Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 45-50, 2022.
Article in Chinese | WPRIM | ID: wpr-904734

ABSTRACT

Objective@#To explore the clinical application value of mixed reality technology in locating perforator vessels and assisting perforator vessel dissection to harvest anterolateral thigh flaps.@*Methods@#Six patients who needed anterolateral thigh flap repair after resection of oral and maxillofacial tumors were recruited from the Department of Oral and Maxillofacial Surgery of Nanchong Central Hospital from January 2020 to January 2021. Before surgery, the CT angiography data of the lower limbs of the patients carrying the calibration points were imported into the data workstation to perform 3D reconstruction of the perforator vessels and surrounding tissues of the thigh, and the reconstruction results were imported into Microsoft HoloLens 2 glasses. During the operation, calibration was performed at the calibration point of the operative area so that the preoperative reconstruction results were superimposed on the operative area through Microsoft HoloLens 2 glasses. The clinical application value of mixed reality technology assisted perforator vessel location and anatomy of anterolateral femoral perforator flap was discussed from six aspects: whether the perforator vessel was reconstructed preoperatively, intraoperative calibration time, whether the actual position of the perforating vessels passing through the fascia lata fulcrum deviated from the preoperative reconstruction result within 1 cm, time required to harvest the flap, and whether the actual route of the perforator vessel was consistent with the reconstruction result, and whether the postoperative flap survived.@*Results @# The position and course of perforating vessels were successfully reconstructed in 6 cases before the operation. The actual course of perforating vessels during the operation was consistent with the reconstruction results. The deviation between the actual position of the perforating points and the preoperative reconstruction results was within 1 cm, which met the requirements of the actual asisting of the anterolateral thigh flap. The average time of flap harvest was (70.50 ± 7.20) min. The average calibration time was (13.33 ± 5.50) min. All flaps survived.@* Conclusions @# Mixed reality technology projects the reconstruction results of anterolateral femoral perforator vessels directly into the operative area, which provides a new method for asisting localization and anatomy of anterolateral femoral flap perforator vessels and reduces the possibility of injury to perforator vessels.

2.
Chinese Journal of Urology ; (12): 890-895, 2021.
Article in Chinese | WPRIM | ID: wpr-911144

ABSTRACT

Objective:To investigate the clinical feasibility and effectiveness of 3D visualization and mixed reality technique in the partial nephrectomy of renal tumor, and to evaluate its role in the communication between doctors and patients.Methods:82 patients with renal tumors confirmed by imaging examination including 33 patients in our hospital and 49 patients admitted to the Beijing Cancer Hospital from June 2018 to December 2020, all of whom were single tumors without local or distant metastasis, and in line with the indications of endoscopic partial nephrectomy, but without other systemic serious diseases. These patients were randomly divided into observation group (n=41) and control group (n=41). Both groups were scanned with 64-slice spiral CT before operation, while the CT images in the observation group were generated by DICOM data, modeled by three-dimensional reconstruction software and uploaded to mixed reality glasses for the preoperative planning, doctor-patient communication and intraoperative guidance. In this study, 82 patients underwent laparoscopic partial nephrectomy. Questionnaires and scales were used to compare the awareness of disease and/or satisfaction with 3D visual images between the two groups. The intraoperative time of tumor detection, operative time, renal heat ischemia time and intraoperative blood loss in 2 groups were recorded to evaluate preoperative planning and intraoperative guidance. In addition, the recovery time of gastrointestinal function, indwelling time of urinary catheter, indwelling time of drainage tube in operation area, length of hospital stays after surgery and pathological type, as well as serum creatinine level and glomerular filtration rate (GFR) value in patients at 6 months after operation were used to evaluate the postoperative recovery.Results:Before surgery, the concentrations of serum creatinine in patients with the observation group and control group were (66.8±17.5) μmol/L and (70.5±13.7) μmol/L, and the GFR were (40.8±7.6) ml/min and (38.9±6.8) ml/min, respectively. All the 82 cases were operated successfully. The number of correct responses of patients in the observation group and control group about basic kidney physiology, kidney anatomy and surgical plan was (5 vs.4), (2 vs.1), (7 vs.4), the difference among which was statistically significant ( P<0.05). In the observation group, the points of patients in understanding their own kidney, disease, specific surgical plan, and risk of surgical complications were 9.5±1.61, 9.3±0.84, 9.7±0.53, and 8.5±2.21 respectively. The tumor detection time was (35.2±5.6) min, the operation time was (100.2±20.1) min, and the renal warm ischemia time was (22.7±8.6) min in the observation group, which was significantly shorter than that in the control group (43.2±6.7) min, (123.2±23.50) min, (33.2±7.8) min. However, there was no significant difference in the amount of bleeding (103.2±22.8 ml vs.112.5±19.5 ml), postoperative recovery time of gastrointestinal function (1.7±0.8 d vs.1.8±1.2 d), indwelling time of urinary catheter (3.9±1.6 d vs.4.2±1.0 d), indwelling time of drainage tube in operation area (4.6±1.3 d vs.4.9±1.7 d), length of hospital stays (6.9±1.5 d vs.7.2±1.3 d), pathological type, and the changes of serum creatinine (10.1±19.0 vs.9.6±11.3) and the amplitude of GRF (19.4±9.5 vs.18.5±10.7) fluctuation in the affected side 6 months after operation (19.4±9.5 vs.18.5±10.7) ( P>0.05). Conclusions:The application of 3D visualization and mixed reality technology in preoperative planning and intraoperative guidance of partial nephrectomy could improve patients' cognitive understanding of renal anatomy, tumor characteristics and surgical operation, and make doctor-patient communication smoother. It can reduce the risk of surgery to a certain extent, reduce the renal heat ischemia and the operation time, and remove the tumor more accurately.

3.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 597-602, 2021.
Article in Chinese | WPRIM | ID: wpr-881227

ABSTRACT

@#Mixed reality is a new digital hologram technology after virtual reality and augmented reality, which combines the real world with the virtual world to form a new visualization environment. At present, mixed reality has been applied in various fields, but its application in medical field is still in the exploratory stage. With the rapid development of the digital age, the prospect of the combination of mixed reality and medicine is boundless. It is believed that mixed reality will bring subversive changes in medical training, disease diagnosis, doctor-patient communication, clinical diagnosis, treatment and so on in the near future. In this paper, the application of mixed reality in medicine was summarized.

SELECTION OF CITATIONS
SEARCH DETAIL