Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Journal of Forensic Medicine ; (6): 422-425, 2012.
Article in Chinese | WPRIM | ID: wpr-983771

ABSTRACT

OBJECTIVE@#To establish the method for measurement of acetonitrile in blood and urine by head-space gas chromatography.@*METHODS@#DB-ALC1 (30 m x 320 microm x 1.8 microm) and DB-ALC2 (30 m x 320 microm x 1.2 microm) capillary column were used to measure the acetonitrile in blood and urine with the isopropanol as internal standard reference.@*RESULTS@#The limits of detection of acetonitrile in both blood and urine were 0.5 microg/mL, with a linear range of 5-1000 microg/mL (r = 0.999).The accuracy of this method was 93.2%-98.0%. The RSD for the intra-day and inter-day were less than 3.7%.@*CONCLUSION@#The method is capable for measurement analysis of acetonitrile in blood and urine.


Subject(s)
Humans , Acetonitriles/urine , Chromatography, Gas/methods , Cyanides/urine , Forensic Toxicology/methods , Reproducibility of Results , Suicide, Attempted
SELECTION OF CITATIONS
SEARCH DETAIL