Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.553
Filter
1.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 321-329, 2024.
Article in Chinese | WPRIM | ID: wpr-1016554

ABSTRACT

@#The standardized workflow of computer-aided static guided implant surgery includes preoperative examination, data acquisition, guide design, guide fabrication and surgery. Errors may occur at each step, leading to irreversible cumulative effects and thus impacting the accuracy of implant placement. However, clinicians tend to focus on factors causing errors in surgical operations, ignoring the possibility of irreversible errors in nonstandard guided surgery. Based on the clinical practice of domestic experts and research progress at home and abroad, this paper summarizes the sources of errors in guided implant surgery from the perspectives of preoperative inspection, data collection, guide designing and manufacturing and describes strategies to resolve errors so as to gain expert consensus. Consensus recommendation: 1. Preoperative considerations: the appropriate implant guide type should be selected according to the patient's oral condition before surgery, and a retaining screw-assisted support guide should be selected if necessary. 2. Data acquisition should be standardized as much as possible, including beam CT and extraoral scanning. CBCT performed with the patient’s head fixed and with a small field of view is recommended. For patients with metal prostheses inside the mouth, a registration marker guide should be used, and the ambient temperature and light of the external oral scanner should be reasonably controlled. 3. Optimization of computer-aided design: it is recommended to select a handle-guided planting system and a closed metal sleeve and to register images by overlapping markers. Properly designing the retaining screws, extending the support structure of the guide plate and increasing the length of the guide section are methods to feasibly reduce the incidence of surgical errors. 4. Improving computer-aided production: it is also crucial to set the best printing parameters according to different printing technologies and to choose the most appropriate postprocessing procedures.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 329-332, 2024.
Article in Chinese | WPRIM | ID: wpr-1016377

ABSTRACT

@#The sternum is the pivotal component of the thoracic cavity. It is connected with the clavicle and ribs on the upper part and both sides respectively, and plays an important role in protecting the stability of the chest wall. Sternal resection usually results in a large segmental chest wall defect that causes the chest wall to float and requires sternal reconstruction. This paper reports a 62 years male patient with thymic squamous cell carcinoma with sternal metastasis, who underwent thymotomy, sternal tumor resection and autologous lilum graft combined with sternal reconstruction by titanium plate after relevant examination was completed and surgical contraindications were eliminated. The patient was followed up for 6 months, the respiratory and motor functions were normal and the thoracic appearance was good.

3.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 280-286, 2024.
Article in Chinese | WPRIM | ID: wpr-1013089

ABSTRACT

Objective@#Based on 3D printing technology, explore the precision of a perforator vessel location guide plate for fibular musculocutaneous flaps before the transplantation of fibular osteocutaneous flaps and evaluate its application effects.@*Methods@#This study was reviewed and approved by the ethics committee, and informed consent was obtained from the patients. From May 2019 to October 2022, 14 patients with jaw defects who needed to undergo fibular perforator flap transplantation at the First Affiliated Hospital of Xinjiang Medical University were selected. For the seven patients in the guide plate group, CTA was combined with Mimics software to reconstruct both lower limbs, and the perforator vessel positioning guide for locating perforator vessels was designed; the two ends of the guide plate were designed as fixed ends, with the upper end fixed to the knee joint and the lower end fixed to the ankle joint, and the guide plate was fabricated by a 3D printer. For the seven patients in the control group, a conventional handheld Doppler probe was used for perforator vessel location. The average operation time, bleeding volume, recovery time, deviation of perforator vessel location, postoperative flap-related complications, postoperative donor site shape satisfaction, and lower extremity functional scale (LEFS) score were recorded. SPSS 25.0 software was used for statistical analysis.@*Results@#The average operation time, bleeding volume, recovery time, deviation of perforator vessel location and postoperative donor site shape satisfaction were significantly better in the guide plate group than in the control group (P<0.05); moreover, the differences in postoperative flap-related complications and LEFS scores were not statistically significant (P>0.05).@*Conclusion@#Based on 3D printing technology, fibular musculocutaneous flap perforator vessels can be more accurately located using a guide plate and the knee and ankle as fixed points, and this method can effectively stabilize the guide position, prevent soft tissue offset, and improve positioning accuracy and thus deserves to be generalized.

4.
Journal of Sun Yat-sen University(Medical Sciences) ; (6): 108-113, 2024.
Article in Chinese | WPRIM | ID: wpr-1007281

ABSTRACT

ObjectivesTo compare the clinical efficacy and complications of anatomic locking titanium plate (hereinafter referred to as “titanium plate screw”) and intramedullary nail in the treatment of distal tibial fractures.Methods From September 2019 to September 2021, 32 patients diagnosed with AO-A fracture of distal tibia at Sun Yat-sen Memorial Hospital of Sun Yat-sen University were included in this study. Of these, 15 cases were treated with titanium plate screws and 17 cases were treated with intramedullary nails. General surgical indexes, fracture healing time and postoperative operation were compared between the two groups.ResultsAll patients were followed up for 10 to 20 months, with an average of 12 months. The operative time and intraoperative fluoroscopy times of intramedullary nail group were longer than those of titanium plate screw group, but the preoperative waiting time and hospitalization days was less or were fewer than those of titanium plate screw group, the difference was statistically significant (P < 0.05). There was no significant difference in fracture healing time between the two groups (P> 0.05). At 6 weeks after operation, VAS scores in both groups were lower than those before operation, with statistically significant difference (P<0.05). There was no significant difference in VAS scores between the intramedullary nail group and the titanium plate screw group (P> 0.05). AOFAS scores 6 months after surgery, ankle joint motion and complication rate 1 year after surgery in intramedullary screw group were better than those in titanium plate screw group, and the differences were statistically significant (P< 0.05). There was no significant difference in AOFAS scores between the two groups at 1 year after operation (P> 0.05).ConclusionTitanium plate screw and intramedullary nail are both effective methods for the treatment of distal tibial AO-A fracture, and there is no significant difference in long-term clinical efficacy. Intramedullary nail has fewer soft tissue complications, less impact on ankle motion, faster recovery and higher safety, while titanium plate screw has a higher probability of postoperative soft tissue infection. We suggest that in clinical work, preoperative evaluation of patients should be done well. Under the premise of grasping the indications, intramedullary nail has fewer complications and certain advantages.

5.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 57-63, 2024.
Article in Chinese | WPRIM | ID: wpr-1003446

ABSTRACT

Objective@#To investigate the effect of the socket-shield technique (SST) concurrent with immediate implant placement and provisionalization (IIPP) in the aesthetic restoration of anterior teeth.@*Methods@#A case of maxillary anterior tooth stumps with a thin labial bone wall was treated with SST for preservation of labial soft and hard tissue fullness, combined with an immediate implant placement and immediate provisional crown for restoring the shape of the tooth and gingival molding@*Results@#Immediate implant placement and provisionalization restored the morphology and function of the affected tooth in the shortest possible time. The patient's labial soft and hard tissue contours in the affected tooth area were well preserved in the 18-month follow-up after the application of the SST, which presented a better aesthetic result. The literature review indicates that the indications for SST are unrestorable maxillary anterior teeth, whose dental, periodontal and periapical tissues are healthy and intact. In the esthetic zone, root shielding is effective in maintaining the soft and hard tissue contour on the labial side of the implant. However, there is no consensus on the technical details of SST, such as the ideal coronal height and thickness of the shield, and the management of the gap between the shield and the implant. Thus, more clinical studies and histologic evidence are needed to provide a reference for clinical decision-making. In addition, digital technology can improve the accuracy of implant placement and shield preparation.@*Conclusion@#The correct application of SST combined with IIPP in the esthetic zone can ensure esthetic results. However, more high-quality evidence-based medical evidence is needed for its long-term efficacy, and indications should be strictly controlled during clinical application.

6.
China Journal of Orthopaedics and Traumatology ; (12): 57-60, 2024.
Article in Chinese | WPRIM | ID: wpr-1009223

ABSTRACT

OBJECTIVE@#To compare the biomechanical stability of three cross-bridge headless compression screws and locking plates in the fixation of Mason type Ⅲ radial head fractures by finite element method.@*METHODS@#Using reverse modeling technology, the radial CT data and internal fixation data of a healthy 25-year-old male were imported into the relevant software. Three-dimensional finite element model of 3 cross-bridge headless compression screws and locking plates for MasonⅢ radial head fractures were established, and the radial head was loaded with 100 N axial loading. The maximum displacement, maximum Von Mises stress and stress distribution of the two groups were compared.@*RESULTS@#The maximum displacements of the three cross-bridge screws group and locking plate group were 0.069 mm and 0.087 mm respectively, and the Von Mises stress peaks were 18.59 MPa and 31.85 MPa respectively. The stress distribution of the three screws group was more uniform.@*CONCLUSION@#Both internal fixation methods can provide good fixation effect. CoMPared with the locking plate fixation method, the 3 cross-bridge headless compression screws fixation is more stable and the stress distribution is more uniform.


Subject(s)
Male , Humans , Adult , Finite Element Analysis , Radial Head and Neck Fractures , Bone Screws , Biomechanical Phenomena , Radius Fractures/surgery , Fracture Fixation, Internal/methods , Bone Plates , Fractures, Comminuted
7.
Acta ortop. bras ; 32(1): e277177, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1550005

ABSTRACT

ABSTRACT Introduction: Legg-Calvé-Perthes disease (LCPD) is the idiopathic osteonecrosis of the capital femoral epiphysis in children. It is a self-healing condition, and the morphology of the hip may vary according to the severity of the disease, among several other factors. The treatment focuses on attempts to prevent femoral head collapse, obtain functional hip motion recovery, and reduce pain. Osteochondritis Dissecans (OCD) of the femoral head has been reported in 2% to 7% of patients diagnosed with healed LCPD. Although OCD may remain asymptomatic, the osteochondral fragment has the potential to become unstable, evolving into symptoms of pain, locking, catching, and snapping. Case report: We present a case report of a ten-year-old boy with an OCD lesion following LCPD who underwent effective osteochondral fixation through the surgical hip dislocation approach. The patient evolved to excellent functional recovery at 1 year post-operatively. Discussion: The surgical hip dislocation approach allows anatomical fixation of the OCD fragment, as well as improvement of hip biomechanics, decreasing pain, improving range of motion and joint congruency, and preserving the native articular cartilage. It also gives the surgeon the opportunity to assess hip stability, femoroacetabular impingement and labral tears, allowing a wide variety of options for the treatment of the healed LCPD. Level of Evidence IV; Type of study Case Report.


RESUMO Introdução: A Doença de Legg-Calvé-Perthes (DLCP) é a osteonecrose idiopática da epífise femoral proximal em crianças. É uma condição auto resolutiva, porém a morfologia final do quadril pode variar de acordo com a gravidade da doença. O tratamento concentra-se na tentativa de prevenir o colapso da cabeça femoral, obtendo recuperação funcional do movimento do quadril e redução da dor. A osteocondrite dissecante (OCD) da cabeça femoral foi relatada em 2% a 7% dos pacientes diagnosticados com DLCP já curada. Embora a OCD possa permanecer assintomática, o fragmento osteocondral tem potencial para se tornar instável, evoluindo para sintomas de dor, bloqueio, impacto e estalido. Relato de caso: Apresentamos o relato de caso de um menino de 10 anos com OCD da cabeça femoral após DLCP, submetido à fixação osteocondral do fragmento por meio da abordagem cirúrgica de luxação do quadril. O paciente evoluiu com excelente recuperação funcional 1 ano após a cirurgia. Discussão: A abordagem cirúrgica da luxação do quadril permite a fixação anatômica do fragmento da OCD, bem como a melhora da biomecânica do quadril, diminuindo a dor, melhorando a amplitude de movimento e a congruência articular e preservando a cartilagem articular nativa. Também dá ao cirurgião a oportunidade de avaliar a estabilidade do quadril, impacto femoroacetabular e lesões labrais, permitindo uma ampla variedade de opções para o tratamento das sequelas da DLCP. Nível de evidência IV; tipo de estudo Relato de Casos.

8.
Int. j. morphol ; 41(5): 1508-1512, oct. 2023. ilus, tab
Article in English | LILACS | ID: biblio-1521014

ABSTRACT

SUMMARY: Distal radius fractures are the most common fractures of the upper limb. The most commonly used method in the repair of these fractures is volar locking plates. Recently, the frequency of removal of volar locking plates after surgery has increased. There are many factors in its reduction. Anatomically, incompatibility of the distal end of the radius with volar locking plates is one of them. In previous studies, different volar cortical angle (VCA) values were found in other races. For this reason, this study aimed to determine the mean values by making VCA measurements of the Anatolian population. The study was designed retrospectively. In the study, measurements were made on computed tomography (CT) images of the distal end of the radius of 53 men and 28 women. Radial width, intermediate volar angle, and radial volar angle were measured in the images. On average, the radius width was 23.35±1.96 mm, and the intermediate volar angle was 26.02±.3.83°, radial volar angle was 24±3.07°. Radial width, intermediate volar angle, and radial volar angle differed significantly by gender (p<0.001). A significant correlation was found between radius width, intermediate volar angle, and radial volar angle values (p<0.001). It has been determined that the Anatolian population has a different VCA value than the European, Asian, and other populations. When using volar locking plates in distal radius fracture surgery, volar locking plates should be selected by considering the average values of the races.


Las fracturas del radio distal son las fracturas más comunes del miembro superior. El método más utilizado en la reparación de estas fracturas son las placas de bloqueo volar. Recientemente, ha aumentado la frecuencia de extracción de placas de bloqueo volar después de la cirugía. Existen muchos factores en su reducción y anatómicamente, la incompatibilidad de la extremidad distal del radio con las placas de bloqueo volar es una de ellas. En estudios anteriores, se encontraron diferentes valores del ángulo cortical volar (VCA) en otras grupos. Por esta razón, este estudio tuvo como objetivo determinar los valores medios, realizando mediciones de VCA de la población de Anatolia. El estudio fue diseñado de manera retrospectiva. En el estudio, se realizaron mediciones en imágenes de tomografía computarizada (TC) de la extremidad distal del radio de 53 hombres y 28 mujeres. En las imágenes se midieron el ancho radial, el ángulo volar intermedio y el ángulo volar radial. En promedio, el ancho del radio fue de 23,35 ± 1,96 mm, el ángulo volar intermedio fue de 26,02 ± 3,83° y el ángulo volar radial fue de 24 ± 3,07°. El ancho radial, el ángulo volar intermedio y el ángulo volar radial difirieron significativamente según el sexo (p<0,001). Se encontró una correlación significativa entre los valores del ancho del radio, el ángulo volar intermedio y el ángulo volar radial (p<0,001). Se ha determinado que la población de Anatolia tiene un valor de VCA diferente al de las poblaciones europeas, asiáticas y otras. Cuando se utilizan placas de bloqueo volar en cirugía de fractura de la extremidad distal del radio, las placas deben seleccionarse considerando los valores promedio de los individuos de diferentes grupos.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Radius/diagnostic imaging , Wrist/diagnostic imaging , Radius/anatomy & histology , Turkey , Wrist/anatomy & histology , Tomography, X-Ray Computed , Retrospective Studies
9.
Int. j. morphol ; 41(4): 1135-1145, ago. 2023. ilus, tab
Article in English | LILACS | ID: biblio-1514341

ABSTRACT

SUMMARY: The human soleus muscle has attracted attention in the fields of sport science, rehabilitation medicine, etc. for improving exercise performance in training, preventing injuries, and rehabilitation. The sagittal tendon plate of the soleus muscle is particularly important in rehabilitation. Few studies, however, have evaluated the shape of the sagittal tendon plate in the human soleus muscle in detail and attempted to classify its variations based on its morphology. In this study, we conducted a detailed analysis of the morphology of the sagittal tendon plates in soleus muscle specimens from Japanese cadavers and constructed a morphology-based classification system and evaluated their frequencies of occurrence. First, the specimens were divided into those with a sagittal tendon plate that was visible on the anterior surface (pennate muscle group) and those without (non-pennate muscle group). Next, based on the "number" and "breadth" of the sagittal tendon plates, the pennate muscle group specimens were further classified into four classes: Class I (one tendon, thin), Class II (one tendon, slightly broad), Class III (one tendon, very broad), and Class IV (two tendons, thin). Subsequently, the specimens were further divided into three types based on the position where the sagittal tendon plate joined the Achilles tendon: median tendon type, lateral tendon type, and medial tendon type (a total 13 divisions). When 458 Japanese soleus muscle specimens were classified into these divisions, the occurrence frequencies of Class I-IV were 80.57 %, 4.59 %, 5.46 %, and 1.09 %, respectively. In Class I, the median tendon type was more frequent than the lateral and medial tendon types, accounting for 48.47 % overall. The classification types of the sagittal tendon plate and their respective occurrence frequencies shown in this study are expected to serve as fundamental data in implementing rehabilitation of soleus muscle.


El músculo sóleo humano ha atraído la atención de la ciencia del deporte, la medicina de rehabilitación, etc. para mejorar el rendimiento del ejercicio en el entrenamiento, prevenir las lesiones y rehabilitación. La lámina tendinosa sagital del músculo sóleo es particularmente importante en la rehabilitación. Sin embargo, pocos estudios han evaluado en detalle la forma de la placa lámina sagital en el músculo sóleo humano y han intentado clasificar sus variaciones en función de su morfología. Realizamos un análisis detallado de la morfología de las láminas de los tendones sagitales en muestras de músculo sóleo de cadáveres japoneses y construimos un sistema de clasificación basado en la morfología y, además, evaluamos su frecuencia de aparición. Los especímenes se dividieron en aquellos con una lámina de tendón sagital que era visible en la superficie anterior (grupo muscular pennado) y aquellos sin (grupo muscular no pennado). A continuación, según el "número" y el "ancho" de las láminas de los tendones sagitales, las muestras del grupo de músculos pennados se clasificaron en cuatro clases: Clase I (un tendón, delgado), Clase II (un tendón, ligeramente ancho), Clase III (un tendón, muy ancho) y Clase IV (dos tendones delgados). Posteriormente, las muestras se dividieron en tres tipos, según la posición donde la lámina del tendón sagital se unía al tendón calcáneo: tipo de tendón mediano, tipo de tendón lateral y tipo de tendón medial (un total de 13 divisiones). En estas divisiones se clasificaron 458 especímenes de músculo sóleo de indiviuos japoneses, las frecuencias de ocurrencia de Clase I-IV fueron 80,57 %, 4,59 %, 5,46 % y 1,09 %, respectivamente. En la Clase I, el tipo de tendón mediano era más frecuente que los tipos de tendón lateral y medial, representando el 48,47 % del total. Se espera que los tipos de clasificación de la lámina del tendón sagital y sus respectivas frecuencias de aparición, que se reportan en este estudio, sirvan como datos fundamentales para implementar la rehabilitación del músculo sóleo.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Tendons/anatomy & histology , Muscle, Skeletal/anatomy & histology , Cadaver , Japan
10.
Kinesiologia ; 42(2): 127-131, 20230615.
Article in Spanish, English | LILACS-Express | LILACS | ID: biblio-1552472

ABSTRACT

Objetivo. Analizar el rendimiento biomecánico de las placas de tibia proximal utilizadas en fracturas de platillos tibiales evaluado a través de modelos de elementos finitos. Métodos. Se realizará una búsqueda exhaustiva en PubMed/Medline, Embase, Lilacs, Web of Science y Google Scholar. No se utilizará ninguna restricción de idioma o estado de publicación. Dos revisores examinarán de forma independiente los posibles artículos elegibles, de acuerdo con los criterios de selección predefinidos. Se incluirán los estudios que evalúen el rendimiento de los platillos tibiales proximales utilizados en las fracturas del platillo tibial evaluadas mediante el análisis de elementos finitos. La extracción de datos sobre las características del estudio, los métodos, los resultados y la evaluación del riesgo de sesgo se realizará mediante un formulario estandarizado. Considerando el diseño de estudio no se requiere evaluación por comité de ética. Los resultados de esta revisión se difundirán a través de la publicación en revistas revisadas por pares, redes sociales y congresos de la especialidad. Se espera que los resultados de esta revisión permitan optimizar los resultados del manejo quirúrgico de las fracturas de platillos tibiales. Número de registro PROSPERO: CRD42023396015.


Objetive. To analyze the biomechanical performance of proximal tibial plates used in tibial plate fractures evaluated through finite element modeling. Methods. A comprehensive search will be conducted in PubMed/Medline, Embase, Lilacs, Web of Science, and Google Scholar. No language or publication status restrictions will be used. Two reviewers will independently review potential eligible articles according to predefined selection criteria. Studies evaluating the performance of proximal tibial splints used in tibial splint fractures assessed by finite element analysis will be included. Data extraction on study characteristics, methods, results, and risk of bias assessment will be performed using a standardized form. Considering the study design, evaluation by an ethics committee is not required. The results of this review will be disseminated through publication in peer-reviewed journals, social networks and specialty congresses. It is expected that the results of this review will allow optimizing the results of the surgical management of tibial plate fractures. PROSPERO registration number: CRD42023396015.

11.
Article | IMSEAR | ID: sea-221474

ABSTRACT

Background- Fractures of distal femur are one of the most prevalent fractures encountered in high-velocity trauma which are associated with high morbidity and mortality if not managed well. The isolated fracture can itself lead to complications such as Acute Respiratory Distress and pulmonary embolism. This neccesitaties early stabilisation of the fractures. Open reduction and internal fixation (ORIF) with locking compression plate is the treatment of choice for closed fractures of the distal femur. Distal femur anatomic contoured locking compression plate (LCP) has shown to give one of the best results regarding recovery, fracture union, return to work and the functional outcome. We present our experience of management of distal femur fracture at our centre. Study Material and Methodsdone on 36 patients, (NEER'S Classification) age range of 18 to 70 years (irrespective of their sex), were subjected to fixation by locking compression plate after obtaining thorough written informed consent. The observational study was carried at our institute between June 2021 to June 2022 Patients of both gender who were skeletally mature are taken into the study. In 61.5% of patients up to 50 years old and in Results40% of patients older than 50 years, the functional evaluation of LCP using Neers criteria was excellent. There was no statistically significant (p>0.05) difference in patients' functional status according to their age group who had distal femur fractures, which were stabilise by LCP. For supracondylar femur fractures, locking compression plates is a safe technique that has a good functional outcome, early clinical and radiographic union, and few complications.

12.
Rev. bras. ortop ; 58(2): 191-198, Mar.-Apr. 2023. graf
Article in English | LILACS | ID: biblio-1449794

ABSTRACT

Abstract Historically, surgeries on the immature skeleton were reserved for open or articular fractures. In recent years, the improvement in the quality and safety of anesthesia, new imaging equipment, implants designed especially for pediatric fractures, associated with the possibility of shorter hospitalization time and rapid return to social life has demonstrated a new tendency to evaluate and treat fractures in children. The purpose of this update article is to answer the following questions: (1) Are we really turning more surgical in addressing fractures in children? (2) If this is true, is this surgical conduct based on scientific evidence? In fact, in recent decades, the medical literature demonstrates articles that support better evolution of fractures in children with surgical treatment. In the upper limbs, this is very evident in the systematization of the reduction and percutaneous fixation of supracondylar fractures of the humerus and fractures of the forearm bones. In the lower limbs, the same occurs with diaphyseal fractures of the femur and tibia. However, there are gaps in the literature. The available published studies show low scientific evidence. Thus, it can be inferred that, even though the surgical approach is more present, the treatment of pediatric fractures should always be individualized and conducted according to the knowledge and experience of the professional physician, taking into account the presence of technological resources available for the care of the small patient. All possibilities, non-surgical and/or surgical, should be included, always instituting actions based on science and in agreement with the family's wishes.


Resumo Historicamente, as cirurgias no esqueleto imaturo eram reservadas às fraturas expostas ou articulares. Nos últimos anos, a melhora na qualidade e segurança das anestesias, novos equipamentos de imagem, implantes desenhados especialmente para fraturas pediátricas, associados à possibilidade de menor tempo de hospitalização e rápido retorno ao convívio social vêm demonstrando uma nova tendência de avaliar e tratar fraturas na criança. O objetivo deste artigo de atualização é responder às seguintes questões: (1) estamos realmente ficando mais cirúrgicos na abordagem das fraturas em crianças? (2) Caso isto seja verdadeiro, esta conduta cirúrgica está baseada em evidências científicas? De fato, nas últimas décadas, a literatura médica demonstra artigos que suportam melhor evolução das fraturas na criança com o tratamento cirúrgico. Nos membros superiores, isto fica muito evidente na sistematização da redução e fixação percutânea das fraturas supracondilianas do úmero e das fraturas de ossos do antebraço. Nos membros inferiores, o mesmo ocorre com fraturas diafisárias do fêmur e tíbia. No entanto, há lacunas na literatura. Os estudos publicados são geralmente com baixa evidência científica. Assim, pode-se deduzir que, mesmo sendo a abordagem cirúrgica mais presente, o tratamento de fraturas pediátricas deve ser sempre individualizado e conduzido de acordo com o conhecimento e experiência do médico profissional, levando em conta a presença de recursos tecnológicos disponíveis para o atendimento do pequeno paciente. Deve-se incluir todas as possibilidades, não cirúrgicas e/ou cirúrgicas, sempre instituindo ações baseadas na ciência e em concordância com os anseios da família.


Subject(s)
Humans , Child, Preschool , Child , Fractures, Bone , Salter-Harris Fractures , Fracture Fixation, Internal , Growth Plate/surgery
13.
Article | IMSEAR | ID: sea-220101

ABSTRACT

Reconstruction plates with or without bone grafts are used to restore mandibular continuity, form and function following segmental resection of mandible. Fracture of reconstruction plate is observed in 2.9 % to 10% of cases reported in the literature excluding other complications. In this case, we report the fracture of stainless steel reconstruction plate used without bone graft and its management using locking reconstruction plate with non vascularised iliac crest graft following removal of the fractured plate. Review of literature describing incidence, pattern and causes of reconstruction plate fracture and its management is discussed.

14.
Article | IMSEAR | ID: sea-217950

ABSTRACT

Background: Pain is a common stimulus that induces anxiety in both Animals and human beings. Aim and Objective: We have undertaken this study to evaluate the induction of anxiety in Wistar rats using hot plate method. Materials and Methods: 24 Wistar rats of either gender were used. Elevated plus maze (EPM) and light and dark arena (LDA) were used to evaluate the anxiety and hot plate analgesiometer was used to induce anxiety. After baseline reading from EPM and LDA, the Wistar rats were exposed to the hot plate and then evaluated for the induction of the anxiety behavior. Results: After exposing to the hot plate, the ratio of time spent in the open arms to the time spent on the closed arms was decreased from 0.027 to 0.010 and also the ratio of time spent on the light chamber to the time spent on the dark chamber was decreased from 0.093 to 0.012. Hot plate method has shown statistical significant induction of anxiety as evaluated by EPM and also LDA. Conclusion: Hot plate method is a good intervention to induce anxiety in Wistar rats. Instead of injecting drugs that causes anxiety to explore the anxiolytic effects of the drugs the hot plate analgesiometer method is a good alternative.

15.
Braz. dent. j ; 34(1): 39-44, Jan.-Feb. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1420574

ABSTRACT

Abstract The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Resumo Objetivou-se avaliar a influência do uso excessivo de uma placa de fósforo fotoestimulável (PSP) na densidade, ruído e contraste das radiografias. Foram adquiridas radiografias de um bloco de acrílico com uma PSP do sistema intraoral Express para avaliar a densidade e o ruído da imagem. Inicialmente, cinco imagens foram obtidas e exportadas (primeiro grupo). Após 400 exposições aos raios X e escaneamentos, outras cinco imagens foram obtidas e exportadas (segundo grupo). O mesmo procedimento foi feito após 800 (terceiro grupo), 1200 (quarto grupo), 1600 (quinto grupo) e 2000 aquisições (sexto grupo), resultando em 30 imagens a serem avaliadas. A média e o desvio padrão dos valores de cinza foram calculados para as imagens usando o software ImageJ. Para análise de contraste, foram adquiridas radiografias de uma escala de alumínio com uma nova PSP seguindo os mesmos intervalos de aquisição. A porcentagem de variação do contraste foi calculada. Outras duas PSP sem uso prévio foram utilizadas para avaliar a reprodutibilidade dos métodos. A comparação dos resultados entre os grupos de aquisição foi realizada pela Análise de Variância one-way (α=0,05). O Coeficiente de Correlação Intraclasse (ICC) avaliou a reprodutibilidade dos receptores. O ruído da imagem não diferiu entre os grupos (p>0,05). Houve um leve aumento na densidade após 400 aquisições e uma pequena diferença no contraste para todos os grupos de aquisição sem padrão de aumento ou diminuição (p<0,05). O ICC mostrou excelente confiabilidade para os métodos. Portanto, o uso excessivo da PSP afetou levemente a densidade e o contraste radiográfico.

16.
Braz. j. biol ; 83: e245585, 2023. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1339413

ABSTRACT

Abstract Many soil microorganisms' i.e., bacteria and fungi produce secondary metabolites called antibiotics. These are used for the treatment of some of the bacterial, fungal and protozoal diseases of humans. There is a need for isolation of a broad spectrum of antibiotics from microorganisms due to the emergence of antibiotic resistance. In the present study two antibiotic producing bacteria Klebsiella pneumoniae and Bacillus cereus were isolated from pharmaceutical and poultry feed industry of Hattar, Haripur Pakistan. Total 10 waste samples were collected from different industries (Marble, Ghee, Soap, Mineral, Steel, Poultry Feed, Pharmaceutical, Qarshi, Cosmetic and Glass). Thirty-three bacterial strains were isolated from industrial wastes of these ten different industries. Fourteen out of thirty-three bacterial strains exhibited antimicrobial activities against at least one of the test microbes considered in this study including Escherchia coli, Staphylococcus aureus and Salmonella typhi. The bacteria were isolated by standard serial dilution spread plate technique. Morphological characterization of the isolates was done by Gram staining. Nine bacterial isolates out of fourteen were initially identified as B. cereus and five as K. pneumoniae through biochemical characterization. The antibacterial activities were tested by well diffusion method. Maximum number of antibiotic producing bacteria were isolated from pharmaceutical and poultry feed industry based on the results of primary screening, the most potential isolates S9, S19, S20, S22 and S23 were selected for secondary screening. The maximum activity against E. coli and S. aureus was recorded by bacterial isolate S19 i.e zones of inhibition of 6.5mm and 9mm while S20 showed 7.5mm and 6mm zones respectively. Molecular identification was carried out on the basis of 16S rRNA sequence analysis. Finally, the isolates were identified as B. cereus accession number LC538271and K. pneumoniae accession number MT078679. Analysis of bacterial extract S20 through GC-MS indicated the presence of 8 compounds of diverse nature and structure. Present study suggests that wastes of pharmaceutical and poultry feed industry may have antibiotic producing bacteria. These bacteria could be utilized for the production of antibiotics. B. cereus and K. pneumoniae isolated from wastes of poultry feed and pharmaceutical industries have the potential to produce antibiotics and could be used to control the microbial growth.


Resumo Muitos microrganismos do solo, ou seja, bactérias e fungos produzem metabólitos secundários chamados antibióticos. Eles são usados ​​para tratamento de algumas doenças bacterianas, fúngicas e protozoárias em humanos. Há necessidade de isolamento de um amplo espectro de antibióticos de microrganismos devido ao surgimento de resistência aos antibióticos. No presente estudo, duas bactérias produtoras de antibióticos, Klebsiella pneumoniae e Bacillus cereus, foram isoladas da indústria farmacêutica e de ração avícola de Hattar, Haripur, Paquistão. Um total de 10 amostras de resíduos foi coletado de diferentes indústrias (mármore, ghee, sabão, mineral, aço, ração para aves, farmacêutica, Qarshi, cosmética e vidro). Trinta e três cepas bacterianas foram isoladas de resíduos industriais dessas dez diferentes indústrias. Quatorze das 33 cepas bacterianas exibiram atividades antimicrobianas contra pelo menos um dos micróbios de teste considerados neste estudo, incluindo Escherchia coli, Staphylococcus aureus e Salmonella typhi. As bactérias foram isoladas pela técnica de placa de diluição em série padrão. A caracterização morfológica dos isolados foi feita por coloração de gram. Nove isolados bacterianos de 14 foram inicialmente identificados como B. cereus e cinco como K. pneumoniae por meio de caracterização bioquímica. As atividades antibacterianas foram testadas pelo método de difusão em poço. O número máximo de bactérias produtoras de antibióticos foi isolado da indústria farmacêutica e de ração avícola com base nos resultados da triagem primária, os isolados mais potenciais S9, S19, S20, S22 e S23 foram selecionados para a triagem secundária. A atividade máxima contra E. coli e S. aureus foi registrada pelo isolado bacteriano S19, ou seja, zonas de inibição de 6,5 mm e 9 mm, enquanto S20 mostrou zonas de 7,5 mm e 6 mm, respectivamente. A identificação molecular foi realizada com base na análise da sequência 16S rRNA. Finalmente, os isolados foram identificados como B. cereus número de acesso LC538271 e K. pneumoniae número de acesso MT078679. A análise do extrato bacteriano S20 por meio de GC-MS indicou a presença de oito compostos de natureza e estrutura diversas. O presente estudo sugere que resíduos da indústria farmacêutica e de ração para aves podem conter bactérias produtoras de antibióticos. Essas bactérias podem ser utilizadas para a produção de antibióticos B. cereus e K. pneumoniae isolados de resíduos de rações de aves e indústrias farmacêuticas têm potencial para produzir antibióticos e podem ser usados ​​para controlar o crescimento microbiano.


Subject(s)
Humans , Staphylococcus aureus , Industrial Waste , RNA, Ribosomal, 16S , Plant Extracts , Microbial Sensitivity Tests , Escherichia coli , Gas Chromatography-Mass Spectrometry , Anti-Bacterial Agents/pharmacology
17.
China Journal of Orthopaedics and Traumatology ; (12): 255-261, 2023.
Article in Chinese | WPRIM | ID: wpr-970858

ABSTRACT

OBJECTIVE@#To investigate the biomechanical characteristics of different internal fixations for Pauwels type Ⅲ femoral neck fracture with defect, and provide reference for the treatment of femoral neck fracture.@*METHODS@#Three-dimensional (3D) finite element models of femoral neck fractures were established based on CT images, including fracture and fracture with defects. Four internal fixations were simulated, namely, inverted cannulated screw(ICS), ICS combined with medial buttress plate, the femoral neck system (FNS) and FNS combined with medial buttress plate. The von Mises stress, model stiffness and fracture displacements of fracture models under 2 100 N axial loads were measured and compared.@*RESULTS@#When femoral neck fracture was fixed by ICS and FNS, the peak stress was mainly concentrated on the surface of the screw near the fracture line, and the peak stress of FNS is higher than that of ICS;When the medial buttress plate was combined, the peak stress was increased and transferred to medial buttress plate, with more obvious of ICS fixation. For the same fracture model, the stiffness of FNS was higher than that of ICS. Compared with femoral neck fracture with defects, fracture model showed higher stiffness in the same internal fixation. The use of medial buttress plate increased model stiffness, but ICS increased more than FNS. The fracture displacement of ICS model exceeded that of FNS.@*CONCLUSION@#For Pauwels type Ⅲ femoral neck fracture with defects, FNS had better biomechanical properties than ICS. ICS combined with medial buttress plate can better enhance fixation stability and non-locking plate is recommended. FNS had the capability of shear resistance and needn't combine with medial buttress plate.


Subject(s)
Humans , Femoral Neck Fractures/surgery , Fracture Fixation, Internal/methods , Bone Screws , Bone Plates , Biomechanical Phenomena , Finite Element Analysis
18.
China Journal of Orthopaedics and Traumatology ; (12): 226-231, 2023.
Article in Chinese | WPRIM | ID: wpr-970852

ABSTRACT

OBJECTIVE@#To compare the efficacy of percutaneous compression plate and cannulated compression screw in the treatment of displaced femoral neck fractures in young and middle-aged patients.@*METHODS@#From January 2015 to July 2020, 68 young and middle-aged patients with displaced femoral neck fracture were retrospectively analyzed. Among them, 31 cases were fixed by percutaneous compression plate (PCCP), and 37 cases were fixed by cannulated compression screw (CCS). General data such as gender, age, cause of injury, comorbidities, fracture classification and cause of injury of two groups were collected. The operation time, intraoperative blood loss, hospital stay, full weight bearing time, fracture healing time, visual analogue scale(VAS), Harris hip score and complications were compared between two groups.@*RESULTS@#Patients in both groups were followed up for more than 2 years. There were no significant differences in operation time, intraoperative blood loss, fracture reduction quality, hospital stay and VAS between two groups. The fracture healing time in PCCP group was significantly shorter than that in CCS group (t=-4.404, P=0.000). The complete weight bearing time of PCCP group was significantly shorter than that of CCS group (t=-9.011, P=0.000). Harris score of hip joint in PCCP group was better than that in CCS group 2 years after operation (P=0.002). Complications occurred in 3 cases (9.68%) in PCCP group, while 11 cases (29.72%) in CCS group, with a statistically significant difference (P=0.042).@*CONCLUSION@#Both PCCP and CCS can be used for the treatment of displaced femoral neck fractures in young and middle-aged people. Compared with CCS, PCCP fixation can achieve shorter fracture healing time and create conditions for early full weight bearing. PCCP results in higher hip score and lower complications.


Subject(s)
Middle Aged , Humans , Treatment Outcome , Blood Loss, Surgical , Retrospective Studies , Fracture Fixation, Internal/methods , Femoral Neck Fractures/surgery , Bone Screws
19.
China Journal of Orthopaedics and Traumatology ; (12): 128-132, 2023.
Article in Chinese | WPRIM | ID: wpr-970833

ABSTRACT

OBJECTIVE@#The relationship between the distal screws and the wrist articular surface was assessed by the additional lateral oblique fluoroscopic view during the operation, and the dorsal tangential view of the wrist was used to observe whether the distal screw penetrated the dorsal cortex, so as to evaluate the clinical efficacy of the volar locking plate in the treatment of distal radius fractures.@*METHODS@#From January 2020 to June 2021, 45 cases of fresh distal radius fractures were treated using the volar Henry's approach, including 20 males and 25 females, aged from 32 to 75 years old with an average of (52.4±8.1) years old. During the operation, they were divided into 2 groups according to the different intraoperative fluoroscopic views:the control group of 20 cases, treated with standard anteroposterior and lateral fluoroscopic view;25 cases in the observation group, additional lateral oblique fluoroscopic view and dorsal tangential view of the wrist were taken. The wrist joint function score and postoperative complications were evaluated at 6 weeks, 3 and 6 months after operation between two groups.@*RESULTS@#All 45 patients were followed up and the duration ranged from 6 to 14 months, with an average of (10.8±1.7) months, all patients achieved bone union and the incision healed well. The incidence of postoperative complications in the observation group was lower than that in the control group, and the difference was statistically significant (P<0.05). In terms of Gartland-Werley score of wrist joint function, the score of wrist function in the observation group was (4.58±1.31) at 6 weeks, (2.98±0.63) at 3 months and (1.95±0.65) at 6 months post-operatively, which were better than those in the control group (6.32±1.96) at 6 weeks, (3.63±0.76) at 3 months and (2.43±0.73) at 6 months. The difference was statistically significant (P<0.05). In the observation group, 7/25 cases(28%) were found to have screw penetration during the operation by additional lateral oblique and dorsal tangential radiograph fluoroscopic views of wrist.@*CONCLUSION@#The addition of lateral oblique and dorsal tangential during the operation could improve the accuracy of distal screw placement, reduce postoperative complications, and achieve early functional exercise.


Subject(s)
Male , Female , Humans , Adult , Middle Aged , Aged , Wrist Fractures , Radius Fractures/surgery , Fracture Fixation, Internal/methods , Fluoroscopy/methods , Bone Plates , Postoperative Complications
20.
China Journal of Orthopaedics and Traumatology ; (12): 116-119, 2023.
Article in Chinese | WPRIM | ID: wpr-970830

ABSTRACT

OBJECTIVE@#To evaluate the clinical outcomes of allogeneic femoral head as strut allograft combined with proximal humeral internal locking system (PHILOS) in the treatment of proximal humeral Neer grade Ⅳ fracture with humeral head collapse.@*METHODS@#From January 2018 to November 2020, 18 patients with Neer grade Ⅳ fracture with humeral head collapse were treated with strut allograft with PHILOS, including 4 males and 14 females, aged from 55 to 78 years old, with an average of (68.11±7.20) years old. The operation time, intraoperative bleeding, postoperative drainage volume, fracture healing time, neck-shaft angle and the height of the humeral head, failure of internal fixation the shoulder function at the last follow-up was assessed using Neer's scoring system.@*RESULTS@#All 18 patients were followed up, and the duration ranged from 10 to 12 months, with an average of (11.08±0.65) months. The operation time was (66.44±5.06) min, the intraoperative bleeding volume was (206.67±36.14) ml, the postoperative drainage volume was (76.11±9.63) ml, and the fracture healing time was (17.28±3.92) weeks. At the last follow-up, the degree of loss of neck-shaft angle was (5.44±0.86) ° and the loss of the height of humeral head was (1.43±0.27) mm. All 18 patients had healing without complications such as fracture, withdrawal, penetration of internal fixation and necrosis of humeral head. According to Neer's evaluation standard, the total score was (89.61±5.60), 10 cases got an excellent result, 6 good, 2 fair.@*CONCLUSION@#Allogeneic femoral head combined with PHILOS is an appropriate treatment for the four-part proximal humerus fractures with humeral head collapse, exhibiting good clinic outcome.


Subject(s)
Male , Female , Humans , Middle Aged , Aged , Humeral Head , Shoulder , Treatment Outcome , Bone Plates , Retrospective Studies , Humerus , Shoulder Fractures/surgery , Fracture Fixation, Internal/adverse effects , Humeral Fractures , Allografts
SELECTION OF CITATIONS
SEARCH DETAIL