Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Adicionar filtros








Intervalo de ano
1.
Braz. j. oral sci ; 14(4): 334-340, Oct.-Dec. 2015. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: lil-797258

RESUMO

Aim: To evaluate the effects of 10% NaOCl gel application on the dentin bond strengths and morphology of resin-dentin interfaces formed by three adhesives. Methods: Two etch-and-rinseadhesives (One-Step Plus, Bisco Inc. and Clearfil Photo Bond, Kuraray Noritake Dental) and oneself-etch adhesive (Clearfil SE Bond, Kuraray Noritake Dental) were applied on dentin accordingto the manufacturers’ instructions or after the treatment with 10% NaOCl (ED-Gel, Kuraray NoritakeDental) for 60 s. For interfacial analysis, specimens were subjected to acid-base challenge andobserved by SEM to identify the formation of the acid-base resistant zone (ABRZ). For microtensilebond strength, the same groups were investigated and the restored teeth were thermocycled(5,000 cycles) or not before testing. Bond strength data were subjected to two-way ANOVA andTukey’s test (p<0.05). Results: NaOCl application affected the bond strengths for One-Step Plusand Clearfil Photo Bond. Thermocycling reduced the bond strengths for Clearfil Photo Bond andClearfil SE Bond when used after NaOCl application and One-Step Plus when used asrecommended by manufacturer. ABRZ was observed adjacent to the hybrid layer for self-etchprimer. The etch-and-rinse systems showed external lesions after acid-base challenge and noABRZ formation when applied according to manufacturer’s instructions. Conclusions:10% NaOClchanged the morphology of the bonding interfaces and its use with etch-&-rinse adhesives reducedthe dentin bond strength. Formation of ABRZ was material-dependent and the interface morphologieswere different among the tested materials.


Assuntos
Humanos , Masculino , Feminino , Colagem Dentária , Suscetibilidade à Cárie Dentária , Dentina , Adesivos Dentinários , Microscopia Eletrônica de Varredura , Hipoclorito de Sódio
2.
Rev. Assoc. Paul. Cir. Dent ; 67(4): 287-291, out.-dez. 2013. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-707535

RESUMO

Este estudo avaliou a influência de dois tipos de cerâmicas odontológicas (óxido de zircônio e dissilicato de lítio) na transmitância da luz emitida por diferentes aparelhos fotoativadores. Discos com 1 mm de espessura e 10 mm de diâmetro foram preparados a partir dos materiais restauradores indiretos: IPS e.Max Zircad (lvoclar Vivadent) e IPS e.Max (lvoclar Vivadent). Sobre os materiais protéticos foi aplicada a cerâmica à base de nanofluorapatita (IPS e.Max Ceram, Ivociar vivadent), com 1 mm de espessura. Cinco diferentes aparelhos fotoativadores foram testados: Arc Light 11 (AirTechniques), ColtoLux LED (Colténe Whaledent), Elipar Free Light 2 (3M ESPE), Astralis 10 (lvoclar Vivadent) e Ultralume 5 (Ultradent), sendo esse último utilizado no modo normal, apenas com luz azul ou luz violeta. A irradiância através dos diferentes materiais restauradores foi mensurada com um espectroradiômetro (DAS 2100, Labsphere) associado a um software especifico (Spectra Suite, Ocean Optics). Os dados foram submetidos à analise de variância de 2 fatores e teste de T ukey (p:s;O,05). A luz emitida pelo aparelho arco de plasma (Arc Light 11) mostrou maior passagem através dos materiais indiretos estudados, enquanto a luz violeta emitida pelo aparelho Ultralume 5 foi a mais bloqueada entre os aparelhos. A zircônia permitiu maior passagem de luz quando comparada ao dissilicato de lítio. Os materiais restauradores indiretos estudados apresentaram comportamentos distintos com relação à passagem de luz. O tipo de aparelho fotoativador influenciou a irradiância através dos diferentes materiais restauradores.


This study evaluated the influence of different types of restorative indirect materiais (zirconium oxide and lithium disilicate) in transmittance of light emitted by different types of curing units. Discs with 1 mm thickness and 10 mm dia meter were prepared from the indirect restorative materiais: IPS e.max ZirCAD (Ivoclar Vivadent) and IPS e.max (Ivoclar Vivadent). A nanofluorapatite ceramic (IPS e.max, Ivoclar Vivadent) was applied over theindirect materiais with 1 mm thickness. Five different light curing units were tested: Arc Light II (Air Technologies), ColtoLux LED (Colténe Whaledent), Elipar Free Light 2 (3M ESPE), Astralis 10 (Ivoclar Vivadent) and Ultralume 5 (Ultradent), which was used in regular mode, only light blue and only violet. The Irradiance through different restorative materiais was measured using a spectroradiometer (DAS 2100, Labsphere) associated with a specific software (Spectra Suite, Ocean Optics). Data were analyzed by two-way analysis of variance and Tukey test (p:s;O,05). The plasma are curing unit (Arc Light 11) showed the highest irradiance values through different restorative materiais, while the light source Ultralume 5, violet mode, showed the lowest irradiance values through different restorative materiais. The zirconia allowed higher light intensity passed through it when compared to lithium disilicate. The indirect restorative materiais tested showed distinct properties regarding the transmittance of light. Type of curing unit significantly influenced the Irradiance through different restorative materiais.


Assuntos
Materiais Dentários , Luz , Polimerização
3.
Rev. ABO nac ; 19(5): 290-296, out.-nov. 2012. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-671910

RESUMO

Introdução - Os sistemas adesivos têm evoluído e a durabilidade da união resina-dentina é um assunto importante na Odontologia Restauradora, uma vez que está diretamente relacionada com a longevidade dos procedimentos restauradores. Este estudo avaliou o efeito do tempo de armazenamento em saliva artificial na resistência de união de 4 adesivos à dentina. Material e Métodos - Vinte terceiros molares foram utilizados e divididos em 4 grupos (n=5), que corresponderam aos adesivos testados: Adper Easy Bond (EB), AdperSE Plus (SP), Adper Single Bond 2 (SB) e Clearfil SE Bond (CS). Os adesivos foram aplicados na dentina oclusal planificada e em seguida, os dentes foram restaurados com incrementos de 2 mm de resina composta. Após armazenamento em água destilada por 24 horas, os dentes restaurados foram seccionados seguindo a metodologia de microtração. Metade dos espécimes obtidos de cada dente foi armazenada em saliva artificial a 37°C por 6 meses (6ME) e a outra metade (24H) submetida ao teste de microtração. Os dados foram analisados pela ANOVA (2 fatores) e teste de Tukey (p<0,05). Resultados - Os adesivos produziram similar resistência de união à dentina nos dois tempos avaliados (p=0,7860). A resistência de união de união dos adesivos não apresentou diferença significativa entre os tempos avaliados (p=0,8454). As médias de resistência de união (DP) para os adesivos foram (MPa): EB(24H): 57,8(17,4), EB(6ME): 57,7(18,5), SP(24H): 57,9(15,5), SP(6ME): 55,9(9,6), SB(24H): 48,9(8,1), SB(6ME): 49,7(7,9), CS(24H): 60,1(21,0) e CS(6ME): 59,0(9,5). Conclusão - A resistência da união adesivo-dentina não foi afetada pelo tempo do armazenamento.


Introduction – The adhesive systems have improved and the resin-dentin bond durability is an important subject within Restorative Dentistry, since it is related to longevity of composite restorations. This study evaluated the effect of artificial saliva storage on bond strength of 4 adhesives to dentin. Material and Methods - Twenty third molars were used in this study. They were divided into 4 groups (n=5), which corresponded to adhesives tested: Adper Easy Bond (EB), Adper SE Plus (SP), Adper Single Bond 2 (SB) and Clearfil SE Bond (CS). Bonding agents were applied to flat oclusal dentin surface and the teethwere incrementally restored with composite resin. After 24 hours of water storage, the restored teeth were sectioned according to the micro-tensile bond methodology. The half of bonded beam specimens were stored in artificial saliva at 37 oC for 6 months (6ME) andthe other half (24H) was tested in tension. Data were analyzed by two-way ANOVA and Tukey test (p<0.05). Results - The results suggested that the adhesives present similar bond strength mean values to dentin in both evaluation times. (p=0.7860). The bond strengthof adhesive systems was not different between the evaluation times (p=0.8454). The bond strength means (DP) for the adhesives were (MPa): EB(24H): 57.8(17.4), EB(6ME): 57.7(18.5), SP(24H): 57.9(15.5), SP(6ME): 55.9(9.6), SB(24H): 48.9(8.1), SB(6ME): 49.7(7.9), CS(24H): 60.1(21.0) and CS(6ME): 59.0(9.5). Conclusion - The resin-dentinbond strength of the adhesives tested was not affect by storage.


Assuntos
Dentina , Adesivos Dentinários , Resistência à Tração
4.
Braz. j. oral sci ; 11(1): 76-80, jan.-mar. 2012. ilus
Artigo em Inglês | LILACS, BBO | ID: lil-638408

RESUMO

Aim: To evaluate the influence of the viscosity and curing mode on the bond strength of two resincements to dentin. Methods: Eight experimental groups were formed (n = 7) according to thedual-cure resin cements (Nexus 2 - Kerr Corp. and Variolink II - Ivoclar Vivadent), curing modes(dual-cure or self-cure) and viscosities (low and high). Resin cements were applied to pre-curedcomposite resin discs (2 mm thick, Sinfony -3M ESPE), which were fixed to bonded dentinsurfaces. The restored teeth were either light-activated (XL3000 - 3M ESPE) or allowed to selfcuring only. After 24 h, the teeth were both mesiodistally and buccolingually sectioned to obtainbonded beam specimens (0.8 mm2 cross-sectional area). Each specimen was tested in microtensilestrength at a crosshead speed of 0.5 mm/min until failure. Results: Data (in MPa) were analyzedstatistically by three-way ANOVA and Tukey’s post-hoc test (pre-set á = 0.05). No significantdifference was observed between resin cements (p=0.26) and viscosities (p=0.13), however, thecuring mode affected the BS within the viscosities (p=0.01). Statistically significant difference wasobserved for low viscosity: Nexus 2: 23.8(10.6) (dual-cure) and 16.0(5.1) (self-cure); VariolinkII: 28.7(8.7) (dual-cure) and 11.9(3.0) (self-cure). Conclusions: Light activation yielded higherbond strength for the low-viscosity versions of the resin cements.


Assuntos
Dentina , Cimentos de Resina
5.
Braz. dent. j ; Braz. dent. j;23(3): 218-222, 2012. tab
Artigo em Inglês | LILACS | ID: lil-641590

RESUMO

The purpose of this study was to evaluate the effects of adhesive primer applications on the bond strength of resin cements to cast titanium. Four adhesive primers - Metaltite, Metal Primer II, Alloy Primer and Ceramic Primer - and their respective resin cements - Bistite II DC, Link Max, Panavia F 2.0, RelyX Unicem and RelyX ARC - were tested. Cast plates were prepared from titanium ingots (n=6 specimens/cement) and had their surfaces airborne-particle abraded with Al2O3 (50 μ m). Three resin cement cylinders were built on each bonded titanium surface, using a cylindrical translucent tubing mold and were subjected to micro-shear testing. Data were analyzed statistically by two-way ANOVA and Tukey's post-hoc test (α=0.05). The application of Metal Primer II and Ceramic Primer resulted in significant higher bond strength for Link Max and RelyX Unicem resin cements, respectively, than nonuse of adhesive primers. Panavia F 2.0 and RelyX ARC yielded high bond strength means with or without adhesive primers. The use of adhesive primers might increase the bond strength to cast titanium depending on the resin cement used.


O objetivo deste estudo foi avaliar o efeito da aplicação de primers na resistência de união de cimentos resinosos ao titânio. Quatro primers - Metaltite, Metal Primer II, Alloy Primer and Ceramic Primer - e seus respectivos cimentos resinosos - Bistite II DC, Link Max, Panavia F 2.0, RelyX Unicem and RelyX ARC - foram testados. Placas de titânio foram preparadas a partir da fundição de lingotes (n=6 espécimes/cimento) e as superfícies dessas placas foram jateadas com partículas de Al2O3 (50 μ m). Três cilindros de cimento resinoso foram construídos em cada placa de titânio, utilizando moldes transparentes com formato de cilindro e foram submetidos ao teste de microcisalhamento. Os dados foram analisados pela ANOVA (dois fatores) e teste de Tukey (α=0,05). A aplicação do Metal Primer II e do Ceramic Primer resultou no aumento significativo da resistência de união para os cimentos resinosos Link Max e RelyX Unicem, respectivamente. Os cimentos Panavia F 2.0 e o RelyX ARC mostraram altos valores de resistência de união com ou sem o uso dos primers. A aplicação dos primers pode aumentar a resistência de união dos cimentos resinosos ao titânio, dependendo do tipo de cimento resinoso utilizado.


Assuntos
Ligas Dentárias/química , Colagem Dentária/métodos , Metacrilatos/química , Cimentos de Resina/química , Titânio/química , Análise de Variância , Análise do Estresse Dentário , Resistência ao Cisalhamento , Resistência à Tração
6.
Rev. bras. odontol ; 65(2): 177-180, jul.-dez. 2008. tab
Artigo em Português | LILACS, BBO | ID: lil-541823

RESUMO

O estudo avaliou a resistência de união (RU) ao esmalte e à dentina de dois novos sistemas adesivos: Tetric N-Bond (TN), que preconiza o condicionamento ácido separado e o autocondicionante Bond Force. A superfície vestibular de 24 incisivos bovinos foi desgastada para exposição do esmalte e dentina. As amostras foram alatoriamente distribuídas em quatro grupos (n=6). Três cilindros de resina composta foram obtidos por dente. Após, as amostras foram submetidas ao ensaio de microcisalhamento e as médias abalisadas estatisticamente (Anova, p<0.05). O adesivo TN apresentou valores superiores e a RU ao esmalte foi maior para os dois adesivos.


Assuntos
Animais , Bovinos , Adesivos Dentinários/normas , Esmalte Dentário , Dentina , Resistência ao Cisalhamento , Incisivo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA