Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 346
Filter
1.
International Eye Science ; (12): 88-92, 2024.
Article in Chinese | WPRIM | ID: wpr-1003512

ABSTRACT

As a highly prevalent global condition, myopia significantly impacts the ocular health of young individuals in China. Orthokeratology lens, as a rigid corneal contact lens, has demonstrated effective control over the progression of myopia; however, its mechanism of action remains incompletely elucidated. As one of the factors influencing visual acuity, higher-order aberrations will undergo marked changes after orthokeratology, with particular emphasis on the alterations in spherical aberrations and coma. The changes in corneal morphology induced by orthokeratology lead to significant positive increase in both spherical aberration and coma. Furthermore, the elevation of spherical aberration and coma demonstrates a negative correlation with the rate of axial length growth following orthokeratology. The interplay among spherical aberration, coma, defocus, accommodation, astigmatism, and pseudo-accommodation may constitute the underlying mechanism governing the control of myopia through orthokeratology.

2.
International Eye Science ; (12): 810-815, 2024.
Article in Chinese | WPRIM | ID: wpr-1016601

ABSTRACT

AIM: To assess the repeatability and agreement of higher-order aberration obtained by adaptive optics visual simulator(VAO)compared with OPD-Scan Ⅲ.METHODS: A cross-sectional study was conducted from August to September 2023, including a total of 204 patients(204 eyes)with myopia whose right eyes were measured. The examinations were performed by the same skilled examiner using both devices separately. The VAO device was used to measure higher order aberrations of orders 3 to 6 at a pupil diameter of 4.5 mm, while both the VAO and OPD-Scan Ⅲ devices were utilized to measure total higher-order aberration(tHOA), spherical aberration(SA), coma aberration(Coma), and trefoil aberration(Trefoil)of the entire eye at pupil diameters ranging from 3 to 6 mm. Furthermore, the repeatability of whole eye aberration measurements obtained with the VAO device was evaluated and the agreement of the two devices was assessed.RESULTS: The whole-eye higher-order aberrations measured by VAO demonstrated excellent repeatability(0.767≤ICC≤0.941, Sw<0.01 μm, TRT<0.1 μm). There was no statistically significant difference in Coma measured by VAO or OPD-Scan Ⅲ for pupil diameters ranging from 4 to 6 mm(P>0.05), while a statistically significant difference was observed in whole-eye tHOA of other pupil diameters(all P<0.05). The agreement of aberration measurements for each order between VAO and OPD-Scan Ⅲ for 3 mm pupil diameters, SA at 4 and 5 mm pupil diameter and Coma at 4 mm pupil diameter showed a 95% limit of agreement(LoA)<0.1, indicating good agreement; however, poor agreement was found for the remaining aberration measurements at different pupil diameters, with a 95%LoA>0.1, and there were significant differences in higher-order aberrations measured by two devices under a pupil diameter of 3 mm(r=0.218-0.317, P<0.01), 4 mm(r=0.406-0.672, P<0.01), 5 mm(r=0.538-0.839, P<0.01 and r=0.030-0.109, P>0.01)and 6 mm(r=0.369-0.766, P<0.01).CONCLUSION: The VAO demonstrates favorable repeatability when assessing whole-eye higher order aberration under pupil diameters of 3-6 mm. However, there is inadequate agreement and interchangeability in whole-eye higher order aberration at 3-6 mm pupil diameter between VAO and OPD-Scan Ⅲ for clinical purposes.

3.
International Eye Science ; (12): 656-660, 2024.
Article in Chinese | WPRIM | ID: wpr-1012839

ABSTRACT

AIM: To explore the clinical effect of small incision lenticule extraction(SMILE)on the treatment of myopic anisometropia.METHODS: Clinical data of 76 patients(146 eyes)with myopic anisometropia who received SMILE or femtosecond assisted laser in situ keratomileusis(FS-LASIK)in our hospital from January 2021 to December 2022 were retrospectively analyzed. The patients were divided into SMILE group(39 cases, 77 eyes)and FS-LASIK group(37 cases, 69 eyes)according to surgical methods. Uncorrected visual acuity(UCVA), diopter, anisometropia, corneal aberration and occurrence of postoperative complications were compared between the two groups at 1 wk, 1 and 3 mo after surgery.RESULTS: The UCVA of the two groups was improved after surgery compared with that before surgery, and the coma, trefoil, spherical aberration and total higher-order aberration were significantly increased compared to those before surgery(P<0.05), and the coma, trefoil, spherical aberration and total higher-order aberration in the FS-LASIK group were significantly higher than those in the SMILE group(P<0.05). After follow-up to 3 mo after surgery, the incidence of postoperative complications was significantly lower in the SMILE group than that in the FS-LASIK group(5.2% vs 15.9%, P<0.05).CONCLUSION: Both SMILE and FS-LASIK can effectively enhance the UCVA and improve the visual quality in patients with myopic anisometropia, but SMILE has lower corneal higher order aberrations, lower incidence of postoperative complications and better overall effect.

4.
Indian J Ophthalmol ; 2023 May; 71(5): 1849-1854
Article | IMSEAR | ID: sea-225058

ABSTRACT

Purpose: To evaluate the postoperative visual outcomes, that is, corneal higher?order aberrations (HOAs) and visual quality, of patients with an angle kappa greater than 0.30 mm who underwent angle kappa adjustment during small?incision lenticule extraction (SMILE) 2 years after surgery compared to eyes with an angle kappa less than 0.30 mm. Methods: This was a retrospective study and included 12 patients from October 2019 to December 2019 who underwent the SMILE procedure for correction of myopia and myopic astigmatism and had one eye with a large kappa angle and another eye with a small kappa angle. Twenty?four months after surgery, an optical quality analysis system (OQAS II; Visiometrics, Terrassa, Spain) was used to measure the modulation transfer function cutoff frequency (MTFcutoff), Strehl2D ratio, and objective scatter index (OSI). HOAs were measured with a Tracey iTrace Visual Function Analyzer (Tracey version 6.1.0; Tracey Technologies, Houston, TX, USA). Assessment of subjective visual quality was achieved using the quality of vision (QOV) questionnaire. Results: At 24 months postoperatively, the mean spherical equivalent (SE) refraction was ? 0.32 ± 0.40 and ? 0.31 ± 0.35 in the S?kappa group (kappa <0.3 mm) and the L?kappa group (kappa ?0.3 mm), respectively (P > 0.05). The mean OSI was 0.73 ± 0.32 and 0.81 ± 0.47, respectively (P > 0.05). There was no significant difference in MTFcutoff and Strehl2D ratio between the two groups (P > 0.05). Total HOA, coma, spherical, trefoil, and secondary astigmatism were not significantly different (P > 0.05) between the two groups. Conclusion: Adjustment of angle kappa during SMILE helps reduce the decentration, results in less HOAs, and promotes visual quality. It provides a reliable method to optimize the treatment concentration in SMILE.

5.
Rev. peru. biol. (Impr.) ; 30(2)abr. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1515499

ABSTRACT

Se reporta la primera observación de un espécimen leucístico en el Juil de Jamapa, Rhamdia laticauda en el noreste del estado de Oaxaca. En un estudio ictiológico de la Reserva de la Biosfera Tehuacán-Cuicatlán en el río Xiquila de la cuenca alta del río Papaloapan, el pez se capturó con pesca eléctrica y se fotografió. El bagre vivo mostró una reducción de pigmentos en la piel, manchas blancas y ojos negros normales. Esto contribuye al conocimiento de la variabilidad intraespecífica y la historia natural de R. laticauda. Se discuten las causas potenciales de esta anomalía de color.


Here, we report the first observation of a leucistic specimen in the Rock catfish, Rhamdia laticauda in the Northeast of Oaxaca, Mexico. We caught the specimen by electric fishing and then photographed during an ichthyological survey carried out in the Tehuacán-Cuicatlán Biosphere Reserve in the Xiquila River of the upper Papaloapan River basin. The live catfish showed a lack of pigment in the skin, white spots, and normal eye color. This information contributes to the knowledge about intraspecific variability and natural history of R. laticauda. We discuss the potential causes of this color anomaly.

6.
Rev. peru. biol. (Impr.) ; 30(2)abr. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1515500

ABSTRACT

Este trabajo documenta el primer registro de anomalías cromáticas en el pecarí de collar (Pecari tajacu) y el tercero en el mapache (Procyon lotor) para México. Los hallazgos se realizaron durante el monitoreo realizado entre el 2009 y el 2021, utilizando cámaras-trampa, principalmente en la ecorregión de la Sierra Madre del Sur del estado de Guerrero, México. Procyon lotor fue registrado entre el 5 de noviembre y el 1 de diciembre de 2019, en vegetación riparia de bosque tropical caducifolio (17°47'35"N, 98°39'59"W, 1134 m de altitud). Mientras que Pecari tajacu se registró el 7 de junio y el 22 de julio del 2021 en una brecha saca cosecha abandonada (17°38'12"N, 100°40'50"W; 1532 m de altitud).


This paper documents the first record of chromatic anomalies in Collared Peccary (Pecari tajacu) and the third in the Raccoon (Procyon lotor) for Mexico. The findings were made during monitoring conducted between 2009 and 2021, using camera traps, primarily in the Sierra Madre del Sur ecoregion of the state of Guerrero, Mexico. Procyon lotor was recorded between November 5th and December 1st, 2019, in riparian vegetation of a deciduous tropical forest (17°47'35"N, 98°39'59"W, 1134 m altitude). Meanwhile, Pecari tajacu was recorded on June 7th and July 22nd, 2021, in an abandoned crop clearing (17°38'12"N, 100°40'50"W; 1532 m altitude).

7.
Indian J Ophthalmol ; 2023 Feb; 71(2): 467-475
Article | IMSEAR | ID: sea-224830

ABSTRACT

Purpose: To develop a nomogram in cases with mismatch between subjective and Topolyzer cylinder, and based on the magnitude of the mismatch, customize a treatment plan to attain good visual outcomes post?laser?assisted in situ keratomileusis (LASIK) surgery. Methods: The patients were evaluated preoperatively using corneal tomography with Pentacam. Five optimal corneal topography scans were obtained from the Topolyzer Vario were used for planning the LASIK treatment. For the nomogram purpose, the patients were divided into three categories based on the difference between the subjective cylinder and Topolyzer (corneal) cylinder. The first group (group 1) consisted of eyes of patients, where the difference was less than or equal to 0.4 D. The second group (group 2) consisted of eyes, where the difference was more than 0.4 D and the subjective cylinder was lesser than the Topolyzer cylinder. The third group (group 3) included eyes where the difference was more than 0.4 D but the subjective cylinder was greater than the Topolyzer cylinder. LASIK was performed with the WaveLight FS 200 femtosecond laser and WaveLight EX500 excimer laser. Assessment of astigmatism correction for the three groups was done using Aplins vector analysis. For comparison of proportions, Chi?square test was used. A P value less than 0.05 was considered statistically significant. Results: The UDVA was statistically significantly different when compared between groups 1 and 2 (P = 0.02). However, the corrected distance visual acuity (CDVA) was similar among all the three groups (P = 0.1). Group 3 showed an increase of residual cylinder by ?0.25 D, which was significant at intermediate and near reading distances (P < 0.05). Group 3 showed significantly higher target?induced astigmatism (TIA) compared to groups 1 and 2 (P = 0.01). The mean surgically induced astigmatism (SIA) was the least in group 2, which was statistically significant (P < 0.01). Conclusion: The outcomes for distance vision using our nomogram postoperatively were excellent, but further refinement for improving the near vision outcomes is required

8.
Malaysian Journal of Medicine and Health Sciences ; : 160-170, 2023.
Article in English | WPRIM | ID: wpr-996958

ABSTRACT

@#Introduction: Chronic lymphocytic leukaemia (CLL) is the most frequent adult leukaemia in the Western world. The clinical presentation varies greatly, from very indolent cases to those with aggressive and fast advancing disease. This variation has significant implications for clinical approaches, therapeutic tactics, and, ultimately, survival durations from diagnosis. Acquired chromosomal aberrations play a key role in CLL aetiology. Due to difficulty to obtain abnormal metaphases for analysis, few methods such as fluorescence in-situ hybridization (FISH) and multiplex ligation-dependent probe assay (MLPA) were employed to detect chromosomal aberration however the methods are limited to specific locus only. Thus, this study is aimed to detect the chromosomal aberrations using DNA microarray platform. Methods: In this retrospective study, DNA archive obtained from 7 CLL patients which collected at diagnosis and subjected to Affymetrix CytoScan® 750K single nucleotide polymorphism (SNP) array following the manufacture procedure. The raw data obtained were analysed using the Chromosome Analysis Suite (ChAS) software (Affymetrix) using annotations of genome version GRCh38 (hg38). Result: Out of 7 patients, 4 of them showing deletion of 13q while 3 of them showing deletion of 14q in various region . Some of the deleted loci were too small (0.42-0.6Mb) to be detected by conventional cytogenetic analysis (CCA). There was also the presence of additional chromosomal aberrations that could be missed by CCA, FISH, or MLPA due to cryptic deletion or duplication that was as small as 0.4MB in size. Conclusion: The present study showed that low resolution chromosomal aberration was able to be detected using DNA microarray platform in comparison to CCA, FISH and MLPA.

9.
Chinese Journal of Postgraduates of Medicine ; (36): 184-188, 2023.
Article in Chinese | WPRIM | ID: wpr-990989

ABSTRACT

Objective:To investigate the effects of femtosecond laser assistcataract extraction on the levels of inflammatory factors in aqueous humor, corneal perception and high order aberration.Methods:Forty-eight patients (56 eyes) undergoing cataract surgery in the Shouguang People′s Hospital from June 2018 to February 2020 were enrolled in this study, and they were divided into observation group (24 patients and 27 eyes, femtosecond laser cataract phacoemulsification) and control group (24 patients and 29 eyes, coaxial microincision phacoemulsification) by random number table method. The levels of prostglndin E2 (PGE2), interleukin (IL)-6 and IL-1β in aqueous humor were detected before and after operation. Upper corneal and central corneal perception thresholds were recorded before surgery, 7 d after surgery, 1 month after surgery and 3 months after surgery. High order aberrations of the whole eye and cornea at 4mm pupil diameter before and after operation were recorded.Results:After operation, the levels of PGE2, IL-6 and IL-1β in aqueous humor in the observation group were lower than those in the control group: (45.62 ± 5.71) ng/L vs. (63.65 ± 5.62) ng/L, (15.25 ± 3.21) ng/L vs. (24.59 ± 6.13) ng/L, (17.16 ± 1.28) ng/L vs. (25.74 ± 4.62) ng/L, the differences were statistically significant ( P<0.05). The upper and central corneal perception threshold of observation group after operation for 7 d were higher than those in the control group: 4.55 ± 0.50 vs. 4.20 ± 0.33, 5.68 ± 0.49 vs. 5.52 ± 0.45, the differences were statistically significant ( P<0.05). The indexes of high order aberration of the whole eye decreased in the two groups ( P<0.05), while the indexes of cornea did not change significantly. The indexes of high order aberration of the whole eye and cornea between before and after surgery between the two groups had no significant differences ( P>0.05). Conclusions:Femtosecond laser assist cataractextraction can relieve inflammation, reduce the whole eye high order aberration, but not affect the cornea, and can improve corneal perception.

10.
Chinese Journal of Experimental Ophthalmology ; (12): 782-794, 2023.
Article in Chinese | WPRIM | ID: wpr-990913

ABSTRACT

Objective:To investigate the status of corneal epithelial remodeling and changes in corneal aberration after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) and FS-LASIK combined with corneal collagen cross-linking (FS-LASIK Xtra), and to analyze the relationship between corneal epithelial thickness (CET) and corneal aberration.Methods:A cohort study was conducted.A total of 172 patients (172 eyes) who underwent FS-LASIK at Yinhai Eye Hospital of Chengdu University of Traditional Chinese Medicine were enrolled from June 2021 to February 2022.The 172 eyes were divided into FS-LASIK group (94 eyes) and FS-LASIK Xtra group (78 eyes) according to the surgical procedure, with a total follow-up of 6 months.The cornea was divided into a central 2-mm ring and a ring of 2-5 mm centered on the central cornea.CET at 9 regions in the central 0-5 mm area was measured by OCT before and at 1, 3 and 6 months after surgery, and the corneal higher-order aberration (HOA) was measured by the iTrace visual function analyzer.The main outcomes were the increase in CET (ΔCET), and corneal HOA at 6 months after surgery.The relationship between central corneal ΔCET and corneal aberration was analyzed.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Yinhai Eye Hospital of Chengdu University of Traditional Chinese Medicine (No.2021yh-009). Written informed consent was obtained from each subject.Results:At 1, 3 and 6 months after surgery, the central, superior, superior nasal, nasal, inferior nasal, inferior, inferior temporal, temporal and superior temporal ΔCET were significantly smaller in FS-LASIK Xtra group than in FS-LASIK group (all at P<0.05). In FS-LASIK Xtra group, 6-month postoperative central, superior, superior nasal, inferior and inferior temporal ΔCET were significantly larger than those at 1 month after surgery, and 3- and 6-month postoperative temporal ΔCET were significantly larger than that at 1 month after surgery, and 6-month postoperative superior temporal ΔCET was significantly larger than those at 1 and 3 months after surgery (all at P<0.05). In FS-LASIK group, 3- and 6-month postoperative central, superior, inferior and inferior temporal ΔCET were significantly larger than those at 1 month after surgery, and 6-month postoperative superior nasal ΔCET was significantly larger than that at 3 months after surgery, and 6-month postoperative nasal, inferior nasal, temporal, superior temporal ΔCET were significantly larger than those at 1 and 3 months after surgery (all at P<0.05). There was no significant difference in vertical trefoil, vertical and horizontal coma changes at different time points after surgery between both groups (vertical trefoil: χ2group=4.27, P=0.118; χ2time=0.01, P>0.05.vertical coma: χ2group=5.74, P=0.057; χ2time=0.08, P=0.957.horizontal coma: χ2group=3.97, P=0.137; χ2time=0.51, P=0.773). The tilted trefoil changes at 1, 3 and 6 months after surgery of FS-LASIK Xtra group were significantly larger than those of FS-LASIK group (all at P<0.05). The 6-month spherical aberration change in FS-LASIK Xtra group was significantly higher than that at 1 month after surgery, and the 6-month spherical aberration change in FS-LASIK group was significantly higher than that at 1 and 3 months after surgery (all at P<0.05). The 6-month total HOA change in FS-LASIK group was significantly lower than that at 1 and 3 months after surgery (all at P<0.05). In FS-LASIK group, central corneal ΔCET was weakly positively correlated with spherical aberration at 1 and 6 months after surgery ( rs=0.257, P=0.008; rs=0.244, P=0.012), and was weakly positively correlated with total HOA ( rs=0.253, P=0.009; rs=0.279, P=0.004). Conclusions:The postoperative ΔCET after FS-LASIK Xtra is smaller than that after FS-LASIK, but the homogeneity of ΔCET in each region is similar between the two groups.The changes in corneal HOA after surgery are similar in both groups, and there is a certain association between the overall epithelial distribution and corneal aberration.

11.
Chinese Journal of Experimental Ophthalmology ; (12): 768-775, 2023.
Article in Chinese | WPRIM | ID: wpr-990911

ABSTRACT

Objective:To investigate the differences and changes in early postoperative visual quality after small incision lenticule extraction (SMILE) and smart pulse technology-assisted transepithelial photorefractive keratectomy (SPT-TransPRK).Methods:A cohort study was performed.A total of 92 patients (92 eyes) who underwent corneal laser refractive surgery were enrolled in Dalian Third People's Hospital Affiliated to Dalian Medical University from February 2021 to May 2021.The data from the right eye were collected for analysis.The patients were divided into SMILE group (40 patients, 40 eyes) and SPT-TransPRK group (52 patients, 52 eyes). Preoperative, 1- and 3-month postoperative visual acuity were measured to calculate the effectiveness, which was defined as the ratio of postoperative uncorrected visual acuity (UCVA) to preoperative best corrected visual acuity.Refraction was measured by an AR-1 autorefractor.Corneal higher-order aberration (HOA) including total HOA, spherical aberration and coma was measured by Sirius corneal topographer.Objective scatter index (OSI), modulation transfer function cut-off frequency (MTF cut-off), Strehl ratio (SR), simulated contrast visual acuity VA100 (day), VA20 (dusk) and VA9 (night) were measured via OQAS II visual quality analysis system.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of the Dalian Third People's Hospital Affiliated to Dalian Medical University (No.2019-KT-010). Written informed consent was obtained from each subject.Results:There was no significant difference in 3-month postoperative UCVA and effectiveness between the two groups ( Z=0.880, P=0.380; t=0.920, P=0.058). Patients in SPT-TransPRK group showed mild hyperopia 3 months after surgery.Preoperative, 1- and 3-month postoperative total corneal HOA was (0.47±0.18), (0.70±0.22) and (0.74±0.19)μm in SMILE group, and (0.40±0.14), (0.98±0.35) and (0.94±0.22)μm in SPT-TransPRK group respectively, showing statistically significant differences ( Fgroup=13.851, P=0.001; Ftime=29.960, P<0.001). Preoperative, 1- and 3-month postoperative spherical aberration was (-0.20±0.09), (-0.44±0.14) and (-0.44±0.15)μm in SMILE group, and (-0.20±0.10), (-0.71±0.23) and (-0.75±0.20)μm in SPT-TransPRK group respectively, showing statistically significant differences ( Fgroup=31.037, P<0.001; Ftime=48.005, P<0.001). The postoperative total corneal HOA and spherical aberration were increased in both groups compared with before surgery, with statistically significant differences (all at P<0.05). The 1- and 3-month postoperative total corneal HOA and spherical aberrations were smaller in SMILE group than in SPT-TransPRK group, and the differences were statistically significant (all at P<0.05). The 1- and 3-month postoperative coma were increased in both groups compared with before surgery, showing statistically significant differences (all at P<0.05). In SMILE group, 1-month postoperative OSI was higher and 1-month postoperative MTF cut-off, SR, and VA9 were lower than those before surgery, and 3-month postoperative OSI was higher and 3-month postoperative SR and VA9 were lower than those before surgery, showing statistically significant differences (all at P<0.05). In SPT-TransPRK group, 1-month postoperative OSI was higher and 1-month postoperative MTF cut-off, SR, VA100, VA20, and VA9 were lower than those before surgery, showing statistically significant differences (all at P<0.05). There was no significant difference in OSI, MTF cut-off, SR, VA100, VA20, and VA9 between 3 months postoperatively and before surgery in the SPT-TransPRK group (all at P>0.05). There was no significant difference in coma, OSI, MTF cut-off, SR, VA100, VA20, and VA9 between two groups (all at P>0.05). Conclusions:Both SMILE and SPT-TransPRK are effective methods for correcting myopia and they have comparable visual quality.Compared with SPT-TransPRK, corneal total HOA and spherical aberration are smaller after SMILE.

12.
Chinese Journal of Experimental Ophthalmology ; (12): 755-762, 2023.
Article in Chinese | WPRIM | ID: wpr-990909

ABSTRACT

Objective:To analyze and compare the corneal higher order aberration (HOA) after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE).Methods:A non-randomized controlled study was conducted.Sixty myopic patients (60 eyes) who underwent FS-LASIK or SMILE correction at Shandong Eye Hospital from April 2018 to January 2020 were enrolled and the data from the right eye were collected for analysis.Thirty cases (30 eyes) who received FS-LASIK in FS-LASIK group and 30 cases (30 eyes) who received SMILE in SMILE group had a preoperative equivalent spherical diopter of (-5.36±1.11)D and (-4.93±1.03)D, respectively.The HOA of the 6-mm anterior surface, posterior surface, and whole cornea were measured before surgery and at 1, 3, 6, and 12 months after surgery using Pentacam.The root mean square values (μm) of total corneal HOA, spherical aberration, coma and trefoil were obtained.Differences in the above root mean square values at different time points were compared between the two groups.The study protocol adhered to the Declaration of Helsinki and was approved by the Ethics Committee of Shandong Eye Hospital (No.SDSYKYY20180306). Written informed consent was obtained from each subject.Results:The preoperative and 1-, 3-, 6-, 12-month postoperative total HOA of the anterior corneal surface were (0.428±0.126), (0.775±0.169), (0.811±0.194), (0.759±0.214), (0.704±0.199)μm in the FS-LASIK group and (0.409±0.094), (0.656±0.148), (0.681±0.161), (0.668±0.175), (0.648±0.160)μm in the SMILE group, with a significant overall difference ( Fgroup=5.652, P=0.024; Ftime=107.169, P<0.01). Compared with SMILE group, the postoperative total HOA of anterior corneal surface and spherical aberration at different time points were increased in FS-LASIK group, showing statistically significant differences (all at P<0.05). Compared with before surgery, the postoperative total HOA of the anterior corneal surface and spherical aberration at different time points were increased in both groups, showing statistically significant differences (all at P<0.05). In the two groups, the 6- and 12-month postoperative total HOA of the anterior corneal surface were reduced in comparison with the 3-month postoperative ones of the anterior corneal surface, and the 12-month postoperative spherical aberrations of the anterior corneal surface were significantly reduced in comparison with the 1- and 3-month postoperative ones of the anterior corneal surface, showing statistically significant differences (all at P<0.05). There were significant differences in the coma and trefoil of the anterior corneal surface between before and after the operation (coma: Ftime=47.848, P<0.01; trefoil: Ftime=2.497, P=0.046). Compared with before surgery, the postoperative coma was significantly increased in the two groups (all at P<0.05). There were significant differences in total corneal HOA and spherical aberration at different postoperative time points between the two groups (total HOA: Fgroup=8.093, P=0.008; Ftime=125.019, P<0.01.spherical aberration: Fgroup=4.771, P=0.037; Ftime=34.033, P<0.01). Compared with SMILE group, the total corneal HOA and spherical aberration were significantly increased in FS-LASIK group at different postoperative time points (all at P<0.05). Compared with before surgery, postoperative total HOA of the anterior corneal surface and spherical aberration at different postoperative time points were significantly increased in both groups (all at P<0.05). In both groups, the 12-month postoperative corneal spherical aberration was significantly reduced in comparison with the 1- and 3-month postoperative ones (all at P<0.05). There was a significant difference in coma between before and after surgery ( Ftime=30.829, P<0.01). Compared with before surgery, the postoperative coma was significantly increased at different time points in both groups (all at P<0.05). Conclusions:Both FS-LASIK and SMILE increase the HOA of the anterior corneal surface and the whole cornea.Compared with FS-LASIK, SMILE introduces less HOA of the anterior corneal surface and the whole cornea as well as spherical aberrations.

13.
Shanghai Journal of Preventive Medicine ; (12): 674-678, 2023.
Article in Chinese | WPRIM | ID: wpr-988903

ABSTRACT

ObjectiveTo investigate the current status and high-risk factors of chromosomal aberrations in peripheral blood lymphocytes (PBL) of radiation workers in Hainan Province. MethodsA total of 200 radiological workers who underwent occupational health examination in Hainan Provincial Hospital of Traditional Chinese Medicine from January 2021 to December 2021 were selected to collect the occupational health examination data and the rate of PBL chromosomal aberrations. The influencing factors of PBL chromosomal aberrations were analyzed by logistic regression model. The predictive value of logistic regression prediction model on PBL chromosomal aberrations were determined by using the reciver operator characteristic (ROC) curve. ResultsA total of 20 000 cells (100 cells/person) were tested. The chromosomal aberration rate was 0.37% (74/20 000) and the PBL chromosomal aberration rate in the subjects was 6.00% (12/200). Univariate analysis showed that PBL chromosomal aberrations in radiological workers were related to age, length of service, type of work and education (all P<0.05), but not to gender (P>0.05). The logistic regression prediction model was constructed based on the influencing factors, with χ2=9.413, df=9, P=0.852, suggesting a good model fit. The logistic regression prediction model predicted the area under the curve (AUC) for the occurrence of PBL chromosomal aberrations in radiation workers was 0.914 (95%CI: 0.866‒0.949), with a cut-off value of 3.05, corresponding to a prediction sensitivity and specificity of 100.00% and 75.98%, respectively. ConclusionThe incidence of PBL chromosomal aberrations in radiological workers in Hainan Province was 6.00%, with age, working age and job type as high-risk factors and education level as a protective factor. The prediction model constructed by the above factors can provide a reliable basis for clinical prediction of PBL chromosomal aberrations in radiological workers.

14.
International Eye Science ; (12): 1723-1731, 2023.
Article in Chinese | WPRIM | ID: wpr-987898

ABSTRACT

AIM:To evaluate the agreement of corneal high-order aberrations from Topcon KR-1W, i.Profiler and OPD-Scan Ⅲ wavefront aberrometers in myopic adults.METHODS:A prospective clinical study. A total of 92 adult patients(92 eyes)with myopia in the department of optometry, the People's Hospital of Guangxi Zhuang Autonomous Region from June to August 2022 were enrolled. The third-order and fourth-order corneal aberrations at the pupil diameter of 4 and 6mm were measured by Topcon KR-1W, i.Profiler, and OPD-Scan Ⅲ, respectively. The difference and agreement of the three aberrometers were evaluated.RESULTS: The measurements at 6mm pupil diameter were all greater than those at 4mm pupil diameter. Although there were no statistical differences in the measurements of Z-44、Z-24 by the three aberrometers at 4 pupil diameter(P&#x003E;0.05), there were statistical differences in other measurements(P&#x003C;0.05). The aberration results measured by the three aberrometers were statistically different at the 6mm pupil diameter(P&#x003C;0.05). The 95% limit of agreement(95%LoA)of the measurements of higher-order aberration, including the third-order aberrations at 4mm pupil diameter and the third-order and fourth-order aberrations at 6mm pupil diameter(except for the Z-24)were greater than 0.1μm. The concordance correlation coefficient(Pc)was lower than 0.90, indicating a poor consistency. The correlation coefficients of corneal higher-order aberrations were significantly different among the three aberrometers at 4 and 6mm pupil diameter(r4mm=0.215~0.805, P4mm&#x003C;0.05; r6mm=0.561~0.916, P6mm&#x003C;0.001).CONCLUSION:There were significant differences in the measurements of the third- and fourth-order corneal aberrations at 4 and 6mm pupil diameter among Topcon KR-1W, i.Profiler, and OPD-Scan Ⅲ, and the agreements were poor, so they are not interchangeably in clinical applications.

15.
Journal of Pharmaceutical Practice ; (6): 50-55, 2023.
Article in Chinese | WPRIM | ID: wpr-953759

ABSTRACT

Objective To study the genotoxicities of raceanisodamine hydrochloride injection. Methods Bacterial reverse mutation test, in vitro Chromosomal aberration test and in vivo Micronucleus test were performed to investigate the genotoxicities of raceanisodamine hydrochloride injection. Results The Ames test showed that raceanisodamine hydrochloride injection did not increase mutagenicity for TA1535, TA102, TA100, TA98 and TA97 strains at the dosage of 0.5, 5, 50, 500, 5000 μg per plate under two parallel system conditions (±S9). Results of CA test indicated that there was no statistical difference between raceanisodamine hydrochloride injection groups (doses of 58.75,117.5 and 235.0 μg/ml) and the solvent control group under two parallel system conditions (±S9). In MNT test, with doses of 7.5, 15.0 and 30.0 mg/kg respectively, the micronucleus induction rate of bone marrow of ICR mice was not statistically significant (P>0.05) when compared with that of vehicle control group in all dose groups. Conclusion Under the conditions of these study, the results indicated that raceanisodamine hydrochloride injection had no mutagenicity to Salmonella typhimurium, had no aberration effect on the chromosome of mammalian cultured cells, and had no effect on inducing micronucleus of bone marrow polychromatic erythrocytes in ICR mouse. All test results showed that raceanisodamine hydrochloride injection had no potential carcinogenicities and genetic toxicities under the test conditions.

16.
International Eye Science ; (12): 648-654, 2023.
Article in Chinese | WPRIM | ID: wpr-965794

ABSTRACT

AIM:To observe the changes in corneal aberrations and the characteristics of visual quality after transepithelial photorefractive keratectomy(T-PRK)and femtosecond small incision lenticule extraction(SMILE)in the correction of low myopia.METHODS: Prospective cohort study. A total of 32 cases(32 eyes)with low myopia who underwent T-PRK surgery and 45 cases(45 eyes)of SMILE surgery at Weifang Eye Hospital from April 2021 to April 2022 were selected. The uncorrected visual acuity(UCVA), best corrected visual acuity(BCVA), spherical equivalent(SE), corneal higher-order aberrations(HOAs)and objective visual quality were compared between the two groups.RESULTS:All patients completed the surgery successfully without complications such as infection. At 3mo postoperatively, the safety index was 1.13±0.16 and 1.16±0.17(P=0.48)and the efficacy index was 1.10±0.20 and 1.15±0.18(P=0.27)in the T-PRK and SMILE groups, respectively. The percentage of UCVA(LogMAR)≤0 in the T-PRK and SMILE groups was 94% and 98%, respectively. The percentage of the residual SE within ±0.5D was 88% and 87% in the two groups, respectively. The HOAs and spherical aberration in both groups were significantly increased(P≤0.01), and the increase was not statistically significant between the two groups(P=0.31, 0.89). There was no significant change in horizontal coma, horizontal trefoil and vertical trefoil in both groups(P&#x0026;#x003E;0.05). The vertical coma in SMILE group was significantly increased(P&#x0026;#x003C;0.001), while there was no significant change in T-PRK group(P&#x0026;#x003E;0.05), and the increase was significantly greater in SMILE group than in T-PRK group(P&#x0026;#x003C;0.001). There was no significant difference in objective scattering index(OSI), modulation transfer function cut off frequency(MTFcut off), Strehl ratio(SR), visual acuity(VA)100%, VA20% and VA9% between the two groups(P&#x0026;#x003E;0.05).CONCLUSION:Both T-PRK and SMILE showed good safety, efficacy, and visual quality in correcting low myopia, while SMILE induced more vertical coma than T-PRK.

17.
Chinese Journal of Radiological Health ; (6): 30-34, 2023.
Article in Chinese | WPRIM | ID: wpr-965368

ABSTRACT

@#<b>Objective</b> To investigate the occupational health status of 450 radiation workers in a steel mill when they resigned, and to provide references and suggestions for the occupational health monitoring of the enterprise employees and for the workers’ proper arrangement after their resignations. <b>Methods</b> Occupational health examinations were performedon 450 steel workers who were about to resign in accordance with the applicable laws and regulations. And the examination results were statistically analyzed. <b>Results</b> Among the 450 radiation workers, 82% had abnormal examination results which included chromosome aberration in peripheral blood lymphocytes (4.89%), lens opacity (44.44%), pinguecula (25.33%), hypertension (28.22%), thyroid dysfunction (9.59%), and abnormal liver ultrasound findings (30.89%). Compared with the normal population, these steel workers had a significantly higher chromosome aberration rate in peripheral blood lymphocytes and a significantly higher incidence rate of ocular disorders. <b>Conclusion</b> It is important to effectively manage the occupational health of radiation employees in steel mills, and to regularly provide training on occupational health protection. To avoid radiation damage, workers should pay close attention to radiation protection at work, especially eye protection, to avoid eye disorders.

18.
International Eye Science ; (12): 312-315, 2023.
Article in Chinese | WPRIM | ID: wpr-960957

ABSTRACT

AIM: To evaluate the clinical efficacy of femtosecond laser-assisted cataract surgery combined with PanOptix trifocal intraocular lens implantation.METHODS:The retrospective study enrolled 22 cases(26 eyes)of cataract patients who underwent femtosecond laser-assisted cataract surgery combined with PanOptix trifocal intraocular lens implantation from August 2020 to August 2021. Follow-up to 3mo after surgery, the changes of far, intermediate and near visual acuity, aberration, Strehl ratio(SR)and modulation transfer function cutoff(MTF-cutoff)frequency were compared. Defocus curve at 1mo postoperatively was made, and the visual quality and satisfaction were evaluated after 3mo of surgery.RESULTS: The visual acuity of all patients was better than 0.1(LogMAR)at the far, intermediate and near distance at 1d, 1wk, 1 and 3mo postoperatively, and it was significantly improved compared with those before surgery(all P&#x0026;#x003C;0.01). The defocus curve transitioned smoothly between +0.5 and -3.0D at 1mo after surgery, and visual acuity was better than 0.63. The total aberration and spherical aberration in the whole eye were significantly lower after surgery than before, and the SR and MTF-cutoff were significantly improved at 1d and 1wk after surgery(all P&#x0026;#x003C;0.05). With high satisfaction and good visual quality, patients could watch at far, intermediate and near distance without wearing glasses at 3mo after surgery.CONCLUSION: Femtosecond laser-assisted cataract surgery combined with PanOptix trifocal intraocular lens implantation gave patients a comfortable and satisfactory full-course vision.

19.
International Eye Science ; (12): 228-231, 2023.
Article in Chinese | WPRIM | ID: wpr-960941

ABSTRACT

Implantable collamer lens(ICL)and toric ICL(TICL)are clinically common types of posterior chamber phakic intraocular lenses, they are mainly used to correct high myopia and low-to-moderate myopia of eyes whose corneal conditions are not suitable for corneal laser surgery. Accurate preoperative measurement, safe intraoperative implantation and appropriate postoperative location of lenses are critical to ensure the outcome of ICL implantable, and the appearance of V4c ICL with a central hole ensures the safety of this surgery to a greater extent. However, the intraocular position of both ICL and TICL is not invariable. Some studies have shown that the vault has a trend of decreasing year by year after ICL surgery, but its reason is unknown. And spontaneous rotation may occur after the TICL surgery, thereby causing visual loss, which is one of the main causes of TICL replacement. And postoperative changes in the position of the central hole also need attention. In addition, the visual quality of the operated eye will change after ICL/TICL implantation, but whether the change of intraocular positions of implanted lenses will affect the postoperative visual quality is also a problem that needs to be paid attention to and explored. Therefore, this paper reviewed the postoperative changes in vault, TICL axis, position of the central hole and their causes, as well as the effects of these changes on postoperative visual quality, offering valuable clinical guidance for accurate preoperative selection of ICL/TICL and surgical design, so as to improve the effectiveness and stability of ICL implantation in correction of myopic refractive error.

20.
International Eye Science ; (12): 1196-1201, 2023.
Article in Chinese | WPRIM | ID: wpr-976495

ABSTRACT

AIM: To evaluate the effect of anterior capsule polishing on visual quality after phacoemulsification.METHODS: Prospective randomized control study. A total of 65 patients(73 eyes)with age-related cataract who underwent phacoemulsification combined with intraocular lens(IOL)implantation in the Emergency General Hospital between November 2021 and June 2022 were included. These patients were randomly assigned to two groups, with one group(anterior polishing group)underwent anterior and posterior capsule polishing(30 cases, 35 eyes), while the other(control group)receive routine posterior capsule polishing(35 cases, 38 eyes). Best corrected visual acuity was observed at 1wk, 1, 3 and 6mo after operation. Area of anterior capsule orifice was measured at 3 and 6mo after operation. Meanwhile, posterior capsular opacification(P score), IOL tilt and decentration were recorded by Pentacam Scheimpflug system. In addition, wavefront aberration, Strehl ratio(SR)of point spread function(PSF)and modulation transfer function(MTF)were evaluated by OPD-Scan Ⅲ.RESULTS: At 1wk, 1, 3 and 6mo after operation, best corrected visual acuity in anterior polishing group is significantly better than that of control group(P&#x003C;0.05). There were no significant differences in area of anterior capsule opening, P score, IOL decentration, SR of PSF and MTF between two groups at 3 and 6mo after operation(P&#x003E;0.05). At 3mo follow-up, no significant differences in IOL tilt and wavefront aberration were measured between two groups either(P&#x003E;0.05). However, IOL tilt [(1.65±0.60)° vs.(2.34±0.43)°, P&#x003C;0.001] and wavefront aberration(0.03±0.01μm vs. 0.06±0.03μm, P&#x003C;0.001)in anterior polishing group were significant lower compared to control group at 6mo after operation.CONCLUSION: 360° polishing of anterior and posterior capsule during phacoemulsification can improve best corrected visual quality, with reduced IOL tilt, lower wavefront aberration and better visual quality.

SELECTION OF CITATIONS
SEARCH DETAIL