Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.681
Filter
1.
International Eye Science ; (12): 62-66, 2024.
Article in Chinese | WPRIM | ID: wpr-1003507

ABSTRACT

The finite element method(FEM)is a widely employed mathematical technique in mechanical research that divides an object into discrete and interacting finite elements. Medically, finite element analysis(FEA)enables the simulation of biomechanical experiments that are challenging to conduct. Orbital surgery poses significant challenges to ophthalmologists due to its inherent difficulty and steep learning curve. FEM enables the simulation and analysis of the mechanical properties of orbital tissue, offering a novel approach for diagnosing and treating orbital-related diseases. With technological advancements, FEM has significantly matured in the diagnosis and treatment of orbital diseases, becoming a popular area of research in orbital biomechanics. This paper reviewed the latest advancements in orbital FEM, encompassing the development of orbital FEA models, simulation of orbital structure, and its application in orbital-related diseases. Additionally, the limitations of FEM and future research directions are also discussed. As a digital tool for auxiliary diagnosis and treatment, orbital FEA will progressively unlock its potential for diagnosing and treating orbital diseases alongside technological advancements.

2.
International Eye Science ; (12): 522-527, 2024.
Article in Chinese | WPRIM | ID: wpr-1012814

ABSTRACT

AIM:To investigate the effect of small incision lenticule extraction(SMILE)on the treatment of myopia patients, and the impact on corneal biomechanics.METHODS:Retrospective study. A total of 120 myopic patients(240 eyes)who were scheduled to undergo corneal refractive surgery in Anyang Eye Hospital from January 2020 to December 2021 were selected. The patients were divided into SMILE group(64 patients, 128 eyes)and transepithelial photorefractive keratectomy(TransPRK)group(56 patients, 112 eyes)according to the surgical treatment method. The two groups were compared in terms of uncorrected visual acuity, corneal biomechanics, corneal endothelial cell count, posterior corneal surface height and corneal surface regularity index at 1, 7 d, 1, 3, 6 mo and 1 a after surgery, and surgical complications.RESULTS:The uncorrected visual acuity of the SMILE group at 1, 7 d and 1 mo after surgery was better than that of the TransPRK group(all P<0.001), but there was no statistically significant difference between the groups at 3, 6 mo and 1 a after surgery(all P>0.05). Compared with preoperative values, corneal-compensated intraocular pressure, Goldmann-correlated intraocular pressure, corneal resistance factor, and corneal hysteresis in both groups showed a first decreasing and then increasing trend after surgery. The corneal-compensated intraocular pressure, Goldmann-correlated intraocular pressure, corneal resistance factor, and corneal hysteresis in the SMILE group at 1, 7 d and 1 mo after surgery were higher than those in the TransPRK group(all P<0.05), but there was no statistically significant difference between the groups at 3, 6 mo and 1 a after surgery(all P>0.05). There were no significant changes of corneal endothelial cell count and corneal posterior surface height in the two groups after surgery(all P>0.05). Furthermore, corneal surface regularity index of the two groups showed a first increasing and then decreasing trend after surgery, with no statistically significant difference between the groups(P>0.05), and there was no statistically significant difference in the incidence of postoperative complications between the groups(P>0.05).CONCLUSION:Compared with TransPRK, SMILE has less influence on corneal biomechanics, and better visual recovery in the early stage. There is no difference in long-term visual acuity between the two surgeries, and both have good safety and effectiveness.

3.
Braz. dent. sci ; 27(2): 1-12, 2024. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-1551332

ABSTRACT

Objective: In response to the demand for dental implants, extensive research has been conducted on methods for transferring load to the surrounding bone. This study aimed to evaluate the stresses on the peripheral bone, implants, and prostheses under scenarios involving of the following variables: prosthesis designs, vertical bone heights, load angles, and restorative materials. Material and Methods: Three implants were inserted in the premolar and molar regions (5-6-7) of the two mandibular models. Model 1 represented 0 mm marginal bone loss and Model 2 simulated 3 mm bone loss. CAD/CAM-supported materials, hybrid ceramic (HC), resin-nano ceramic (RNC), lithium disilicate (LiSi), zirconia (Zr), and two prosthesis designs (splinted and non-splinted) were used for the implant-supported crowns. Forces were applied vertically (90°) to the central fossa and buccal cusps and obliquely (30°) to the buccal cusps only. The stresses were evaluated using a three-dimensional Finite Element Analysis. Results: Oblique loading resulted in the highest stress values. Of the four materials, RNC showed the low stress in the restoration, particularly in the marginal area. The use of different restorative materials did not affect stress distribution in the surrounding bone. The splinted prostheses generated lower stress magnitude on the bone, and while more stress on the implants were observed. Conclusion: In terms of the stress distribution on the peri-implant bone and implants, the use of different restorative materials is not important. Oblique loading resulted in higher stress values, and the splinted prosthesis design resulted in lower stress (AU)


Objetivo: Em resposta à demanda por implantes dentários, extensa pesquisa foi realizada sobre métodos para transferir carga ao osso circundante. Este estudo buscou avaliar os estresses no osso periférico, implantes e próteses em cenários que envolvem as seguintes variáveis: designs de próteses, alturas ósseas verticais, ângulos de carga e materiais restauradores. Material e Métodos: Três implantes foram inseridos nas regiões dos pré-molares e molares (5-6-7) de dois modelos de mandíbula. O Modelo 1 representou perda óssea marginal de 0 mm e o Modelo 2 simulou perda óssea de 3 mm. Materiais suportados por CAD/CAM, cerâmica híbrida (HC), cerâmica nano-resina (RNC), dissilicato de lítio (LiSi), zircônia (Zr) e dois designs de próteses (sintetizadas e não-sintetizadas) foram utilizados para as coroas suportadas por implantes. Forças foram aplicadas verticalmente (90°) à fossa central e cúspides bucais e obliquamente (30°) apenas às cúspides bucais. Os estresses foram avaliados usando Análise de Elementos Finitos tridimensional. Resultados: Cargas oblíquas resultaram nos valores mais altos de estresse. Entre os quatro materiais, RNC mostrou baixo estresse na restauração, especialmente na área marginal. O uso de diferentes materiais restauradores não afetou a distribuição de estresse no osso circundante. Próteses sintetizadas geraram menor magnitude de estresse no osso, enquanto mais estresse nos implantes foi observado. Conclusão: Em termos de distribuição de estresse no osso peri-implantar e implantes, o uso de diferentes materiais restauradores não é crucial. Cargas oblíquas resultaram em valores mais altos de estresse, e o design de prótese sintetizada resultou em menor estresse. (AU)


Subject(s)
Dental Implants , Dental Prosthesis , Finite Element Analysis , Biomechanical Phenomena
4.
São Paulo med. j ; 142(2): e2022548, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1450518

ABSTRACT

ABSTRACT BACKGROUND: Current research supports the fact that prophylactic ankle taping (AT) is effective in preventing ankle injuries in amateur and elite sports athletes. OBJECTIVE: This study aimed to investigate the effect of AT on balance, knee valgus during drop jump and single-leg countermovement jump (SL-CMJ) landings, and ankle range of motion (ROM) restriction in healthy participants. DESIGN AND SETTING: A cross-sectional observational study was conducted at the Universidad Europea de Madrid, Madrid, Spain. METHODS: Participants: Thirty-nine healthy individuals participated in this study and performed the movements under two conditions (with and without tape). Outcome measurements: ankle ROM, balance, SL-CMJ height, flight time, ground time, and knee valgus. Before any intervention, a random process was developed with a 1:1 allocation ratio, and the participants were assigned to groups A (tape-no tape) and B (no tape-tape). RESULTS: Significant differences between tape and no-tape moments were observed for drop jump knee valgus flexion (P = 0.007), with an increase in knee valgus in participants with ankle taping. Similarly, the Y-balance testshowed a significant decrease in all variables (P = 0.001 and), ankle dorsiflexion (P = 0.001) in participants with ankle taping. CONCLUSIONS: AT is effective for immediate ankle ROM restriction. However, an increase in knee valgus during drop jump task and a decrease in lower limb balance were observed during drop jump task. Based on these results, it can be concluded that AT application in healthy individuals should not be recommended as it results in increase in injury risk factors.

5.
São Paulo med. j ; 142(3): e2022578, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1450522

ABSTRACT

ABSTRACT BACKGROUND: Ankle taping (AT) is effective in preventing ankle sprain injuries in most common sports and is employed in rehabilitation and prevention sports. OBJECTIVE: This study aimed to investigate the effectiveness of AT to restricting excessive frontal plane ankle movements in semi-professional basketball players throughout the training session. DESIGN AND SETTING: A cross-sectional study was performed at the Universidad Europea de Madrid. METHODS: Forty male and female semi-professional basketball players were divided into two groups. The ankle dorsiflexion range of motion (ROM) and interlimb asymmetries in a weight-bearing lunge position were evaluated at four time points: 1) with no tape, 2) before practice, at 30 min of practice, and 3) immediately after practice. RESULTS: In male basketball players, no differences were observed in the right and left ankles between the baseline and 30 min and between baseline and 90 min of assessment. In female athletes, significant differences were reported between baseline and pre-training assessments for the right ankle and also significant differences between baseline and 90 min in both ankles. CONCLUSIONS: Ankle taping effectively decreased the ankle dorsiflexion ROM in male and female basketball players immediately after application. However, ROM restriction was very low after 30 and 90 min, as assessed in a single basketball practice. Therefore, the classic taping method should be revised to develop new prophylactic approaches, such as the implementation of semi-rigid bracing techniques or the addition of active stripes during training or game pauses.

6.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 113-118, 2024.
Article in Chinese | WPRIM | ID: wpr-1009117

ABSTRACT

OBJECTIVE@#To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.@*METHODS@#The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.@*RESULTS@#Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.@*CONCLUSION@#Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.


Subject(s)
Humans , Biomechanical Phenomena , Bone Plates , Fracture Fixation, Internal , Fracture Fixation, Intramedullary , Tibial Fractures/surgery , Tibial Plateau Fractures
7.
Podium (Pinar Río) ; 18(2)ago. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1448881

ABSTRACT

El deporte como fenómeno social, se desarrolla en la actualidad simultáneamente con los adelantos de la ciencia y la tecnología; en este contexto, juega un papel importante la biomecánica que asegura las bases para un verdadero entrenamiento técnico, de ahí que el trabajo está dirigido al uso de la biomecánica en la técnica de pitcheo. Para dar respuesta a esta temática se concibe como objetivo aplicar estudios biomecánicos a la técnica de pitcheo en los lanzadores del equipo de béisbol La Isla de la Juventud. Se utilizaron como métodos el análisis de documentos, la revisión bibliográfica, la observación científica, la entrevista y la técnica del análisis de video con ayuda de un Dron; ello permitió medir magnitudes y valorar el comportamiento de las características que poseen los movimientos ejecutados por los lanzadores objeto de estudio. También, se emplearon dos técnicas de mediciones, una a través de la filmación y otra por procesamiento cinemático con el uso de los softwares como Tracker y Kinovea. La muestra estuvo conformada por ocho sujetos, distribuidos en tres atletas, dos entrenadores y tres investigadores; esto permitió determinar las características de la distancia de paso, ángulo que forma el brazo de lanzar con respecto a la cabeza, altura de la pelota y la velocidad de la pelota ejecutados por los lanzadores investigados.


O esporte, como fenômeno social, está se desenvolvendo simultaneamente com os avanços da ciência e da tecnologia; nesse contexto, a biomecânica desempenha um papel importante para garantir a base de um verdadeiro treinamento técnico, portanto, o trabalho visa ao uso da biomecânica na técnica de arremesso. Para responder a essa questão, o objetivo foi aplicar estudos biomecânicos à técnica de arremesso nos arremessadores do time de beisebol La Isla de la Juventud. Os métodos utilizados foram a análise de documentos, a revisão bibliográfica, a observação científica, a entrevista e a técnica de análise de vídeo com a ajuda de um drone, o que permitiu medir as magnitudes e avaliar o comportamento das características dos movimentos executados pelos arremessadores em estudo. Além disso, foram utilizadas duas técnicas de medição, uma por meio de filmagem e outra por meio de processamento cinemático com o uso de softwares como o Tracker e o Kinovea. A amostra foi composta por oito sujeitos, distribuídos em três atletas, dois técnicos e três pesquisadores, o que nos permitiu determinar as características da distância de arremesso, do ângulo do braço de arremesso em relação à cabeça, da altura da bola e da velocidade da bola executada pelos arremessadores investigados.


Sport as a social phenomenon, currently develops simultaneously with the advances of science and technology; in this context, biomechanics plays an important role that ensures the bases for true technical training; hence the work is directed to the use of biomechanics in throwing technique. To respond to this issue, the objective is to apply biomechanical studies to the throwing technique in the throwers of the La Isla de la Juventud baseball team. Document analysis, bibliographic review, scientific observation, interview and the technique of video analysis with the help of a drone were used as methods; this made it possible to measure magnitudes and assess the behavior of the characteristics of the movements executed by the throwers under study. Also, two measurement techniques were used, one through filming and the other by kinematic processing with the use of software such as Tracker and Kinovea. The sample consisted of eight subjects, divided into three athletes, two coaches and three researchers; this allowed to determine the characteristics of the throw distance, the angle formed by the throwing arm with respect to the head, the height of the ball, and the speed of the ball executed by the investigated throwers.

8.
Braz. dent. j ; 34(1): 80-88, Jan.-Feb. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1420569

ABSTRACT

Abstract This study aimed to evaluate the effect of different loading conditions on the mechanical behavior and stress distribution of a leucite-reinforced glass-ceramic. Plate-shaped ceramic specimens were obtained from leucite-reinforced glass-ceramic (1.5 × 8.4 × 8.3 mm) and adhesively cemented to a dentin analog substrate. Monotonic and cyclic contact fatigue tests were performed to simulate sphere-to-flat contact, using a 6 mm diameter spherical piston; and flat-to-flat contact, using a 3 mm diameter flat piston. For the monotonic test (n=20), a gradual compressive load (0.5 mm/min) was applied to the specimen using a universal testing machine. Failure load data were analyzed with Weibull statistics. The cyclic contact fatigue test was performed using protocols (load and a number of cycles) defined by the boundary technique (n=30). Fatigue data were analyzed using an inverse power law relationship and Weibull-lifetime distribution. The stress distribution was investigated using Finite Element Analysis (FEA). The monotonic and the fatigue Weibull modulus were similar among the two contact conditions. In fatigue, the slow crack growth exponent was greater for sphere-to-flat contact, which indicates that the load level had a greater effect on the specimen's probability of failure. In conclusion, FEA showed different stress distribution for the tested loading conditions. The stress distribution and probability of fatigue failure of specimens tested in sphere-to-flat contact showed greater dependency to load level.


Resumo O objetivo deste estudo é avaliar o efeito de diferentes condições de carregamento no comportamento mecânico e na distribuição de tensões de uma vitrocerâmica reforçada com leucita. Amostras cerâmicas em forma de lâminas foram obtidas a partir de vitrocerâmica reforçada com leucita (1,5 × 8,4 × 8,3 mm) e cimentadas adesivamente a um substrato análogo de dentina. Ensaios de carga de compressão monotônica e fadiga foram realizados para simular o contato esfera-plano, usando um pistão esférico de 6 mm de diâmetro; e contato plano com plano, usando um pistão plano de 3 mm de diâmetro. Para o ensaio de carga de compressão monotônica (n=20), foi aplicada uma carga compressiva gradual (0,5 mm/min) ao corpo-de-prova usando uma máquina de ensaio universal. Os dados de carga de fratura foram analisados de acordo com a distribuição de Weibull. O teste de fadiga foi realizado com os protocolos (carga e número de ciclos) definidos pela técnica de boundary (n=30). Os dados de fadiga foram analisados usando uma relação de tempo de vida - tensão de lei da potência inversa (IPL- inverse power law). A distribuição de tensões foi investigada usando análise de elementos finitos (AEF). O módulo de Weibull para teste de compressão monotônico e de fadiga foram semelhantes entre as duas condições de contato. Em fadiga, o expoente de crescimento sub-crítico da trinca foi maior para o contato esfera-plano, o que indica que o nível de carga teve um efeito maior na probabilidade de falha do corpo-de-prova. Em conclusão, AEF apresentou distribuição de tensões diferente para as condições de carregamento testadas. A distribuição de tensões e a probabilidade de falha em fadiga dos corpos-de-prova testados utilizando o contato esfera-plano apresentaram maior dependência do nível de carga.

9.
International Eye Science ; (12): 1798-1802, 2023.
Article in Chinese | WPRIM | ID: wpr-996887

ABSTRACT

AIM: To explore the differences of corneal biomechanical parameters, serum Leptin and extracellular superoxide dismutase(ecSOD)levels in patients with non-proliferative diabetic retinopathy(NPDR)or proliferative diabetic retinopathy(PDR).METHODS: This article is a prospective study. A total of 118 patients with type 2 diabetes mellitus(T2DM)and diabetic retinopathy(DR)who were admitted to our hospital from May 2020 to May 2022 were selected, and they were divided into NPDR group(n=57)and PDR group(n=61)according to the degree of lesion. Another 54 patients with T2DM but no retinopathy and 52 healthy individuals were set as NDR group and control group. Then the differences in the corneal biomechanics measured with [central corneal thickness(CCT), intraocular pressure(IOP), spherical equivalent(SE), the first applanation time(A1T), the first applanation length(A1L), deformation amplitude(DA)] and serum Leptin and ecSOD levels were analyzed, and multivariate Logistic regression analysis was conducted to analyze the high-risk factors affecting the occurrence of PDR.RESULTS: The CCT, IOP and A1T in PDR and NPDR groups were higher than those in control and NDR groups, and DA was lower than those in control and NDR groups(all P<0.05), and the CCT, IOP and A1T in the PDR group were higher than those in the NPDR group(all P<0.05). The levels of serum Leptin and ecSOD in PDR group, NPDR group and NDR group were higher than those in the control group(all P<0.05). The course of DM, CCT, IOP, A1T, and serum Leptin and ecSOD levels between NPDR group and PDR group were statistically significant(all P<0.05). Multivariate Logistic regression analysis denoted that DM course, CCT, IOP, A1T, Leptin, and ecSOD are risk factors that affect the occurrence of PDR, while DA is a protective factor that affects the occurrence of PDR(all P<0.05). CONCLUSION: CCT, IOP and levels of serum Leptin and ecSOD in PDR patients were significantly increased compared to those in the NPDR patients, while DA was significantly reduced. Furthermore, CCT, IOP, A1T and levels of serum Leptin and ecSOD were risk factors affecting the occurrence of PDR, while DA was a protective factor affecting the occurrence of the PDR.

10.
International Eye Science ; (12): 1793-1797, 2023.
Article in Chinese | WPRIM | ID: wpr-996886

ABSTRACT

AIM:To evaluate the changes in corneal biomechanics of patients with moderate refractive error after receiving small-incision lenticule extraction(SMILE)and femtosecond laser-assisted laser in situ keratomileusis(FS-LASIK)using the corneal visualization Scheimpflug technology(Corvis ST).METHODS:Prospective cohort study. A total of 65 moderate myopia patients(65 eyes)who were scheduled to undergo refractive surgery at the Ophthalmic Refractive Surgery Center of the Ningxia Eye Hospital from November 2020 to November 2021 were included in the study, and there were 30 eyes in the SMILE group and 35 eyes in the FS-LASIK group. The changes in corneal biomechanical parameters, including integrated radius(IR), inverse concave radius(ICR), deformation amplitude ratio 2mm(DAR2), stiffness parameter at first applanation(SP-A1), ambrosio relational thickness(ARTh)and the central curvature radius at highest concavity(HC-Radius)were observed by Corvis ST between both groups preoperatively and 1 and 3mo postoperatively.RESULTS: There were no statistical significance in biomechanical parameters between two groups of patients 1 and 3mo postoperatively(P>0.05). IR, ICR and DAR2 of each groups of patients 1 and 3mo postoperatively were significantly increased than those preoperatively, and SP-A1, ARTh and HC-Radius were significantly decreased than those preoperatively(all P<0.05). The biomechanical parameters at 1mo and 3mo postoperatively showed no statistical significance(P>0.05). In addition, a positive correlation was found between central corneal thickness(CCT)and ARTh and SP-A1 of the two groups of patients at 3mo postoperatively(FS-LASIK group: r=0.727, 0.819, SMLIE group: r=0.683, 0.434, all P<0.05), while a negative correlation was found between CCT and IR and ICR at 3mo postoperatively.(FS-LASIK group: r=-0.697, -0.622, SMLIE group: r=-0.447, -0.491, all P<0.05).CONCLUSION:For patients with moderate myopia, both SMILE and FS-LASIK can reduce corneal biomechanical stability. Both surgeries showed no significant differences in the effect on biomechanical, and the biomechanical has been stabilized at 1mo postoperatively. A correlation was found between postoperative CCT and ARTh, SP-A1, IR and ICR.

11.
Malaysian Journal of Medicine and Health Sciences ; : 325-339, 2023.
Article in English | WPRIM | ID: wpr-996577

ABSTRACT

@#Medical implants are normally used in clinical practice to treat most orthopaedics situations involving bone fractures, deformities, dislocation, and lengthening. It should be noted that specific measures regarding biomechanical and biomaterial characteristics are required for a successful post-surgery procedure. Biomechanical evaluations on the medical implants could be performed by utilising computer and engineering technology. One of them is in silico studies using finite element method that could be simulated in high-performance computer. However, various assumptions are required in computer simulation, such as the constraints on data input and computer resources. This review paper discusses current approaches of constructing a finite element model of human bone with specific material properties for upper limb such as the shoulder joint, humerus, elbow joint, radius and wrist joint. Previous related literatures were reviewed from selected keywords and search engines. To narrow the literature search in this study, inclusion and exclusion criteria of the literature searching were applied. We looked at the current level of knowledge in this field and offered recommendations for future study. In conclusion, studies from previous literature have demonstrated several ways for developing mathematical models and simulating medical implants.

12.
Journal of Acupuncture and Tuina Science ; (6): 203-209, 2023.
Article in Chinese | WPRIM | ID: wpr-996146

ABSTRACT

Objective:To observe the efficacy of traditional Qigong exercise combined with Tuina(Chinese therapeutic massage)manipulations in treating lower cervical disc herniation(CDH).Methods:A total of 120 CDH patients who met the inclusion criteria were randomly divided into an observation group and a control group,with 60 cases in each group.Patients in both groups were given the same Tuina manipulations.In addition,patients in the observation group practiced traditional Qigong exercise,and those in the control group did conventional neck exercise.After 8 weeks of treatment,the efficacy of the two groups was observed.Follow-up was conducted 3 months after the end of the treatment to record any recurrence.Results:The total effective rate of the observation group was higher than that of the control group(P<0.05).The improvement in symptom scores was more significant in the observation group than in the control group(P<0.05).There was inter-group statistical significance in comparing the cross-sectional area and fatty infiltration of certain cervical muscles(P<0.05).In addition,the recurrence rate in the observation group was lower than that in the control group(P<0.05).Conclusion:On the basis of the same Tuina manipulation treatment,the efficacy of traditional Qigong exercise in treating CDH is superior to that of conventional neck exercise,with more significant improvements in pain and quality of life and a lower recurrence rate.

13.
Chinese Journal of Orthopaedics ; (12): 1041-1049, 2023.
Article in Chinese | WPRIM | ID: wpr-993537

ABSTRACT

Objective:To compare the biomechanical characteristics of screw only spatial weaving fixation and calcaneal plate fixation in calcaneal fractures.Methods:Sanders type III calcaneus fracture model was established by using calcaneus model specimens: the physiological model group were the normal calcaneal models; the steel plate group were conventional steel plate fixation fracture models; the metal screw group were fracture models with only metal screw weaving fixation; seven and nine absorbable screw spatial weaving groups (seven absorbable screw group, nine absorbable screw group) were used to weave and fix fracture models with seven and nine absorbable screws. Cyclic test and mechanical compression test were carried out, and load-displacement curves were recorded. The material properties of metal screw spatial weaving and calcaneal anatomical plate system were replicated, finite element fracture models were established, and the calcaneal internal fixation models of plate screw group and spatial weaving screw group were completed by reverse processing. The changes of biomechanical characteristics of calcaneal bone in human (70 kg) standing on one foot were simulated, and the distribution of structural strength was analyzed by Von Mises equivalent stress cloud diagram and displacement cloud diagram.Results:In the cyclic test of 20-200 N load, the physiological model group, the plate group, the metal screw group, the absorbable 7 screw group, the absorbable 9 screw group were 0.87±0.22, 0.82±0.08, 0.70±0.12, 1.04±0.13 and 0.83±1.76 mm, the difference in model gap was statistically significant ( F=3.16, P=0.037). Among them, the absorbable 7 screws group was larger than the metal screws group ( t=4.28, P=0.003), and the other pin-two comparisons were not statistically significant ( P>0.05). The deformation of the five groups was 0.37±0.06, 0.38±0.07, 0.38±0.06, 0.52±0.07 and 0.42±0.07 mm, and the difference was statistically significant ( F=4.39, P=0.010). The deformation of absorbable 7 screws group was greater than that of physiological model group, the plate group and metal screw group ( t=3.69, P=0.006; t=3.25, P=0.012; t=3.51, P=0.008). In static test, compression displacement was 7.14±0.79, 7.30±0.66, 6.95±0.28, 8.19±0.61 and 7.16±0.55 mm, the difference was statistically significant ( F=3.28, P=0.032). The displacement of the absorbable 7 screws group was greater than that of the metal screws group ( t=4.13, P=0.003). The stiffness changes were 570.60±122.62, 512.86±80.77, 497.40±66.50, 456.21±58.19 and 560.39±94.40 N/mm, respectively, with no statistical significance ( F=1.44, P=0.258). The results of finite element analysis showed that under 3 500 N axial pressure load, the maximum compression displacement and stiffness of the plate and screw set were 6.47 mm, 540.96 N/mm, and the Von Mises equivalent stress peaks were 450.31 and 353.15 MPa, respectively. The maximum compression displacement and stiffness of the braided screw group were 5.25 mm, 666.67 N/mm, and the peak Von Mises equivalent stress of the screw was 396.20 MPa. Conclusion:Compared with lateral plate fixation, spatial weaving fixation can provide sufficient biomechanical stability for calcaneal healing and is superior to plate fixation in terms of structural stability, which may help to improve the effectiveness of calcaneal fracture fixation.

14.
Chinese Journal of Medical Education Research ; (12): 99-103, 2023.
Article in Chinese | WPRIM | ID: wpr-991261

ABSTRACT

Objective:To simulate the biomechanical characteristics of the real human thoracic cavity with a multi-spring group variable damping structure, and to design a new cardiopulmonary resuscitation training manikin based on the simulated thoracic biomechanical characteristics combined with the original electronic feedback system, and to test its application effect in cardiopulmonary resuscitation (CPR) teaching.Methods:A total of 60 undergraduate students majoring in five-year clinical medicine of Batch 2019 in Naval Medical University were selected as the research objects and were randomly divided into the experimental group and the control group, with 30 students in each group. The control group used the traditional manikin for CPR training, and the experimental group used the new type of manikin for CPR training based on the control group. After the training, the two groups of personnel were assessed for single skill. The single skill was mainly manual CPR operations, including artificial respiration and chest compressions. The theory and skill operation assessment of CPR and satisfaction for teaching method in the two groups were compared. SPSS 23.0 was used for statistical analysis.Results:The students in the experimental group scored (54.33±3.09) points in the single skill operation assessment, which were significantly better than that of the students in the control group [(52.33±3.08) points], and the difference was statistically significant ( P<0.05). The follow-up questionnaire showed that the students in the experimental group had a better evaluation of the teaching and training effect of the new type of manikin. Conclusion:Compared with the traditional manikin, the new CPR manikin can simulate the CPR emergency scene of the real human body, which can effectively improve the CPR teaching effect of standardized training for medical students, and help the standardization, normalization, and popularization of CPR technology in China.

15.
Journal of Medical Biomechanics ; (6): E451-E457, 2023.
Article in Chinese | WPRIM | ID: wpr-987970

ABSTRACT

Dendritic cells (DCs) are now known as the most powerful antigen-presenting cells in vivo, with efficient antigen uptaking, and processing capabilities. They can present antigens to naïve T cells in secondary lymphoid tissues, thereby induce immune response or tolerance, and play a key role in initiating and amplifying innate and adaptive immunity. DCs experience complex chemical and mechanical microenvironment changes and show different mechanophenotypes and immunophenotypes in the process of exerting their physiological functions. Deeply understanding the chemical and mechanical factors that regulate the mechanophenotypes and immunophenotypes of DCs is a prerequisite for using DCs to treat immune related diseases. In this review, the progress in the biomechanics and mechanobiology research of DCs was mainly introduced, and their potential applications and future development directions in the treatment of immune related diseases were explored.

16.
Journal of Medical Biomechanics ; (6): E420-E432, 2023.
Article in Chinese | WPRIM | ID: wpr-987968

ABSTRACT

The cardiovascular system plays a crucial role in the entire organism. It performs many important functions, such as providing organs and tissues with nutrients, hormones, delivering oxygen to cells, and maintaining physiological temperature. For a long time, accurately identifying the nonlinear and anisotropic mechanical properties of the vascular wall within the body has been regarded as a key challenge in cardiovascular biomechanics, as these properties are critical determinants of overall cardiac function. Currently, the roles of mechanical and tissue properties in cardiovascular diseases such as arterial aneurysms and atherosclerosis remain hot topics in both basic and clinical researches. This review aims to summarize the latest research advances in the field of cardiovascular biomechanics and mechanobiology in the year 2022. In terms of cardiovascular biomechanics, researchers focus on the structure, function, and pathophysiology of the cardiovascular system, and use experimental methods such as mechanical modeling to study these issues. These include studies about biomechanical properties of diseases such as atherosclerosis, arterial aneurysms, and myocardial infarction, as well as the development and testing of treatment methods based on dynamics of the cardiovascular system. In terms of mechanobiology, researchers explore mechanical properties of cardiovascular cells and extracellular matrix, including prediction of cell mechanical properties based on machine learning, studies of biological material mechanical properties, and the role of mechanical properties in cardiovascular cell phenotype changes. These research findings provide new ideas and methods for diagnosing and treating cardiovascular diseases and offer new insights into researches in biomechanics and mechanobiology fields.

17.
Journal of Medical Biomechanics ; (6): E408-E414, 2023.
Article in Chinese | WPRIM | ID: wpr-987966

ABSTRACT

Mechanical stimulation in micro-environment ( such as matrix stiffness, surface topography, cyclical stretch) can be perceived by macrophages through receptors on cell membrane, transmitted to the nucleus along the adhesion protein molecular chain and cytoskeleton, and also converted into biochemical signal to stimulate gene transcription. Mechanical stimulation drives various biological functions in macrophages, such as adhesion, proliferation, migration, and polarization, thereby playing a corresponding role in disease progression and tissue regeneration. This study demonstrates the role of micro-environment mechanics in macrophages polarization and function, and elucidates the related mechanism of mechanotransduction pathway in macrophages, so as to provide molecular biomechanics insights into the development of macrophage-targeting immunomodulatorybiomaterials.

18.
Journal of Medical Biomechanics ; (6): E396-E401, 2023.
Article in Chinese | WPRIM | ID: wpr-987964

ABSTRACT

The rotator cuff is an important structure to maintain movement and dynamic stability of the shoulder joint. Rotator cuff injury changes its unique biomechanical effects, resulting in shoulder pain and mobility disorders. Although great progress has been made in suture technology and fixation method, the rate of postoperative retear is still very high. Understanding the biomechanical mechanism of normal rotator cuff and restoring the special biomechanical effect of rotator cuff after injury are the key to prevent postoperative retear. This article reviewed biomechanical researches on rotator cuff repair in recent years, in order to provide some theoretical guidance for clinical operation.

19.
Journal of Medical Biomechanics ; (6): E195-E201, 2023.
Article in Chinese | WPRIM | ID: wpr-987935

ABSTRACT

Idiopathic pulmonary fibrosis (IPF) is a common chronic interstitial fibrotic disease. During the fibrosis process, myofibroblasts are abnormally activated, collagen is deposited in large quantities and the biomechanical characteristics of lung tissue are significantly altered. In this paper, a systematic review about the changes in lung tissues, cellular biomechanical properties and biomechanical signals during the process of IPF was presented, and the in vitro reproduction of biomechanical features and therapeutic strategies for targeting biomechanics wassummarized, so as to provide references for clinical prevention and treatment of IPF.

20.
Journal of Medical Biomechanics ; (6): E170-E175, 2023.
Article in Chinese | WPRIM | ID: wpr-987931

ABSTRACT

Objective To investigate the age-related changes of biomechanical properties for humerus, femur and tibia in male rats and their application values in age estimation. Methods According to different weeks of age, 90 healthy male SD rats were divided into 2, 4, 6, 8, 17, 26, 52, 78 and 104-week groups with 10 rats in eachgroup. After the rats were executed by excessive anesthesia, humerus, femur, and tibia were separated and the attached soft tissues were removed. The length of the above-mentioned bones and the diameter of the middle section (compression site) were measured with vernier caliper, and the three-point bending test was conducted with electronic universal material testing machine to detect the ultimate load and displacement under ultimate load. Results There were significant differences in the ultimate load of humerus, femur and tibia among male rats in different age groups (P<0. 05). With the increase of week age, the ultimate loads of the humerus, femur and tibia increased first and then decreased, and reached the peak value in 52-week age group, showing a strong positive correlation with week age before 52 weeks ( r = 0. 884,0. 933,0. 929, P<0. 05). There was no significant difference in humerus and tibia. The displacement of femur under ultimate load was weakly positively correlated with week age (R= 0. 406,P<0. 05). The age prediction accuracy for automatic linear modeling of ultimate load for humerus, femur, tibia and three above-mentioned bones in rats before 52-week age was 78. 2% , 86. 8% , 84. 1% and 88. 3% , respectively. There was a strong positive correlation between the length of humerus, femur and tibia and the ultimate load (R= 0. 904, 0. 897, 0. 814, P<0. 05). The diameters of humerus, femur and tibia were strongly positively correlated with the ultimate load (R = 0. 759, 0. 814 and 0. 745, P<0. 05). Conclusions The ultimate loads of humerus, femur and tibia in male rats increased first and then decreased with age, and were positively correlated with age before 52 weeks, which could be used for age inference. The highest accuracy of age estimation was ultimate loads of three bones, followed by femur. The length/ middle diameter of humerus, femur and tibia were strongly positively correlated with the ultimate load.

SELECTION OF CITATIONS
SEARCH DETAIL