Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 28-32, 2022.
Article in Chinese | WPRIM | ID: wpr-934211

ABSTRACT

Objective:To analysis the mid-stage prognosis of transapical aortic valve implantation(TA-TAVI) using J-Valve? system for the treatment of high-risk aortic regurgitation(AR) patients.Methods:Data of 25 patients with aortic regurgitation who had underwent transapical aortic valve implantation using J-Valve? system were collected in the Second Affiliated Hospital of Medical College of ZheJiang University from September 2016 to June 2020 . Analysis and summarize their postoperative all-cause mortality, the incidence of adverse events and the improvement in cardiac function.Results:There were 25 patients, including 19 males, the age rage from 59-83 years, the average age was(72.3±27.11) years. The levels of aortic regurgitation was evaluated by transthoracic echocardiography preoperatively, showed that severe AR accounted for 88%. The New York Heart Association(NYHA) of grade 3 or above was 92%. The most common comorbidity was hypertension, accounted for 68%. Coronary heart disease and history of cardiac surgery was 5 and 3 relatively in this study. The Society of Thoracic Surgeons score before surgery was 1.511%-27.674%, the average of STS score was 4.27(2.914-6.033)%. Successful J-Valve implantation was obtained in all 25 cases, no conversion to thoracotomy. After surgery, 2 patients required permanent pacemaker implantation, 1 patient needed continuous renal replacement therapy(CRRT) due to acute kidney injury, 1 occurred moderate or above paravalvular leak. The results showed good therapeutic effects in early-stage, low incidences of adverse events. The continued improvement of cardiac function and ventricular reverse remodeling could be observed in mid-stage.Conclusion:In this study, we can summarize that high-risk patients with aortic regurgitation treated with transapical aortic valve implantation using J-Valve? system can acquire great perioperative safety and mid-stage prognosis.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 737-743, 2019.
Article in Chinese | WPRIM | ID: wpr-750294

ABSTRACT

@#Objective     To investigate the early safety and efficacy of transapical transcatheter aortic valve implantation (TAVI) for high-risk elderly patients with pure aortic valve insufficiency. Methods     A prospective multicenter clinical study of domestic J-valveTM TAVI for high-risk native non-calcified aortic valve insufficiency was conducted from April 2014 to May 2018, and the early postoperative results were analyzed. A total of 82 patients were enrolled, including 62 patients from West China Hospital, Sichuan University, 16 patients from Zhongshan Hospital, Fudan University, and 4 patients from Beijing Fuwai Hospital, National Center for Cardiovascular Diseases. There were 55 males and 27 females. The age was 61-90 (73.8±6.3) years. The logistic EuroSCORE was 10.0%-44.4% (17.5%±8.1%). All patients underwent TAVI using J-ValveTM system. Clinical evaluation and echocardiography were performed preoperatively and 1 month postoperatively. Multislice spiral CT was reviewed before discharge. Results     Three patients were transferred to thoracotomy for cardiopulmonary bypass operation, and 1 patient had decreased cardiac function due to leakage of the valve 1 week after surgery. The overall technical and procedural success rate was 95.1% and 93.9%, respectively. During hospitalization, 1 patient died of moderate pericyclosis complicated with multiple organ failure, and 1 patient died of pulmonary infection. Six (7.6%) patients received pacemaker implantation due to new onset Ⅲ° atrioventricular block. Echocardiographic follow-up showed paravalvular leak was observed in the few of patients, mild paravalvular leak was in 13 patients on the 30th day. Two patients showed moderate paravalvular leak. Left ventricular end-diastolic volume decreased from 197.7±66.8 mL (pre-TAVI) to 147.2±53.3 mL (30-day post-TAVI) (P<0.05). Mean pressure gradient was 9.5±4.1 mm Hg (30-day post-TAVI). Conclusion     This multicenter study demonstrates that TAVI with the J-Valve system for the treatment of pure aortic regurgitation is associated with sustained clinical and functional cardiovascular benefits in high-risk patients with symptomatic aortic regurgitation early-term follow-up. Our results further support that TAVI with the specific designed J-Valve system is an acceptable alternative therapy for high-risk patients with pure AR. Our result demonstrates good early-term durability and preserved hemodynamic function. The procedure appears to offer an adequate and lasting resolution for selected patients with pure aortic regurgitation.

SELECTION OF CITATIONS
SEARCH DETAIL