Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 190
Filter
1.
Article in Chinese | WPRIM | ID: wpr-1022954

ABSTRACT

Objective To establish a stable and reliable method for the determination of ethylene oxide residue,and to analyze ethylene oxide residue in multi components made of different materials involved in some medical devices,so as to provide references for sample selection and ethylene oxide residue detection of multi-component medical device kits.Methods A method for the determination of ethylene oxide residue of multi-component medical devices was developed using headspace-gas chromatography and DB-WAX column under the conditions of headspace extraction with equilibration at 80℃ for 20 min,and the weighing mass,linearity,limit of detection,limit of quantification,precision and recovery of the method were determined.Trials of the method were carried out on the items undergoing ethylene oxide sterilization,including disposable perineal care kit,disposable gynecological examination kit,disposable suture dressing kit,disposable debridement kit and the components contacting human body in the disposable dialysis kit,and the abilities of different materials of the components were analyzed in absorbing,retaining and releasing ethylene oxide.Results The method showed high linearity(r=0.999 8)in the range of ethylene oxide mass concentration from 0.4 to 16.0 μg/mL with a weighing mass of 1.00 g,which had the limit of detection being 0.11 μg/mL,the limit of quantification being 0.37 μg/mL and the relative standard deviations(RSDs)for the precision from 0.35%to 1.52%.The average recoveries of different spiked amounts of ethylene oxide in the three blank matrices ranged from 92.68%to 101.42%with the relative standard deviations(RSDs)from 2.46%to 7.59%,which all satisfied the detection requirements.The components made of rubber and acrylonitrile-butadiene-styrene copolymer(ABS)in multi-component medical device kits had the highest ethylene oxide residues,followed by the components made of wood,degreased cotton,polypropylene and polystyrene.Conclusion The method proposed gains advantages in easy operation and high specificity,quantification and reproducibility,which can be used for the determination of ethylene oxide residue in the multi-component medical device kit undergoing ethylene oxide sterilization.References are provided for sample selection of multi-component medical devices.[Chinese Medical Equipment Journal,2024,45(1):56-61]

2.
Rev. Bras. Ortop. (Online) ; 58(2): 284-289, Mar.-Apr. 2023. tab, graf
Article in English | LILACS | ID: biblio-1449810

ABSTRACT

Abstract Objective Due to the popularity of 3D technology, surgeons can create specific surgical guides and sterilize them in their institutions. The aim of the present study is to compare the efficacy of the autoclave and ethylene oxide (EO) sterilization methods for objects produced by 3D printing with polylactic acid (PLA) material. Methods Forty cubic-shaped objects were printed with PLA material. Twenty were solid and 20 were hollow (printed with little internal filling). Twenty objects (10 solid and 10 hollow) were sterilized in autoclave, forming Group 1. The others (10 solid and 10 hollow) were sterilized in EO, composing Group 2. After sterilization, they were stored and referred to culture. Hollow objects of both groups were broken during sowing, communicating the dead space with the culture medium. The results obtained were statistically analyzed (Fisher exact test and residue analysis). Results In group 1 (autoclave), there was bacterial growth in 50% of solid objects and in 30% of hollow objects. In group 2 (EO), growth occurred in 20% of hollow objects, with no bacterial growth in solid objects (100% of negative samples). The bacteria isolated in the positive cases was non-coagulase-producing Staphylococcus Gram positive. Conclusions Sterilization by both autoclave and EO was not effective for hollow printed objects. Solid objects sterilized by autoclave did not demonstrate 100% of negative samples and were not safe in the present assay. Complete absence of contamination occurred only with solid objects sterilized by EO, which is the combination recommended by the authors.


Resumo Objetivo Devido à popularidade da tecnologia 3D, cirurgiões podem criar guias cirúrgicos específicos e esterilizá-los nas suas instituições. O objetivo do presente estudo é comparar a eficácia dos métodos de esterilização por autoclave e óxido de etileno (OE) de objetos produzidos pela impressão 3D com material ácido polilático (PLA, na sigla em inglês). Métodos Quarenta objetos em formato cúbico foram impressos com material de PLA. Vinte eram sólidos e 20 eram ocos (impressos com pouco enchimento interno). Vinte objetos (10 sólidos e 10 ocos) foram esterilizados em autoclave, formando o Grupo 1. Os demais (10 sólidos e 10 ocos) foram esterilizados em OE, compondo o Grupo 2. Após a esterilização, os objetos foram armazenados e encaminhados para cultura. Objetos ocos de ambos os grupos foram quebrados durante a semeadura, comunicando o espaço morto com o meio de cultura. Os resultados obtidos foram analisados estatisticamente (teste exato de Fisher e análise de resíduo). Resultados No grupo 1 (autoclave) houve crescimento bacteriano em 50% dos objetos sólidos e em 30% dos objetos ocos. No grupo 2 (OE) o crescimento ocorreu em 20% dos objetos ocos, com ausência de crescimento bacteriano nos objetos sólidos (100% de amostras negativas). A bactéria isolada nos casos positivos foi Staphylococcus Gram positivo não produtor de coagulase. Conclusões A esterilização tanto em autoclave quanto pelo OE não foi eficaz para objetos impressos no formato oco. Objetos sólidos esterilizados em autoclave não demonstraram 100% de amostras negativas, não sendo seguro no presente ensaio. Ausência completa de contaminação ocorreu apenas com objetos sólidos esterilizados pelo OE, sendo a combinação recomendada pelos autores.


Subject(s)
Humans , Arthroplasty, Replacement, Hip/rehabilitation , Analgesia , Injections, Intra-Articular
3.
Bol. latinoam. Caribe plantas med. aromát ; 22(2): 224-236, mar. 2023. tab, graf
Article in English | LILACS | ID: biblio-1555667

ABSTRACT

The objective was to evaluate plant growth regulators and ethylene inhibitors on the development and leaf abscission of Schinopsis brasiliensis Engl. Zeatin (ZEA) was evaluated in concentrations combined with concentrations of indolacetic acid (IAA), naphthalene acetic acid (NAA) and indolbutyric acid (IBA). ZEA and 6-benzylamino purine (BAP) were evaluated in concentrations plus a control. Ethylene inhibitors, silver nitrate and cobalt chloride were evaluated in four concentrations. The addition of 0.2 µL-1 of NAA to 0.4 µL-1 of ZEA promotes a greater number of baraúna sprouts. At concentrations of 5 and 10 µM, cobalt chloride is more efficient than silver nitrate for reducing leaf abscission in baraúna. IAA is the most suitable auxin to be associated with ZEA for higher shoot length and number of buds. Silver nitrate from a concentration of 20 µM completely avoids leaf abscission whilecobalt chloride has a maximum reduction in abscission at a concentration of 40 µM.


El objetivo fue evaluar reguladores de crecimiento e inhibidores de etileno sobre el desarrollo y abscisión foliar en Schinopsis brasiliensis Engl. La zeatina (ZEA) se evaluó en concentraciones combinadas con concentraciones de ácido indolacético (IAA), ácido naftaleno acético (NAA) y ácido indolbutírico (IBA). Se evaluaron ZEA y 6-bencilamino purina (BAP) en concentraciones más un control. Se evaluaron inhibidores de etileno, nitrato de plata y cloruro de cobalto, en cuatro concentraciones. La adición de 0.2 µL-1 de NAA a 0.4 µL-1 de ZEA promueve un mayor número de brotes de baraúna. A concentraciones de 5 y 10 µM, el cloruro de cobalto es más eficaz que el nitrato de plata para reducir la abscisión de las hojas en baraúna. IAA es la auxina más adecuada para asociar con ZEA para una mayor longitud de brotes y número de brotes. El nitrato de plata a partir de una concentración de 20 µM evita completamente la abscisión de las hojas, mientras que el cloruro de cobalto tiene una reducción máxima en la abscisión a una concentración de 40 µM.


Subject(s)
Anacardiaceae/growth & development , Zeatin , In Vitro Techniques , Ethylenes
4.
Chinese Journal of Biotechnology ; (12): 1883-1888, 2023.
Article in Chinese | WPRIM | ID: wpr-981177

ABSTRACT

The large scale production and indiscriminate use of plastics led to serious environmental pollution. To reduce the negative effects of plastics waste on the environment, an approach of enzymatic degradation was put forward to catalyze plastics degradation. Protein engineering strategies have been applied to improve the plastics degrading enzyme properties such as activity and thermal stability. In addition, polymer binding modules were found to accelerate the enzymatic degradation of plastics. In this article, we introduced a recent work published in Chem Catalysis, which studied the role of binding modules in enzymatic hydrolysis of poly(ethylene terephthalate) (PET) at high-solids loadings. Graham et al. found that binding modules accelerated PET enzymatic degradation at low PET loading (< 10 wt%) and the enhanced degradation cannot be observed at high PET loading (10 wt%-20 wt%). This work is beneficial for the industrial application of polymer binding modules in plastics degradation.


Subject(s)
Polyethylene Terephthalates/metabolism , Polymers , Plastics , Ethylenes
5.
Chinese Journal of Biotechnology ; (12): 1998-2014, 2023.
Article in Chinese | WPRIM | ID: wpr-981185

ABSTRACT

Plastics have brought invaluable convenience to human life since it was firstly synthesized in the last century. However, the stable polymer structure of plastics led to the continuous accumulation of plastic wastes, which poses serious threats to the ecological environment and human health. Poly(ethylene terephthalate) (PET) is the most widely produced polyester plastics. Recent researches on PET hydrolases have shown great potential of enzymatic degradation and recycling of plastics. Meanwhile, the biodegradation pathway of PET has become a reference model for the biodegradation of other plastics. This review summarizes the sources of PET hydrolases and their degradation capacity, degradation mechanism of PET by the most representative PET hydrolase-IsPETase, and recently reported highly efficient degrading enzymes through enzyme engineering. The advances of PET hydrolases may facilitate the research on the degradation mechanism of PET and further exploration and engineering of efficient PET degradation enzymes.


Subject(s)
Humans , Hydrolases/metabolism , Polyethylene Terephthalates/metabolism , Plastics/metabolism , Ethylenes
6.
Chinese Journal of Biotechnology ; (12): 2027-2039, 2023.
Article in Chinese | WPRIM | ID: wpr-981187

ABSTRACT

The discovery of new enzymes for poly(ethylene terephthalate) (PET) degradation has been a hot topic of research globally. Bis-(2-hydroxyethyl) terephthalate (BHET) is an intermediate compound in the degradation of PET and competes with PET for the substrate binding site of the PET-degrading enzyme, thereby inhibiting further degradation of PET. Discovery of new BHET degradation enzymes may contribute to improving the degradation efficiency of PET. In this paper, we discovered a hydrolase gene sle (ID: CP064192.1, 5085270-5086049) from Saccharothrix luteola, which can hydrolyze BHET into mono-(2-hydroxyethyl) terephthalate (MHET) and terephthalic acid (TPA). BHET hydrolase (Sle) was heterologously expressed in Escherichia coli using a recombinant plasmid, and the highest protein expression was achieved at a final concentration of 0.4 mmol/L of isopropyl-β-d-thiogalactoside (IPTG), an induction duration of 12 h and an induction temperature of 20 ℃. The recombinant Sle was purified by nickel affinity chromatography, anion exchange chromatography, and gel filtration chromatography, and its enzymatic properties were also characterized. The optimum temperature and pH of Sle were 35 ℃ and 8.0, and more than 80% of the enzyme activity could be maintained in the range of 25-35 ℃ and pH 7.0-9.0 and Co2+ could improve the enzyme activity. Sle belongs to the dienelactone hydrolase (DLH) superfamily and possesses the typical catalytic triad of the family, and the predicted catalytic sites are S129, D175, and H207. Finally, the enzyme was identified as a BHET degrading enzyme by high performance liquid chromatography (HPLC). This study provides a new enzyme resource for the efficient enzymatic degradation of PET plastics.


Subject(s)
Actinomycetales/genetics , Hydrolases/metabolism , Phthalic Acids/chemistry , Polyethylene Terephthalates/metabolism
7.
Chinese Journal of Biotechnology ; (12): 603-613, 2023.
Article in Chinese | WPRIM | ID: wpr-970394

ABSTRACT

ACC oxidase (ACO) is one of the key enzymes that catalyze the synthesis of ethylene. Ethylene is involved in salt stress response in plants, and salt stress seriously affects the yield of peanut. In this study, AhACO genes were cloned and their functions were investigated with the aim to explore the biological function of AhACOs in salt stress response, and to provide genetic resources for the breeding of salt-tolerant varieties of peanut. AhACO1 and AhACO2 were amplified from the cDNA of salt-tolerant peanut mutant M29, respectively, and cloned into the plant expression vector pCAMBIA super1300. The recombinant plasmid was transformed into Huayu22 by pollen tube injection mediated by Agrobacterium tumefaciens. After harvest, the small slice cotyledon was separated from the kernel, and the positive seeds were screened by PCR. The expression of AhACO genes was analyzed by qRT-PCR, and the ethylene release was detected by capillary column gas chromatography. Transgenic seeds were sowed and then irrigated with NaCl solution, and the phenotypic changes of 21-day-seedings were recorded. The results showed that the growth of transgenic plants were better than that of the control group Huayu 22 upon salt stress, and the relative content of chlorophyll SPAD value and net photosynthetic rate (Pn) of transgenic peanuts were higher than those of the control group. In addition, the ethylene production of AhACO1 and AhACO2 transgenic plants were 2.79 and 1.87 times higher than that of control peanut, respectively. These results showed that AhACO1 and AhACO2 could significantly improve the salt stress tolerance of transgenic peanut.


Subject(s)
Salt Tolerance/genetics , Arachis/genetics , Plant Breeding , Ethylenes/metabolism , Plants, Genetically Modified/genetics , Gene Expression Regulation, Plant , Plant Proteins/genetics
8.
Article in Chinese | WPRIM | ID: wpr-993552

ABSTRACT

Objective:To explore the β-amyloid (Aβ) deposition pattern of subjects with the preclinical Alzheimer′s disease (AD), community-derived amnestic mild cognitive impairment (aMCI) and normal cognition (NC) from communities of Shanghai.Methods:According to the inclusion and exclusion criteria, 273 subjects (104 males, 169 females; age (64.2±7.6) years) were recruited from Shanghai community and memory clinics from December 2018 to July 2020. All subjects underwent MRI, 18F-AV45 PET imaging and neuropsychological scale tests and were grouped into AD, aMCI and NC groups based on clinical diagnosis. Differences in demographic information, the neuropsychological scale tests′ scores and positive rate of Aβ deposition among each group were analyzed by one-way analysis of variance or χ2 test. Aβ deposition patterns of AD and MCI groups were analyzed at voxel level, and the differences of Aβ deposition among different groups were compared. Results:Among 273 patients, the positive rates of Aβ deposition in AD, aMCI and NC groups were 84.4%(38/45), 36.4%(20/55) and 23.1%(40/173), respectively ( χ2=58.37, P<0.001). Among AD, aMCI, NC and NC (Aβ-) groups ( n=132), the education years of AD group was the lowest ((9.7±4.6) years; F=8.86, P<0.001). In addition, there were significant differences in the scores of several neuropsychological scale tests among AD, aMCI, NC groups and NC (Aβ-) group ( F values: 27.68-235.50, all P<0.001). Compared with subjects in NC(Aβ-) group, the Aβ depositions in the aMCI and AD groups were widely distributed in the whole cerebral cortex; and AD group had higher Aβ deposition in bilateral frontal, parietal, temporal, occipital lobe, cingulate gyrus and precuneus than aMCI group. Conclusions:The positive rate of Aβ deposition in the preclinical AD population from the Shanghai community is obtained. There are significant different Aβ deposition patterns in subjects at different stages of AD.

9.
Article in Chinese | WPRIM | ID: wpr-993558

ABSTRACT

Objective:To explore the association of the impaired cognition and the deposition of β-amyloid (Aβ) in normal cognitive (NC) and mild cognitive impairment (MCI).Methods:From December 2018 to January 2021, 305 subjects (113 males, 192 females; age (64.0±7.7) years) who completed neuropsychological tests and MRI in Shanghai Sixth People′s Hospital, Shanghai Jiao Tong University and 18F-florbetapir (AV45) PET imaging in Huashan Hospital, Fudan University were retrospectively analyzed. The subjects were divided into MCI group and NC group based on neuropsychological tests, and each group was further divided into Aβ-positive and Aβ-negative based on PET imaging results. Independent-sample t test, Mann-Whitney U test and χ2 test were used to analyze the data. Results:There were 118 subjects in MCI group and 187 subjects in NC group. The Aβ-positive rate in MCI group (37.3%, 44/118) was higher than that in NC group (26.2%, 49/187; χ2=4.19, P=0.041). The assessment performances of MCI group in general cognitive function, memory function, language function and executive function were inferior to those of NC group ( t values: from -10.63 to -6.31, z values: from -11.01 to -6.03, all P<0.001). The Auditory Verbal Learning Test-Long Delay Recall (AVLT-LDR) score of Aβ-positive subjects was lower than that of Aβ-negative subjects in MCI group (1.00(0.00, 3.00) and 3.00(1.00, 4.00); z=-2.49, P=0.013). The Montreal Cognitive Assessment Basic (MoCA-B) score of Aβ-positive subjects was lower than that of Aβ-negative subjects in NC group (25.29±2.67 and 26.36±2.42; t=-2.61, P=0.010). Conclusion:Compared to Aβ-negative subjects, MCI patients with Aβ-positive perform worse on memory tests, and NC subjects with Aβ-positive perform worse on general cognitive function.

10.
Article in Chinese | WPRIM | ID: wpr-995383

ABSTRACT

Objective:To explore the value of linaclotide combined with compound polyethylene glycol electrolytes powder (PEG) for bowel preparation for colonoscopy.Methods:A randomized and single blind prospective clinical study was conducted in patients who intended to receive colonoscopy at the Department of Gastroenterology in Shenzhen Hospital, Southern Medical University from June 2021 to August 2021. One hundred and fifty-two patients in the experimental group were treated with 580 μg linaclotide + 2 L PEG, and 152 patients in the control group were treated with 3 L PEG. The bowel preparation effects including Boston bowel preparation scale (BBPS) score, bubble score and lesion detection rate, and safety (adverse events) were compared between the two groups.Results:The total BBPS scores were 9 (8, 9) in the experimental group, and 9 (9, 9) in the control group with no significant difference ( Z=0.141, P=0.888). The bubble scores were 1 (1, 2) in the experimental group, and 1 (1, 1) in the control group with no significant difference ( Z=1.788, P=0.074). There was no significant difference in detection rate of lesions between the experimental group and the control group [37.50% (57/152) VS 33.55% (51/152), χ2=0.517, P=0.472]. There was no significant difference in safety including incidence of nausea [7.24% (11/152) VS 13.16% (20/152), χ2=2.910, P=0.088], vomiting [2.63% (4/152) VS 7.24% (11/152), χ2=3.436, P=0.064], abdominal distension [7.89% (12/152) VS 11.84% (18/152), χ2=1.331, P=0.249] and abdominal pain [2.63% (4/152) VS 4.61% (7/152), χ2=0.849, P=0.357] between the experimental group and the control group. Conclusion:Linaclotide combined with PEG for colonoscopic bowel preparation reduces drinking water volume. The cleaning effect and safety are comparable to using 3 L PEG. It can be recommended for bowel preparation for colonoscopy.

SELECTION OF CITATIONS
SEARCH DETAIL