective: to evaluate the efficacy of the closure of facial skin excisions using 2-ethylcyanoacrylate. Methodology: retrospective study in which 36 wounds were occluded with 2-ethylcyanoacrylate as an alternative to intradermal suture. Results: excisional wounds (100%) were treated with 2-ethylcyanoacrylate and deep relaxation sutures as a synthesis method. Unaesthetic scars (13.9%), dehiscence (5.6%) infection (2.8%) were the problems encountered. There were no cases of necrosis, allergic or keloid reactions. The results were considered satisfactory in most patients (96.4%). Conclusion: the use of 2-ethylcyanoacrylate was safe and with excellent cosmetic results in this group of patients.


Subject(s)
Face
14.
Rev. Bras. Ortop. (Online) ; 53(1): 53-59, Jan.-Feb. 2018. tab, graf
Article in English | LILACS | ID: biblio-899233

ABSTRACT

ABSTRACT Objective: Synthetic adhesives are used by various medical specialties, especially in surgery; however, studies reporting their use in orthopedic practice are scarce. The aim of this study was to compare the results in using ethyl-2-cyanoacrylate or butyl-2-cyanoacrylate in the treatment of fractures in rats. Methods: This was an experimental prospective controlled study in 90 rats, with humerus, femur, and tibia fractures, treated with ethyl-2-cyanoacrylate (SB group; n = 45) or butyl-2-cyanoacrylate (HA group; n = 45). Biomechanical and histomorphometric analyses were performed at three different moments (60, 120, and 180 days); besides a clinical study performed weekly by measurement of the animals body mass. Results: No differences were observed regarding body mass (p = 0.07). In both groups, there were no significant differences regarding maximum load (p = 0.6), yield point strength (p = 0.6), and stiffness coefficient (p = 0.4) of the femurs. The same was observed in tibias for maximum load (p = 0.4), yield point strength (p = 0.7), and stiffness coefficient (p = 0.6). The humerus from both groups had similar bone callus area (p = 0.66). In both groups, there were no statistical differences related to inflammatory cells (p = 0.4), osteoblasts (p = 0.2), and osteoclasts (p = 0.2). Conclusion: Ethyl-2-cyanoacrylate was more effective than butyl-2-cyanoacrylate in the treatment of fractures in rats.


RESUMO Objetivo: Os adesivos sintéticos são usados em várias especialidades médicas cirúrgicas, contudo, os estudos que relatam seu uso na prática ortopédica são escassos. O objetivo deste trabalho foi comparar os resultados do uso do etil-2-cianoacrilato e do butil-2-cianoacrilato no tratamento de fraturas em ratos. Métodos: Foi realizado um estudo experimental, prospectivo e controlado em 90 ratos com fraturas de úmero, fêmur e tíbia, tratados com etil-2-cianoacrilato (grupo SB; n = 45) ou butil-2-cianoacrilato (grupo HA; n = 45). Foram realizadas análises biomecânicas e histomorfométricas em três momentos (60, 120 e 180 dias), além do estudo clínico pela aferição semanal da massa corporal dos animais. Resultados: Não foram observadas diferenças relacionadas à massa corporal dos animais (p = 0,07). Os fêmures de ambos os grupos não apresentaram diferença com relação à carga máxima (p = 0,6), limite de elasticidade (p = 0,6) e coeficiente de rigidez (p = 0,4). Analisando-se as tíbias, o mesmo foi observado com relação à carga máxima (p = 0,4), ao limite de elasticidade (p = 0,7) e ao coeficiente de rigidez (p = 0,6). Os úmeros de ambos os grupos apresentaram a mesma área de calo ósseo formado (p = 0,66). Em ambos os grupos, não houve diferença estatística relacionada ao número de osteoblastos (p = 0,2), osteoclastos (p = 0,2) e células inflamatórias (p = 0,4). Conclusão: O etil-2-cianoacrilato foi mais eficaz do que o butil-2-cianoacrilato no tratamento de fraturas em ratos.


Subject(s)
Animals , Rats , Tissue Adhesives , Fracture Healing , Cyanoacrylates , Fractures, Bone
15.
Article in English | WPRIM | ID: wpr-739176

ABSTRACT

Transcatheter arterial embolization using N-butyl-2-cyanoacrylate (NBCA) for gastrointestinal arterial bleeding enables higher cessation rate and lower recurrent bleeding rate compared with conventional embolic materials including gelatin sponge, metallic coil, and polyvinyl alcohol (PVA) particle. Glue embolization is particularly effective in patients with coagulopathy. Even in the lower gastrointestinal tract, ischemic bowel complications by glue embolization are comparable to other agents. Glue embolization is also effective for arterial esophageal bleeding without any serious ischemic complications although the anatomy of the esophageal artery is complex and varied. For bleeding after abdominal surgery such as pancreaticoduodenectomy or hepatic lobectomy, interventional radiologists should be careful with indicating glue embolization because the presence of fewer collateral vessels can easily result in serious ischemic complications. Modified glue such as Glubran 2 (NBCA associated with methacryloxyfulfolane) can reduce the risk of ischemic complication due to its less thermal reaction, but the outcomes seem unsatisfactory.


Subject(s)
Humans , Adhesives , Arteries , Cyanoacrylates , Embolization, Therapeutic , Enbucrilate , Gastrointestinal Hemorrhage , Gelatin , Hemorrhage , Lower Gastrointestinal Tract , Pancreaticoduodenectomy , Polyvinyl Alcohol , Porifera
16.
Journal of Medical Postgraduates ; (12): 109-112, 2018.
Article in Chinese | WPRIM | ID: wpr-700784

ABSTRACT

Hemostatic agents play a crucial role in successful operations and the pre-hospital care of war wounds. Recently, hemostatic agents have become a hot topic in medicine,surgery and emergency medicine. The topical absorbable hemostatic agents are now the first choice of some clinical bleeding and war wounds owing to their features, such as flexible operation, high efficiency and wide application. A great variety of topical absorbable hemostatics have flooded the market. There are many differences existing among these hemostatics,including sources of material and the hemostatic mechanism,which makes it hard for clinicians to professionally se-lect the appropriate one.This review discusses the classification,hemostatic mechanism,clinical application,advantages and disadvan-tages of common topical absorbable hemostatics. Furthermore,we provide the basic theory for surgeons to choose suitable hemostatic a-gents at the right time.

17.
Article in Korean | WPRIM | ID: wpr-715640

ABSTRACT

Ectopic varices are rare among patients with portal hypertension, especially in the ascending colon. It is difficult to evaluate massive lower gastrointestinal bleeding in patients with liver cirrhosis by colonoscopy due to hemodynamic instability and poor bowel preparation. In Korea, there has only been one case report about ascending colon variceal bleeding, in which hemostasis was performed by venous coil embolization. We report another rare case of ascending colon variceal bleeding in a patient with alcoholic cirrhosis, who was successfully treated via two sessions of N-butyl-2-cyanoacrylate injection through colonoscopy. This case suggests that the careful endoscopic approach and hemostasis with glue injection might be an option for treating massive bleeding in the lower gastrointestinal varix.


Subject(s)
Humans , Adhesives , Colon, Ascending , Colonoscopy , Cyanoacrylates , Embolization, Therapeutic , Enbucrilate , Esophageal and Gastric Varices , Hemodynamics , Hemorrhage , Hemostasis , Hypertension, Portal , Korea , Liver Cirrhosis , Liver Cirrhosis, Alcoholic , Varicose Veins
18.
Gut and Liver ; : 562-570, 2018.
Article in English | WPRIM | ID: wpr-716829

ABSTRACT

BACKGROUND/AIMS: Gastroesophageal variceal hemorrhage is a common complication of portal hypertension. Endoscopic therapy is currently recommended for preventing gastroesophageal variceal rebleed. However, the rate of variceal rebleed and its associated mortality remain concerning. This study is aimed at differentiating patient response to endoscopic therapy based on endoscopic ultrasound (EUS) findings. METHODS: One-hundred seventy patients previously treated with repeat endoscopic therapy for secondary prophylaxis were enrolled and classified into two groups based on treatment response. Prior to consolidation therapy, all patients received an EUS examination to observe for extraluminal phenomena. All available follow-up endoscopic examination records were retrieved to validate study results. RESULTS: Of the 170 subjects, 106 were poor responders, while 64 were good responders. The presence of para-gastric, gastric perforating, and esophageal perforating veins was associated with poor patient response (p < 0.001). The odds ratio for para-gastric veins was 5.374. Follow-up endoscopic findings for poor responders with incomplete variceal obliteration was closely correlated with the presence of para-gastric veins (p=0.002). CONCLUSIONS: The presence of para-gastric veins is a characteristic of poor response to endoscopic therapy for treating gastroesophageal varices. Early identification of this subgroup necessitates a change in course of treatment to improve overall patient outcome.


Subject(s)
Humans , Cyanoacrylates , Endosonography , Esophageal and Gastric Varices , Follow-Up Studies , Hemorrhage , Hypertension, Portal , Mortality , Odds Ratio , Risk Assessment , Ultrasonography , Varicose Veins , Veins
19.
São Paulo; s.n; 2018. 104 p
Thesis in Portuguese | LILACS, BDENF | ID: biblio-1395806

ABSTRACT

Introdução: O trauma perineal provocado pelo parto vaginal e seu reparo são importantes preocupações relacionadas ao períneo. A técnica ideal de reparo deve ser rápida, indolor, de fácil execução e que reduza a dor no puerpério. As evidências científicas apontam que a técnica e o material mais adequados para o reparo do trauma perineal são a sutura contínua e o fio poliglactina 910 de rápida absorção. Entretanto, em lacerações de primeiro e segundo graus, apesar de promover boa cicatrização, a sutura está relacionada à dor no períneo. A cola adesiva cirúrgica é um material utilizado em diversas cirurgias e especialidades médicas, com alto grau de resistência e facilidade no procedimento cirúrgico, o que parece se apresentar como uma alternativa eficaz no reparo perineal. Objetivo: Determinar a viabilidade de um ensaio clínico controlado e aleatorizado (ECA) sobre o uso da cola adesiva cirúrgica no reparo de lacerações perineais de primeiro grau durante o parto normal. Método: Estudo piloto paralelo, controlado e aleatorizado comparando a cola adesiva cirúrgica Epiglu® (etil-2-cianoacrilato) com o fio Vicryl Rapide® (poliglactina 910) no reparo perineal, realizado no Pronto Socorro e Maternidade Municipal Zoraide Eva das Dores, Itapecerica da Serra-SP. A amostra foi constituída por 20 mulheres com lacerações perineais de primeiro grau com necessidade de reparo durante o parto normal, distribuídas no grupo experimental (GE; n=10; submetidas ao reparo com Epiglu®) e grupo controle (GC; n=10; submetidas ao reparo com sutura com Vicryl Rapide®). O desfecho primário foi a ocorrência e intensidade da dor perineal após o parto e os desfechos secundários foram o processo de cicatrização, a satisfação da mulher com reparo perineal e o tempo dispendido pelo profissional para o reparo. Os desfechos foram avaliados pela Escala Visual Numérica de 11 pontos para intensidade da dor perineal; Escala REEDA, para cicatrização perineal; Escala Visual Analógica para satisfação da mulher; cronômetro digital para contagem do tempo de reparo dispendido em ambas as técnicas. Os dados foram coletados em quatro etapas: até 2 horas pós-parto, 12-24 horas, 36-48 horas e 10-20 dias pós-parto. Resultados: A média da intensidade da dor perineal foi significativamente menor entre as mulheres no GE, em todas as etapas do estudo (variação de 2,0-0,2 e 2,5-0,6 nos GE e GC, respectivamente). A cicatrização perineal apresentou escores significativamente melhores na escala REEDA entre as mulheres no GE, em todas as etapas (variação de 0,6-0,0 e 1,8-0,7, nos GE e GC, respectivamente). A satisfação das mulheres com reparo perineal foi significativamente superior no GE (100% estavam satisfeitas ou muito satisfeitas), em comparação com o GC (10% a 20% estavam insatisfeitas ou muito insatisfeitas). A média de tempo gasto para o reparo perineal foi 5 minutos no GE e 21 minutos no GC (p<0,001). Conclusão: O estudo mostrou que é viável adotar a técnica de reparo com Epiglu® utilizada no estudo piloto, bem como os mesmos desfechos e períodos de seguimento pós-parto. Além disso, os resultados foram importantes para comparar os métodos de reparo perineal e calcular o tamanho da amostra para o ECA. Protocolo: O estudo foi registrado no Portal de Registro Brasileiro de Ensaios Clínicos http://www.ensaiosclinicos.gov.br/rg/RBR-2h84gt/.


Introduction: One of the important concerns regarding the perineum is the trauma caused by the vaginal delivery and perinealrepair. The ideal perineal repair technique should be quick, painless, easy to perform in order to decrease pain in the puerperium. The scientific evidence indicates that the most suitable technique and material for the repair of perineal trauma are continuous suture and the polyglactin 910 rapid absorption thread. However, in the first and second degrees lacerations, despite promoting good healing, the suture is associated with perineum pain. The surgical adhesive is a tool used in several surgeries and medical specialties, had high resistance and is ease to manage during the surgical procedure, which seems to be an effective alternative for perineal repair. Objective: To determine the feasibility of a clinical randomized controlled trial (RCT) on the use of surgical adhesive in the repair of first-degree perineal trauma during vaginal delivery. Methods: Parallel, controlled and randomized pilot study comparing the outcomes of the use of surgical adhesive glue Epiglu (ethyl-2-cyanoacrylate) and Vicryl Rapide (polyglactin 910) thread in perineal repair. The research was performed at Pronto Socorro e Maternidade Zoraide Eva das Dores, Itapecerica da Serra-SP, Brazil. The sample comprised 20 women with first-degree perineal trauma that need repair during normal delivery, distributed in experimental group (EG, n=10, undergoing repair with Epiglu) and control group (CG;n=10, undergoing repair with Vicryl Rapide). The primary outcome was the occurrence and intensity of perineal pain after delivery and secondary outcomes were healing process, the womans satisfaction on perineal repair and the time spent by the professional to repair the trauma. The outcomes were evaluated by the 11-point Visual Numeric Scale for perineal pain intensity; REEDA Scale for perineal healing; Visual Analogue Scale for womens satisfaction; digital stopwatch for counting the repair time in both suture techniques. Data were collected in four stages: up to 2 hours after delivery, 12-24 hours, 36-48 hours and 10-20 days postpartum. Results: In all study stages, the average of the intensity of perineal pain among women in EG was significantly lower than CG (variation of 2.0-0.2 in EG and 2.5-0.6 in CG). In all stages, perineal healing showed significantly better REEDA scale scores among women in EG, (variation of 0.6-0.0 in EG and 1.8-0.7 in CG). The womens satisfaction with perineal repair was significantly higher in EG (100% were satisfied or very satisfied), compared with CG (10% to 20% were unsatisfied or very unsatisfied). The average time for perineal repair was 5 minutes in EG and 21 minutes in CG (p<0.001). Conclusion: The results of the study were important to compare perineal repair methods and calculate the sample size for the future RCT. In addition, we showed that is possible to adopt the perineal repair technique with Epiglu developed in the pilot study, as well as the same outcomes and postpartum follow-up periods. Protocol: The study was registered in the Brazilian Clinical Trials Registry http://www.ensaiosclinicos.gov.br/rg/RBR-2h84gt/.


Subject(s)
Perineum , Obstetric Nursing , Parturition
20.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;32(6): 487-491, Nov.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-897961

ABSTRACT

Abstract Introduction: Tissue adhesives can be used as adjacent to sutures to drop or avoid bleeding in cardiovascular operations. Objective: To verify the efficiency of fibrin and cyanoacrylate adhesive to seal arterial sutures and if the adhesives penetrate through suture line to the inner of arteries. Methods: 20 abdominal aorta segments of pigs were divided into two groups according to the adhesive which would be used as adjacent to the suture. In every arterial segment an arteriotomy was done, followed by a conventional artery closure. Afterwards a colloidal fluid was injected inside the arterial segment with a simultaneous intravascular pressure monitoring up to a fluid leakage through the suture. This procedure was repeated after application of one of the adhesives on the suture in order to check if the bursting pressure increases. The inner aorta segments also were analyzed in order to check if there was intraluminal adhesive penetration. Results: In Suture 1 group, the mean arterial pressure sustained by the arterial suture reached 86±5.35 mmHg and after the fibrin adhesive application reached 104±11.96 (P<0.002). In the Suture 2 group, the mean arterial pressure sustained by the suture reached 83±2.67 mmHg and after the cyanoacrylate adhesive application reached 152±14.58 mmHg (P<0.002). Intraluminal adhesive penetration has not been noticed. Conclusion: There was a significant rise in the bursting pressure when tissue adhesives were used as adjacent to arterial suture, and this rise was higher if the cyanoacrylate adhesive was used. In addition, the adhesives do not penetrate through the suture line into the arteries.


Subject(s)
Animals , Tissue Adhesives , Fibrin , Fibrin Tissue Adhesive , Suture Techniques , Cyanoacrylates , Swine , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL