Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 399
Filter
1.
Article in Chinese | WPRIM | ID: wpr-1026322

ABSTRACT

Superb microvascular imaging(SMI)is a new kind of Doppler technology,being sensitive for displaying low-velocity microvascular blood flow in muscles,tendons,synovium,nerves and reflecting microcirculation changes,able to provide imaging evidences for diagnosing musculoskeletal system diseases,monitoring processes and evaluating therapeutic effect.The research progresses of SMI applicated in musculoskeletal diseases were reviewed in this article.

2.
Article in Chinese | WPRIM | ID: wpr-1024219

ABSTRACT

Objective:To investigate the therapeutic effect of sequential therapy with butylphthalein on acute cerebral infarction and mild-to-moderate increases in middle cerebral artery blood flow in patients.Methods:The clinical data of 92 patients with acute cerebral infarction and mild-to-moderate increases in middle cerebral artery blood flow who received treatment at the Xiaogan Hospital Affiliated to Wuhan University of Science and Technology from January 2018 to October 2021 were retrospectively analyzed. These patients were divided into a study group and a control group using a random number table method. The control group was given an intravenous infusion of butylphthalein sodium chloride injection, while the study group took oral butylphthalein soft capsules after intravenous infusion of butylphthalein sodium chloride injection. The baseline data, hemodynamics, neurological function, and clinical outcomes were compared between the two groups. At 90 days after treatment, the National Institutes of Health Stroke Scale (NIHSS), the Activity of Daily Living Scale (ADL), and the modified Rankin Scale (mRS) were used to evaluate clinical outcomes. Transcranial Doppler ultrasound (TCD) examination was performed to evaluate hemodynamic changes.Results:A total of 92 patients completed all the observation indices as required, including 48 patients in the study group and 44 patients in the control group. There were no significant differences in demographics, vascular risk factors, laboratory results, NIHSS score, ADL score, or arterial hemodynamics of the diseased brain between the two groups (all P > 0.05). At 90 days after treatment, the NIHSS score in the study group was significantly lower than that in the control group [(4.00 ± 1.95) points vs. (4.91 ± 2.08) points; t =-2.16, P = 0.033]. The ADL score in the study group was significantly higher than that in the control group [(82.71 ± 9.56) points vs. (76.25 ± 11.47) points; t = 2.94, P = 0.004]. The good rate of outcomes in the study group was significantly higher than that in the control group [70.83% (34/48) vs. 50.00% (22/44); χ2 = 4.18, P = 0.041]. There were significant differences in the peak systolic velocity [(152.33 ± 9.58) cm/s vs. (157.41 ± 11.77) cm/s; t = 2.27, P = 0.025] and the mean velocity [(90.00 ± 8.30) cm/s vs. (94.45 ± 9.07) cm/s; t = -2.46, P = 0.016] of the middle cerebral artery between the study and control groups. The difference in pulsitility index between the two groups was not statistically significant [(0.97 ± 1.06) vs. (1.01 ± 1.21); t = 1.69, P = 0.093]. Compared with the poor outcome group, patients in the good outcome group had lower NIHSS and ADL scores after discharge (both P < 0.001), and the proportion of patients who received sequential therapy with butylphthalein in the good outcome group was higher [(60.70% (34/56) vs. 38.90% (14/36); χ2 = 4.18, P = 0.041]. Conclusion:Sequential therapy with butylphthalein can reduce neurological deficits, promote neurological function recovery, improve the hemodynamics of diseased blood vessels, and greatly improve daily living activities in patients with acute cerebral infarction complicated by mild to moderate increases in middle cerebral artery blood flow.

3.
Article in Chinese | WPRIM | ID: wpr-1024242

ABSTRACT

Objective:To correlate serum Nesfatin-1, N-terminal pro-brain natriuretic peptide (NT-proBNP), and cystatin C (CysC) levels with myocardial enzymes and cardiac function in patients with acute ST-elevation myocardial infarction (STEMI).Methods:This is a case-control study. A total of 100 patients with acute STEMI who received treatment at Lishui People's Hospital from January 2020 to December 2022 were included in the STEMI group. An additional 80 healthy controls who concurrently received physical examinations in the same hospital were included in the control group. Serum levels of Nesfatin-1, NT-proBNP, CysC, creatine kinase-MB (CK-MB), and cardiac troponin I (cTnI) levels were determined in each group. Left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter (LVDD), and left ventricular end-systolic diameter (LVDS) were measured using color Doppler ultrasound. Correlation analysis was performed.Results:Serum Nesfatin-1 level in the STEMI group was (89.96 ± 15.25) ng/L, which was significantly lower than (226.36 ± 37.47) ng/L in the control group ( t = 33.15, P < 0.05). Serum levels of NT-proBNP and CysC in the STEMI group were (1 325.12 ± 378.48) ng/L and (1.37 ± 0.24) mg/L, which were significantly higher than (78.95 ± 13.42) ng/L and (0.79 ± 0.16) mg/L in the control group ( t = -29.42, -18.56, both P < 0.05). Serum CK-MB and cTnI levels in the STEMI group were (46.51 ± 12.14) U/L and (1.13 ± 0.25) U/L, respectively, which were significantly higher than (12.23 ± 4.01) U/L and (0.09 ± 0.02) U/L in the control group ( t = -24.06, -37.09, both P < 0.05). The LVEF in the STEMI group was (37.84 ± 5.45)%, which was significantly lower than (72.41 ± 4.26)% in the control group ( t = 46.49, P < 0.05). The LVDD and LVDS in the STEMI group were (40.92 ± 5.25) mm and (58.98 ± 6.25) mm, which were significantly higher than (19.86 ± 3.36) mm and (34.21 ± 4.38) mm in the control group ( t = -31.13, -30.03, both P < 0.05). Serum Nesfatin-1 level was positively correlated with LVEF ( r = 0.572), but it was negatively correlated with serum CK-MB and cTnI levels, LVDD, and LVDS ( r = -0.498, -0.617, -0.506, -0.534, all P < 0.05). Serum NT-proBNP and CysC levels were negatively correlated with LVEF ( r = -0.653, -0.607), but they were positively correlated with serum CK-MB and cTnI levels, LVDD, and LVDS ( r = 0.582, 0.526, 0.712, 0.565, 0.631, 0.578, 0.659, 0.635, all P < 0.05). Conclusion:Serum Nesfatin-1 levels decrease, while serum NT-proBNP and CysC levels increase in patients with acute STEMI. Serum Nesfatin-1, NT-proBNP, and CysC levels are closely related to myocardial enzymes and cardiac function.

4.
Article in Chinese | WPRIM | ID: wpr-1024265

ABSTRACT

Objective:To evaluate the qualitative and quantitative diagnostic value of transvaginal contrast-enhanced ultrasonography for benign and malignant adnexal masses.Methods:Forty-nine patients with adnexal masses detected by routine ultrasound examination at Wenzhou People's Hospital from January 2021 to December 2022 were included in this study. Initially, transvaginal two-dimensional ultrasound, two-dimensional ultrasound integrated with color Doppler, and contrast-enhanced ultrasonography were used to accurately classify the masses as benign or malignant. Using postoperative pathology as the gold standard, the qualitative diagnostic accuracy of various detection methods was compared. Subsequently, the receiver operating characteristic curve analysis was performed to assess the quantitative diagnostic accuracy of transvaginal contrast-enhanced ultrasonography-related parameters in distinguishing between benign and malignant adnexal masses.Results:Among the 49 patients, 10 were diagnosed with malignant tumors. The diagnostic accuracy of contrast-enhanced ultrasonography was 93.88% (46/49), with a sensitivity of 90.00% (9/10), a specificity of 94.87% (37/39), a positive predictive value of 81.82% (9/11), and a negative predictive value of 97.37% (37/38). The results of the diagnostic difference assessment (McNemar test) revealed that there was no significant difference between two-dimensional ultrasound ( χ2 = 0.37, P = 0.546), two-dimensional ultrasound combined with color Doppler ( χ2 = 0.17, P = 0.683), and contrast-enhanced ultrasonography ( χ2 = 0.00, P = 1.000), and the gold standard test results. The consistency assessment (Kappa test) revealed that the diagnostic results of contrast-enhanced ultrasonography exhibited the highest concordance with the gold standard, with a Kappa value of 0.82 ( P < 0.001). Furthermore, the receiver operating characteristic curve analysis indicated that the initial increase time, peak intensity, and mean transit time in contrast-enhanced ultrasonography demonstrated high quantitative diagnostic accuracy. The areas under the curve were 0.83, 0.82, and 0.84, respectively, and the diagnostic cutoff values were 17.30 s, 21.65 dB, and 92.60 seconds, respectively. Conclusion:Contrast-enhanced ultrasonography exhibits diagnostic value in the differential diagnosis of benign and malignant adnexal masses, both qualitatively and quantitatively. This method can provide valuable insights for further treatment.

5.
Chinese Journal of Medical Imaging ; (12): 1298-1303, 2023.
Article in Chinese | WPRIM | ID: wpr-1026334

ABSTRACT

Purpose To preliminarily establish a predictive model for assessing preterm birth in the first trimester via clinical history and multiple ultrasound parameters.Materials and Methods This study included 200 women in the first trimester of pregnancy from 6 to 8 weeks in the Affiliated Renhe Hospital of Three Gorges University from September 2020 to September 2021,and their clinical history,two-dimensional imaging data and cervical elastography data were collected.Logistic regression analysis,screening and assignment were performed to initially establish a clinical prediction model for evaluating preterm birth during the first trimester.Results Finally,41 pregnant women developed preterm birth(preterm birth group),and 159 pregnant women did not develop preterm birth(term group).History of miscarriage,history of preterm birth,uterocervical angle(UCA),A,and A1 were the independent risk factors for preterm birth via univariate analysis,and multivariate analysis was carried out to obtain the formula:Logit(P)=1.495×abortion history+1.060×A1+0.795×UCA+1.354×A-14.951,which had a good fit via Hosmer-Lemeshow goodness-of-fit test,and the diagnostic efficiency was 96.9%.Conclusion The early pregnancy prediction model can effectively predict the occurrence of preterm birth in pregnant women with singleton pregnancy.

6.
Chinese Journal of Neurology ; (12): 1270-1277, 2023.
Article in Chinese | WPRIM | ID: wpr-1029142

ABSTRACT

Objective:To analyze the clinical characteristics and management strategy of carotid web (CW)-related stroke and improve the understanding of CW.Methods:The clinical data of 6 patients with CW-related stroke treated at Xuanwu Hospital, Capital Medical University, from January 2018 to September 2022 were retrospectively analyzed. Relevant data included clinical manifestations, bronchial magnetic resonance imaging (MRI), CT angiography (CTA)/digital subtraction angiography (DSA), carotid ultrasonography, and transcranial color-coded Doppler sonography (TCCD). Treatments and follow-ups were also reported.Results:All 6 patients were middle-aged or young, without traditional risk factors for cerebrovascular disease. The male-to-female ratio was 2∶4. All patients had recurrent strokes, with a score of 2-4 on the National Institutes of Health Stroke Scale at the time of onset. Head MRI showed 5 patients with cerebral infarction in the middle cerebral artery supply area; 1 patient had no intracranial infarction. No significant stenosis of the vessels at the site of the CW was observed in any of the 6 patients. Four patients had ipsilateral stenosis or occlusion of the middle cerebral artery, 1 patient had microembolic signals in the middle cerebral artery, and 1 patient had no significant abnormalities in the intracranial artery. All 6 patients were initially diagnosed by ultrasound. Diagnoses were confirmed by CTA/DSA in 5 cases; the other patient did not show any significant abnormalities. All 6 patients underwent a carotid endarterectomy after a pathological examination to confirm the diagnosis. Postoperatively, regular antiplatelet aggregation and statin lipid-lowering therapies were administered. A follow-up of 0.5 to 5.2 years showed no stroke recurrence in any patient.Conclusions:CW-related stroke is a rare cause of cryptogenic stroke and has a high recurrence rate. For stroke patients who do not have traditional risk factors for cerebrovascular disease while repeatedly experiencing embolic events of the internal carotid artery system, attention should be paid to the combination of the carotid and cerebral arteries, and comprehensive hemodynamic characteristics should be checked for the presence of a CW. Carotid artery ultrasound and TCCD combined with other imaging methods can improve the detection rate of a CW. Simple antiplatelet aggregation therapy cannot effectively prevent stroke recurrence. For patients with confirmed CW-related cerebral infarction, surgical resection can be performed, and the treatment effect can be evaluated using ultrasonography.

7.
Article in Chinese | WPRIM | ID: wpr-991087

ABSTRACT

Objective:To investigate the clinical significance of color Doppler ultrasonography combined with detection of thyroid autoantibodies in the early diagnosis of thyroid cancer.Methods:A total of 108 patients with thyroid cancer who treated in Shaoxing Central Hospital Medical Community General Hospital from September 2019 to September 2021 were selected as the research group, and 108 patients with benign thyroid lesions during the same period were selected as the control group. The ultrasound examination results and the levels of serum thyroglobulin antibody (TgAb), thyroid peroxidase antibody (TPOAb) and thyroid receptor antibody (TRAb) were compared between the two groups. The relationship between the thyroid autoantibodies index and the early diagnosis of thyroid cancer were analyzed by Spearman correlation analysis; the value of early diagnosis by color Doppler ultrasonography combined with detection of thyroid autoantibodies were evaluated by the receiver operating characteristic (ROC) curve.Results:The main features of ultrasonic images in the research group were unclear edge, low echo, irregular shape, chaotic blood flow distribution, internal micro calcification, no envelope and blood flow resistance index ≥0.7. The sensitivity of ultrasonography for the diagnosis of thyroid cancer was 86.11% (93/108), the specificity was 87.18% (102/117) and the accuracy was 90.28% (195/216). The levels of serum TgAb, TPOAb and TRAb in the research group were higher than those in control group: (32.28 ± 2.85) kU/L vs. (21.96 ± 2.54) kU/L, (81.28 ± 7.32) kU/L vs. (51.53 ± 5.86) kU/L, (4.48 ± 1.25) U/L vs. (2.35 ± 0.63 ) U/L, there were statistical differences ( P<0.05). The levels of serum TgAb, TPOAb and TRAb in patients with lymph node metastasis were higher than those in the patients without lymph node metastasis: (36.28 ± 3.12) kU/L vs. (30.60 ± 2.54) kU/L, (93.51 ± 8.57) kU/L vs. (76.13 ± 6.62) kU/L, (5.73 ± 1.54) U/L vs. (3.95 ± 1.12) U/L, there were statistical differences ( P<0.05). The levels of serum TgAb, TPOAb and TRAb in patients with stage Ⅲ-Ⅳ were higher than those in the patients with stage Ⅰ-Ⅱ: (35.84 ± 3.28) kU/L vs. (29.74 ± 2.29) kU/L, (89.35 ± 8.16) kU/L vs. (75.52 ± 6.23) kU/L, (5.28 ± 1.49) U/L vs. (3.91 ± 1.25) U/L, there were statistical differences ( P<0.05). The results of Spearman correlation analysis showed that the levels of serum TgAb, TPOAb and TRAb were positively correlated with lymph node metastasis ( r = 0.758, 0.824, 0.695, P<0.05) and clinical stage of thyroid cancer ( r = 0.735, 0.796, 0.673, P<0.05). The results of ROC curve analysis showed that the area under the curve(AUC) of ultrasound examination combined with TgAb, TPOAb and TRAb for early diagnosis of thyroid cancer was 0.930, the sensitivity was 85.19%, and the specificity was 91.67%. The combined diagnostic value was better than single diagnosis. Conclusions:Ultrasound examination combined with serum TgAb, TPOAb and TRAb has high diagnostic value for early stage thyroid cancer, which is helpful to clinically clarify the condition, and provides a reliable basis for preoperative diagnosis and targeted individualized treatment plan.

8.
Article in Chinese | WPRIM | ID: wpr-991772

ABSTRACT

Objective:To investigate the clinical value of high-frequency ultrasound combined with virtual touch tissue imaging and quantification in the assessment of limb muscle tension after stroke in patients.Methods:A total of 31 patients with stroke who received treatment in Wenzhou Hospital of Integrated Traditional Chinese and Western Medicine from January 2020 to May 2022 and 41 healthy controls who concurrently underwent physical examination in the same hospital were included in this study. Before rehabilitation treatment, the shear wave velocity of the main muscle groups of the limbs was measured using virtual touch tissue imaging and quantification in all participants. The shear wave velocity of the main muscle groups was compared between the affected and healthy sides of patients between two sides of patients. The patient's muscle tension was evaluated using the modified Ashworth Scale. The shear wave velocity of the affected muscle groups in patients was correlated with the modified Ashworth Scale score.Results:There were no significant differences in the shear wave velocities of the main muscle groups of upper (biceps, flexor digitorum sublimis, flexor digitorum profundus) and lower [medial head of the gastrocnemius muscle, lateral head of the gastrocnemius muscle] limbs between the left [(2.46 ± 0.26) m/s, (2.81 ± 0.50) m/s, (2.96 ± 0.31) m/s, (2.49 ± 0.44) m/s, (2.21 ± 0.20) m/s] and right [(2.42 ± 0.29) m/s, (2.80 ± 0.47) m/s, (3.02 ± 0.36) m/s, (2.54 ± 0.37) m/s, (2.18 ± 0.17) m/s] sides in healthy controls ( t = 0.78, 0.04, 0.83, 0.58, 1.15, P = 0.435, 0.967, 0.405, 0.558, 0.216). The shear wave velocities of the main muscle groups of upper [flexor digitorum sublimis (3.74 ± 0.67) m/s, flexor digitorum profundus (3.64 ± 0.60) m/s), biceps (3.63 ± 0.64) m/s] and lower [medial head of the gastrocnemius muscle (3.28 ± 0.61) m/s, lateral head of the gastrocnemius muscle (2.90 ± 0.37) m/s] limbs on the affected side in patients with stroke were significantly higher than (2.56 ± 0.40) m/s, (2.67 ± 0.38) m/s, (2.78 ± 0.41) m/s, (2.30 ± 0.21) m/s, (2.25 ± 0.23) m/s on the healthy side ( t = 11.81, 8.21, 8.75, 8.91, 10.43, all P < 0.001). The shear wave velocities of the main muscle groups of the upper (flexor digitorum sublimis, flexor digitorum profundus, and biceps) and lower (medial head of the gastrocnemius muscle and lateral head of the gastrocnemius muscle) limbs were positively correlated with the modified Ashworth Scale score ( r = 0.77, 0.70, 0.72, 0.74, 0.78, P = 0.007, 0.029, 0.021, 0.016, 0.001). Conclusion:Monitoring the shear wave velocities of the main muscle groups of the upper and lower limbs using high-frequency ultrasound combined with virtual touch tissue imaging and quantification can effectively reflect the change in limb muscle tension of patients with stroke, which is highly valuable for evaluating rehabilitation efficacy and prognosis in patients with stroke.

9.
Article in Chinese | WPRIM | ID: wpr-991781

ABSTRACT

Objective:To investigate the value of ultrasound findings in the diagnosis of lower extremity arterial disease in patients with type 2 diabetes mellitus and correlate it with clinical factors.Methods:A total of 535 patients with type 2 diabetes mellitus who received treatment in Taiyuan Second People's Hospital from January 2016 to June 2019 underwent color Doppler ultrasound examination (T2DM group). Vascular inner diameter, intima-media thickness, atherosclerotic plaque formation, lumen stenosis or occlusion, and hemodynamic characteristics were determined in patients with type2 diabetes mellitus compared with those in 107 patients with non-type 2 diabetes mellitus (non-T2DM group). These parameters were correlated with the course of the disease, blood glucose level, concomitant hypertension or not, and clinical Wagner grade.Results:The incidences of intima-media thickening, atherosclerotic plaque, stenosis, and occlusion of lower extremity arteries were 69.9%, 89.0%, 77.0% and 11.6% respectively, in the T2DM group, which were significantly higher than 41.1%, 78.5%, 72.0%, and 1.9% respectively in the non-T2DM group ( χ2 = 32.52, P < 0.001; χ2 = 8.76, P = 0.003; χ2 = 27.77, P < 0.001). With the prolongation of the course of T2DM, the incidence of arterial lesions in the lower extremities increased ( P < 0.001). The incidences of intima-media thickening, atherosclerotic plaque, stenosis, and occlusion of lower extremity arteries were significantly greater in the poor blood glucose control group and non-hypertension group compared with the good blood glucose control group and hypertension group (all P < 0.05). The degree of lower extremity arterial stenosis in T2DM patients was related to Wagner's grade. As the degree of stenosis increased, Wagner's grade increased correspondingly and significantly ( P < 0.001). Conclusion:Color Doppler ultrasound examination has an important value in evaluating lower extremity arterial lesions in patients with T2DM. The degree of arterial lesions in the lower extremities of T2DM patients is correlated with the course of the disease, blood glucose levels, concomitant hypertension, and clinical Wagner grade. Color Doppler ultrasound examination has an important clinical significance in evaluating the degree of vascular lesions and guiding early interventions in the clinic.

10.
Article in Chinese | WPRIM | ID: wpr-991867

ABSTRACT

Objective:To explore the application value of uterine artery blood flow ultrasound parameters in evaluating the prognosis of threatened abortion during early pregnancy.Methods:In this non-randomized controlled prospective clinical study, 108 women with threatened abortion during early pregnancy (6-12 weeks of pregnancy) who received treatment in the Health Community Group of Yuhuan Second People's Hospital from July 2021 to December 2022 were included in the observation group. An additional 108 healthy women who were at the early stage of pregnancy were selected for the control group. Color Doppler ultrasound was performed in both groups to measure the ultrasonic parameters of uterine artery blood flow (peak systolic/end diastolic flow velocity, resistance index, pulsatility index) and compare their differences. The pregnant women in the observation group were followed up until 28 weeks of gestation, and their prognosis was analyzed. The pregnant women who had successfully insured their babies were included in the good prognosis group, and the pregnant women who had aborted their babies were included in the poor prognosis group. The ultrasonic parameters of uterine artery blood flow in the two groups were compared. Logistic regression analysis was used to analyze the correlation between ultrasound parameters of uterine artery blood flow and poor prognosis.Results:In the observation group, the systolic peak/end diastolic flow velocity, resistance index, and pulsatility index on the left side were (6.46 ± 1.71), (0.97 ± 0.30), (2.72 ± 0.89), respectively, and they were (6.49 ± 1.70), (0.96 ± 0.32), (2.70 ± 0.91) respectively on the right side, which were significantly greater than (3.90 ± 1.02), (0.64 ± 0.17), (1.36 ± 0.54), (3.91 ± 1.04), (0.62 ± 0.18), (1.35 ± 0.52) in the control group ( t = 13.36, 9.95, 13.58, 13.45, 9.62, 13.39, all P < 0.001). Twenty-eight-week follow-up results showed that 72 women (66.67%) in the observation group had successfully insured their babies and 36 women (33.33%) had aborted their babies. In the good prognosis group, the systolic peak/end diastolic flow velocity, resistance index, and pulsatile index were (7.95 ± 1.89), (1.22 ± 0.36), (3.06 ± 0.95) on the left side, and they were (7.45 ± 1.94), (1.24 ± 0.37), and (3.03 ± 0.96) on the right side, which were significantly greater than (4.72 ± 1.27), (0.77 ± 0.24), (1.74 ± 0.69), (4.74 ± 1.32), (0.75 ± 0.25), (1.77 ± 0.70) in the poor prognosis group ( t = 10.53, 7.73, 8.23, 8.55, 8.14, 7.76, all P < 0.001). Logistic regression analysis showed that peak systolic/end diastolic flow velocity and resistance index were risk factors for poor prognosis of threatened abortion during early pregnancy, while the pulsatility index had no significant correlation with poor prognosis of threatened abortion during early pregnancy. Conclusion:Uterine artery blood flow ultrasound parameters have a certain predictive value for the prognosis evaluation of threatened abortion during early pregnancy, which can provide an important reference for clinical fetal protection treatment and benefit the prognosis of pregnant women.

11.
Journal of Chinese Physician ; (12): 714-718, 2023.
Article in Chinese | WPRIM | ID: wpr-992367

ABSTRACT

Objective:To evaluate the diagnostic evaluation process and the effectiveness and safety of intracavitary therapy for pelvic congestion syndrome (PCS).Methods:A retrospective analysis was conducted on 38 patients admitted to Beijing Shijitan Hospital affiliated to Capital Medical University from March 2019 to February 2022. Combined with the patient′s symptoms, PCS was diagnosed by color Doppler ultrasound, computed tomography venography (CTV), and venography. The ovarian vein was embolized with controllable spring coil and polydocanol foam sclerosing agent. The patients were followed up 1, 3 and 6 months after operation.Results:The total surgical success rate of 38 patients was 100%, and the incidence of complications was 5.3%(2/38); Spring coils (2.8±0.3)per person; The dosage of hardener was (7.0±2.1)ml/person. The improvement rate of patient symptoms was 97.4%(37/38); After 1, 3, and 6 months of surgery, color Doppler ultrasound was reexamined and no recanalization was observed in the embolized ovarian veins; The diameter of the parauterine vein was (2.8±0.5)mm, which was significantly lower than the preoperative (7.5±1.9)mm ( P<0.05); The Visual Analogue Scale (VAS) score was significantly lower than the preoperative score [(2.12±1.87)points vs (7.58±0.82)points, P<0.001]. Conclusions:Process based assessment is helpful in identifying and diagnosing PCS patients who urgently need treatment; Endovascular treatment based on embolization of ovarian vein with controllable spring coil and foam sclerosing agent is minimally invasive, safe and effective.

12.
Journal of Chinese Physician ; (12): 1121-1124, 2023.
Article in Chinese | WPRIM | ID: wpr-992428

ABSTRACT

Prostate cancer is the most common malignant tumor in the male urogenital system. Transrectal ultrasound has become a commonly used method for the diagnosis and biopsy of prostate cancer due to its simplicity, economy, and non radiation. This article will discuss the current application status and progress of traditional transrectal ultrasound, color doppler ultrasound, ultrasound imaging, elastic ultrasound, micro ultrasound, tissue scanning, and multimodal ultrasound in the diagnosis of prostate cancer.

13.
Article in Chinese | WPRIM | ID: wpr-992807

ABSTRACT

Objective:To construct a nomogram for predicting the occurrence of renal allograft rejection based on the combination of multimodal ultrasound features and clinical data.Methods:The ultrasound findings and clinical characteristics of 102 patients with transplanted kidneys who underwent renal biopsy in the General Hospital of Eastern Theater Command from January 2021 to March 2022 were analyzed retrospectively. Patients were divided into rejection group and nephropathy group according to Banff transplant kidney pathological diagnostic criteria (2017 edition). Multivariate Logistic regression was used to screen independent predictors related to the status of rejection, and nomograms were drawn based on the independent predictors. The internal validation of the nomogram was carried out by Bootstrap method, and the ROC curve and calibration curve were utilized to evaluate the diagnostic efficacy of the nomogram.Results:Blood urea nitrogen concentration, renal aortic resistance index, absolute time to peak and cortical echo were independent predictors of rejection( OR=1.073, 1.078, 0.843, 0.205; all P<0.05). Incorporating blood urea nitrogen concentration, renal aortic resistance index, absolute peak time and cortical echo, the nomogram was constructed. The AUC of the predictive model was 0.814(95% CI=0.722-0.905) and the cutoff value was 0.67(corresponding to a total score of about 157 points). Both internal verification (AUC=0.788) and calibration curve demonstrated the clinical usefulness of the nomogram. Conclusions:The nomogram for predicting the occurrence of rejection in renal allograft patients based on multimodal ultrasound features and clinical data can guide the individualized treatment of patients with renal dysfunction.

14.
Article in Chinese | WPRIM | ID: wpr-992837

ABSTRACT

Objective:To evaluate the autogenous arteriovenous fistula(AVF) insufficiency by ultrasound monitoring of brachial artery resistance index(RI).Methods:The brachial artery RI and blood flow volume(FV) data of 828 patients who underwent color-Doppler ultrasound detection after AVF in the General Hospital of Western Theater Command from January 2019 to June 2021 were retrospectively analyzed. The patients were grouped according to the adequacy of clinical dialysis, including 668 patients in the group with normal AVF function and 160 patients in the group with insufficient AVF function. The general information and ultrasonic measurement parameters were compared between the two groups. The correlation between brachial artery FV and RI was analyzed. The evaluation of brachial artery flow RI for AVF insufficiency was analyzed by ROC curve.Results:There were statistically significant differences between the two groups in brachial artery RI and FV(both P<0.001). The results of Pearson correlation analysis showed that brachial artery FV was negatively correlated to RI ( r=-0.657, P<0.001). The area under ROC curve for assessing AVF function by brachial artery RI was 0.970, with 95% CI was 0.955-0.986, the optimal cut-off value was 0.665, and the sensitivity and specificity were 0.888 and 0.955, respectively. Conclusions:Brachial artery RI in patients with AVF insufficiency is significantly higher than that in patients with normal AVF function. The optimal cutoff value of brachial artery RI can be used as an evaluation parameter for rapid screening of AVF function.

15.
Chinese Journal of Orthopaedics ; (12): 391-398, 2023.
Article in Chinese | WPRIM | ID: wpr-993454

ABSTRACT

Objective:To explore the clinical value of super micro vascular imaging (SMI) in evaluating the microvascular perfusion of diabetes foot treated by tibial transverse bone transport.Methods:A retrospective study of 18 diabetic foot patients who underwent tibial transverse bone transport in the Second Hospital of Shanxi Medical University from May 2019 to December 2021 were analysed, including 12 males and 6 females, with an average age of 64.89±14.34 years (range, 30-90 years). All patients had varying degrees of foot ulcer. Before and after the operation, the blood vessels of the patient's lower leg and foot were examined. The display rate of low-velocity blood flow was compared between color Doppler flow imaging (CDFI) and SMI; the blood flow and vascular index at the beginning of the first dorsal metatarsal artery before and after operation under SMI were compared; the number and length of new blood vessels were also compared before and after operation.Results:All patients were followed up for at least 2 months. CDFI blood flow display rate was 73.6% (106/144), and SMI blood flow display rate was 80.6% (116/144), the difference was statistically significant (χ 2=4.68, P=0.031). Under SMI, the blood flow at the beginning of the first dorsal metatarsal artery on the affected side was measured before operation 3.38 (1.33, 7.56) ml/min, 1 week after operation 4.19(2.84, 11.48) ml/min and 1 month after operation 3.72 (2.52, 11.40) ml/min, with statistically significant difference (χ 2=9.46, P=0.009). There were statistically significant differences in blood flow at 1 week and 1 month after operation compared with that before operation ( P=0.033, P=0.003). The vascular index at the beginning of the first dorsal metatarsal artery on the affected side was 3.84±3.60, 6.51±4.92 and 6.82±5.36 before operation, 1 week and 1 month after operation, respectively, and the differences were statistically significant( F=4.35, P=0.031). The vascular index in the first week after operation was significantly higher than that before operation ( P=0.026). Up to the last follow-up, the number of new collaterals in 18 patients was 4.5 (2, 8), which was significantly different from 1 (0, 2) before operation ( Z=-3.57, P=0.001). In total, the length of 18 new blood vessels in 9 patients was longer than that before operation, and the establishment of grade 2 and grade 3 branches were observed in 5 patients. The superficial subcutaneous vessels were showed more clarity than that before surgery, and there was collateral circulation on the opposite side. Conclusion:SMI objectively reflects the changes of hemodynamics and microcirculation of patients after tibial transverse bone transport, and helps clinical preliminary predict the prognosis of patients and adjust individual treatment plan according to blood perfusion in time.

16.
Article in Chinese | WPRIM | ID: wpr-995149

ABSTRACT

Objective:To explore the value of jellyfish sign, an abnormal ultrasonographic sign, in predicting adverse perinatal outcomes of women with complete placenta previa combined with placenta accreta spectrum disorders (PAS).Methods:This retrospective study analyzed the ultrasound images of 72 singleton gravidas, diagnosed with complete placenta previa combined with PAS, who underwent cesarean section at the First Affiliated Hospital of Nanjing Medical University between January 2020 and February 2023. Based on the presence and absence of the jellyfish sign in ultrasound images, these gravidas were divided into the jellyfish-sign group (15 cases, 20.8%) and the non-jellyfish-sign group (57 cases, 79.2%). The clinical data and perinatal outcomes of the two groups were analyzed. The adverse perinatal outcomes encompassed conditions such as abdominal aorta balloon block, uterine artery embolism, hysterectomy, postpartum hemorrhage, and neonatal intensive care unit (NICU) admission of their neonates. Statistical analysis was performed using two independent samples t-test, the Mann-Whitney U test and the Chi-square (or Fisher's exact) test. Results:(1) The jellyfish-sign group exhibited a higher parity [(1.6±0.7) times vs (1.2±0.6) times, t=2.01] and higher prenatal scores of placenta accreta [(12.3±1.5) scores vs (8.6±2.9) scores, t=6.59] than those in the non-jellyfish-sign group (both P<0.05). Among the 57 cases in the non-jellyfish-sign group, there were 14 cases of placenta creta (24.6%), 40 cases of placenta increta (70.2%), and three cases of placenta percreta (5.3%). Among the 15 cases in the jellyfish-sign group, nine cases were diagnosed with placenta increta, six with placenta percreta, and none with placenta creta. The difference in distribution between the two groups was statistically significant (Fisher's exact test, P<0.001). (2) Intraoperative blood loss [(for those who accepted abdominal aorta balloon block, 1 973±1 057) ml vs (1 211±576) ml, t=2.55], red blood cells transfused [4.0 U (2.0-23.0 U) vs 2.5 U (0.0-11.0 U), Z=-2.53], postoperative hospitalization time [(9.7±2.4) vs (7.5±2.2) d, t=3.36], the incidence of abdominal aorta balloon block [15/15 vs 38.6% (22/57), χ2=17.92], uterine artery embolism [for those who accepted abdominal aorta balloon block, 3/15 vs 1.8% (1/57), Fisher's exact test], and requiring blood transfusion [15/15 vs 63.2% (36/57), Fisher's exact test] were higher in the jellyfish-sign group than those in the non-jellyfish-sign group. However, the non-jellyfish-sign group had lower gestational age at delivery [(33.6±1.5) weeks vs (35.2±1.8) weeks, t=-3.24], and lower neonatal Apgar score at 1 min and 5 min [1 min: 8 scores (3-10 scores) vs 9 scores (4-10 scores), Z=-2.46; 5 min: 9 scores (7-10 scores) vs 10 scores (6-10 scores), Z=-2.02] (all P<0.05). There were no significant differences in emergency surgery rate, 24 h postoperative blood loss, neonatal birth weight, and proportion of NICU admission between the two groups. Additionally, no cases of hysterectomy or death were observed in the two groups. Conclusions:Ultrasound examination revealing jellyfish signs in patients with complete placenta previa and PAS is associated with an increased likelihood of adverse perinatal outcomes. Consequently, the management of these patients should be given greater attention.

17.
Article in Chinese | WPRIM | ID: wpr-1024137

ABSTRACT

Objective:To analyze the value of color Doppler ultrasound examination in the diagnosis of breast cancer with microcalcifications.Methods:A total of 145 patients with breast cancer who received treatment in Weihai Central Hospital from August 2016 to August 2020 were included in this study. All of these patients underwent X-ray photography, ultrasound examination, and pathological examination. They were divided into ultrasound results-positive group and ultrasound results-negative group. Univariate and multivariate logistic analyses were performed to analyze the factors related to sensitivity of ultrasound examination for identifying breast cancer with microcalcifications.Results:Among 145 patients with breast cancer with microcalcifications, 80 patients (55.17%) had ductal carcinoma in situ and 65 cases (44.83%) had invasive carcinoma. Histological grade I, II, III carcinoma and carcinoma of unknown grading were found in 14 patients (9.66%), 91 patients (62.76%), 37 patients (25.52%), and 3 patients (2.07%), respectively. The sensitivity of color Doppler ultrasound in identifying breast cancer with microcalcifications was 81.38%. The results of logistic regression analysis showed that pathological type invasive carcinoma, the size of microcalcification > 2 cm, and the shape of microcalcification being polymorphic were the factors that affect the sensitivity of color Doppler ultrasound for identifying breast cancer with microcalcifications. The tumor size measured by pathology, X-ray photography, and ultrasound was (2.02 ± 0.45) cm, (2.45 ± 0.36) cm, and (2.14 ± 0.38) cm, respectively. There was a significant correlation in tumor size between X-ray photography and ultrasound measurement results and pathological measurement results ( r = 0.58, 0.73, both P < 0.05). The tumor size measured by ultrasound, compared with that measured by X-ray photography, was closer to pathological measurement result. Conclusion:Color Doppler ultrasound has a high sensitivity in identifying breast cancer with microcalcifications, but it is greatly affected by pathological type, microcalcification morphology and microcalcification size. The tumor sizes measured by color Doppler ultrasound and X-ray photography are slightly larger than pathological measurement results, but the tumor sizes measured by color Doppler ultrasound are closer to the pathological measurement results.

18.
Article in Chinese | WPRIM | ID: wpr-1024157

ABSTRACT

Objective:To investigate the effectiveness of vascular ultrasound examination in the diagnosis of subclavian artery stenosis (ASA) combined with vertebral artery stenosis (VSA) and its effects on different types of steal syndrome.Methods:Seventy patients with ASA combined with VSA who received treatment in Zhuji People's Hospital from February 2018 to May 2022 were included in this study. All patients underwent digital subtraction angiography (DSA) and a vascular ultrasound examination. Taking the DSA examination results as the reference standard, the accuracy of vascular ultrasound examination in the classification of ASA and VSA and its consistency with the DSA diagnosis results were evaluated. The detection rate of subclavian artery steal was compared between DSA and vascular ultrasound examination was compared. The correlation between the degree of ASA and the severity of subclavian artery steal was analyzed.Results:The accuracy of vascular ultrasound examination in the diagnosis of different degrees of ASA was 84.62% (11/13), 89.66% (26/29), 95.24% (20/21), and 100.00% (7/7), respectively. The Kappa value, indicating the consistency of vascular ultrasound examination and DSA restults in the diagnosis of ASA, was 0.858 ( P < 0.05). There was a significant difference in the type of subclavian artery steal among patients with different degrees of ASA ( χ2 = 50.71, P < 0.01). The severity of subclavian artery steal was highly positively correlated with the severity of ASA ( r = 0.71, P < 0.001). Conclusion:Vascular ultrasound examination has high diagnostic accuracy for different degrees of ASA and VSA, has high consistency with DSA results, and can increase the detection rate of subclavian artery steal. Vascular ultrasound examination has certain advantages in the early screening and condition monitoring of ASA, VSA, and subclavian artery steal.

19.
Article in Chinese | WPRIM | ID: wpr-1024177

ABSTRACT

Objective:To analyze the predictive value of uterine artery ultrasound examination during early pregnancy for gestational hypertension.Methods:A total of 100 patients with gestational hypertension who received treatment in Jinhua Maternal and Child Health Hospital from January 2020 to January 2022 were included in the observation group. An additional 100 healthy pregnant women who concurrently underwent routine physical examination were included in the control group. Using the case-control study method, both groups underwent uterine artery ultrasound examination during early (7-11 gestational weeks and 6 days) pregnancy. Uterine artery ultrasound data [resistance index (RI), pulsatility index (PI), and arterial peak systolic/diastolic flow velocity (S/D)] were determined and compared between the two groups. Patients in the observation group were followed up to delivery, and the adverse maternal and infant outcomes were analyzed. Those with adverse maternal and infant outcomes were included in the poor prognosis group, while those without adverse maternal and infant outcomes were included in the good prognosis group. The ultrasound data of uterine arteries were compared between the two groups. Logistic regression analysis was performed to analyze the correlation between uterine artery ultrasound data and adverse maternal and infant outcomes.Results:The RI, PI, and S/D of pregnant women in the observation group were (0.56 ± 0.15), (1.29 ± 0.34), (3.79 ± 0.32), respectively, which were significantly greater than (0.41 ± 0.12), (0.72 ± 0.21), (2.88 ± 0.25) in the control group ( t = 7.80, 14.26, 22.40, all P < 0.001). In the observation group, there were 11 cases of premature birth, 2 cases of miscarriage, 4 cases of postpartum hemorrhage, 4 cases of premature rupture of amniotic fluid, 5 cases of fetal distress, 3 cases of neonatal asphyxia, and 1 case of neonatal growth restriction. The total incidence of adverse maternal and infant outcomes was 30.0% (30/100). The RI, PI, and S/D of pregnant women in the poor prognosis group were (0.65 ± 0.19), (1.37 ± 0.40), and (4.06 ± 0.37), respectively, which were significantly higher than (0.50 ± 0.13), (1.16 ± 0.31), and (3.35 ± 0.29) in the good prognosis group ( t = 4.57, 2.83, 10.30, all P < 0.05). Logistic regression analysis was performed using adverse maternal and infant outcomes as dependent variables and RI, PI, and S/D as independent variables. Logistic regression analysis results showed that RI, PI, and S/D were the risk factors for adverse maternal and infant outcomes ( OR = 2.760, 1.832, 3.241, 95% CI = 1.209-5.985, 1.001-2.971, 2.134-10.159). Conclusion:Uterine artery ultrasound examination during early pregnancy has a certain reference value for predicting gestational hypertension and evaluating adverse maternal and infant outcomes. It can provide a reliable basis for early diagnosis and treatment of gestational hypertension and is beneficial for patient prognosis.

20.
Journal of Clinical Hepatology ; (12): 2651-2656, 2023.
Article in Chinese | WPRIM | ID: wpr-998822

ABSTRACT

ObjectiveThis article aims to investigate the clinical features of portal biliopathy (PB) patients, in order to improve the understanding of PB. MethodsClinical data were collected from 22 patients who were diagnosed with PB in recent years in The First Hospital of Jilin University, and an analysis was performed for their clinical manifestations, liver function, abdominal color Doppler ultrasound, abdominal CT, and hepatobiliary magnetic resonance imaging. The imaging manifestations of biliary tract abnormalities were described, as well as the type of collateral circulation and the location of thrombosis. ResultsAs for the initial symptom in these 22 patients, three were 11 patients with gastrointestinal bleeding, 5 with abdominal distension, 3 with abdominal pain, 1 with fever, 1 with abdominal discomfort, and 1 with gingival bleeding. There were 3 patients with an increase in aspartate aminotransferase, 4 with an increase in alanine aminotransferase, 4 with an increase in gamma-glutamyl transpeptidase, 7 with an increase in alkaline phosphatase, 8 with a reduction in cholinesterase, 9 with a reduction in albumin, 2 with an increase in globulin, and 5 with an increase in total bilirubin. Among the 22 patients, 20 had cavernous transformation of the portal vein, and 2 had portal vein thrombosis without cavernous transformation. All 22 patients had bile duct abnormalities, among whom 2 had extrahepatic bile duct abnormalities alone, 12 had intrahepatic bile duct dilatation alone, and 8 had dilatation of both intrahepatic and extrahepatic bile ducts. Varices at different sites were observed in 20 patients, among whom 19 had esophageal and gastric varices and 1 had peri-gallbladder varices, and no varices was observed in the superior mesenteric vein or the splenic vein. ConclusionThere are no typical clinical symptoms and changes in liver function parameters in patients with PB, but radiological examination may show dilatation, stenosis, or malformation of the bile ducts at different parts. Therefore, it is necessary to expand the sample size to further explore the diagnosis and treatment of PB.

SELECTION OF CITATIONS
SEARCH DETAIL