1.
Zhongguo Yi Liao Qi Xie Za Zhi ; (6): 237-241, 2023.
Article in Chinese | WPRIM | ID: wpr-982220

ABSTRACT

Biology-guided radiotherapy (BgRT) is a novel technique of external beam radiotherapy, combining positron emission tomography-computed tomography (PET-CT) with a linear accelerator (LINAC). The key innovation is to utilize PET signals from tracers in tumor tissues for real-time tracking and guiding beamlets. Compared with a traditional LINAC system, a BgRT system is more complex in hardware design, software algorithm, system integration and clinical workflow. RefleXion Medical has developed the world's first BgRT system. Nevertheless, its actively advertised function, PET-guided radiotherapy, is still in the research and development phase. In this review study, we presented a number of issues related to BgRT, including its technical advantages and potential challenges.


Subject(s)
Positron Emission Tomography Computed Tomography , Radiotherapy Planning, Computer-Assisted/methods , Algorithms , Particle Accelerators , Biology , Radiotherapy, Image-Guided/methods , Radiotherapy Dosage
2.
Article in Chinese | WPRIM | ID: wpr-993181

ABSTRACT

Objective:To analyze the differences in dosimetric quality and plan complexity of volumetric modulated arc therapy (VMAT) plans based on Halcyon 2.0 and Truebeam for different treatment sites of the patients.Methods:Halcyon 2.0 VMAT plans in head & neck, chest, abdomen, and pelvis treatment sites of 49 cases were retrospectively selected and the VMAT plans were re-designed based on Truebeam with the same optimization parameters. The differences in dosimetric metrics and plan complexity between the two types of plans were compared and analyzed. P<0.05 was considered as statistically significant. Results:In terms of PTV, Halcyon 2.0 plans showed better homogeneity index (HI), conformal index (CI) in the head & neck and chest. Besides, Halcyon 2.0 plans yielded better D 98% and CI in the abdomen and better D 2% in the pelvis. For organs at risk (OAR), the D 20% and D mean of bilateral lungs, and D meanof heart for Halcyon 2.0 plans in the chest were lower than those for Truebeam plans (all P<0.05). For the complexity metrics, the median average aperture area variability (AAV) of Halcyon 2.0 plans in the head & neck, abdomen and pelvis were 0.414, 0.425 and 0.432, which were better than 0.385, 0.368 and 0.361 of Truebeam plans in the corresponding sites, respectively. In the abdomen and pelvis, Halcyon 2.0 plans showed better median modulation complexity score (MCS) than Truebeam plans (0.320 vs. 0.268, 0.303 vs. 0.282; both P<0.05). The median small aperture score (SAS) for all plans of Halcyon 2.0 were better than that of Truebeam plans (all P<0.05), and the median plan average beam area (PA) of all plans of Halcyon 2.0 were larger than that of Truebeam plans (all P<0.05). Conclusions:Compared with conventional fractionated VMAT plans based on Halcyon 2.0 and Truebeam, Halcyon 2.0 plans have similar or even better dosimetric quality. However, Halcyon 2.0 plans have lower plan complexity, which makes it an advantage in clinical application.

3.
Article | IMSEAR | ID: sea-222196

ABSTRACT

Jugular foramen schwannomas (JFS) are rare benign tumors located in the jugular foramen. They can present with various symptoms depending on the extent of involvement of the tumor such as hearing loss, tinnitus, headache, and ataxia. Surgical resection has been considered as the primary treatment option for JFS. Stereotactic radiosurgery (SRS) offers an equally good treatment in patients with small and residual tumors after surgery with the advantage of being non-invasive with minimal complication rates. Herein, we present a rare case of JFS treated by SRS in our institution.

4.
Article in Chinese | WPRIM | ID: wpr-932704

ABSTRACT

Objective:To analyze the duration of each phase of Unity MR-linac in clinical application, aiming to provide reference for clinical optimization of the process time.Methods:Clinical data of 55 patients treated with Unity MR-linac were retrospectively analyzed. All patients were divided into the adapt to position (ATP) and adapt to shape (ATS) groups according to the planning method. The duration of each phase in the treatment process, the name and the time of each sequence, the number of beams, segments and total monitor units (MUs) were recorded and compared between two groups. In addition, the set-up time was counted according to different treatment sites. The time of each sequence and set-up time were expressed as the median M (Q 1, Q 3), and the number of beams, segments and total MUs of each plan were described as the mean±SD. Results:42 patients underwent ATP with a total of 305 treatment sessions: setup time was 3(2, 5) min, MR scanning time was 5(4, 7) min, registration time was 3(3, 4) min, adaptive planning time was 8(4, 12) min, beam on time was 8(6, 11) min, and the total time was 30(25, 36) min. 13 patients received ATS with a total of 65 treatment sessions: setup time was 2(2, 3) min, MR scanning time was 7(5, 8) min, registration time was 4(3, 5) min, time of delineation of target and organs at risk was 12(9, 16) min, adaptive planning time was 11(10, 14) min, beam on time was 10(9, 11) min and the total time was 55(49, 61) min. The set-up time according to treatment sites was 4(2, 4) min in the head and neck, 2(2, 4) min in the chest, and 3(2, 5) min in the abdomen. The number of fields, segments and total MUs during ATP were 8.1±1.7, 49.9±31.2, 846.75±363.44 in the head and neck, 8.0±2.0, 60.7±13.3, 790.21±279.00 in the chest, and 9.7±2.0, 81.2±22.3, 2007.32±1053.81 in the abdomen, respectively. The number of fields, segments and total MUs during ATS in head and neck of one case were 13, 39, 993.07, and 9.5±1.5, 65.5±6.3, 2763.26±835.41 in the abdomen.Conclusions:MR-guided radiotherapy yields huge potential in clinical application. However, there is still much room for the improvement of shortening the process duration.

5.
Article in Chinese | WPRIM | ID: wpr-956802

ABSTRACT

Objective:To analyze the dosimetric effects on off-center tumour treatment plan resulting from the MR-Linac-based isocenter position radiotherapy plan.Methods:The cases of 19 patients who were treated in Sun Yat-sen University Cancer Center in 2020 were collected in this study. Two different IMRT plans were designed for each patient with off-center tumor both for group A with planned isocenter position as IMRT and group B with planed target center position as geometric center. The conformity index and homogeneity index of target, the dose normal tissue and the number of MU were compared between two plans.Results:The two IMRT plans met clinical dosimetric requirements. No statistical differences were found both in homogeneity index and conformity index ( P>0.05). Also there was no differences found in doses to normal tissues. However, the MU number (1 149±903, t=2.804, P=0.012) in group A was higher than that in group B (970±652). Conclusions:It is feasible to perform MR-Linac-based off-center treatment plan.

6.
Article in Chinese | WPRIM | ID: wpr-956846

ABSTRACT

Objective:To study the clinical feasibility and advantages of the RapidPlan module based on Halcyon 2.0 ring medical linear accelerator in the design of volumetric modulated arc therapy (VMAT) plans after cervical cancer surgery.Methods:The data of 98 clinical cervical cancer cases were selected from the database, and VMAT artificial radiotherapy plans were designed based on Halcyon 2.0. Then, the designed plans were imported into the RapidPlan module to train the module for a prediction model with high goodness of fit. Another 20 patients after cervical cancer surgery were selected as the validation set to compare the differences in dosimetry, plan consistency, and plan execution efficiency between the manual plans and RapidPlan automatic plans.Results:The RapidPlan automatic plans could obtain dose distribution of target volume and organs at risk with the same quality as the manual plans. The RapidPlan automatic plans provided slightly inferior protection of the femoral head but superior protection of the spinal cord compared to the manual plans, and the difference was statistically significant ( t = 4.71, P<0.001). The average MU of the RapidPlan automatic plans was 687.46, which was lower than that of the manual plan (815.34), and the difference was statistically significant ( t = 6.09, P < 0.05). The portal dosimetry (PD) verification revealed that the average γ passing rate (1 mm/1%) of the RapidPlan automatic plans was 89.48%and that of the manual plans was 88.22%, and the difference was statistically significant ( t = 3.35, P < 0.05). Conclusion:RapidPlan automatic plans based on the Halcyon 2.0 platform can meet the clinical needs of the VMAT program for cervical cancer and has certain advantages.

7.
Article in Chinese | WPRIM | ID: wpr-956962

ABSTRACT

Objective:To investigate the workflow, feasibility and advantages of respiratory navigator-guided stereotactic body radiation therapy (SBRT) of liver malignancies on the magnetic resonance linear accelerator (MR-linac).Methods:Clinical data of 10 patients with liver cancer treated with respiratory navigator-guided SBRT on the MR-linac from September to December 2021 were analyzed retrospectively. All patients underwent CT and MR simulated localization, and plain, enhanced and 4D CT scan, and T 1 3D MR and T 2 3D MR images were collected. The expiratory 4D CT was chosen to design the reference plan. The T 2 3D navigator MR image (end-exhalation) was collected before treatment, the target position was adjusted or the target shape was modified in combination with the real-time monitoring 2D MR image and appropriate online adaptive planning process was selected. Then, the ability of CT, T 2 3D and T 2 3D navigator MR images to display the tumor was evaluated by naked eye. The changes of target volume were calculated. Dosimetric differences between the adaptive and reference plans were compared. The efficacy and adverse reactions of patients were evaluated. Results:In the free breathing state, the T 2 3D navigator MR image was significantly better than T 2 3D MR image to clearly display the tumor and its boundary. The adaptive plans of adapt-to-position (ATP) and adapt-to-shape (ATS) adopted by 10 patients was 37 times and 22 times respectively. The tumor subsided significantly in 3 patients. The average target conformal index (CI) of the adaptive plans was no different from that of the reference plans, but the gradient index (GI) was higher ( P<0.05), especially in the ATS plans. Compared to the reference plans, the normal liver V 5 Gy, V 10 Gy and D mean were almost the same, but the average MU was increased with a significant difference in the ATP adaptive plans ( P<0.05). The average of MU, segments and normal liver D mean and V 10 Gy in the ATS adaptive plans were lower than those in the reference plans, and the liver V 5 Gy was slightly increased. Seven patients were evaluated after 1 month and 3 months. The local control of lesions was promising. Toxicities were mild and no grade 3 or higher toxicities were observed. Conclusion:Respiratory navigator on MR-linac improves the visual clarity of tumors and online MR images, and shows its advantages to guide the adaptive precision radiotherapy of liver tumors, especially in SBRT.

8.
Article in Chinese | WPRIM | ID: wpr-993032

ABSTRACT

Objective:To compare three fixed-field intensity-modulated radiotherapy (IMRT) plans for nasal cavity and paranasal sinus tumors, including the coplanar IMRT (C-IMRT) plan and the non-coplanar IMRT(NC-IMRT) plan which were based on a conventional C-arm LINAC (Trilogy), and the coplanar IMRT (H-IMRT) plan based on an O-ring LINAC (Halcyon).Methods:Based on the data of 10 patients in the Ningbo First Hospital from December 2018 to December 2021 with nasal cavity and paranasal sinus tumors who underwent postoperative radiotherapy, this study redesigned three IMRT plans with the same prescribed doses and optimization objectives. Then, this study compared the doses of target volumes and organ at risks(OARs), the validation pass rates, and the execution time of these plans. Friedman test was employed in this study, and multiple comparisons were further made in cases of different results.Results:The differences in the conformal index (CI) of PTV and PTV boost of the three plans were statistically significant ( χ2 = 7.51, 9.69, P < 0.05). The multiple comparisons showed that the median CI of the H-IMRT plan was higher than that of the NC-IMRT plan ( Z = 2.53, 2.68, P < 0.05). The differences in other parameters of target volumes were not statistically significant. Compared with the C-IMRT plan, the H-IMRT plan reduced the Dmax of bilateral lenses, bilateral corneas, ipsilateral optic nerve, and ipsilateral eyeball ( Z = 2.80, 2.80, 2.80, 2.80, 2.81, 2.09, P < 0.05). Compared with the C-IMRT plan, the NC-IMRT reduced the Dmax of bilateral lenses, corneas, and eyeballs and contralateral optic nerve ( Z = 2.80, 2.66, 2.80, 2.70, 2.29, 2.29, 2.65, P < 0.05) and reduced the Dmean of bilateral eyeballs ( Z = 2.80, 2.80, P < 0.05). Compared with the NC-IMRT plan, the H-IMRT plan reduced the Dmax of the ipsilateral lens and cornea ( Z = 2.50, 2.08, P < 0.05), but increased the Dmax of the contralateral optic nerve and the Dmean of bilateral eyeballs ( Z = 2.80, 2.80, 2.80, P < 0.05). The validation pass rate of the three plans met the institutional standards, and the differences were not statistically significant. Moreover, the H-IMRT plan had the shortest median execution time (172.00 s), followed by the C-IMRT plan (337.50 s), and the NC-IMRT plan (388.00 s). Conclusions:The verification pass rate of the three plans can achieve the requirements of treatment implementation. The three plans had similar dosimetric differences in target volumes. However, the H-IMRT and NC-IMRT plans can protect the normal tissues (especially optical organs) more effectively than the C-IMRT plan, which is conducive to reducing the toxicity after radiotherapy and provides space for local dose increase or the radiotherapy for the treatment of tumor recurrence. The execution efficiency of the three plans is in the order of H-IMRT > C-IMRT > NC-IMRT. It is necessary to select appropriate radiotherapy equipment and technology according to actual situations.

9.
Article in Chinese | WPRIM | ID: wpr-910346

ABSTRACT

Objective:To investigate the feasibilityof the adaptive radiotherapy using high-field MR-Linac systems for head neck cancers and perform the evaluation of target coverage and dose criteria.Methods:This study investigated 128 treatment plans of six patients who were treated on 1.5T MR-Linacsystems in Sun Yat-sen University Cancer Center in 2019, compared the differences in target coverage and dose criteria between the dose accumulation in the adaptive radiotherapy using MR-Linac systems and the reference plans, and evaluated the target coverage and dose criteria of each fraction of adaptive plan based on daily MRI anatomy.Results:There was no significant change in the target coverage and dose criteria for each treatment fraction(<1%). However, the change of lens dose was significant (maximum 98%). In addition, the result showed that there was no significant difference in target coverage and dose criteria between the dose accumulation in adaptive radiotherapy using MR-Linac systems and reference plans.In contrast, the average dose to lens was increased by 31.7%.Conclusions:It is feasible to perform adaptive radiotherapy using 1.5T MR-Linacsystems for head neck cancers according tothe evaluation of target coverage and dose criteria. Additionally, since the actual dose tolens was quite different from the reference plan, the lens exposure should be considered in clinical practice.

10.
Article in Chinese | WPRIM | ID: wpr-910371

ABSTRACT

Objective:To investigate the impacts of electron streaming effect (ESE) on out-of-field dose distribution in 1.5 T MRI-guided radiotherapy.Methods:Firstly, the Monaco v5.40.1 (Elekta AB, Stockholm, Sweden) treatment planning system (TPS) was implemented to investigate the ESE in a square field (5 cm × 5 cm) at the entry and exit sides of a special homogeneous water phantom. Afterward, a retrospective investigation was conducted into one laryngeal cancer case and one breast cancer case who had been treated on a conventional linear particle accelerator (linac). Then doses were recalculated in the Monaco system using a Unity machine model. Meanwhile, the out-of-field skin dose enhancement induced by ESE was investigated.Results:ESE-induced dose variations were observed at both the entry and exit sides of the phantom surface in the presence of a magnetic field, with the ESE on the exit side notably stronger than that on the entry side. For the laryngeal cancer case, the ESE was not notable and had insignificant impacts on the out-of-field skin dose. In contrast, ESE-induced in-air high-dose region outside the body stretched to the chin area for the breast cancer case. This led to the skin dose escalation of the chin at D1 cm 3 454.6 cGy. After the application of 1 cm bolus, the corresponding skin dose of the chin D1 cm 3 reduced to as low as 113.6 cGy, which is almost equivalent to that in the absence of a magnetic field ( D1 cm 3=92.5 cGy). Conclusions:The ESE in a magnetic field can alter out-of-field dose and lead to local dose enhancement along the electron path. Although the ESE had insignificant impacts on the out-of-field dose of the laryngeal cancer case, it reached the chin area of the breast cancer case. ESE can be effectively shielded by adding protective bolus.

11.
Article in Chinese | WPRIM | ID: wpr-910450

ABSTRACT

Objective:To summarize the experience of ELEKTA Unity MR-linac in clinical application in our hospital and analyze the positioning accuracy, process time and other related issues.Methods:A total of 14 patients enrolled in the Unity MR-Linac study were reviewed. All treatment time (including positioning, scanning, replanning, and beam discharge) and setup errors in 3directions were statistically analyzed. 11 patients with conventional accelerators using the multifunctional immobilization system (MIS) were randomly selected to make statistical analysis of the setup errors, and the differences between the Unity group and the conventional accelerators using the MIS were compared using t-test. Results:In the Unity group, the setup errors in X, Y and Z directions were (-0.15±0.30) cm, (0.02±0.57) cm and (-0.10±0.28) cm, respectively. The average treatment time was 36.87minutes. The average positioning time was 5.40minutes. The mean scan time was 7.48minutes, the mean adaptive plan time was 7.46minutes, and the mean beam time was 9.48minutes. In the conventional accelerator group, the setup errors were (0.05±0.25) cm, (-0.01±0.25) cm and (-0.03±0.23) cm, respectively. The results of the setup errors of patients fixed with MIS showed that there were significant differences in the left and right directions ( P<0.001), while there were no significant differences in the Y and Z directions ( P=0.061 and 0.374) between two groups. Conclusions:Except in the X direction, there is no significant difference in setup errors between the Unity and conventional accelerator groups in the condition of laser-free system. Under smooth circumstances, the treatment time by using ATP (adapt to position) workflow will also be within the range of tolerance of the patients. Magnetic-guided radiotherapy has a promising application prospect, whereas the procedure needs to be optimized.

12.
Zhongguo Yi Liao Qi Xie Za Zhi ; (6): 109-113, 2021.
Article in Chinese | WPRIM | ID: wpr-880434

ABSTRACT

Clinically, beam matching can greatly improve the flexibility and efficiency of treating patients between different medical electron linacs. However, in addition to the regular quality assurance (QA) test of the machine performance of linacs, there is still a lack of comprehensive evaluation of the clinical radiotherapy performance of beam-matched linacs. In this paper, the performance of volumetric modulated arc therapy (VMAT) between three closely matched linacs was evaluated by statistical process control (SPC) technology. It was found that the average and median γ passing rates of the VMAT QA processes of the three linacs had little difference, but the process capability levels were at three different levels. The results show that SPC technology can effectively evaluate the performance of beam matching for medical electron linacs, improve the patient-specific VMAT QA processes, and guide clinical decision-making.


Subject(s)
Electrons , Particle Accelerators , Quality Assurance, Health Care , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated
13.
Article in Chinese | WPRIM | ID: wpr-755089

ABSTRACT

Objective To illustrate the basic operational principle of the control software item Part and value ( IPV) of Elekta digital medical linac and specifically explain that the control software monitors and controls the subsystems in a real-time manner by using three types of items and Parts. Methods Firstly, the composition of the control system of Elekta digital medical linac was introduced. Then, the definition and category of the items and Parts of the control software and the basic principle of different types of items were illustrated. Finally, the application of control software items and Parts in real-time monitoring and controlling the operation of subsystems was evaluated by analyzing the motion control of high-power ( HP) phase shifter. Results By analyzing the principle and citing a classical example to specifically illustrate the operational principle and application of control software IPVs, the users, especially the maintenance personnel, could master relevant theoretical knowledge, rapidly and accurately find the operational parameters during daily use and maintenance, besides analyze and resolve the problems based on the control principle of relevant subsystem. Conclusion Users, especially the maintenance personnel who master the working principle of these subprojects and their project sub-items can quickly and accurately check, calibrate the operating parameters via the control software, resolve equipment failure and avoid accidents caused by inappropriate operation in the daily use or maintenance.

14.
Article in Chinese | WPRIM | ID: wpr-734356

ABSTRACT

Objective To investigate the commissioning and testing of the Eclipse model of an Edge accelerator with high-definition muhi-leaf collimator (HD-MLC).Methods The percentage depth dose (PDD),profile,output factor measured by Razor and CC13 were statistically compared with the standard data.Penumbra,transmission factor (TF),leakage,concave-convex groove,accuracy of movement and dosimetry leaf gap (DLG) were measured with EBT3,electronic portal image device (EPID) and PTW SRS1000&SRS1500.The optimal DLG/TF was acquired when the γ pass rate of test cases was the highest.The point dose of regular fields,intensity-modulated radiation therapy (IMRT) and volume-modulated radiation therapy (VMAT) was verified with FC65-G.The planar dose of these case was verified with Octavius 4D and EBT3.Results The measured PDD data were consistent with the standard data.The measured penumbra of 3 cm and 4 cm square fields was smaller,whereas that of 6 cm square field was larger than the standard values.The left and right edge,field size,center of the field were distributed within the range of-1.0-0.4 mm、0.2-1.7 mm,-0.3-1.9 mm and-0.1-0.8 mm,respectively.The mean penumbra of the left and right MLC in different positions were (2.5±0.042) mm and (2.7±0.005) mm.The leakage of MLC was 0.009-0.016.The measured DLG/TF was 0.1861 cm/0.0116 and the optimal DLG/TF was 0.015 cm/0.014.The differences of point dose of all the test cases except the one which was in the low-dose area were within ±3%.Local and global γ pass rates of all IMRT were 79.81%-100% and 96.3%-100% (3%/3 mm),71.3%-98.9% and 94.3%-99.8% for VMAT cases.Conclusions This method can accurately test and commission the Eclipse treatment planning model of Edge Linac equipped with HD-MLC.

15.
Article in Chinese | WPRIM | ID: wpr-745253

ABSTRACT

Objective To establish and evaluate a morning check system for linac based on electronic portal image device (EPID).Methods Delivered fluence maps of open and wedge fields at 10 cm×10 cm field size of Synergy Linac were measured by EPID.Figure features from these two images were extracted with matlab codes and analyzed to realize a quick morning check.The repeatability of dose response and mechanical setup,relationship between gray value and machine unit (MU),accuracy of output and field size test were investigated with both EPID and DailyQA3.The status of Synergy linac was monitored both by DailyQA3 and EPID for two months.Results EPID was able to test the linac consistently with a testing error of 0.50 mm,1.00 mm for field size and center,respectively.Both of the test accuracy for flatness and symmetry was 0.17%.The mechanical accuracy test and dosimetric repeatability test were also consistent.The dose response of EPID was linearly related to the linac output (R2>0.999).EPID was highly sensitive to the change of output and radiation field size.The measurement deviations between EPID and DailyQA3 were consistent and within clinical acceptable tolerance.Conclusions EPID showed great accuracy and stability on monitoring the performance of linac.The established daily check tool based-on EPID is accurate and reliable for clinical usage.

16.
Article in Chinese | WPRIM | ID: wpr-495525

ABSTRACT

Objective To establish a novel Monte Carlo simulation method for reconstruction of medical accelerator model and X?ray energy spectrum based on IAEA Varian 6 MV X?ray phase?space file and photon energy spectrum of the target accelerator. Methods The verified 6 MV X?ray phase?space files were preprocessed to elevate the energy of each particle. Particles were saved in different Phase?Space?Let ( PSL) files according to their position and energy, yielding an initial photon energy spectrum for Monte Carlo simulation of accelerator under an initial target energy. The initial photon energy spectrum was fit to a photon energy spectrum of an accelerator ( Elekta Precise 10 MV X?ray accelerator) under an unknown target energy to yield a fitting coefficient, which was the weight of each PSL. Finally, an accelerator model under an unknown target energy was reconstructed using the initial PSL files and the weight information. The percentage depth dose ( PDD) distribution was calculated in different square open fields. The effectiveness of this method was verified using one dimensional gamma passing rate. Results The peak position and overall distribution of the reconstructed 10 MV photon energy spectrum were in accordance with those of the verified 10 MV photon energy spectrum. The PDD calculated from the reconstructed 10 MV accelerator model agreed well with the measured PDD. The one?dimensional gamma passing rate was above 96%( 1%/1 mm, threshold=0%) . Conclusion The Monte Carlo reconstruction method proposed in this study is reliable, accurate, and effective.

17.
Article in Chinese | WPRIM | ID: wpr-469681

ABSTRACT

Objective To verify the daily delivery accuracy of volumetric-modulated arc therapy (VMAT) and achieve the process quality control (PQC) of linac using statistical process control (SPC)technology.Methods The log files of all treatments were taken out from the linac system.An in-house software which created by Matlab 7.14 was used to analyze the daily parameters accuracy and the mechanism and dose delivery accuracy of the linac for each VMAT,and an daily evaluation report was automatically created for the linac.The stability of the linac and the deviation of the delivery accuracy for various cancer sites were also analyzed.To achieve the process quality control of hnac using SPC technology,the control limit of each parameter was calculated by Johnson alternation and the single value control charts were drawn.Results 76 patients mainly with nasopharyngeal carcinoma,cervical carcinoma,rectal cancer and laryngeal cancer,got the treatment daily with VMAT technology,and a total of 2 446 arcs were delivered by the linac in continuous 16 days.The gantry angle error,y and x collimator position error,MLC leaf position error and dose delivery error were 0.49°,0.09 mm,0.38 mm,0.31 mm,0.05 MU,respectively.Compare to the nasopharynx,uteri,rectal and larynx cancer,it can be seen that the variation factors of dose delivery and gantry angle errors for various cancer sites were higher,which was 8.10% and 4.54%,respectively.Through the process quality control of the linac,it was found that all the parameters were in control.While some abnormal points arose (the error was greater than UCL),and the ratio of the gantry angle which was out of control (0.45%) was the highest in all parameters.Conclusions linac delivery accuracy could be monitored and verified during the whole VMAT treatment for each patient,and the daily running condition of linac could be monitored.Through the introduction of SPC technology and the control charts,the process quality control of linac in VMAT could be achieved.It is a financial and valid method for the daily quality assurance of linac.

18.
Article in Chinese | WPRIM | ID: wpr-489092

ABSTRACT

Objective To explore the clinical efficacy of early surgery combined with electron linac therapy on keloid.Methods The keloid patients with stable phase were selected;complete resection of keloid and relaxation suture were performed;after the surgery within 24 hours 6 MeV with Varian 2300CD radiotherapy was given,each measuring 4 Gy,total dose of 20 Gy.Results 860 cases of patients were colected for a period of 3 months to 36 months of regular follow-up,which recovered in 802 cases (cure rate was 93.26%),effective results were observed in 41 cases (effective rate of 4.77%),including 17 cases of recurrence (recurrence rate 1.98%),the total efficiency (cure plus effective) was 98.02%.Conclusions More accurately immediate radiotherapy after surgery can effectively reduce the recurrence rate,which is a safe and effective method in the treatment of keloids.

19.
Rev. Assoc. Med. Bras. (1992, Impr.) ; Rev. Assoc. Med. Bras. (1992, Impr.);54(2): 167-172, mar.-abr. 2008. ilus, tab
Article in English | LILACS | ID: lil-482910

ABSTRACT

OBJECTIVE: To evaluate results achieved with radiosurgery and complications of the procedure when treating arteriovenous malformations with linear accelerator. METHODS: This retrospective study was conducted between October 1993 and December 1996. Sixty-one patients with arteriovenous malformations were treated with radiosurgery utilizing a 6MV energy linear accelerator. Ages of the 32 female and 29 male patients ranged from 6 to 54 years (mean: 28.3 years). The most frequent initial symptom was cephalea (45.9 percent), followed by neurological deficit (36.1 percent). Cerebral hemorrhage diagnosed by image was observed in 35 patients (57.3 percent). Most arteriovenous malformations (67.2 percent) were graded Spetzler III and IV. Venous stenosis (21.3 percent) and aneurysm (13.1 percent) were the most frequent angioarchitecture changes. The dose administered varied from 12 to 27.5Gy in the periphery of the lesion. RESULTS: Out of twenty-eight patients that underwent conclusive angiography control, complete obliteration was achieved in 18 (72 percent) and treatment failed in 7 (absence of occlusion with more than 3 years of follow-up). Four were submitted to a second radiosurgery, and one of these has shown obliteration after 18 months of follow-up. DISCUSSION: Several factors were analyzed regarding the occlusion rate (gender, age, volume, localization, Spetzler, flow, embolization, total of isocenters, prescribed dose and chosen isodose) and complications (total of isocenters, localization, volume, maximum dose, prescribed dose and chosen isodose). Analyzed variables showed no statistical significance for obliteration of the vessel, as well as for treatment complications. The largest diameter of the arteriovenous malformation, its volume and the dose administered did not influence time of obliteration. CONCLUSION: Radiosurgery is effective in the treatment of arteriovenous malformations and can be an alternative for patients with clinical...


OBJETIVO: Analisar os resultados obtidos com radiocirurgia e as suas complicações do procedimento, no tratamento das malformações arteriovenosas com acelerador linear. MÉTODOS: Este é um estudo retrospectivo. Entre Outubro de 93 e Dezembro de 96, sessenta e um pacientes com malformações arteriovenosas foram tratados, utilizando um acelerador linear com 6MV de energia. As idades variaram de 6 a 54 anos (média: 28,3 anos), 32 pacientes mulheres e 29 pacientes homens. O sintoma inicial mais freqüente foi cefaléia (45,9 por cento), seguido de déficit neurológico (36,1 por cento). Hemorragia cerebral diagnostica por exame de imagem foi observada em 35 pacientes (57,3 por cento). A maioria das malformações arteriovenosas (67,2 por cento) eram graus III e IV de Spetzler. Estenose venosa (21,3 por cento) e aneurisma (13,1 por cento) foram as mais freqüentes alterações da arquitetura vascular. A dose administrada variou de 12 a 27,5Gy na periferia da lesão. RESULTADOS: Dos vinte e oito pacientes que se submeteram a controle angiográfico conclusivo, 18 tiveram obliteração completa (72 por cento) e 7 falharam ao tratamento (ausência de oclusão com mais de três anos de seguimento). Quatro pacientes foram submetidos a uma segunda radiocirurgia, e um paciente deste grupo apresentou obliteração em 18 meses de seguimento. DISCUSSÃO: Vários fatores foram analisados em relação ao grau de oclusão (sexo, idade, volume, localização, Spetzler, fluxo, embolização, total de isocentros, dose prescrita e isodose escolhida) e complicações (total de isocentros, localização, volume, dose máxima, dose prescrita e isodose escolhida). As variáveis analisadas não mostraram significância estatística para a obliteração do vaso, bem como para as complicações de tratamento. O maior diâmetro da malformação arteriovenosa, seu volume e a dose administrada não influenciaram no tempo de obliteração. CONCLUSÃO: Radiocirurgia é eficiente no tratamento das malformações arteriovenosas...


Subject(s)
Adolescent , Adult , Child , Female , Humans , Male , Middle Aged , Young Adult , Intracranial Arteriovenous Malformations/surgery , Particle Accelerators , Radiosurgery/methods , Cerebral Hemorrhage/diagnosis , Dose-Response Relationship, Radiation , Epidemiologic Methods , Magnetic Resonance Angiography , Radiosurgery/adverse effects , Radiosurgery/mortality , Treatment Outcome , Young Adult
20.
Article in Korean | WPRIM | ID: wpr-187031

ABSTRACT

The energy spectra and dose calculations were performed for secondary neutrons from a 24 MV LINAC using MCNPX code (V2, 4, 0). The energy spectra for neutrons and photons emitted from the LINAC head, and absorbed dose to water were calculated in water phantom. The absorbed doses calculated with Monte Carlo were 0.66~0.35 mGy/photon Gy at the surface to d=5 cm, and calculated with interaction data was 0.52 mGy/photon Gy at the depth of electron equilibrium in water. We have shown that this work can be applied to dose estimation of neutrons from high energy LINAC through the comparison of our results with other results.


Subject(s)
Head , Neutrons , Photons , Water