Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 786
Filter
1.
China Journal of Orthopaedics and Traumatology ; (12): 7-14, 2024.
Article in Chinese | WPRIM | ID: wpr-1009216

ABSTRACT

OBJECTIVE@#To investigate the clinical effect of unilateral percutaneous vertebroplasty (PVP) combined with 3D printing technology for the treatment of thoracolumbar osteoporotic compression fracture.@*METHODS@#A total of 77 patients with thoracolumbar osteoporotic compression fractures from October 2020 to April 2022 were included in the study, all of which were vertebral body compression fractures caused by trauma. According to different treatment methods, they were divided into experimental group and control group. Thirty-two patients used 3D printing technology to improve unilateral transpedicle puncture vertebroplasty in the experimental group, there were 5 males and 27 females, aged from 63 to 91 years old with an average of (77.59±8.75) years old. Forty-five patients were treated with traditional bilateral pedicle puncture vertebroplasty, including 7 males and 38 females, aged from 60 to 88 years old with an average of(74.89±7.37) years old. Operation time, intraoperative C-arm X-ray times, anesthetic dosage, bone cement injection amount, bone cement diffusion good and good rate, complications, vertebral height, kyphotic angle (Cobb angle), visual analogue scale(VAS), Oswestry disability index (ODI) and other indicators were recorded before and after surgery, and statistically analyzed.@*RESULTS@#All patients were followed up for 6 to 23 months, with preoperative imaging studies, confirmed for thoracolumbar osteoporosis compression fractures, two groups of patients with postoperative complications, no special two groups of patients' age, gender, body mass index (BMI), time were injured, the injured vertebral distribution had no statistical difference(P>0.05), comparable data. Two groups of patients with bone cement injection, bone cement dispersion rate, preoperative and postoperative vertebral body height, protruding after spine angle(Cobb angle), VAS, ODI had no statistical difference(P>0.05). The operative time, intraoperative fluoroscopy times and anesthetic dosage were statistically different between the two groups(P<0.05). Compared with the traditional bilateral puncture group, the modified unilateral puncture group combined with 3D printing technology had shorter operation time, fewer intraoperative fluoroscopy times and less anesthetic dosage. The height of anterior vertebral edge, kyphosis angle (Cobb angle), VAS score and ODI of the affected vertebrae were statistically different between two groups at each time point after surgery(P<0.05).@*CONCLUSION@#In the treatment of thoracolumbar osteoporotic compression fractures, 3D printing technology is used to improve unilateral puncture PVP, which is convenient and simple, less trauma, short operation time, fewer fluoroscopy times, satisfactory distribution of bone cement, vertebral height recovery and kyphotic Angle correction, and good functional improvement.


Subject(s)
Male , Female , Humans , Middle Aged , Aged , Aged, 80 and over , Fractures, Compression/surgery , Spinal Fractures/surgery , Bone Cements , Treatment Outcome , Vertebroplasty/methods , Kyphosis/surgery , Punctures , Printing, Three-Dimensional , Technology , Osteoporotic Fractures/surgery , Anesthetics , Retrospective Studies , Kyphoplasty/methods
2.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 395-400, 2024.
Article in Chinese | WPRIM | ID: wpr-1016573

ABSTRACT

@#After years of development, the advantages of computer-assisted orthognathic surgery have been widely recognized. However, the clinical application of this technology is challenging. Each step may generate errors from data acquisition, computer-assisted diagnosis, and computer-assisted surgical design, causing errors to be transferred from the virtual surgical plan to the operation. The accumulation and amplification of errors will affect the final surgical effect. Currently, digital devices, such as intraoral scanners, are being explored for error control, utilizing automation methods and algorithms, and implementing personalized bone positioning methods. Moreover, there are still many problems that have not been fully resolved, such as precise simulation of postoperative soft tissue, functional assessment of mandibular movement, and absorbable internal fixation materials. Fully understanding computer-assisted orthognathic surgery's limitations could provide direction for optimizing existing methods while helping clinicians avoid risks and maximize its advantages to achieve the best outcome. Many emerging and cutting-edge technologies, such as personalized titanium plates, artificial intelligence, and surgical robots, will further promote the development of this discipline. We can expect future optimization of digital orthognathic surgical technology by innovations in automation, intelligence, and personalization.

3.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 280-286, 2024.
Article in Chinese | WPRIM | ID: wpr-1013089

ABSTRACT

Objective@#Based on 3D printing technology, explore the precision of a perforator vessel location guide plate for fibular musculocutaneous flaps before the transplantation of fibular osteocutaneous flaps and evaluate its application effects.@*Methods@#This study was reviewed and approved by the ethics committee, and informed consent was obtained from the patients. From May 2019 to October 2022, 14 patients with jaw defects who needed to undergo fibular perforator flap transplantation at the First Affiliated Hospital of Xinjiang Medical University were selected. For the seven patients in the guide plate group, CTA was combined with Mimics software to reconstruct both lower limbs, and the perforator vessel positioning guide for locating perforator vessels was designed; the two ends of the guide plate were designed as fixed ends, with the upper end fixed to the knee joint and the lower end fixed to the ankle joint, and the guide plate was fabricated by a 3D printer. For the seven patients in the control group, a conventional handheld Doppler probe was used for perforator vessel location. The average operation time, bleeding volume, recovery time, deviation of perforator vessel location, postoperative flap-related complications, postoperative donor site shape satisfaction, and lower extremity functional scale (LEFS) score were recorded. SPSS 25.0 software was used for statistical analysis.@*Results@#The average operation time, bleeding volume, recovery time, deviation of perforator vessel location and postoperative donor site shape satisfaction were significantly better in the guide plate group than in the control group (P<0.05); moreover, the differences in postoperative flap-related complications and LEFS scores were not statistically significant (P>0.05).@*Conclusion@#Based on 3D printing technology, fibular musculocutaneous flap perforator vessels can be more accurately located using a guide plate and the knee and ankle as fixed points, and this method can effectively stabilize the guide position, prevent soft tissue offset, and improve positioning accuracy and thus deserves to be generalized.

4.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 249-256, 2024.
Article in Chinese | WPRIM | ID: wpr-1013085

ABSTRACT

Objective@#To evaluate the bone repair effect of 3D-printed magnesium (Mg)-loaded polycaprolactone (PCL) scaffolds in a rat skull defect model.@*Methods@#PCL scaffolds mixed with Mg microparticles were prepared by using 3D printing technology, as were pure PCL scaffolds. The surface morphologies of the two scaffolds were observed by scanning electron microscopy (SEM), and the surface elemental composition was analyzed via energy dispersive spectroscopy (EDS). The physical properties of the scaffolds were characterized through contact angle measurements and an electronic universal testing machine. This study has been reviewed and approved by the Ethics Committee. A critical size defect model was established in the skull of 15 Sprague-Dawley (SD) rats, which were divided into the PCL group, PCL-Mg group, and untreated group, with 5 rats in each group. Micro-CT scanning was performed to detect and analyze skull defect healing at 4 and 8 weeks after surgery, and samples from the skull defect area and major organs of the rats were obtained for histological staining at 8 weeks after surgery.@*Results@#The scaffolds had a pore size of (480 ± 25) μm, a fiber diameter of (300 ± 25) μm, and a porosity of approximately 66%. The PCL-Mg scaffolds contained 1.0 At% Mg, indicating successful incorporation of Mg microparticles. The contact angle of the PCL-Mg scaffolds was 68.97° ± 1.39°, indicating improved wettability compared to that of pure PCL scaffolds. Additionally, compared with that of pure PCL scaffolds, the compressive modulus of the PCL-Mg scaffolds was (57.37 ± 8.33) MPa, demonstrating enhanced strength. The PCL-Mg group exhibited the best bone formation behavior in the skull defect area compared with the control group and PCL group at 4 and 8 weeks after surgery. Moreover, quantitative parameters, such as bone volume (BV), bone volume/total volume (BV/TV), bone surface (BS), bone surface/total volume (BS/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N) and bone mineral density (BMD), of skull defects were better than those in the other groups, indicating the best bone regeneration effect. H&E, Goldner, and VG staining revealed more mineralized new bone formation in the PCL-Mg group than in the other groups, and H&E staining of the major organs revealed good biosafety of the material.@*Conclusion@#PCL-Mg scaffolds can promote the repair of bone defects and have clinical potential as a new scaffold material for the repair of maxillofacial bone defects.

5.
Acta Pharmaceutica Sinica B ; (6): 392-404, 2024.
Article in English | WPRIM | ID: wpr-1011240

ABSTRACT

Nasal drug delivery efficiency is highly dependent on the position in which the drug is deposited in the nasal cavity. However, no reliable method is currently available to assess its impact on delivery performance. In this study, a biomimetic nasal model based on three-dimensional (3D) reconstruction and three-dimensional printing (3DP) technology was developed for visualizing the deposition of drug powders in the nasal cavity. The results showed significant differences in cavity area and volume and powder distribution in the anterior part of the biomimetic nasal model of Chinese males and females. The nasal cavity model was modified with dimethicone and validated to be suitable for the deposition test. The experimental device produced the most satisfactory results with five spray times. Furthermore, particle sizes and spray angles were found to significantly affect the experimental device's performance and alter drug distribution, respectively. Additionally, mometasone furoate (MF) nasal spray (NS) distribution patterns were investigated in a goat nasal cavity model and three male goat noses, confirming the in vitro and in vivo correlation. In conclusion, the developed human nasal structure biomimetic device has the potential to be a valuable tool for assessing nasal drug delivery system deposition and distribution.

6.
Article in English | LILACS-Express | LILACS | ID: biblio-1550993

ABSTRACT

Introduction: Three-dimensional printing is one of the technologies that promote change at an economic and social level, and one of the fundamental elements of industry 4.0. It has enormous potential for the future of medicine, establishing itself as a new paradigm. Despite its advantages, its use in our environment is incipient. Objective: To design and develop solutions based on three-dimensional technologies for the teaching and practice of biomedical sciences. Materials and methods: A technological development investigation was carried out between the Center for Assisted and Sustainable Manufacturing of the University of Matanzas and Matanzas University of Medical Sciences, between September 2019 and July 2022. The designs and fabrications were made from the acquisition of computed tomography images, or from a surface scanner, which were then processed, converted into Standard Tessellation Language format, printed, and post-processed. Virtual designs were developed using computer-aided design software. Results: Various solutions were developed including prototypes: biomodels for craniosynostosis repair and anatomical figures, custom cranial prosthesis mold, hand prosthesis, O2 line splitters, tissue scaffolds, syringe gun, face shields, breast prosthesis; autologous restoration mold and tissue expander. Conclusions: In all areas of application of this technology in medicine―except the printing of medicines, in the current context―, it is feasible to obtain solutions in the territory of Matanzas. It is therefore imperative that managers and the medical community in general, begin to acquire awareness, knowledge, and experience to ensure the optimal use of this technology.


Introducción: La impresión tridimensional es una de las tecnologías que promueve el cambio a nivel económico y social, y uno de los elementos fundamentales de la industria 4.0. Asimismo, constituye un enorme potencial para el futuro de la medicina, estableciéndose como un nuevo paradigma. A pesar de sus ventajas, su explotación en nuestro medio es incipiente. Objetivos: Diseñar y desarrollar soluciones basadas en tecnologías tridimensionales para la enseñanza y la práctica de las ciencias biomédicas. Materiales y métodos: Se realizó una investigación colaborativa, de desarrollo tecnológico entre el Centro de Fabricación Asistida y Sostenible de la Universidad de Matanzas y la Universidad de Ciencias Médicas de Matanzas, entre septiembre de 2019 y julio de 2022. Los diseños y fabricaciones se realizaron a partir de la adquisición de imágenes de tomografía computarizada, o desde un escáner de superficie, las que luego se procesaron, se convirtieron en formato Standard Tessellation Language, se imprimieron y posprocesaron. Los diseños virtuales se desarrollaron empleando un software de diseño asistido por computadora. Resultados: Se desarrollaron varias soluciones que incluyen varios prototipos: biomodelos para reparación de craneosinostosis y figuras anatómicas, molde de prótesis craneal personalizada, prótesis de mano, divisores de líneas de O2, andamios tisulares, pistola portajeringas, protectores faciales, prótesis de mama, molde para restauración autóloga y expansor tisular. Conclusiones: En todas las áreas de aplicación de esta tecnología en medicina―salvo en la impresión de medicamentos, en el contexto actual―, es factible obtener soluciones en el territorio de Matanzas. Es un imperativo, pues, que directivos y la comunidad médica en general, comiencen a adquirir conciencia, conocimientos y experiencias para garantizar la utilización óptima de esta tecnología.

7.
Odovtos (En línea) ; 25(3): 82-98, Sep.-Dec. 2023. tab, graf
Article in English | LILACS, SaludCR | ID: biblio-1529071

ABSTRACT

Abstract To evaluate the microtensile bond strength (µTBS) of two resin cements to 3D printed and milled CAD/CAM resins used for provisional fixed partial dentures. Blocks (5 x 5 x 5 mm) of three 3D-printed resins (Cosmos3DTemp / Yller; Resilab3D Temp / Wilcos and SmartPrint BioTemp, / MMTech) were printed (Photon, Anycubic Technology Co.). A milled material (VitaCAD-Temp, VITA) was used as control. Half the specimens were sandblasted and the rest were untreated. Two blocks were bonded with the corresponding resin cement: PanaviaV5 (Kuraray Noritake) and RelyX Ultimate (3M Oral Care). After 24 hours, the bonded blocks were sectioned into 1 x 1 mm side sticks. Half the beams were tested for µTBS and the other half was thermocycled (5000 cycles, 30s dwell-time, 5s transfer time) before µTBS testing. A four way Generalized Linear Model (material*sandblasting*cement*aging) analysis was applied. VITA exhibited the lowest µTBS, regardless of the cement, sandblasting and thermocycling. Sandblasting significantly improved the µTBS of VIT, especially after aging, but did not improve the µTBS of 3D printed resins. Sandblasting was not beneficial for 3D printed resins, although is crucial for adhesive cementation of milled temporary resins. Airborne particle abrasion affects the integrity of 3D-printed resins, without producing a benefit on the microtensile bond strength of these materials. However, sandblasting is crucial to achieve a high bond strength on milled temporary resins.


Resumen Evaluar la resistencia adhesiva en microtracción (µTBS) de dos cementos resinosos a resinas CAD/CAM impresas y fresadas indicadas para restauraciones provisionales. Bloques (5 x 5 x 5mm) de tres resinas impresas (Cosmos3DTemp / Yller; Resilab3D Temp / Wilcos and SmartPrint BioTemp, / MMTech) y una resina fresada (VitaCAD-Temp, VITA) fueron fabricados. La mitad de los especímenes fueron arenados y el resto no recibió tratamiento mecánico. Dos bloques con condiciones de tratamiento iguales fueron cementados con cemento resinoso (PanaviaV5 / Kuraray Noritake y RelyX Ultimate / 3M Oral Care). Después de 24 horas los bloques fueron seccionados en palitos de 1 mm² de área. En la mitad de los especímenes se midió la TBS inmediatamente y el resto fue termociclado (5000 ciclos, 30s remojo, 5s transferencia) antes de la prueba de TBS. Se aplica un análisis estadístico por Modelo Linear General con 4 factores (material*arenado*cemento*termociclado). La resina VITA presentó la menor µTBS, independientemente del cemento usado, el arenado y el termociclado. Sin embargo, el arenado aumentó la µTBS de VIT, especialmente después del termociclado. Por otro lado, el arenado no resultó en un aumento significativo de la µTBS de las resinas impresas. El arenado no fue beneficiosos para las resinas impresas, aunque es un paso crucial para la cementación adhesive de las resinas fresadas. El arenado afecta la integridad de las capas de las resinas impresas, sin generar un beneficio en la TBS.


Subject(s)
Computer-Aided Design/instrumentation , Resin Cements/therapeutic use , Dental Cementum , Printing, Three-Dimensional/instrumentation
8.
Humanidad. med ; 23(3)dic. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1534560

ABSTRACT

Las enfermedades raras son aquellas que tienen baja prevalencia y que, por lo tanto, el desarrollo de medicamentos para tratarlas no es rentable para las empresas farmacéuticas debido a la baja demanda. A pesar de que ya se cuenta con diferentes políticas públicas alrededor del mundo para incentivar a las industrias farmacéuticas a investigar estos medicamentos, conocidos como medicamentos huérfanos, su desarrollo conlleva muchas dificultades en las evaluaciones clínicas y el precio final para el público es muy elevado. Si bien en años recientes se ha planteado el uso de tecnología de impresión en 3D para producir estos medicamentos o incluso recurrir a otros medicamentos previamente aprobados para tratar enfermedades raras, existe un historial de mal uso de las legislaciones por parte de las empresas con el fin de generar beneficios comerciales, por lo que estas políticas deben reforzarse para que cumplan su propósito; ayudar a una población muy vulnerable. El objetivo del presente texto es exponer los resultados de una revisión documental sobre el panorama científico y sociopolítico en el que se encuentra el problema de las enfermedades raras y los medicamentos huérfanos, así como las posibles soluciones que se están desplegando para abordarlo. Deriva de un estudio que se desarrolla en el momento actual en la Universidad Autónoma Metropolitana, de Ciudad de México.


The strange illnesses are those that have low prevalence and that, therefore, the development of medications to treat them is not profitable for the pharmaceutical companies due to the drop demands. Although it is already counted with different political public around the world to motivate to the pharmaceutical industries to investigate these medications, well-known as orphan medications, their development bears many difficulties in the clinical evaluations and the final price for the public it is very high. Although in recent years he/she has thought about the use of impression technology in 3D to produce these medications or even to appeal to other medications previously approved to treat strange illnesses, a record of wrong use of the legislations exists on the part of the companies with the purpose of generating commercial benefits, for what these politicians should be reinforced so that they complete its purpose; to help a very vulnerable population. The objective of the present text is to expose the results of a documental revision on the scientific and sociopolitical panorama in which is the problem of the strange illnesses and the orphan medications, as well as the possible solutions that they are spreading to approach it. It derives of a study that is developed in the current moment in the Metropolitan Autonomous University, of Mexico City.

9.
Rev. Estomat ; 31(2): 1-8, 20230929.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1511309

ABSTRACT

Antecedentes: El conocimiento anatómico de la cámara pulpar y del sistema de conductos radiculareses fundamental para el correcto diagnóstico y planificación del tratamiento en endodoncia. Las herramientas pedagógicasdirigidasa los estudiantes de odontologíacomo apoyo en los procesos formativosde la asignatura de endodoncia favorecen la apropiación del conocimiento e identificación de las variantes morfológicas del sistema de conductos radiculares, que permiten al estudiantela integración del conocimiento. Objetivo:Identificar mediante una revisión de la literatura las estrategias pedagógicas que se utilizan para la enseñanza de morfología del sistema de conductos radiculares en endodoncia. Materiales y métodos: Se realizó una búsqueda bibliográfica de estudios originales en las bases de datos Medline (Pubmed), SciELO, Lilacs, Medline (Ovid), Web of science, Scopus, Embase, Google académico, eligiendo estudios publicadosa partir del año 2010 al 2022, para la selección de los artículos definitivos se seleccionaron estudios concernientes a procesos pedagógicos en endodoncia, excluyendo así otros tipos de enfoques en el área de odontología. Resultados: Se identificaron un total de 63 referencias, los cuales fueron analizados y seleccionados16, siendo excluidos 47 por no cumplir los criterios de inclusión. Conclusión: El uso de herramientas pedagógicas virtuales, didácticas y tecnológicas propician un efecto positivo en el estudiante de pregrado de odontología durante el aprendizaje de anatomía de sistemas de conductos radiculares que aumentan la confianza y seguridad al momento de realizar un tratamiento endodóntico en pacientes


Background: Anatomical knowledge of the pulp chamber and the root canal system is essential for correct diagnosis and treatment planning in endodontics. The pedagogical tools aimed at dental students as support in the training processes of the endodontics subject favor the appropriation of knowledge and identification of the morphological variants of the root canal system, which allow the student the integration of knowledge. Objective: To identify, through a review of the literature, the pedagogical strategies used to teach morphology of the root canal system in endodontics. Materials and methods: A bibliographic search of original studies was carried out in the Medline (Pubmed), SciELO, Lilacs, Medline (Ovid), Web of Science, Scopus, Embase, and Google academic databases, choosing studies published from 2010 to 2022. , for the selection of the definitive articles, studies concerning pedagogical processes in endodontics were selected, thus excluding other types of approaches in the area of dentistry. Results: A total of 63 references were identified, 16 of which were analyzed and selected, 47 being excluded for not meeting the inclusion criteria. Conclusion: The use of virtual, didactic and technological pedagogical tools favor a positive effect on the dentistry undergraduate student while learning the anatomy of root canal systems that increase confidence and security when performing endodontic treatment in patients.

10.
Rev. bras. ortop ; 58(4): 604-610, July-Aug. 2023. graf
Article in English | LILACS | ID: biblio-1521797

ABSTRACT

Abstract Objective The interest in using 3D printing in the healthcare field has grown over the years, given its advantages and potential in the rapid manufacturing of personalized devices and implants with complex geometries. Thus, the aim of the present study was to compare the mechanical fixation behavior of a 3D-printed interference screw, produced by fused deposition modeling of polylactic acid (PLA) filament, with that of a titanium interference screw. Methods Eight deep flexor porcine tendons, approximately 8 mm wide and 9 cm long, were used as graft and fixed to a 40 pounds-per-cubic-foot (PCF) polyurethane block at each of its extremities. One group was fixed only with titanium interference screws (group 1) and the other only with 3D-printed PLA screws (BR 20 2021 018283-6 U2) (group 2). The tests were conducted using an EMIC DL 10000 electromechanical universal testing machine in axial traction mode. Results Group 1 (titanium) obtained peak force of 200 ± 7 N, with mean graft deformation of 8 ± 2 mm, and group 2 (PLA) obtained peak force of 300 ± 30 N, and mean graft deformation of 7 ± 3 mm. Both the titanium and PLA screws provided good graft fixation in the polyurethane block, with no slippage or apparent deformation. In all the samples, the test culminated in graft rupture, with around 20 mm of deformation in relation to the initial length. Conclusion The 3D-printed PLA screw provided good fixation, similar to that of its titanium counterpart, producing satisfactory and promising results.


Resumo Objetivo O interesse em utilizar a impressão 3D na área da saúde tem crescido ao longo dos anos, dadas as suas vantagens e o seu potencial na rápida fabricação de dispositivos e implantes personalizados com geometrias complexas. Assim, o objetivo do presente estudo foi comparar o comportamento de fixação mecânica de um parafuso de interferência impresso em 3D, produzido pela modelagem fundida de deposição do filamento de ácido polilático (PLA), com o de um parafuso de interferência de titânio. Métodos Oito tendões suínos flexores profundos, de aproximadamente 8 mm de largura e 9 cm de comprimento, foram utilizados como enxerto e fixados em um bloco de poliuretano de 40 PCF em cada uma de suas extremidades. Um grupo foi fixado apenas com parafusos de interferência de titânio (grupo 1) e o outro apenas com parafusos PLA impressos em 3D (BR 20 2021 018283-6 U2) (grupo 2). Os testes foram realizados utilizando uma máquina de teste universal eletromecânica EMIC DL 10.000 no modo de tração axial. Resultados O grupo 1 (titânio) obteve força máxima de 200 ± 7 N com deformação média do enxerto de 8 ± 2 mm, e a força máxima do grupo 2 (PLA) foi de 300 ± 30 N e deformação média do enxerto de 7 ± 3 mm. Ambos os parafusos de titânio e PLA forneceram boa fixação de enxerto no bloco de poliuretano, sem deslizamento ou deformação aparente. Em todas as amostras o teste culminou na ruptura do enxerto, com cerca de 20 mm de deformação em relação ao comprimento inicial. Conclusão O parafuso PLA impresso em 3D proporcionou boa fixação, semelhante à de sua contraparte de titânio, produzindo resultados satisfatórios e promissores.


Subject(s)
Animals , Swine , Tendons/surgery , Bone Screws , Lactic Acid , Printing, Three-Dimensional
11.
Odovtos (En línea) ; 25(2)ago. 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1448737

ABSTRACT

The objective is to determine which biopolymer has the best 3D printing characteristics and mechanical properties for the manufacture of a bioscaffold, using the fused deposition printing technique, with models generated from an STL file obtained from a Micro-CT scan taken from a bovine iliac crest bone structure. Through an experimental exploratory study, three study groups of the analyzed biopolymers were carried out with thirteen printed structures of each one. The first is made of 100% PLA. The second, 90B, we added 1g of diatom extract, and the third, 88C, differs from the previous one in that it also contains 1g of calcium phosphate. The 39 printed structures underwent a visual inspection test, which required the fabrication of a gold standard scaffold in resin, with greater detail and similarity to the scanned bone structure. Finally, the structures were subjected to a compressive force (N) to obtain the modulus of elasticity (MPa) and compressive strength (MPa) of each one of them. A statistically significant difference (p=0.001) was obtained in the printing properties of the biomaterial 88C, compared to 90B and pure PLA and the 88C presented the best 3D printing characteristics. In addition, it also presented the best mechanical properties compared to the other groups of materials. Although the difference between these was not statistically significant (p=0.388), in the structures of the 88C biomaterial, values of compressive strength (8,84692 MPa) and modulus of elasticity (43,23615 MPa) were similar to those of cancellous bone in the jaws could be observed. Because of this result, the 88C biomaterial has the potential to be used in the manufacture of bioscaffolds in tissue engineering.


El objetivo es determinar cuál biopolímero presenta las mejores características de impresión 3D y propiedades mecánicas para la fabricación de un bioandamiaje, utilizando la técnica de impresión por deposición fundida, con modelos generados a partir de un archivo en formato STL que se obtuvo de un Micro-CT Scan de una estructura osea de cresta iliaca bovina. Mediante un estudio exploratorio, se realizaron 3 grupos de estudio con trece estructuras impresas de cada uno. El primero, se compone 100% de PLA. El segundo, 90B, se le agrega 1g de extracto de diatomea, y el tercero, 88C, se diferencia del anterior ya que contiene además, 1g de fosfato de calcio. A las 39 estructuras impresas se les realizó una prueba de inspección visual, por lo que se requirió la confección de un patrón de oro en resina, con mayor detalle y similitud a la estructura ósea escaneada. Finalmente, las estructuras fueron sometidas a una fuerza compresiva (N) para la obtención del módulo de elasticidad (MPa) y de la resistencia compresiva (MPa) de cada una de ellas. Se obtuvo una diferencia estadísticamente significativa (p=0,001) en las propiedades de impresión del biomaterial 88C, con respecto al 90B y al PLA puro, presentando las mejores características de impresión 3D. Además, obtuvo las mejores propiedades mecánicas en comparación con los otros grupos de materiales. Aunque la diferencia entre estos no fue estadísticamente significativa (p=0,388), en las estructuras del biomaterial 88C, se pudieron observar valores de resistencia compresiva (8,84692 MPa) y módulo de elasticidad (43,23615 MPa) que son semejantes a los del hueso esponjoso de los maxilares. A razón de este resultado, el biomaterial 88C cuenta con el potencial para ser utilizado en la fabricación de bioandamiajes en la ingeniería tisular.

12.
Int. j. morphol ; 41(3): 690-698, jun. 2023. ilus, tab, graf
Article in Spanish | LILACS | ID: biblio-1514320

ABSTRACT

El uso de nuevos recursos tecnológicos en la enseñanza de anatomía ha impulsado la necesidad de adaptar el modelo educativo haciéndolo más centrado en el estudiante, dinámico y participativo mediante herramientas digitales y 3D; orientando los conocimientos hacia su aplicación clínica, pero bajo un ajuste curricular que tiende a cursar menos horas presenciales en aula o laboratorio. Este trabajo describe la experiencia local de una nueva Escuela de Medicina en Chile, reportada el año 2018, además y otros trabajos de centros formadores presentados en el "SECTRA Users Meeting 2019 Estocolmo", Karolinska Institutet, Suecia. Este trabajo describe los reportes orales sobre la aplicación de nuevos recursos digitales como; la mesa de disección digital táctil SECTRA® y modelos anatómicos cadavéricos impresos en 3D Erler-Zimmer®, bases de datos sobre anatomía digital, además, su impacto en el desempeño académico, reportado por usuarios de diferentes países, tales como: Australia, Canadá, Chile, China, Colombia, Estados Unidos de Norteamérica (EUA) y Suecia. Los datos fueron recopilados y analizados a partir de la información reportada en las presentaciones orales y resúmenes entregados por los expositores. La gran mayoría de los países expositores declararon el uso combinado de recursos digitales y 3D sumados a los tradicionales para la enseñanza de anatomía. Sólo el representante de EUA declaró usar exclusivamente recursos digitales (en laboratorio y en línea), experiencia correspondiente a una joven e innovadora escuela de medicina. La mayoría de los centros docentes declaró utilizar la mesa de disección digital en una amplia proporción de sus contenidos curriculares, en asociación a plataformas tipo RIS/PACS como IDS7 portal de SECTRA o las utilizadas por el centro formador. El uso de nuevas tecnologías digitales y 3D ha ganado un importante espacio en el currículum de la enseñanza de anatomía, complementando el uso de los recursos tradicionales.


SUMMARY: The use of new technological resources in the teaching of anatomy has promoted the need to adapt the educational model, making it more student-centered, dynamic, and participatory through digital and 3D tools, directing the knowledge towards its clinical application, but under a curricular adjustment that tends to take fewer contact hours in the classroom or laboratory. This work describes the local experience of a new School of Medicine in Chile, reported in 2018, and other work from training centers presented at the "SECTRA Users Meeting 2019 Stockholm", Karolinska Institutet, Sweden. This work describes the oral reports on the application of new digital resources such as; the SECTRA® digital tactile dissection table and Erler- Zimmer® 3D printed cadaveric anatomical models, databases on digital anatomy, in addition, its impact on academic performance, reported by users from different countries, such as Australia, Canada, Chile, China, Colombia, United States of America (USA) and Sweden. The data was collected and analyzed from the information reported in the oral presentations and summaries delivered by the speakers.The vast majority of the exhibiting countries declared the combined use of digital and 3D resources added to the traditional ones for teaching anatomy. Only the representative from the USA stated that they exclusively used digital resources (in the laboratory and online), an experience corresponding to a young and innovative medical school. Most of the educational centers stated that they used the digital dissection table in a large proportion of their curricular contents, in association with RIS/PACS-type platforms such as the IDS7 SECTRA portal or those used by the training center. The use of new digital and 3D technologies has gained an important space in the anatomy teaching curriculum, complementing the use of traditional resources.


Subject(s)
Humans , Universities , Health Education/trends , Educational Technology , Printing, Three-Dimensional , Anatomy/education
13.
Rev. bras. ortop ; 58(2): 284-289, Mar.-Apr. 2023. tab, graf
Article in English | LILACS | ID: biblio-1449810

ABSTRACT

Abstract Objective Due to the popularity of 3D technology, surgeons can create specific surgical guides and sterilize them in their institutions. The aim of the present study is to compare the efficacy of the autoclave and ethylene oxide (EO) sterilization methods for objects produced by 3D printing with polylactic acid (PLA) material. Methods Forty cubic-shaped objects were printed with PLA material. Twenty were solid and 20 were hollow (printed with little internal filling). Twenty objects (10 solid and 10 hollow) were sterilized in autoclave, forming Group 1. The others (10 solid and 10 hollow) were sterilized in EO, composing Group 2. After sterilization, they were stored and referred to culture. Hollow objects of both groups were broken during sowing, communicating the dead space with the culture medium. The results obtained were statistically analyzed (Fisher exact test and residue analysis). Results In group 1 (autoclave), there was bacterial growth in 50% of solid objects and in 30% of hollow objects. In group 2 (EO), growth occurred in 20% of hollow objects, with no bacterial growth in solid objects (100% of negative samples). The bacteria isolated in the positive cases was non-coagulase-producing Staphylococcus Gram positive. Conclusions Sterilization by both autoclave and EO was not effective for hollow printed objects. Solid objects sterilized by autoclave did not demonstrate 100% of negative samples and were not safe in the present assay. Complete absence of contamination occurred only with solid objects sterilized by EO, which is the combination recommended by the authors.


Resumo Objetivo Devido à popularidade da tecnologia 3D, cirurgiões podem criar guias cirúrgicos específicos e esterilizá-los nas suas instituições. O objetivo do presente estudo é comparar a eficácia dos métodos de esterilização por autoclave e óxido de etileno (OE) de objetos produzidos pela impressão 3D com material ácido polilático (PLA, na sigla em inglês). Métodos Quarenta objetos em formato cúbico foram impressos com material de PLA. Vinte eram sólidos e 20 eram ocos (impressos com pouco enchimento interno). Vinte objetos (10 sólidos e 10 ocos) foram esterilizados em autoclave, formando o Grupo 1. Os demais (10 sólidos e 10 ocos) foram esterilizados em OE, compondo o Grupo 2. Após a esterilização, os objetos foram armazenados e encaminhados para cultura. Objetos ocos de ambos os grupos foram quebrados durante a semeadura, comunicando o espaço morto com o meio de cultura. Os resultados obtidos foram analisados estatisticamente (teste exato de Fisher e análise de resíduo). Resultados No grupo 1 (autoclave) houve crescimento bacteriano em 50% dos objetos sólidos e em 30% dos objetos ocos. No grupo 2 (OE) o crescimento ocorreu em 20% dos objetos ocos, com ausência de crescimento bacteriano nos objetos sólidos (100% de amostras negativas). A bactéria isolada nos casos positivos foi Staphylococcus Gram positivo não produtor de coagulase. Conclusões A esterilização tanto em autoclave quanto pelo OE não foi eficaz para objetos impressos no formato oco. Objetos sólidos esterilizados em autoclave não demonstraram 100% de amostras negativas, não sendo seguro no presente ensaio. Ausência completa de contaminação ocorreu apenas com objetos sólidos esterilizados pelo OE, sendo a combinação recomendada pelos autores.


Subject(s)
Humans , Arthroplasty, Replacement, Hip/rehabilitation , Analgesia , Injections, Intra-Articular
14.
Rev. bras. ortop ; 58(2): 303-312, Mar.-Apr. 2023. tab, graf
Article in English | LILACS | ID: biblio-1449806

ABSTRACT

Abstract Objective To evaluate a proposed three-dimensional (3D) printing process of a biomodel developed with the aid of fused deposition modeling (FDM) technology based on computed tomography (CT) scans of an individual with nonunion of a coronal femoral condyle fracture (Hoffa's fracture). Materials and Methods Thus, we used CT scans, which enable the evaluation of the 3D volumetric reconstruction of the anatomical model, as well as of the architecture and bone geometry of sites with complex anatomy, such as the joints. In addition, it enables the development of the virtual surgical planning (VSP) in a computer-aided design (CAD) software. This technology makes it possible to print full-scale anatomical models that can be used in surgical simulations for training and in the choice of the best placement of the implant according to the VSP. In the radiographic evaluation of the osteosynthesis of the Hoffa's fracture nonunion, we assessed the position of the implant in the 3D-printed anatomical model and in the patient's knee. Results The 3D-printed anatomical model showed geometric and morphological characteristics similar to those of the actual bone. The position of the implants in relation to the nonunion line and anatomical landmarks showed great accuracy in the comparison of the patient's knee with the 3D-printed anatomical model. Conclusion The use of the virtual anatomical model and the 3D-printed anatomical model with the additive manufacturing (AM) technology proved to be effective and useful in planning and performing the surgical treatment of Hoffa's fracture nonunion. Thus, it showed great accuracy in the reproducibility of the virtual surgical planning and the 3D-printed anatomical model.


Resumo Objetivo Avaliar uma proposta de processo de impressão tridimensional (3D) de um biomodelo preparado com o auxílio da tecnologia de modelagem por deposição de material fundido (fused deposition modeling, FDM, em inglês) a partir de imagens de tomografia computadorizada (TC) de um indivíduo com pseudartrose de fratura coronal do côndilo femoral (fratura de Hoffa). Materiais e Métodos Para tanto, utilizamos imagens de TC, que permitem estudar a reconstrução volumétrica 3D do modelo anatômico, além da arquitetura e geometria óssea de sítios de anatomia complexa, como as articulações. Também permite o planejamento cirúrgico virtual (PCV) em um programa de desenho assistido por computador (computer-aided design, CAD, em inglês). Essa tecnologia possibilita a impressão de modelos anatômicos em escala real que podem ser utilizados em simulações cirúrgicas para o treinamento e a escolha do melhor posicionamento do implante de acordo com o PCV. Na avaliação radiográfica da osteossíntese da pseudartrose de Hoffa, verificou-se a posição do implante no modelo anatômico impresso em 3D e no joelho do paciente. Resultados O modelo anatômico impresso em 3D apresentou características geométricas e morfológicas semelhantes às do osso real. O posicionamento dos implantes em relação à linha de pseudartrose e pontos anatômicos foram bastante precisos na comparação do joelho do paciente com o modelo anatômico impresso em 3D. Conclusão A utilização do modelo anatômico virtual e do modelo anatômico impresso em 3D com a tecnologia de manufatura aditiva (MA) foi eficaz e auxiliou o planejamento e a realização do tratamento cirúrgico da pseudartrose da fratura de Hoffa. Desta forma, foi bastante preciso na reprodutibilidade do planejamento cirúrgico tanto virtual quanto no modelo anatômico impresso em 3D.


Subject(s)
Humans , Pseudarthrosis , Orthopedic Procedures , Printing, Three-Dimensional , Hoffa Fracture/surgery
15.
Article | IMSEAR | ID: sea-222444

ABSTRACT

This case report describes three cases in which periapical surgeries were carried out using a new surgical endodontic technique by using a three?dimensional (3D) printed template for guided osteotomy and root resection. In Case 1, the data obtained from preoperative CT scan and cast scan were transferred to a surgical planning software. The surgical template was printed using a 3D printer. Using the template, osteotomy and root?end resection were precisely carried out. In Case 2, after CBCT imaging, data were transferred to stereolithography and a 3D model was fabricated. With the help of the 3D model, a template was fabricated using tray material. This guided surgical template minimized the extent of osteotomy and enabled precise targeting of the apex. In Case 3, a preoperative CT scan aided in the fabrication of a surgical 3D template. The template assisted in the precise removal of the overlying cortical bone.

16.
Article in Spanish | LILACS | ID: biblio-1431959

ABSTRACT

La tecnología de fabricación aditiva o impresión 3D se ha posicionado como una herramienta transversal y de uso creciente en el mundo productivo y científico que ha otorgado la posibilidad de diseñar y crear elementos y modelos de diversa complejidad. En el área biomédica ha presentado un aumento significativo de sus aplicaciones a través del tiempo, actualmente teniendo relevancia en ámbitos como el planeamiento quirúrgico, la creación de prótesis, modelos anatómicos para educación y entrenamiento quirúrgico. Actualmente existen diversas dificultades que limitan la formación quirúrgica, especialmente en ciertas áreas de la otorrinolaringología como la cirugía de oído. El objetivo de la presente revisión narrativa fue actualizar los usos de la tecnología de impresión 3D para la creación de modelos para entrenamiento quirúrgico en otorrinolaringología, destacando sus potenciales usos en otología, rinología, cirugía de base de cráneo y vía aérea.


Additive manufacturing technology or 3D printing has positioned itself as a cross-cutting tool of increasing use in the productive and scientific world that has given the possibility of designing and creating different elements and models of varying complexity. In the biomedical area, it has presented a significant increase in its applications over time, currently having relevance in areas such as surgical planning, the creation of prostheses, anatomical models for education and surgical training. Currently there are various difficulties that limit surgical training, especially in certain areas of otorhinolaryngology such as ear surgery. The objective of this narrative review was to update the uses of 3D printing technology for the creation of models for surgical training in otorhinolaryngology, highlighting its potential uses in otology, rhinology, skull base and airway surgery.


Subject(s)
Otolaryngology/methods , Biocompatible Materials , Printing, Three-Dimensional , Otorhinolaryngologic Surgical Procedures
17.
Int. j. morphol ; 41(1): 73-78, feb. 2023. ilus
Article in English | LILACS | ID: biblio-1430533

ABSTRACT

SUMMARY: The study on cadavers, although considered fundamental in the teaching of human anatomy, is limited in several universities, mainly due to the acquisition and manipulation of cadaveric material. Throughout history, several artificial anatomical models have been used to complement the real anatomical pieces. The present study offers a new alternative: the making of three-dimensional models from Computed Tomography (3D-CT) patient image acquisition. CT images from the USP University Hospital database were used. Patients underwent examinations for reasons other than the present study and were anonymized to maintain confidentiality. The CT slices obtained in thin cross-sections (approximately 1.0 mm thick) were converted into three-dimensional images by a technique named Volume Rendering for visualization of soft tissue and bone. The reconstructions were then converted to an STL (Standard Triangle Language) model and printed through two printers (LONGER LK4 Pro® and Sethi S3®), using PLA and ABS filaments. The 3D impressions of the thigh and leg muscles obtained better visual quality, being able to readily identify the local musculature. The images of the face, heart, and head bones, although easily identifiable, although seemed to present lower quality aesthetic results. This pilot study may be one of the first to perform 3D impressions of images from CT to visualize the musculature in Brazil and may become an additional tool for teaching.


El estudio en cadáveres, a pesar de considerarse un aspecto fundamental en la enseñanza de la anatomía humana, se encuentra limitado en varias universidades, principalmente por la adquisición y manipulación de material cadavérico. A lo largo de la historia se han utilizado varios modelos anatómicos artificiales para complementar las piezas anatómicas reales. El presente estudio ofrece una nueva alternativa: la elaboración de modelos tridimensionales a partir de la adquisición de imágenes de pacientes por Tomografía Computarizada (3D-CT). Se utilizaron imágenes de TC de la base de datos del Hospital Universitario de la USP. Los pacientes se sometieron a exámenes por razones distintas al presente estudio y fueron anonimizados para mantener la confidencialidad. Los cortes de TC obtenidos en secciones transversales delgadas (aproximadamente 1,0 mm de grosor) se convirtieron en imágenes tridimensionales mediante una técnica denominada Volume Rendering para la visualización de tejido blando y hueso. Luego, las reconstrucciones se convirtieron a un modelo STL (Standard Triangle Language) y se imprimieron a través de dos impresoras (LONGER LK4 Pro® y Sethi S3®), utilizando filamentos PLA y ABS. Se obtuvo una mejor calidad visual de las impresiones 3D de los músculos del muslo y la pierna, pudiendo identificar fácilmente la musculatura local. Las imágenes de la cara, el corazón y los huesos de la cabeza, aunque fácilmente identificables, parecían presentar resultados estéticos de menor calidad. Este estudio piloto puede ser uno de los primeros en realizar impresiones 3D de imágenes de TC para visualizar la musculatura y podría ser en una herramienta adicional para la enseñanza.


Subject(s)
Humans , Tomography, X-Ray Computed , Printing, Three-Dimensional , Anatomy/education , Models, Anatomic
18.
China Journal of Orthopaedics and Traumatology ; (12): 849-853, 2023.
Article in Chinese | WPRIM | ID: wpr-1009148

ABSTRACT

OBJECTIVE@#To analyze the important effect of 3D printing personalized lumbar support on lumbar pain and lumbar function in patients with lumbar disc herniation.@*METHODS@#From October 2018 to May 2021, 60 patients initially diagnosed with lumbar disc herniation were selected and divided into an observation group and a control group, with 30 patients in each group. Among them, there were 18 males and 12 females in the observation group;the age ranged from 24 to 56 years old, with an average of (45.23±6.07) years old. The course of disease ranged from 1 to 24 months, with an average of(6.25±0.82) months, and rehabilitation treatment was carried out by wearing 3D printed personalized lumbar support. There were 19 males and 11 females in the control group;the age ranged from 25 to 57 years old, with an average of (42.78±7.58) years old. The course of disease ranged from 1 to 24 months, with an average of (6.72±1.36) months, and rehabilitation treatment is carried out by wearing traditional lumbar protective equipment. The Japanese Orthopaedic Association (JOA) scores, lumbar Oswestry dysfunction index (ODI) and visual analogue scale (VAS) were evaluated and compared between the two groups before and 1 course after treatment (3 weeks).@*RESULTS@#There was no statistically significant difference in JOA, ODI, and VAS between two groups before treatment (P>0.05). After one course of treatment (3 weeks), JOA scores of both groups was increased compared to before treatment (P<0.05), while ODI and VAS decreased compared to before treatment (P<0.05). After treatment, JOA score of observation group was higher than that of control group (P<0.05), while ODI and VAS scores were lower than those of control group. No adverse events occurred in both groups.@*CONCLUSION@#The application of 3D printing personalized lumbar support can effectively alleviate the pain of patients with lumbar disc herniation and improve their lumbar function of patients.


Subject(s)
Female , Male , Humans , Young Adult , Adult , Middle Aged , Intervertebral Disc Displacement/surgery , Printing, Three-Dimensional , Technology , Orthopedics , Low Back Pain
19.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 970-977, 2023.
Article in Chinese | WPRIM | ID: wpr-1009010

ABSTRACT

OBJECTIVE@#To explore the design points of a three-dimensional (3D) printed customized cementless intercalary endoprosthesis with an intra-neck curved stem and to evaluate the key points and mid-term effectiveness of its application in the reconstruction of ultrashort bone segments in the proximal femur.@*METHODS@#Between October 2015 and January 2021, 17 patients underwent reconstruction with a 3D printed-customized cementless intercalary endoprosthesis with an intra-neck curved stem. There were 11 males and 6 females, the age ranged from 10 to 76 years, with an average of 30.1 years. There were 9 cases of osteosarcoma, 4 cases of Ewing sarcoma, 2 cases of chondrosarcoma, 1 case of liposarcoma, and 1 case of myofibroblastoma. The disease duration was 5-14 months, with an average of 9.5 months. Enneking staging included 16 cases of stage ⅡB and 1 case of stage ⅢB. The distances from the center of the femoral head to the body midline and the acetabular apex were measured preoperatively on X-ray images. Additionally, the distances from the tip of the intra-neck curved stem to the body midline and the acetabular apex were measured at immediate postoperatively and last follow-up. The neck-shaft angle was also measured preoperatively, at immediate postoperatively, and at last follow-up. The status of osseointegration at the bone-prosthesis interface and bone growth into the prosthesis surface were assessed by X-ray films, CT, and Tomosynthesis-Shimadzu metal artefact reduction technology (T-SMART). The survival status of the patients, presence of local recurrence or distant metastasis, and occurrence of postoperative complications were assessed. The recovery of lower limb function was evaluated pre- and post-operatively using the Musculoskeletal Tumor Society (MSTS) scoring system, and pain relief was evaluated using the visual analogue scale (VAS) scores.@*RESULTS@#The patient's femoral resection length was (163.1±57.5) mm, the remaining proximal femoral length was (69.6±9.3) mm, and the percentage of femoral resection length/total femoral length was 38.7%±14.6%. All 17 patients were followed up 25-86 months with an average of 58.1 months. During the follow-up, 1 patient died of lung metastasis at 46 months postoperatively, and the remaining 16 patients survived tumor-free. There was no complication such as periprosthetic infection, delayed incision healing, aseptic loosening, prosthesis fracture, or periprosthetic fracture. No evidence of micromotion or wear around the implanted stem of the prosthesis was detected in X-ray and T-SMART evaluations. There was no significant radiolucent lines, and radiographic evidence of bone ingrowth into the bone-prosthesis interface was observed in all stems. There was no significant difference in the distance from the tip of the curved stem to the body midline and the apex of the acetabulum at immediate postoperatively and last follow-up compared with the distance from the center of the femoral head to the body midline and the apex of the acetabulum before operation, respectively (P>0.05), and there was no significant difference in the above indexes between immediate postoperatively and last follow-up (P>0.05). The differences in the neck-shaft angle at various time points before and after operation were also not significant (P>0.05). At last follow-up, the MSTS score was 26.1±1.2 and the VAS score was 0.1±0.5, which were significantly improved when compared with those before operation [19.4±2.1 and 5.7±1.0, respectively] (t=14.735, P<0.001; t=21.301, P<0.001). At last follow-up, none of the patients walked with the aid of crutches or other walkers.@*CONCLUSION@#The 3D printed customized cementless intercalary endoprosthesis with an intra-neck curved stem is an effective method for reconstructing ultrashort bone segments in the proximal femur following malignant tumor resection. The operation is reliable, the postoperative lower limb function is satisfactory, and the incidence of complications is low.


Subject(s)
Female , Male , Humans , Child , Adolescent , Young Adult , Adult , Middle Aged , Aged , Femur/surgery , Lower Extremity , Bone-Implant Interface , Femur Head , Artificial Limbs
20.
Journal of Modern Urology ; (12): 287-291, 2023.
Article in Chinese | WPRIM | ID: wpr-1006076

ABSTRACT

【Objective】 To investigate the application value of three-dimensional printed guiding device in sacral neuromodulation in children. 【Methods】 A total of 17 patients admitted during Jan.2017 and Nov.2022 were divided into two groups: control group (n=8), using traditional method to locate sacral foramen for puncture; three-dimensional printed guiding device group (n=5), using three-dimensional printing technology to make individual guiding device for puncture. The clinical indexes of the two groups were evaluated, including puncture time, puncture numbers, intraoperative X-ray exposure times, postoperative evaluation time and second-stage conversion rate. The evaluation indexes of postoperative complications were wound bleeding, wound infection, wound rupture, electrode fracture, displacement or prolapse. 【Results】 In the control group, 1 case was diagnosed as bladder-bowel dysfunction, the remaining 7 were neurogenic bladder; in the three-dimensional printed guiding device group, all 9 cases were diagnosed as neurogenic bladder. The puncture time was shorter in the three-dimensional printed guiding device group than in the control group [85(70-90) min vs.138(133-208) min], the puncture numbers were fewer [15(12-20) vs.22(18-26)], and the X-ray exposure times were fewer [12(12-17) vs.19(16-23)] (all P<0.05). The initial stimulation voltage, postoperative evaluation time and second-stage conversion rate were not statistically significant. 【Conclusion】 Compared with the traditional method, the use of three-dimensional printed guiding device can reduce the puncture numbers and shorten the puncture time in the process of sacral neuromodulation in children.

SELECTION OF CITATIONS
SEARCH DETAIL