Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Odovtos (En línea) ; 24(3)dic. 2022.
Article in English | LILACS, SaludCR | ID: biblio-1406167

ABSTRACT

Abstract The purpose of this study was to compare the effect of different disinfection protocols of dentin on bond strength of an MDP-containing universal adhesive. Twelve extracted mandibular third molars were separated horizontally at the mid-coronal of crown to get smooth and sound dentin surfaces using low-speed diamond saw. The teeth were randomly fallen into four groups: chlorhexidine (CHX), ozone, Er,Cr:YSGG laser irradiation (LASER) and no treatment (control). After cavity disinfection application, a universal adhesive (G-Premio Bond) was applied to the surface of dentin according to self-etch mode as instructed by the manufacturer. After incremental built-up of composite resin (Charisma Smart), the specimens were immersed in distilled water at 37°C for 24h. Dentin/composite beams with 1 mm² cross sectional area were produced and micro-tensile bond strength (µTBS) was applied on these beams (n=20). Failure mods were determined under a stereomicroscope at ×40. The resin penetration of samples stained with Rhodamine B fluorochrome dye was examined with a confocal laser scanning microscope. Statistical analysis was performed with SPSS-22. Test results were analyzed using One-way Anova and Tukey HSD Post-Hoc tests (p0.5). All applications of cavity disinfection procedures decreased the µTBS of the resin-dentin interface.


Resumen El propósito de este estudio fue comparar el efecto de diferentes protocolos de desinfección de la dentina sobre la fuerza de unión de un adhesivo universal que contiene MDP. Doce terceros molares mandibulares extraídos se quebraron horizontalmente en la mitad de la corona para obtener superficies de dentina lisas y sólidas utilizando una sierra de diamante de baja velocidad. Los dientes se dividieron aleatoriamente en cuatro grupos: clorhexidina (CHX), ozono, irradiación con láser Er,Cr:YSGG (LASER) y ningún tratamiento (control). Después de la aplicación de la desinfección de la cavidad, se aplicó un adhesivo universal (G-Premio Bond) a la superficie de la dentina según el modo de autograbado indicado por el fabricante. Después de la obturación con resina compuesta (Charisma Smart), las muestras se sumergieron en agua destilada a 37°C durante 24h. Se produjeron porciones de dentina/resina con un área de sección transversal de 1 mm² y se aplicó una fuerza de adhesión microtensile (µTBS) (n=20). Los modos de falla se determinaron bajo un microscopio estereoscópico a ×40. La penetración de la resina de las muestras teñidas con colorante fluorocromo rodamina B se examinó con un microscopio de barrido láser confocal. El análisis estadístico se realizó con SPSS-22. Los resultados de las pruebas se analizaron utilizando las pruebas post-hoc Anova unidireccional y Tukey HSD (p0.5). Todas las aplicaciones de procedimientos de desinfección de cavidades redujeron el µTBS de la interfaz resina-dentina.


Subject(s)
Humans , Disinfection , Disinfectants/therapeutic use , Mouth , Turkey
2.
Rev. cuba. estomatol ; 58(4)dic. 2021.
Article in Spanish | LILACS, CUMED | ID: biblio-1408356

ABSTRACT

Introducción: Es frecuente el desprendimiento de los espigos de fibra de vidrio por pérdida de adhesión cuando son sometidos a las fuerzas masticatorias. Objetivo: Comparar in vitro la resistencia a las fuerzas de tracción de espigos de fibra de vidrio y anatomizado con un mismo cemento. Métodos: Estudio in vitro, de tipo experimental. Se seleccionaron 20 premolares extraídos por motivos ortodónticos que fueron distribuidos aleatoriamente en dos grupos. Se les realizó el tratamiento de conductos por un especialista, la preparación fue manual y la técnica de obturación por condensación lateral. Los dientes fueron preparados para, en forma estándar, recibir el espigo de fibra de vidrio y anatomizados con resina. Para ambos grupos la cementación siguió el protocolo sugerido por el fabricante de Allcem Core® (cemento dual). Los especímenes fueron troquelados en acrílico de autocurado. Para luego ser sometido a fuerza de tracción vertical en la máquina de pruebas de materiales (Instrom©). Resultados: En el grupo de dientes con espigos anatomizados se obtuvo una media de 31 Kg/F, postes de fibra de vidrio 12,47 Kg/F. Según las pruebas de Shapiro-Wilk, las muestras presentaron distribución normal (p > 0,05). Se contrastó la hipótesis con la prueba de t de Student y se encontró diferencia estadística altamente significativas entre los grupos (p = 0,001) Conclusiones: Existe una mayor resistencia a la tracción vertical en los espigos anatomizados(AU)


Introduction: Fiberglass posts often fall off their position due to loss of adhesive capacity when they are subjected to masticatory force. Objective: Compare in vitro the tensile bond strength of fiberglass and anatomized posts cemented with the same adhesive material. Methods: An in vitro experimental study was conducted. A selection was made of 20 premolars extracted by orthodontic indication which were then randomly distributed into two groups. The premolars underwent root canal treatment by a specialist. The preparation was manual and sealing was performed by lateral condensation. The teeth were prepared in the standard manner to receive the fiberglass and resin-anatomized posts. In both groups' cementation followed the protocol suggested by the manufacturer of Allcem Core® (dual cement). The specimens were stamped in self-curing acrylic. Next, they were subjected to vertical tensile strength in an materials testing machine (Instrom©). Results: The mean values obtained were 31 kg/F for teeth with anatomized posts and 12.47 kg/F for fiberglass posts. According to Shapiro-Wilk tests, the samples exhibited a normal distribution (p > 0.05). The hypothesis was contrasted with Student's t test, obtaining a highly significant statistical difference between the groups (p = 0.001). Conclusions: Vertical tensile bond strength is greater in anatomized posts(AU)


Subject(s)
Humans , Bite Force , Dental Cements/adverse effects , Tensile Strength
3.
Int. j. odontostomatol. (Print) ; 14(1): 109-116, mar. 2020. tab, graf
Article in Spanish | LILACS | ID: biblio-1056509

ABSTRACT

RESUMEN: Paredes sin instrumentar y con material obturador endodóntico residual pueden elevar la posibilidad de la falla adhesiva de postes de fibroresina. Las fresas de desobturación y conformación del espacio protésico poseen una sección circular, lo que dificulta una adecuada preparación y limpieza de las paredes de los conductos ovales. El objetivo del presente estudio fue evaluar la capacidad de limpieza ultrasónica del espacio protésico y cómo ésta influyó en la resistencia a la tracción de postes de fibroresina en conductos ovales. Se utilizaron 30 premolares con conducto ovalado divididos aleatoriamente en 3 grupos de estudio (n=10), siendo: grupo A: preparación rotatoria con complemento ultrasónico, grupo B: preparación rotatoria y grupo C: grupo control. Postes de fibra de vidrio fueron cementados y luego de 7 días se realizaron cortes de un milímetro de grosor del tercio cervical y medio de cada muestra y se evaluó microscópicamente el área de gutapercha remanente y área efectiva de adhesión. Estos fueron sometidos a una prueba de push out evaluando la resistencia adhesiva de los postes. Finalmente fueron observados microscópicamente para analizar tipo de falla. Los resultados se analizaron mediante el test de ANOVA, Bonferroni, Kruskal-Wallis y Mann Whitney (p < 0.05), registrando diferencias estadísticamente significativas en la resistencia a tracción, área de gutapercha remanente y área disponible para la adhesión; además de una relación directa entre gutapercha remanente y menor resistencia a la tracción. Conclusiones: La preparación ultrasónica del espacio protésico aumenta la resistencia a la tracción de postes de fibroresinas cementados en conductos ovalados.


ABSTRACT: Untouched canal walls with residual filling materials can increase the probability of adhesive failure of fiber posts. The drills used for desobturation and conformation of the prosthetic space, has a circular cross section, which does not allow a proper preparation and cleaning of oval-shaped canal walls. The objective of the study was to evaluate the ultrasonic cleaning of the prosthetic space and how this influences the adhesive strength of fiber posts in oval-shaped canals. Thirty (30) oval-shaped canal premolars were randomly divided into 3 groups (n = 10): Group A: rotary desobturation with ultrasonic complement, group B: rotary desobturation without ultrasonic complement and group C: control group. Fiberglass posts were cemented; after 7 days, one-millimeter slices were performed, one of the cervical and another from the middle third of the root. The slices were analyzed under an optical microscope to evaluate remaining gutta percha and effective adhesion area. Samples were subjected to a push-out test to evaluate bond strength of the fiber resin posts. Finally, samples were evaluated microscopically to analyze the type of failure. The results were analyzed using ANOVA, Bonferroni, KruskalWallis and Mann Whitney test (p < 0.05), recording statistically significant differences in bond strength, remaining gutta-percha area and clean walls for adhesion; In addition, to a direct relationship between remaining gutta percha and lower adhesive strength, the ultrasonic preparation of the prosthetic space increases bond strength of fiber posts in oval canals.


Subject(s)
Humans , Osteotomy/methods , Ultrasonics , Post and Core Technique , Dental Bonding , Root Canal Preparation/instrumentation , Specimen Handling , In Vitro Techniques , Analysis of Variance , Dentin-Bonding Agents , Root Canal Preparation/methods
4.
Odovtos (En línea) ; 19(2)ago. 2017.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1506905

ABSTRACT

14. El propósito de este estudio fue determinar el efecto que ejercen distintos tratmientos de superficie en la fuerza de adhesión entre el cemento de resina y los postes de resina reforzados con fibras de cuarzo. Materiales y métodos: Sesenta postes de fibra de cuarzo (DT Light-Post™, Bisco™) se asignaron aleatoriamente a 12 grupos experimentales (n=5), según el cemento de resina utilizado (Biscem™ o Duolink™) y el tipo de tratamiento de superficie: limpieza con alcohol (grupo control), silanizado, primer, arenado, arenado+silanizado o arenado+primer. Se obtuvieron especímenes cilíndricos de resina utilizando resina nanohíbrida. Los postes se cementaron a los discos de resina y se sometieron a pruebas de push-out. Los datos se analizaron con ANOVA y prueba T para comparación de promedios y la prueba Tukey HSD con un nivel de significancia del 95%. Resultados: El cemento Biscem™ presentó, en general, una mayor fuerza de adhesión a los postes al compararse con el Duolink™. Se encontró diferencia significativa entre en grupo control y los grupos de arenado+silano y arenado+primer al utilizar el cemento Duolink™. Con el cemento Biscem™ no hubo diferencias entre grupos o con el grupo control. Conclusión: Los tratamientos de superficie en los postes de resina reforzados con fibra de cuarzo parecen no tener un efecto significativo en la fuerza de adhesión a los cementos de resina evaluados en este estudio, excepto al utilizar el cemento Duolink™ realizando el arenado y además se utilizando el silano o el primer.


18. The purpose of this study was to determine the effect of different surface treatments on the bond strength between resin cements and quartz fiber-reinforced resin posts. Materials and methods: Sixty quartz fiber-reinforced resin posts (DT Light-Post™, Bisco™) were randomly divided into 12 experimental groups (n=5), according to the resin cement used (Biscem™ or Duolink™) and the surface treatment: Alcohol (control group), silanized, primer, sandblasted, sandblasted + silanized or sandblasted + primer. Cylindrical resin specimens were obtained using nanohybrid resin. The posts were cemented to the resin discs and push-out tests were conducted. Data were analyzed with ANOVA and T test for averages comparison and the Tukey HSD test with a 95% level of significance. Results: Biscem™ cement generally showed higher bond strength when compared to Duolink™ Significant differences were found between the control group and the sandblasted + silane and sandblasted + primer groups when using Duolink™cement. With Biscem™ cement, no differences between groups or with the control group were found.. Conclusion: Surface treatments on quartz fiber-reinforced resin poles seem to have no significant effect on the bond strength to resin cements, except when using Duolink™ cement with sandblasted posts and using silane or primer.

5.
Rev. mex. ing. bioméd ; 37(2): 115-122, May.-Aug. 2016. graf
Article in English | LILACS | ID: biblio-961317

ABSTRACT

Abstract: Gutta-percha with a sealer cement has been used for many years as a fill for root canal therapies, new materials and techniques have been recently developed that could increase the success rate of endodontic treatments. It is important to compare materials that are used today, with those that are coming to the market, which possess considerable advantages that may well increase the rate of successful treatments. The purpose of this research is to evaluate the adhesion properties of a new bioceramic sealer: EndoSequence® BC SealerTM using BC Points. For this, the following techniques were used: Single cone obturation and lateral condensation with AH-Plus. The results demonstrated differences between the groups of AH-Plus and BC-Sealer. On the bond strength that was applied in the different thirds of the root canal, the sealer cement BC-Sealer proved to be the best adhesion material in all thirds of the root canal being significantly more noticeable in the apical third. The two sealants are effective root canal adhesives, used properly, any of there may grant an acceptable result.


Resumen: A pesar de que la gutapercha con cemento sellador ha sido utilizada durante muchos años, últimamente se han desarrollado nuevos materiales y técnicas que podrían incrementar la tasa de éxito en los tratamientos endodónticos. Es importante comparar materiales que en la actualidad se utilizan con los nuevos que están saliendo al mercado con considerables ventajas que puedan así aumentar el índice de tratamientos exitosos. Por lo tanto, el propósito de esta investigación es evaluar las propiedades de adhesión de un nuevo sellador biocerámico EndoSequence® BC SealerTM usando BC Points. Para esto, se utilizó la técnica de obturación cono único y condensación lateral con AH- Plus. Se encontraron diferencias entre los grupos de AH-Plus y BC-Sealer. Sobre la fuerza de adhesión que se aplicó en los diferentes tercios del conducto radicular, el cemento sellador BC-Sealer demostró ser el material con mejor adhesión en todos los tercios del conducto radicular siendo significativamente más notable en tercio apical. Los dos cementos selladores son efectivos para la adhesión en los conductos radiculares, cualquiera de estos bien utilizados otorgará un resultado aceptable.

6.
Odontol. pediatr. (Lima) ; 12(1): 6-13, ene.-jun. 2013. ilus, tab
Article in Spanish | LILACS, LIPECS | ID: lil-721924

ABSTRACT

Objetivo: determinar la fuerza de adhesión de un sistema adhesivo de quinta generación en superfícies dentarias tratadas con dos agentes químico-mecánicos. Material y métodos: se trabajó con treinta molares deciduas con caries oclusal. Veinte piezas dentarias fueron asignadas aleatoriamente a los dos grupos experimentales de diez dientes cada uno y diez piezas dentarias fueron asignadas al grupo control. Se removió caries dental usando los agentes químico-mecánicos Papacarie, Carisolv y la Pieza de mano. Las piezas dentarias fueron obturadas con el sistema adhesivo de quinta generación Single Bond y resina compuesta Z250 3M. Las piezas dentales fueron colocadas en una base acrílica. Se introdujo un alambre de 3cm de largo en la base acrílica y otro en la resina compuesta de cada muestra para ser usados como dispositivos de tracción. La tracción de cada muestra para ser usados como dispositivos de tracción. La tracción de cada muestra fue medida con la ayuda del tensómetro de Hounsfield. Los datos fueron analizados estad¡sticamente con la prueba T-student. Resultados: se obtuvo como resultado que la fuerza de adhesión del agente químico-mecánico Papacarie (8,22 Mpa) represento valores más altos que Carisolv (7,76 Mpa), pero más bajo que la pieza de mano (8,71 Mpa). A diferencia del agente químico-mecánico Carisolv (7,76 Mpa) que obtuvo valores más bajos que Papacarie y la pieza de mano. Conclusiones: no se encontraron diferencias estad¡sticamente significativas en la fuerza de adhesión del sistema adhesivo de quinta generación Single Bond después del uso de los agentes químico-mecánicos Papacarie y Clarisolv.


Aim: to determine the bond strength of a fifth generation adhesive system to tooth surfaces treated with two chemical-mechanical agents. Material and methods: working with thirty occlusal carious deciduous molars. Twenty teeth were randomly assigned to the two experimental groups and ten teeth were assigned to the control group. Dental caries was removed using chemical-mechanical agents Papacarie, Clarisolv and handpiece. The teeth were sealed with adhesive system Single Bond and composite resin Z250 3M. The teeth were placed on an acrylic base to be used as traction devices. The traction of each sample was measured with the statistically analyzed using the Student T test. Results: the results obtained as the adhesion strength of the chemical-mechanical Papacarie (8.22 MPa) showed values higher than the Clarisolv (7.76 MPa), but lower than the handpiece (8.71 MPa). Unlike chemical-mechenical Carisolv (7.76 Mpa) obtained lower values than Papacarie hand handpiece. Conclusions: we found no estadistically significant difference in the bond strength of chemical-mechanical agents Papacarie and Clarisolv.


Subject(s)
Dental Caries , Dental Cements , Dental Bonding
SELECTION OF CITATIONS
SEARCH DETAIL