ABSTRACT
@#The high incidence and untreated rate of root caries, a common and frequently occurring oral disease with challenging treatment in elderly individuals, is the main cause of tooth loss among elderly people, as rapid development results in pulpitis and periapical periodontitis or residual crown and root, which has been regarded as one of the common chronic oral diseases seriously affecting the quality of life of elderly people. Thus, early intervention and prevention are important. Traditional dental materials for preventing root caries have been widely used in clinical practice; however, they have the disadvantages of tooth coloring, remineralization and low sterilization efficiency. A series of new dental materials for preventing root caries have gradually become a research hotspot recently, which have the advantages of promoting the mineralization of deep dental tissue, prolonging the action time and enhancing adhesion. Future caries prevention materials should be designed according to the characteristics of root surface caries and the application population and should be developed toward simplicity, high efficiency and low toxicity. This review describes current research regarding anti-caries prevention material application, serving as a theoretical underpinning for the research of root caries prevention materials, which is important for both promotion in the effective prevention of root caries and improvement in the status of oral health and the quality of life among old people.
ABSTRACT
Abstract Acidic pH can modify the properties of repair cements. In this study, volumetric change and solubility of the ready-to-use bioceramic repair cement Bio-C Repair (BCR, Angelus, Londrina, PR, Brazil) were evaluated after immersion in phosphate-buffered saline (PBS) (pH 7.0) or butyric acid (pH 4.5). Solubility was determined by the difference in initial and final mass using polyethylene tubes measuring 4 mm high and 6.70 mm in internal diameter that were filled with BCR and immersed in 7.5 mL of PBS or butyric acid for 7 days. The volumetric change was established by using bovine dentin tubes measuring 4 mm long with an internal diameter of 1.5 mm. The dentin tubes were filled with BCR at 37°C for 24 hours. Scanning was performed with micro-computed tomography (micro-CT; SkyScan 1176, Bruker, Kontich, Belgium) with a voxel size of 8.74 µm. Then, the specimens were immersed in 1.5 mL of PBS or butyric acid at and 37 °C for 7 days. After this period, a new micro-CT scan was performed. Bio-C Repair showed greater mass loss after immersion in butyric acid when compared with immersion in PBS (p<0.05). Bio-C Repair showed volumetric loss after immersion in butyric acid and increase in volume after immersion in PBS (p<0.05). The acidic pH influenced the solubility and dimensional stability of the Bio-C Repair bioceramic cement, promoting a higher percentage of solubility and decrease in volumetric values.
ABSTRACT
Abstract The aim of this study was to identify and analyze the characteristics of the 100 most cited articles about dental sealants (DS) in dentistry. In September 2023, a search was performed in the Web of Science Core Collection (WoS-CC) database. The following information was extracted from each article: number and density of citations, year of publication, authorship, journal, impact factor, keywords, study design, theme, continent, country, and institution. The citations of the WoS-CC were compared with those of the Scopus and Google Scholar databases. The VOSviewer software was used to generate collaborative networks. The number of citations ranged from 33 to 205. The articles were published between 1961 and 2016. Buonocore MG (7%) was the most prominent author among the most cited. The Journal of the American Dental Association was the most frequent journal (25%) and Journal of Dental Research (7.6) had the highest impact factor. Most studies had interventional (41%) and laboratory (31%) designs, mainly addressing DS effectiveness in the prevention and control of dental caries (86%). There was a predominance of publications from North America (46%) and the USA was the country with the highest number of articles (44%). The most frequent institutions were the Centers for Disease Control and Prevention (USA) and the University of Rochester (USA) (6% each). "Retention" was the most frequent keyword. In conclusion, the 100 most cited articles were mostly interventional and laboratory studies, addressing the retention and efficacy of DS. Most of the articles were concentrated in North America and Europe, demonstrating a little collaboration from other continents.
ABSTRACT
ABSTRACT Objective: To guide professionals about the criteria for replacing amalgam restorations and inform them about the new guidelines regarding the use/indication of this (amalgam) material after the Minamata Convention - COP-4. Material and Methods: The articles were selected from the databases (PubMed, Scielo, Bireme), and relevant articles on the subject between the years 2003-2021 were selected. Recently, social media have been flooded with dental treatments that aim to perform restorations only with composite resins or other types of esthetic material and completely replace all dental amalgam restorations, irrespective of their time in place, size, and functionality. Results: Although improperly, it has been noted that this information reaches patients, and they are led to believe in the inaccurate data that is passed on, such as, for example, (that amalgam leads to) permanent contamination by mercury, causing systemic problems and the loss of the tooth. Conclusion: The "phase down" of amalgam in research and teaching has previously been observed in several countries worldwide; however, its use is still necessary given particular circumstances, which, theoretically, make it a material with exact indication.
Subject(s)
Dental Amalgam/chemistry , Dental Materials , Dental Restoration, Permanent , Long Term Adverse Effects , Longitudinal Studies , Composite ResinsABSTRACT
Abstract This study aimed to evaluate the masking ability of different resin composite (RC) layering techniques over discolored substrates. Layering strategies were tested (n=10), using different RCs: flowable opaque, white dentin, A1 dentin, A1 body, and A1 enamel (Filtek Z350XT; 3M ESPE). Bilayer and trilayer RC combinations resulted in final thicknesses of 1 mm, 1.5 mm, and 2 mm. Substrates tested were: A1 (reference), A3, A4, B3, C2, and C4 (Filtek Z350XT Dentin; 3M ESPE). Color differences (∆E00) were measured for the RC layers over discolored substrates with the CIEDE2000 formula. The results were compared statistically (One-way ANOVA) and descriptively (acceptability=1.77 and perceptibility=0.81 thresholds). The layering strategy influenced the ∆E00 of RCs over all substrates (P<0.001). The 1 mm bilayer group combining 0.5 mm of dentin and 0.5 mm of enamel led to ∆E00 below AT for substrates A3 and B3; the 1.5 mm bilayer group combining A1 dentin (1 mm) and enamel (0.5 mm) provided ∆E00 below AT for substrates A3, A4, and C2 and ∆E00 below PT for B3; for substrate C4, the 2 mm trilayer group combining flowable opaque (0.2 mm), A1 dentin (1.3 mm) and enamel (0.5 mm) provided ∆E00 below PT, and the 1.5 mm trilayer groups (flowable opaque + 0.8 mm dentin or body + enamel) led to ∆E00 below AT. Resin Composites were effective in masking discolored substrates. The most adequate layering strategy depended on substrate shade.
Resumo O objetivo deste estudo foi avaliar a capacidade de mascaramento de diferentes técnicas de estratificação de resina composta (RC) sobre substratos descoloridos. Estratégias de estratificação foram testadas (n=10), utilizando diferentes RCs: opaco fluido, dentina branca, dentina A1, corpo A1 e esmalte A1 (Filtek Z350XT; 3M ESPE). As combinações RC bicamada e tricamada resultaram em espessuras finais de 1 mm, 1,5 mm e 2 mm. Os substratos testados foram: A1 (referência), A3, A4, B3, C2 e C4 (Filtek Z350XT Dentina; 3M ESPE). As diferenças de cor (∆E00) foram medidas para as camadas RC sobre substratos descoloridos com a fórmula CIEDE2000. Os resultados foram comparados estatisticamente (ANOVA de 1 fator) e descritivamente (aceitabilidade=1,77 e perceptibilidade=0,81 limiares). A estratégia de estratificação influenciou o ∆E00 dos RCs em todos os substratos (P<0,001). O grupo de bicamada de 1 mm combinando 0,5 mm de dentina e 0,5 mm de esmalte levou a um ∆E00 abaixo de AT para os substratos A3 e B3; o grupo de bicamada de 1,5 mm combinando dentina A1 (1 mm) e esmalte (0,5 mm) forneceu um ∆E00 abaixo de AT para substratos A3, A4 e C2 e ∆E00 abaixo de PT para B3; para o substrato C4, o grupo tricamada de 2 mm combinando opaco fluido (0,2 mm), dentina A1 (1,3 mm) e esmalte (0,5 mm) forneceu um ∆E00 abaixo de PT, e os grupos tricamada de 1,5 mm (opaco fluido + dentina 0,8 mm ou corpo + esmalte) levou a um ∆E00 abaixo de AT. As resinas compostas foram eficazes para mascarar substratos descoloridos. A estratégia de estratificação mais adequada dependeu da tonalidade do substrato.
ABSTRACT
Abstract The aim of this study was to develop a mixture of dimethacrylate isomers (PG6EMA) as a potential monomer for dental adhesives and composites. PG6EMA was synthesized de novo and characterized in the presence of ethanol (3%, 6% or 9%). BisGMA/TEGDMA (BTEG, 50/50 wt.%) was used as the resin control. Composites were formulated with 60 wt.% of either PG6EMA or BisGMA (40 wt.% TEGDMA and 70 wt.% filler). DMPA (0.2 wt.%) and DPI-PF6 (0.4 wt.%) were added as photoinitiators, irradiated with a mercury arc lamp (320-500 nm, 500 mW/cm2; Acticure). All materials were tested for polymerization kinetics (near-infrared), viscosity (η) and storage modulus (G', oscillatory rheometry). The composites were further characterized for water sorption/solubility, wet/dry flexural strength/modulus and polymerization stress. Data were analyzed with one-way ANOVA/Tukey's test (α = 0.05). The PG6EMA resins showed lower rates of polymerization compared with BTEG (p = 0.001) but high degrees of conversion (p = 0.002). Solvent concentration did not affect RPMAX but the 6% and 9% mixtures showed higher final DC, likely due to reduced viscosity. PG6EMA had much higher viscosity than BTEG (p <0.001) and lower G' (p = 0.003). Composites modified with PG6EMA have slower polymerization rates (p = 0.001) but higher final DC (p = 0.04) than the control. PG6EMA/TEGDMA showed lower dry/wet flexural strength and comparable dry modulus. The PG6EMA/TEGDMA composite showed a 18.4% polymerization stress reduction compared to the BTEG composite. Both base monomers had similar WS/SL and G'. Within its limitations, this study demonstrated that the newly synthesized PG6EMA was a viable alternative to BisGMA in dental composites.
ABSTRACT
Abstract Objective this study sought to evaluate the effect of isobornyl methacrylate (IBOMA) as a diluent monomer on the physicochemical properties of experimental flowable resin composites. Methodology the organic resin matrix of a modal flowable resin composite was formulated with 50 wt.% of bisphenol-A-glycidyl methacrylate (Bis-GMA) and 50 wt.% of a diluent monomer, in which IBOMA was used as a combining or substituent diluent monomer to triethylene glycol dimethacrylate (TEGDMA). The resin matrices were filled with 55 wt.% particles, of which 10 wt.% was 0.05-μm fumed silica, and 45 wt.% was 0.7-μm BaBSiO2 glass. Polymerization shrinkage stress (PSS; n=10), degree of conversion (DC; n=3), maximum rate of polymerization (Rpmax; n=3), film thickness (FT; n=10), sorption (Wsp; n=10), solubility (Wsl; n=10), flexural strength (FS; n=10), flexural modulus (FM; n=10), Knoop microhardness (KH; n=10), and microhardness reduction after chemical softening (HR; n=10) were evaluated. Data were analyzed using one-way ANOVA, followed by Tukey's test (α=0.05; β=0.2). Results the results showed that the substitution or addition of IBOMA reduced FT (p=0.001), PSS (p=0.013), Rpmax (p=0.001), DC (p=0.001), FM (p=0.006) Wsp (p=0.032), and Wsl (p=0.021). However, when used as a complete substituent, IBOMA demonstrated significantly lower FS (p=0.017) and KH (p=0.008), while TEGDMA demonstrated significantly lower HR (p=0.022). Conclusion the flowable composite containing IBOMA combined with TEGDMA showed no effect in KH and FS and effectively reduced the PSS, RP, FT, Wsp, and Wsl. However, it showed a reduction in DC, FS, and an increase in HR.
ABSTRACT
Abstract This study assessed the physicochemical and antibiofilm properties of white mineral trioxide aggregate (MTA) associated with 1 or 2% of farnesol. Setting time was evaluated based on ISO 6876/2012. Radiopacity was evaluated by radiographic analysis. pH was assessed after time intervals of 1, 3, 7, 14, 21, and 28 days. Solubility (% mass loss) and volumetric change (by micro-CT) of the cements were evaluated after immersion in distilled water. The presence of voids inside the materials was assessed by using micro-CT. Antibiofilm activity against Enterococcus faecalis was evaluated by crystal violet assay and the modified direct contact test performed with biofilm previously formed on bovine root dentin for 14 days. Data were submitted to ANOVA/Tukey tests with 5% significance level. The incorporation of farnesol into MTA increased its setting time, but decreased its solubility at 30 days and its volumetric loss in all periods (p < 0.05). Radiopacity and solubility after 7 days were similar among the materials (p > 0.05). The association of farnesol showed the highest pH value after 1 and 3 days (p < 0.05). The association of farnesol with MTA promoted a decrease in the presence of voids, and increased the antimicrobial activity on biofilm biomass of E. faecalis (p < 0.05). In conclusion, the addition of farnesol can be suggested to improve the antimicrobial properties and the consistency of MTA.
ABSTRACT
Objective: This study aimed to investigate of bioactive materials with specific properties, particularly highly plastic bioceramic cements. These materials are being studied extensively due to their potential to maintain pulp vitality and promote tissue regeneration. Material and Methods: Tooth discoloration induced by an experimental tricalcium silicate-based cement (EC) was evaluated and compared with that of Biodentine (BD) and white MTA-Angelus (MTA). Cavities were prepared on the lingual surfaces of thirty-two blocks of healthy bovine incisors. The blocks were chemically cleaned and then subjected to an initial color evaluation (CIELab values) using a spectrophotometer and randomly divided into three experimental groups (n=10); two additional blocks served as controls. After manipulation, the cements were placed in the cavities, which were subsequently restored with composite restorations. After another color measurement (baseline), they were immersed in bottles of distilled water; they were stored at 37 °C and 100% humidity for the entire test period. The color change (ΔE) was measured after 14, 30, 120 and 150 days. ANOVA and Tukey tests showed significant differences after 14 days (EC vs. MTA), 30 days (EC vs. BD) and 120/150 days (EC vs. BD/MTA) (p < 0.05). Results: All tested materials induced ΔE changes, with the EC group showing the least change at the end of the experiment (ΔE=4.08). Conclusion: EC induced less color change over a 5-month period and thus showed color stability over the entire period, whereas BD and MTA showed progressive discoloration. (AU)
Objetivo: O objetivo deste estudo foi investigar materiais bioativos com propriedades específicas, particularmente cimentos biocerâmicos altamente plásticos. Esses materiais estão sendo amplamente estudados devido ao seu potencial para manter a vitalidade da polpa e promover a regeneração dos tecidos. Material e Métodos: A descoloração dentária induzida por um cimento experimental à base de silicato tricálcico (CE) foi avaliada e comparada com a do Biodentine (BD) e do MTA-Angelus branco (MTA). Foram preparadas cavidades nas superfícies linguais de trinta e dois blocos de incisivos bovinos saudáveis. Os blocos foram quimicamente limpos e, em seguida, submetidos a uma avaliação inicial de cor (valores CIELab) usando um espectrofotômetro e divididos aleatoriamente em três grupos experimentais (n=10); dois blocos adicionais serviram como controles. Após a manipulação, os cimentos foram colocados nas cavidades, que foram posteriormente restauradas com compósito. Após outra medição de cor (valor de referência), eles foram imersos em frascos de água destilada; oram armazenados a 37 °C e 100% de umidade durante todo o período de teste. A alteração de cor (ΔE) foi medida após 14, 30, 120 e 150 dias. Os testes ANOVA e Tukey mostraram diferenças significativas após 14 dias (CE vs. MTA), 30 dias (CE vs. BD) e 120/150 dias (CE vs. BD/MTA) (p < 0,05). Resultados: Todos os materiais testados induziram alterações de ΔE, sendo que o grupo EC apresentou a menor alteração no final do experimento (ΔE=4,08). Conclusão: O EC induziu menos alterações de cor em um período de 5 meses e, portanto, apresentou estabilidade de cor durante todo o período, enquanto o BD e o MTA apresentaram descoloração progressiva.(AU)
Subject(s)
Silicate Cement , Tooth Discoloration , Biomedical and Dental Materials , Dental Cements , EndodonticsABSTRACT
Abstract The aim of this study was to evaluate the influence of adding quaternary ammonium methacrylates (QAMs) to experimental adhesives by assessing the degree of conversion (DC), cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. Two QAMs were added to an experimental adhesive: dimethylaminododecyl methacrylate bromododecane (DMADDM) or dimethylaminododecyl methacrylate bromohexadecane (DMAHDM) at three concentrations each: 1, 2.5, and 5 wt.%. Experimental adhesive without QAMs (control group) and commercially available Transbond XT Primer (3M Unitek, Monrovia, California, USA) were used for comparisons. The adhesives were tested for DC, cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. DC, cytotoxicity against fibroblasts, and antibacterial activity were analyzed using one-way ANOVA and Tukey's multiple comparisons. Cytotoxicity against keratinocytes was evaluated using the Kruskal Wallis and Dunn's post-hoc (α = 5%) tests. Transbond showed lower DC as compared to 5% DMAHDM, 1% DMADDM, and 5% DMADDM (p < 0.05). However, all groups presented proper DC when compared to commercial adhesives in the literature. In the evaluation of cytotoxicity against keratinocytes, Transbond induced higher viability than 2.5 wt.% groups (p < 0.05). Against fibroblasts, Transbond induced higher viability as compared to 5 wt.% groups (p < 0.05). DMAHDM at 5 wt.% reduced biofilm formation when compared to all the other groups (p < 0.05). Despite their cytotoxic effect against keratinocytes, gingival fibroblasts showed higher viability. DMAHDM at 5 wt.% decreased Streptococcus mutans viability. The incorporation of DMAHDM at 5 wt.% may be a strategy for reducing the development of white spot lesions.
ABSTRACT
Abstract This study investigated microshear bond strength (µSBS) of two (2) dual-cured resin-luting agents (RelyX™ Ultimate and RelyX™ U200) when photoactivated through varying thicknesses of lithium disilicate, with or without thermal cycling. Discs of IPS e.max Press of 0.5, 1.5, and 2 mm in thickness were obtained. Elastomer molds (3.0 mm in thickness) with four cylinder-shaped orifices 1.0 mm in diameter, were placed onto the ceramic surfaces and filled with resin-luting agents. A Mylar strip, glass plate, and load of 250 grams were placed over the filled mold. The load was removed and the resin-luting agents were photoactivated through the ceramics using a single-peak LED (Radii Plus.) All samples were stored in distilled water at 37oC for 24 h. Half of the samples were subjected to thermal cycling (3,000 cycles; 5ºC and 55ºC). All samples were then submitted to µSBS test using a universal testing machine (Instron 4411) at a crosshead speed of 0.5 mm/min. Data were submitted to three-way ANOVA and Tukey post-hoc test (α=0.05). The mean µSBS at 24 h was significantly higher than after thermal cycling (p<0.05). No statistical difference was found between resin-luting agents (p > 0.05). The mean µSBS for groups photoactivated through 0.5 mm ceramic were significantly higher than 1.5 mm and 2.0 mm (p < 0.05). In conclusion, increased ceramic thicknesses reduced the bond strength of tested resin-luting agents to lithium disilicate. No differences were found between resin-luting agents. Thermal cycling reduced the bond strength of both resin-luting agents.
Resumo: Este estudo investigou a resistência de união ao microcisalhamento (RUµC) de dois (2) agentes de cimentação de resina dual (RelyX™ Ultimate e RelyX™ U200) quando fotoativados através de diferentes espessuras de dissilicato de lítio, com ou sem ciclagem térmica. Discos do IPS e.max Press de 0,5, 1,5 e 2 mm de espessura foram obtidos. Moldes de elastômero (3,0 mm de espessura) com quatro orifícios cilíndricos de 1,0 mm de diâmetro foram colocados sobre as superfícies cerâmicas e preenchidos com agentes de cimentação de resina. Uma tira Mylar, placa de vidro e carga de 250 gramas foram colocadas sobre o molde preenchido. A carga foi removida e os agentes de cimentação resinosos foram fotoativados através da cerâmica usando um LED de pico-único (Radii Plus). Todas as amostras foram armazenadas em água deionizada a 37oC por 24 h. Metade das amostras foi submetida a ciclagem térmica (3.000 ciclos; 5ºC e 55ºC). Todas as amostras foram então submetidas ao teste de RUµC usando uma máquina de teste universal (Instron 4411) com velocidade de 0,5 mm/min. Os dados foram submetidos à Análise de Variância três fatores e ao teste post-hoc de Tukey (α = 0,05). A média de RUµC em 24 h foi significativamente maior do que após a ciclagem térmica (p < 0,05). Não houve diferença estatística entre os cimentos resinosos (p > 0,05). As médias de RUµC para grupos fotoativados através de cerâmica de 0,5 mm foram significativamente maiores do que 1,5 mm e 2,0 mm (p < 0,05). Em conclusão, o aumento da espessura da cerâmica reduziu a resistência de união dos agentes de cimentação resinosos ao dissilicato de lítio. Não foram encontradas diferenças entre os agentes de cimentação resinosos. A ciclagem térmica reduziu a resistência de união de ambos os agentes de cimentação resinosos.
ABSTRACT
Objective: This systematic review aims to compare the clinical longevity of metallic and fiberglass intraradicular posts in teeth with severely compromised crowns, utilizing randomized clinical trials and case reports published in the last eleven years. Material and Methods: The research was conducted on PubMed, Medline, Lilacs, and BBO databases using the first search strategy with the descriptors 'dental posts,' 'longevity,' 'fiberglass-reinforced posts' or 'metallic posts.' The second search strategy involved analyzing the references of articles identified by the first search. Both studies were carried out with stringent inclusion and exclusion criteria. Results: No statistically significant and clinically relevant differences in longevity were observed between metallic and fiberglass posts. Conclusion: The clinical success and durability of the restorative procedure using intraradicular posts primarily depend on the remaining amount around the post (ferrule), the type and position of the tooth in the arch (impacting the masticatory forces exerted on the restored tooth), and the correct application of the cementation technique. It is noteworthy that fiberglass posts offer substantial advantages by presenting a modulus of elasticity similar to dental structure, ensuring a more homogeneous distribution of masticatory forces and reducing the risk of fractures. These findings have practical implications for material selection in restorative procedures involving intraradicular posts.(AU)
Objetivo: Esta revisão sistemática visa comparar a longevidade clínica de pinos intrarradiculares metálicos e de fibra de vidro em dentes com coroas severamente comprometidas, através de estudos clínicos randomizados e relatos de casos, publicados nos últimos onze anos. Material e Métodos: A pesquisa foi conduzida nas bases de dados PubMed, Medline, Lilacs e BBO, utilizando a primeira estratégia de busca com os s 'pinos dentais' e 'longevidade' e 'pinos reforçados com fibra de vidro' ou 'pinos metálicos'. A segunda estratégia de busca consistiu na análise das referências dos artigos identificados pela primeira estratégia. Ambos os estudos foram delineados com critérios rigorosos de inclusão e exclusão. Resultados: Não se constataram diferenças estatisticamente significativas e clinicamente relevantes na longevidade entre pinos metálicos e de fibra de vidro. Conclusão: O êxito clínico e a durabilidade do procedimento restaurador empregando pinos intrarradiculares dependem primordialmente da quantidade de remanescente ao redor do pino (férula), do tipo e posição do dente na arcada (o que impacta nas forças mastigatórias exercidas sobre o dente restaurado) e da aplicação correta da técnica de cimentação.Destaca-se que o pino de fibra de vidro oferece vantagens substanciais ao apresentar módulo de elasticidade similar à estrutura dentária, assegurando uma distribuição mais homogênea das forças mastigatórias e reduzindo o risco de fraturas (AU)
Subject(s)
Dental Materials , Dental PinsABSTRACT
Abstract This study was aimed at analyzing the surface properties of a universal resin composite and evaluating the effect of preheating on its physicochemical properties. Two commercial resin composites were used under two conditions: Filtek Universal Restorative (UR); UR preheated (URH); Filtek Supreme (FS) and FS preheated (FSH). The film thickness (FT) test (n = 10) was done using two glass slabs under compression. Flexural strength (FLS) and modulus (FLM) were evaluated using a three-point flexion test (n = 10). Polymerization shrinkage stress (PSS) was evaluated in a universal testing machine (n = 5). Gap width (GW) between composite and mold was measured in internally polished metallic molds (n = 10). The degree of conversion (DC) was evaluated by Fourier Transform Infrared spectroscopy (n = 3). The morphology of the filler particles was checked by scanning electron microscope (SEM) and EDX analysis. Surface gloss (SG) and surface roughness (SR) were evaluated before and after mechanical brushing (n = 10). The outcomes were submitted to 2-way ANOVA and Tukey's test (α = 0.05). Lower mean values of FT were observed for the preheated groups when compared to the non-preheated groups. URH and FSH showed higher mean values of FLS and FLM when compared with UR and FS. No differences were observed between groups in the PSS test. The GW was higher for the UR and FS groups when compared with URH and FSH. The DC was higher for preheated resin composites when compared to the non-preheated groups. The SR of the UR composite was higher than the FS after mechanical brushing, while the SG was higher for the FS groups. In conclusion, the universal resin composite tested generally presented similar physicochemical properties compared with the nanofilled resin composite and either similar or slightly inferior surface properties. The preheating improved or maintained all properties evaluated.
Resumo Neste estudo avaliou-se propriedades físico-químicas e de superfície de um compósito universal pré-aquecido e comparado a um compósito convencional. Foram utilizados dois compósitos comerciais: Filtek Universal Restorative (UR); UR pré-aquecido (URH); Filtek Supreme (FS) e FS pré-aquecido (FSH). O teste de espessura de película (EP) (n = 10) foi feito usando duas placas de vidro sob compressão. A resistência à flexão (RF) e o módulo flexural (MF) foram avaliados por meio do teste de flexão de três pontos (n = 10). A tensão de contração de polimerização (TCP) foi avaliada em uma máquina de teste universal (n = 8). A largura da fenda (LF) entre o compósito e o molde foi medida em moldes metálicos polidos internamente (n = 10). O grau de conversão (GC) foi avaliado por espectroscopia de infravermelho com transformada de Fourier (n = 3). A morfologia das partículas de carga foi observada em microscopia eletrônica de varredura (MEV) e sua composição em EDX. Brilho superficial (BS) e rugosidade superficial (RS) foram avaliados antes e após escovação mecânica (n=10). Os resultados foram submetidos à ANOVA 2-fatores e as médias comparadas pelo teste de Tukey (α = 0,05). Menores valores médios de EP foram observados para os grupos pré-aquecidos quando comparados aos grupos não pré-aquecidos. URH e FSH apresentaram maiores valores médios de RF e MF quando comparados com UR e FS. Não foram observadas diferenças entre os grupos no teste TCP. A LF foi maior para os grupos UR e FS quando comparados com URH e FSH. O GC foi maior para os compósitos pré-aquecidos quando comparados aos não pré-aquecidos. A RS do compósito UR foi maior que o FS após a escovação mecânica, enquanto o BS foi maior para os grupos FS. Em conclusão, o compósito universal testado geralmente apresentou propriedades físico-químicas semelhantes em comparação ao compósito nanoparticulado e propriedades de superfície semelhantes ou ligeiramente inferiores. O pré-aquecimento melhorou ou manteve todas as propriedades avaliadas.
ABSTRACT
This in silico study aimed to evaluate the biomechanical behavior of a full-arch implant-supported prosthesis on titanium and zirconia monotype implants. A 3D mandible containing 1.0 mm thick cortical and cancellous bone was modeled. Four dental implants (3.3 x 10 mm) were inserted into the jaw model in each model. The implants consisted of Titanium (Ti-S group) and Zirconia Monotype/one-piece (Zr-S group). Fixed full-arch implant-supported prostheses were cemented onto the implant. The models were exported to the analysis software and divided into meshes composed of nodes and tetrahedral elements. All materials were considered isotropic, elastic, and homogeneous. Therefore, all contacts were considered bonded, the mandible model was fixed in all directions, applying a static structural axial load of 300 N on the bottom of the fossa of the left mola r teeth. Microstrain and von-Mises stress (MPa) were adopted as failure criteria. Comparable stress and strain values were shown in the peri-implant bone for both groups. However, the Ti-S group presented a lower stress value (1,155.8 MPa) than the Zr-S group (1,334.2 MPa). Regarding bone tissues, the Ti-S group presented 612 µε and the Zr-S group presented 254 µε. The highest strain peak was observed in bone tissues around the implant closer to the load for both groups. Evaluating monotype zirconia and titanium implants, it is suggested that the greater the rigidity of the implant, the greater the concentration of internal stre sses and the less dissipation to the surrounding tissues. Therefore, monotype ceramic implants composed of yttrium-stabilized tetragonal polycrystalline zirconia may be a viable alternative to titanium implants for full-arch prostheses.
El objetivo de este estudio in silico fue evaluar el comportamiento biomecánico de una prótesis implanto soportada de arcada completa sobre implantes monotipo de titanio y zirconia. Se modeló una mandíbula en 3D que contenía tejido óseo cortical y esponjoso de 1,0 mm de espesor. En cada modelo, se insertaron cuatro implantes dentales (3,3 x 10 mm) en el modelo de mandíbula. Los implantes consistieron en Monotipo de Titanio y Zirconia. Sobre el implante se cementaron prótesis implanto soportadas de arcada completa fija. Los modelos se exportaron al software de análisis y se dividieron en mallas compuestas por nodos y elementos tetraédricos. Todos los materiales se consideraron isotrópicos, elásticos y homogéneos. Por lo tanto, todos los contactos se consideraron cementados, el modelo mandibular se fijó en todas las direcciones, aplicando una carga vertical estructural estática de 300 N en el fondo de la fosa de los dientes molares izquierdos. Se seleccionaron la microesfuerzo y la tensión de Von-Mises (MPa) como criterios de falla. Se mostraron valores de tensión y deformación comparables en el hueso periimplantario para ambos grupos. Sin embargo, el grupo Ti-S presentó un valor de estrés menor (1.155,8 MPa) que el grupo Zr-S (1.334,2 MPa). En cuanto a los tejidos óseos, el grupo Ti-S presentó 612 µε y el grupo Zr-S presentó 254 µε. La mayor concentración de deformación en el tejido óseo se observó en los tejidos alrededor del implante más cerca de la carga para ambos grupos. Al evaluar los implantes monotípicos de zirconia y titanio, se sugiere que cuanto mayor sea la rigidez del implante, mayor será la concentración de tensiones internas y menor la disipación a los tejidos circundantes. Por lo tanto, los implantes cerámicos monotipo compuestos de zirconia policristalina tetragonal estabilizada con itrio pueden ser una alternativa viable a los implantes de titanio para prótesis de arcada completa.
Subject(s)
Dental Implants , Dental Materials , Stress, Mechanical , Biomechanical Phenomena , Finite Element Analysis , Mandible/diagnostic imagingABSTRACT
Introduction: Proximal lesions that exceed the cement enamel limit (ACE) under the gingival margin complicate impressions and the adhesive technique. Compare the magnitude of micro infiltration between conventional resin and bulk fill resin in the cervical margin relocation technique. Materials and Methods: 48 samples of human teeth re-ceived two preparations: occluso-mesial (OM) and occluso-distal (OD) under LAC; first they received the cervical margin relocation technique (RMC) with bulk fill and conventional resin; then restored with semi-direct resinous inlays. Sample analysis: immersion in 50% colloidal silver nitrate solution, 24 hours, 37°C and cut mesiodistally. Observed under a stereoscopic magnifying glass to assess dye penetration and digitally photographed, analyzed with "Image J" software. Results: Sample of 96 cavities in two groups of 48 units; control group restored with conventional resin with incremental technique and study group restored with bulk fill resin, mono-incremental technique. Probabilistic sampling. No statistically significant diffe-rences in percentage of microinfiltrated area between Filtek™ Z250™ and Filtek™ Bulk Fill™ (p-value= 0.68). Discussion: Various studies show that the presence of marginal microinfiltration exist independent of: restorative technique, consistency, adhesive mechanism and polyme-rization technique. The research carried out is no exception, observing a similar degree for both systems. Conclusions: Results allow us to conclude that conventi-onal resin and bulk fill resin did not show significant differences in microleakage percentages for the RMC technique. Outside the study framework, bulk fill resins would have comparative advantages; better behavior against light in depths greater than 2 mm, less sensitivity to the "C" factor, and less clinical time.
Introducción: Las lesiones proximales que superan el límite cemento esmalte (ACE) por debajo del margen gingival complican las impresiones y la técnica adhesiva. Comparar la magnitud de la microinfiltración entre la resina convencional y la resina de relleno en la técnica de reubicación del margen cervical. Materiales y Métodos: 48 muestras de dientes humanos recibieron dos preparaciones: ocluso-mesial (OM) y ocluso-distal (OD) bajo LAC, primero recibieron la técnica de reubicación del margen cervical (RMC) con relleno en bloque y resina convencional; luego restaurado con incrustaciones resinosas semidirectas. Análisis de la muestra: inmersión en solución de nitrato de plata coloidal al 50%, 24 horas, 37°C y corte mesiodistal. Observado bajo una lupa estereoscópica para evaluar la penetración del tinte y fotografiado digitalmente, analizado con el software "Image J". Resultados: Muestra de 96 cavidades en dos grupos de 48 unidades; grupo control restaurado con resina convencional con técnica incremental y grupo estudio restaurado con resina bulk fill, técnica mono-incremental. Muestreo probabilístico. No hubo diferencias estadísticamente significativas en el porcentaje de área microinfiltrada entre Filtek™ Z250™ y Filtek™ Bulk Fill™ (p-value = 0,68) Discusión: Diversos estudios evidencian presencia de microinfiltración marginal, independiente de técnica restauradora, consistencia, mecanismo adhesivo y técnica polimerizadora. La investigación realizada no es excepción, observándose grado similar para ambos sistemas. Conclusiones: Los resultados permiten concluir que resina convencional y resina bulk fill no presentaron diferencias significativas en porcentajes de microinfiltración para técnica RMC. Fuera del marco del estudio, resinas bulk fill tendrían ventajas comparativas; mejor comportamiento frente a la luz en profundidades superiores a 2 mm, menor sensibilidad al factor "C", y menor tiempo clínico.
Subject(s)
Humans , Resins, Synthetic , Dental Leakage , Dental Restoration, Permanent , Dental Polishing/methodsABSTRACT
@#Restorative materials such as conventional glass ionomer cement (CGIC), resin-modified glass ionomer cement (RMGIC), polyacid-modified composite resin (compomer), and giomer have the properties of fluoride release and refill, which may prevent or slow down the progression of caries. The caries resistance of these materials was evaluated according to the following criteria: fluorine-releasing ability, antibacterial activity, mechanical properties and anti-aging properties. The anti-caries effect of these materials mainly depends on the effect of fluoride ions on mineralization. However, materials with strong fluorine release ability, such as CGIC, are mainly used in pediatric dentistry and temporary restoration due to their poor mechanical properties. It is difficult to achieve both fluoride ion release potential and mechanical strength, and there are few materials that can provide ideal mechanical strength while maintaining a high standard of fluoride release. The fluoride releasing and recharging capacity of CGIC, RMGIC, compomer and giomer decrease successively. The trend of material modification, to a certain extent, tends to sacrifice the fluoride release capacity of materials to maintain the ideal mechanical strength. In recent years, scholars have tried to add a variety of fillers to further enhance the anti-cracking ability of materials and add antibacterial agents to compensate for the anti-caries effect to reduce the loss of fluoride release.
ABSTRACT
Abstract This study evaluated physicochemical properties of experimental infiltrants after addition of hydroxyapatite nanoparticles (HAp) or 58S bioactive glass (BAG) and diphenyliodonium hexafluorophosphate (DPI). The resin matrix was composed of TEGDMA/Bis-EMA (3:1), 0.5 mol% CQ, and 1 mol% EDAB. The blends received or not 0.5 mol% DPI and 10% wt BAG or HAp. Icon was used as commercial control. The groups were characterized by XRD, FT-IR spectrometry, and SEM before and after simulated body fluid (SBF) immersion for up to 7 days. Polymerization kinetics (n =3 ), water sorption and solubility (n=10), and viscosity (n = 3) were surveyed. For polymerization kinetics, the samples were polymerized for 5 min and the data were obtained from 40 s and 5 min. Statistical analysis was made using ANOVA and Tukey's test (a = 0.05). After 7 days of SBF immersion, XRD and FT-IR showed that the HAp crystalline phase was present only in the HAp groups. A lower degree of conversion (DC) and polymerization rate were observed for the Icon and BAG groups, whereas HAp showed higher values. For the BAG group, DPI increased polymerization rate and DC in 40 s. After 5 min, all groups presented DC above 80%. In groups with particles, the HAp groups exhibited higher viscosity, whereas DPI groups showed a decrease in viscosity. Icon had the highest water sorption. To conclude, BAG neither improved the physicochemical properties studied, nor did it show bioactive properties. The addition of DPI reduced viscosity caused by particle addition and also attenuated the DC decrease caused by BAG addition. The addition of bioactive particles to infiltrants should be seen with caution because they increase viscosity and may not bring major clinical improvements that justify their use. DPI might be indicated only if any component is added to the infiltrant to act as a compensation mechanism.
ABSTRACT
Objetivo:Investigar a eficácia do selamento de lesão de cárie dentinária em comparação com a remoção parcial de cárie seguida de restauração em molares decíduos. Material e Método: O estudo clínico randomizado foi planejado ser realizado em 60 crianças com idade entre 3 e 8 anos. As crianças foram randomizadas por sorteio, com alocação para os 3 grupos, sendo 20 em cada grupo: Grupo 1 (G1) constituído por crianças que receberam o selamento de cárie com resina fluida; Grupo 2 (G2) com crianças que receberam o selamento de cárie com cimento de ionômero de vidro de alta viscosidade e Grupo controle (G3) com crianças onde a remoção parcial da cárie foi seguida por restauração com cimento de ionômero de vidro resinoso. Foram feitos acompanhamentos clínicos e radiográficos antes e após a intervenção, bem como a cada 4 meses durante 1 ano, investigando-se se houve fratura no selamento ou na restauração (infiltração marginal), paralização, regressão ou evolução do processo carioso nos 3 grupos. Resultados: A amostra foi reduzida para 49 crianças pois durante a fase de controle clínico radiográfico, 11 não foram localizadas por mudança de endereço.O grupo G1 apresentou 50% dos casos com regressão e 50% dos casos em paralização. O grupo G2 apresentou 62,5% dos casos com regressão e 37,5% dos casos com paralização e o grupo G3 com 60% dos casos com regressão e 40% com paralização. Não houve associação estatisticamente significativa entre o tipo de grupo e a progressão da lesão, não havendo diferença entre os grupos (valor de p = 0,74). Conclusão: Não houve diferença entre os grupos quanto à progressão de lesão de cárie quando tratados somente com o selamento com resina fluida ou com cimento de ionômero de vidro de alta viscosidade ou com restauração convencional com cimento de ionômero de vidro resinoso após a remoção do tecido cariado.
Aim: To investigate the effectiveness of sealing a dentin caries lesion compared to the removal of partial caries followed by restoration in deciduous molars. Methods: The randomized clinical trial was planned to be performed on 60 children, aged 3 to 8 years. Children were randomized by lot, with allocation into 3 groups, 20 per group: Group 1 (G1) consisted of children who received a sealing of caries using fluid resin; Group 2(G2) included children who received the sealing of caries performed with high viscosity glass ionomer cement, and Group 3(G3) conducted with children where the removal of partial caries was followed by restoration with resinous glass ionomer cement. Clinical and radiographic follow-ups were performed before and after the intervention, as well as every four months for one year, investigating whether there was a fracture in the sealing or restoration (marginal infiltration), paralysis, regression, or evolution of the carious process in the three groups. Results: The sample was reduced to 49 children given that, during the radiographic clinical control phase, 11 were not located due to a change of address. The G1 group presented 50% cases with regression and 50% cases with paralysis. The G2 group presented 62.5% of the cases with regression and 37.5% of the cases with paralysis, while the G3 group showed 60% of the cases with regression and 40% with paralysis. There was no statistically significant association between the type of group and the progression of the lesion, with no difference found between the groups (p value=0.74). Conclusion: There was no difference between the groups regarding the progression of carious lesions when treated only with fluid resin sealing or with high viscosity glass ionomer cement or with conventional restoration with resinous glass ionomer cement after the removal of decayed tissue.
Subject(s)
Child , Treatment Outcome , Dental Caries , Dental MaterialsABSTRACT
Atualmente, diversos materiais restauradores encontram-se disponíveis para aplicabilidade em Odontopediatria. Os avanços dos materiais restauradores conduzem à necessidade de novos estudos nessa temática. O presente estudo apresenta duas propostas de investigação: 1) Estudo transversal com objetivo de avaliar a preferência de pais/responsáveis e crianças quanto ao emprego do compômero colorido (Twinky Star®, Voco, Alemanha); 2) Estudo bibliométrico altimétrico com objetivo de analisar 50 artigos mais citados referente aos materiais restauradores utilizados em Odontopediatria e o alcance dessa informação científica nas mídias on-line. O estudo transversal envolveu 260 pares de pais/responsáveis e crianças de 5 a 11 anos de idade de dois serviços de saúde da região metropolitana de Belo Horizonte-MG. Exame quanto à cárie dentária foi realizado por examinadora calibrada para o critério da Organização Mundial da Saúde. Um manequim odontológico contendo restaurações com compômeros coloridos e materiais convencionais (resina composta, ionômero de vidro e amálgama) foi apresentado aos participantes do estudo e realizou-se inquérito sobre a preferência dos materiais dentários. O Questionário de Estilo e Dimensões dos Pais (PSDQ) e o Eysenck Personality Questionnaire Junior (EPQ-J) foram aplicados, este último apenas para pais/responsáveis de crianças de 5 e 6 anos de idade. Análises descritivas, bivariadas e regressão multivariada de Poisson foram realizadas. A maioria dos pais/responsáveis (74,2%) preferiu materiais convencionais. A idade da criança (p=0,006), a renda familiar (p= 0,001) e o nível de escolaridade (p< 0,001) associaram se a essa escolha. A análise multivariada demonstrou que crianças menores de 7 anos apresentaram 1,20 vezes maior probabilidade de escolher compômeros coloridos do que seus pares mais velhos (p< 0,001), assim como pais/responsáveis com menos de 11 anos de escolaridade e cujos filhos eram menores de 7 anos apresentaram 2,17 e 1,74 maior probabilidade para escolher compômeros coloridos, respectivamente. Concluiu-se que responsáveis com maior escolaridade apresentaram maior resistência às restaurações coloridas e crianças menores de 7 anos aceitaram melhor este material. O estudo bibliométrico-altimétrico adotou estratégia de busca em três bases (Web of Science, Scopus e Google Scholar), independente da data de publicação. Após seleção dos artigos por um grupo de cinco pesquisadores, em março de 2023, foram incluídos estudos que avaliassem qualquer material restaurador empregado em dentes decíduos e analisados dados referentes ao título, número de citações, país/continente, autoria, periódico, instituição, desenho do estudo, tipo de material restaurador, e escore altimétrico. Os artigos, publicados entre 1991 a 2002, apresentaram variação de citações de 19 a 113. Os autores com maior número de citações foram Qvist V e Teglers PT. O estudo experimental foi o principal delineamento de estudo observado e o cimento de ionomero de vidro foi o material mais reportado. A Europa foi o continente, e o Brasil, o país com maior número de citações. O escore altimétrico esteve presente em 23 artigos, com ênfase para dois artigos (43/6º e 73/7º). Concluiu-se que o cimento de ionômero de vidro foi o material mais estudado. Ficou evidente o distanciamento entre a posição dos trabalhos nas análises bibliométrica e altimétrica, apontando necessidade de disseminação da informação além dos círculos acadêmicos.
Currently, an arsenal of restorative materials is available for applicability in pediatric dentistry. The advances in restorative materials conducted to need for further studies in this thematic. The present study presents two investigation proposals: 1) Cross-sectional study aiming to evaluate the preference of parents and children regarding the use of colored compomer (Twinky Star®, Voco, Germany); 2) Bibliometric-altmetric study aiming to analyze the 50-most cited papers regarding to restorative materials used in pediatric dentistry and the dissemination of scientific information in online media. The cross-sectional study included 260 pairs of caregivers/children aged 5 to 11, in two public health services, in the metropolitan region of Belo Horizonte-MG. Examination for dental caries was performed by an examiner calibrated to the criteria of the World Health Organization. A dental mannequin containing colored compomers restorations and conventional materials (composite resin, glass ionomer cement and dental amalgam) was presented to the population and a survey was conducted about the preference of dental materials. Parents' Style and Dimensions Questionnaire (PSDQ) and Eysenck Personality Questionnaire Junior (EPQ-J) were applied, the last one only for parents/caregivers of children aged 5 to 6. Descriptive, bivariate and Poisson regression analyzes were performed. Most adults (74.2%) preferred conventional materials. Family income (p= 0.001) and education level (p< 0.001) were associated with its choice. Age up to 7 (p< 0.001) associated with children's choice for colored restorations (72.3%). Children younger than 7 had 1.20 higher probability to choose colored compomers than their older pairs, while adults with children younger than 7 and less than 11 years of schooling had 1.74 and 2.17 higher probability to choose colored compomers, respectively. It was concluded that caregivers with higher educational level showed greater resistance to use of colored restorations and children younger than 7 had better acceptance of colored material. The bibliometrics-altmetrics study adopted a search strategy in three databases (Web of Science, Scopus and Google Scholar), independent of the year of publication. After selection of papers by a panel of five researchers, in March 2023, any restorative material used in deciduous teeth was included and data about the title, number of citations, country/continent, authorship, journal, design of the study, type of restorative material, university and altmetrics score were analyzed. The papers, published between 1991 and 2002, ranged from 19 to 113 citations. The authors with the highest number of citations were Qvist V and Teglers PT. The experimental study was the main study design observed. Analyzing the continent and country with the highest number of citations, Europe highlighted and Brazil was predominant. The altmetric score was present in 23 papers, emphasizing two articles (43/6th and 73/7th). It was concluded that glass ionomer cement was the most studied material. A gap between the position of the papers correlating the bibliometrics and altmetrics analyzes was evident, demonstrating the need to disseminate the information beyond academic circles.
Subject(s)
Bibliometrics , Pediatric Dentistry , Compomers , Dental Amalgam , Dental MaterialsABSTRACT
Com base no desenvolvimento da odontologia adesiva, restaurações minimamente invasivas em cerâmica são utilizadas como alternativas para restaurar um dente. As cerâmicas odontológicas são amplamente aplicadas na área odontológica principalmente devido à sua estética e resistência mecânica. Uma das propriedades da cerâmica a ser bem conhecida antes de seu uso, é a resistência ao desgaste que deve ser compatível com o comportamento de desgaste do antagonista para evitar desempenhos indesejados. Portanto, vários métodos têm sido realizados para avaliar o comportamento do desgaste dos materiais cerâmicos considerando diferentes condições presentes no complexo meio oral. Este estudo teve como objetivo compilar os métodos utilizados para investigar o desgaste das cerâmicas odontológicas e descrever os mecanismos de desgaste envolvidos nos mesmos. A obtenção e análise de dados também é abordada para discutir os resultados obtidos a partir de diferentes métodos, bem como a análise clínica do desgaste e perspectivas futuras sobre esse tema. Em conclusão, muitas metodologias estão disponíveis para medir o desgaste cerâmico. Portanto, os métodos devem ser selecionados com base na relevência clínica de cada estudo e devem seguir parâmetros previamente relatados para padronização, permitindo a comparação da literatura (AU)
Based on the development of adhesive dentistry, minimally invasive restorations in ceramics are used as alternatives to restore a tooth. Dental ceramics are largely applied in the dentistry field mainly due to their esthetic and mechanical strength. One of the ceramic properties to be well known before its use is the wear resistance that should be compatible with the antagonist wear behavior to avoid unwanted performance. Therefore, several methods have been performed to assess the ceramic materials wear behavior considering different conditions present in the complex oral medium. This study aimed to compile the methods used to investigate dental ceramics wear and to describe the wear mechanisms involved on them. Obtaining and analyzing data is also addressed to discuss the results obtained from different methods, as well as the clinical analysis of wear and future perspectives on this topic. In conclusion, many methodologies are available to measure the ceramic wear. Therefore, the methods must be selected based on the clinical significance of each study and should follow previously reported parameters for standardization, allowing literature comparison. (AU)