1.
Ann Card Anaesth
;
2012 Apr; 15(2): 172-173
Article
in English
| IMSEAR
| ID: sea-139669
2.
Ann Card Anaesth
;
2010 May; 13(2): 148-153
Article
in English
| IMSEAR
| ID: sea-139517
ABSTRACT
A pacing system infection may lead to infective endocarditis and systemic sepsis. Tricuspid valve surgery may be required if the valve is severely damaged in the process of endocarditis. Although, cardiopulmonary bypass is the safe choice for performing right-heart procedures, it may carry risk of inducing systemic inflammatory response and multi-organ dysfunction. Some studies have advocated TV surgery without institution of CPB. We report tricuspid valve excision using the off-pump inflow occlusion technique in a 68-year-old man. We also describe role of intra-operative TEE as a monitoring tool at different stages of the surgical procedure. .
Subject(s)
Aged , Cardiac Surgical Procedures/instrumentation , Cardiac Surgical Procedures/methods , Coronary Artery Bypass, Off-Pump/methods , Echocardiography, Transesophageal/methods , Endocarditis, Bacterial/complications , Endocarditis, Bacterial/surgery , Humans , Male , Monitoring, Intraoperative , Sick Sinus Syndrome/surgery , Treatment Outcome , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Ultrasonography, Interventional/methods
3.
In. Timerman, Ari; Machado César, Luiz Antonio; Ferreira, Joäo Fernando Monteiro; Bertolami, Marcelo Chiara. Manual de Cardiologia: SOCESP. Säo Paulo, Atheneu, 2000. p.426-47, ilus.
Monography
in Portuguese
| LILACS, SES-SP
| ID: lil-265461