Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Arq. gastroenterol ; 48(1): 24-29, Jan.-Mar. 2011. ilus, tab
Article in English | LILACS | ID: lil-583754

ABSTRACT

CONTEXT: Gastroesophageal reflux disease is one of the most common digestive diseases and an important cause of distress to patients. Diagnosis of this condition can require ambulatory pH monitoring. OBJECTIVES: To determine the diagnostic yield of a wireless ambulatory pH monitoring system of 48-hours, recording to diagnose daily variability of abnormal esophageal acid exposure and its symptom association. METHODS: A total of 100 consecutive patients with persistent reflux symptoms underwent wireless pH capsule placement from 2004 to 2009. The wireless pH capsule was deployed 5 cm proximal to the squamocolumnar junction after lower esophageal sphincter was manometrically determined. The pH recordings over 48-h were obtained after uploading data to a computer from the receiver that recorded pH signals from the wireless pH capsule. The following parameters were analyzed: (1) percentual time of distal esophageal acid exposure; (2) symptom association probability related to acid reflux. The results between the first and the second day were compared, and the diagnostic yield reached when the second day monitoring was included. RESULTS: Successful pH data over 48-h was obtained in 95 percent of patients. Nearly one quarter of patients experienced symptoms ranging from a foreign body sensation to chest pain. Forty-eight hours pH data analysis was statistically significant when compared to isolated analysis of day 1 and day 2. Study on day 2 identified seven patients (30.4 percent) that would be missed if only day 1 was analyzed. Three patients (18.7 percent) out of 16 patients with normal esophageal acid exposure on both days, showed positive symptom association probability, which generated an increase in diagnostic yield of 43.4 percent. CONCLUSION: Esophageal pH monitoring with wireless capsule is safe, well tolerated, does not require sedation. The extended 48-h period of study poses an increased yield to diagnose gastroesophageal reflux disease patients.


CONTEXTO: A doença do refluxo gastroesofágico é uma das doenças digestivas mais comuns e importante causa de desconforto para os pacientes. O diagnóstico desta condição clínica pode requerer monitoramento ambulatorial do pH esofágico. OBJETIVOS: Determinar o espectro diagnóstico do sistema de monitoramento ambulatorial do pH esofágico com cápsula telemétrica por um período de 48 horas no diagnóstico da variabilidade diária da exposição ácida anormal e sua associação com sintomas. MÉTODOS: Foram incluídos 100 pacientes adultos, consecutivos, com sintomas relacionados com a doença do refluxo gastroesofágico, que realizaram pHmetria com cápsula telemétrica por 48 horas entre 2004 e 2009. A cápsula foi posicionada e implantada a 5 cm da borda superior do esfíncter esofágico inferior, definida pela manometria esofágica. Foram analisados os seguintes parâmetros: (1) tempos percentuais de exposição ácida no esôfago distal; (2) probabilidade de associação dos sintomas com o refluxo ácido. Foram comparados os resultados entre o 1º e o 2º dia de monitoramento, assim como o eventual ganho diagnóstico obtido após a inclusão do 2º dia no monitoramento. RESULTADOS: Sucesso na obtenção dos dados do pH esofágico durante 48 horas foi obtido em 95 por cento dos pacientes. Aproximadamente 25 por cento dos pacientes apresentaram sintomas relacionados à implantação da cápsula, variando entre sensação de presença de corpo estranho à dor torácica. A análise dos resultados do estudo de 48 horas mostrou-se estatisticamente significante quando comparada com as análises isoladas do dia 1 e do dia 2. O estudo do dia 2 identificou sete pacientes (30.4 por cento) que teriam sido perdidos se somente o dia 1 fosse analisado. Três pacientes (18.7 por cento) dos 16 pacientes com exposição ácida normal no esôfago distal em ambos os dias, apresentaram probabilidade de associação com o sintoma positivo, que gerou incremento no ganho diagnóstico com este método diagnóstico de 43.4 por cento. CONCLUSÕES: O monitoramento do pH esofágico com a cápsula telemétrica é seguro, bem tolerado e não requer sedação. A extensão do período de estudo para 48 horas representa significativo aumento no ganho diagnóstico em pacientes com doença do refluxo gastroesofágico.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Capsule Endoscopy/instrumentation , Esophageal pH Monitoring/instrumentation , Esophagoscopy/instrumentation , Gastroesophageal Reflux/diagnosis , Monitoring, Ambulatory/instrumentation , Capsule Endoscopy/adverse effects , Capsule Endoscopy/methods , Esophageal pH Monitoring/adverse effects , Esophagoscopy/adverse effects , Esophagoscopy/methods , Monitoring, Ambulatory/adverse effects , Monitoring, Ambulatory/methods , Retrospective Studies
2.
Rev. Assoc. Med. Bras. (1992) ; 52(6): 395-400, nov.-dez. 2006. ilus, graf
Article in Portuguese | LILACS | ID: lil-440204

ABSTRACT

OBJETIVO: Avaliar a acurácia da CGMS em pacientes diabéticos, bem como seu impacto no controle glicêmico/metabólico e possíveis complicações do método. MÉTODOS: Foram estudados 53 pacientes (47,2 por centoM/52,8 por centoF), idade: 29,74±16,38 anos, predomínio de DM1 (86,8 por cento), submetidos à monitorização contínua da glicose (CGM) (Medtronic; Northridge, CA) por 72 h. Foram analisados: glicemia capilar (GC) média e pelo sensor CGMS, coeficiente de correlação, excursões glicêmicas (CGMS versus GC), hiperglicemia pós-prandial (HPP) e hipoglicemia assintomática; complicações e conduta após a CGM. Os níveis de A1c foram medidos antes (um mês) e três meses após a CGM. RESULTADOS: A GC média durante a CGM foi 191,3±45,6 mg/dl versus 192,5±43,9 mg/dl detectada pelo sensor, com correlação altamente significativa (p=0,001). O coeficiente de correlação foi de 0,87±0,16 (VR>0,79). O CGMS detectou mais excursões glicêmicas em relação à GC (p=0,001). HPP foi evidenciada em 77,3 por cento dos casos e a hipoglicemia noturna assintomática em 54 por cento. Observou-se redução significante da A1c três meses após a CGM (p=0,001). Não houve complicações durante a CGM em 89,8 por cento dos exames. CONCLUSÃO: A CGMS mostrou-se método seguro, com baixo índice de complicações e alta acurácia nos valores glicêmicos em relação à glicemia capilar. Verificou-se alta eficácia da CGMS na detecção de excursões glicêmicas, hipoglicemia noturna assintomática e HPP, com importante impacto na redução da A1c após três meses nesse grupo de pacientes.


OBJECTIVE: To evaluate the accuracy, safety and complications of the continuous glucose monitoring system (CGMS) in diabetic patients (DM). The impact of this system on metabolic/glycemic control is still under discussion. METHODS: The 53 patients studied (47.2 percent male / 52.8 percent female), average age: 29.74±16.38 years, DM1 prevalence (86.8 percent) were submitted to 72h CGMS (Medtronic; Northridge, CA). Capillary glycemia (CG) and mean CGMS sensor's glycaemic value; correlation coefficient, glycemic excursions (CGMS vs. CG), postprandial hyperglycemia, unrecognized hypoglycemia, complications and therapeutic management after CGMS were analyzed. A1c levels were measured at baseline (1 month before) and after 3 months of the study. RESULTS: The mean capillary glucose values were 191.3±45.6 vs. 192.5±43.9mg/dl by CGMS sensor, with significant correlation (p=0.001). The correlation coefficient was 0.87± 0.16 (VR>0.79). The CGMS was significantly more efficient in the detection of glycemic excursion related to capillary glycemia (p=0.001). Postprandial hyperglycemia was identified in 77.3 percent of diabetic patients and nocturnal unrecognized hypoglycemia was detected in 54 percent. Data showed a significantly decreased A1c level, three months after the CGMS (p=0.001). No complications were registered in 89.8 percent of patients. CONCLUSION: The CGMS was confirmed to be a very safe method, with high accuracy in glycemic values and to have a low complication rate. It is a good method to identify glucose excursion, postprandial hyperglycemia and asymptomatic hypoglycemia, with a significant impact on the A1c levels of diabetic patients.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Blood Glucose/analysis , Diabetes Mellitus/blood , Monitoring, Ambulatory/standards , Blood Glucose Self-Monitoring , Capillaries , Glucose Tolerance Test , Hyperglycemia/diagnosis , Hypoglycemia/diagnosis , Monitoring, Ambulatory/adverse effects , Reference Values , Retrospective Studies
3.
Arq. bras. endocrinol. metab ; 49(6): 983-990, dez. 2005. tab, graf
Article in Portuguese | LILACS | ID: lil-420173

ABSTRACT

A avaliação do controle glicêmico no diabetes mellitus (DM) envolve tradicionalmente a observação das taxas de glicemia e hemoglobina glicada. Recentemente o Fleury - Centro de Medicina Diagnóstica implantou o exame de monitorização contínua de glicose (MCG) (Medtronic Minimed - CGMS® System GoldTM) e, neste trabalho, objetivamos descrever a experiência relacionada à realização deste exame durante o ano de 2004. Realizaram-se 141 exames neste período. Do total, 88 por cento (n= 124) pacientes eram diabéticos, sendo 99 usuários de insulina. Encontramos forte correlação entre os valores de glicose obtidos com a MCG e no sangue capilar (r= 0,926; p< 0,005). Nos diabéticos, identificou-se hipoglicemia noturna (< 50mg/dL) em 35 por cento (n= 44), padrões hiperglicêmicos (> 220mg/dL) em períodos determinados do dia em 44 por cento e hiperglicemia sustentada ao longo de toda monitorização em treze casos (10 por cento). Doze exames foram realizados para investigação de hipoglicemias em não diabéticos. Dois exames foram sugestivos de "dumping" e em um caso a MCG reforçou a hipótese de insulinoma. Ocorreram interrupções parciais das monitorizações em 15 por cento dos exames. Concluímos que a MCG é uma metodologia útil para investigação das oscilações glicêmicas, sendo uma importante ferramenta para ajuste terapêutico em pacientes com DM.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Aged, 80 and over , Blood Glucose Self-Monitoring/standards , Diabetes Mellitus/blood , Monitoring, Ambulatory/standards , Blood Glucose Self-Monitoring/adverse effects , Hyperglycemia/prevention & control , Hypoglycemia/prevention & control , Linear Models , Monitoring, Ambulatory/adverse effects , Statistics, Nonparametric , Dumping Syndrome/diagnosis , Time Factors
4.
J. pediatr. (Rio J.) ; 81(4): 293-297, jul.-ago. 2005. ilus
Article in Portuguese | LILACS | ID: lil-414399

ABSTRACT

OBJETIVO: Avaliar a acurácia, utilidade e complicacões da monitorizacão subcutânea contínua da glicemia em criancas e adolescentes com diabetes melito tipo 1 (DM1). MÉTODOS: Foram estudados retrospectivamente 16 pacientes (16,12n4,41 anos), submetidos à monitorizacão subcutânea contínua da glicemia (Medtronic; Northridge, CA, EUA) por 72 horas. Foram analisados os valores de glicemia capilar média e pelo sensor monitorizacão subcutânea contínua da glicemia; excursões glicêmicas (monitorizacão subcutânea contínua da glicemia versus. glicemia capilar); hiperglicemia pós-prandial (< 140 mg/dl); hipoglicemia noturna assintomática; complicacões (trauma, infeccão local, desconexão) e conduta terapêutica após a monitorizacão subcutânea contínua da glicemia. Os níveis de A1c foram determinados antes e 3 meses após a monitorizacão subcutânea contínua da glicemia. RESULTADOS: A glicemia capilar média durante a monitorizacão subcutânea contínua da glicemia foi de 214,3n66,5 mg/dl vs. 207,6n54,6 detectada pelo sensor, com correlacão significante (p = 0,001). O coeficiente de correlacão e erro médio absoluto foram de 0,86n0,21 e mediana de 12,6 por cento, respectivamente. A monitorizacão subcutânea contínua da glicemia mostrou-se mais eficaz na deteccão de excursões glicêmicas (p = 0,04; W = 74) em relacão à glicemia capilar em ponta de dedo. A hiperglicemia pós-prandial foi identificada em 60 por cento dos pacientes com DM1, com mediana de 157 mg/dl (< 140 mg/dl). A hipoglicemia noturna assintomática foi detectada em 46,7 por cento dos casos. A avaliacão dos níveis de A1c em oito (50 por cento) pacientes, antes e após 3 meses da monitorizacão subcutânea contínua da glicemia, mostrou reducão significante da A1c (8,18n1,5 vs. 7,28n1,3; p = 0,034) nesse grupo de pacientes. A mudanca de conduta terapêutica foi instituída em 100 por cento das criancas e adolescentes. Não houve complicacões durante o exame em 93,7 por cento dos casos. CONCLUSÕES: A monitorizacão subcutânea contínua da glicemia mostrou-se método seguro, bem tolerado, com alta acurácia nos valores glicêmicos detectados, com baixo índice de complicacões. Esse método mostrou-se eficaz na deteccão de excursões glicêmicas, hiperglicemia pós-prandial, na promocão de mudancas terapêuticas com reducão importante da A1c em criancas e adolescentes diabéticos. A eficácia desse método na identificacão da hipoglicemia assintomática ainda mostra-se indefinida na literatura.


Subject(s)
Child, Preschool , Child , Adolescent , Humans , Blood Glucose Self-Monitoring/standards , Blood Glucose/analysis , Diabetes Mellitus, Type 1/blood , Blood Glucose Self-Monitoring/adverse effects , Chi-Square Distribution , Diabetes Mellitus, Type 1/drug therapy , Evaluation Study , Hyperglycemia/prevention & control , Hypoglycemia/prevention & control , Insulin/therapeutic use , Monitoring, Ambulatory/adverse effects , Monitoring, Ambulatory/standards , Retrospective Studies , Statistics, Nonparametric
SELECTION OF CITATIONS
SEARCH DETAIL