Your browser doesn't support javascript.
loading
Frecuencia de hemoglobinopatías en mujeres embarazadas del programa de anemias por hematíes falciformes en Cuba / Frequency of hemoglobinopathies among pregnant women from the sickle cell anemia program in Cuba
Valdés Fraser, Yadira; Pérez Rodríguez, Jacqueline; Concepción Álvarez, Alina; Acosta Sánchez, Tatiana; Besil, Beatriz Suárez; Riviera, Dailén Llacer; Correa Jiménez, Sandra Bárbara.
  • Valdés Fraser, Yadira; Centro Nacional de Genética Médica. La Habana. CU
  • Pérez Rodríguez, Jacqueline; Centro Nacional de Genética Médica. La Habana. CU
  • Concepción Álvarez, Alina; Centro Nacional de Genética Médica. La Habana. CU
  • Acosta Sánchez, Tatiana; Centro Nacional de Genética Médica. La Habana. CU
  • Besil, Beatriz Suárez; Centro Nacional de Genética Médica. La Habana. CU
  • Riviera, Dailén Llacer; Centro Nacional de Genética Médica. La Habana. CU
  • Correa Jiménez, Sandra Bárbara; Centro Nacional de Genética Médica. La Habana. CU
Rev. cuba. hematol. inmunol. hemoter ; 37(1): e1338, ene.-mar. 2021. tab, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1251717
RESUMEN

Introducción:

Las hemoglobinopatías se consideran errores monogénicos hereditarios y están caracterizados por defectos en la molécula de hemoglobina. En Cuba, la detección prenatal de hemoglobinopatías se realiza a través de la electroforesis de hemoglobina para identificar parejas de alto riesgo. El programa brinda asesoramiento genético, diagnóstico prenatal molecular e interrupciones selectivas de fetos afectados, a solicitud de las parejas.

Objetivo:

Determinar la frecuencia de hemoglobinopatías en mujeres embarazadas residentes en Cuba.

Métodos:

Se realizó un estudio descriptivo, retrospectivo y de corte transversal para determinar la frecuencia de hemoglobinopatías en 1 342 917 mujeres embarazadas captadas en el periodo 2009-2019. El método diagnóstico de la pesquisa fue la electroforesis de hemoglobina en geles de agarosa a pH alcalino. La confirmación se realizó por electroforesis de hemoglobina en gel de agarosa a pH ácido; ambos métodos mediante la tecnología HYDRASYS.

Resultados:

La frecuencia global de embarazadas con hemoglobinopatías fue de 3,5 por ciento. Se detectó hemoglobinopatías en 47 465 mujeres; 38 698 con variante S heterocigoto, 8 706 variantes de hemoglobina C y 158 de otras variantes. Se detectaron 44 283 esposos con hemoglobinopatías, 3 099 parejas de alto riesgo y se realizaron 2 689 diagnósticos prenatales moleculares. Se confirmaron 522 fetos afectados y 382 parejas solicitaron la interrupción del embarazo. El subprograma alcanzó 99,24 por ciento de cobertura en el país.

Conclusión:

La alta frecuencia de hemoglobinopatías en Cuba justifica la importancia de continuar el subprograma de detección de portadores para prevenir la aparición de las formas graves de la enfermedad(AU)
ABSTRACT

Introduction:

Hemoglobinopathies are hereditary monogenic errors characterized by defects in the hemoglobin molecule. In Cuba, prenatal detection of hemoglobinopathies is performed by hemoglobin electrophoresis to identify high-risk couples. The program offers genetic counseling, prenatal molecular diagnosis and selective pregnancy termination in case of affected fetuses at the request of couples.

Objective:

Determine the frequency of hemoglobinopathies among pregnant women living in Cuba.

Methods:

A descriptive cross-sectional retrospective study was conducted to determine the frequency of hemoglobinopathies in 1 342 917 pregnant women recruited in the period 2009-2019. Screening was based on the diagnostic method of hemoglobin electrophoresis in alkaline pH agarose gels. Confirmation was performed with hemoglobin electrophoresis in acid pH agarose gel. Both methods used HYDRASYS technology.

Results:

Overall frequency of pregnant women with hemoglobinopathies was 3.5 percent. Hemoglobinopathies were detected in 47 465 women 38 698 with variant S heterozygote, 8 706 with variants of hemoglobin C y 158 with other variants. 44 283 husbands with hemoglobinopathies and 3 099 high-risk couples were detected, and 2 689 prenatal molecular diagnostic tests were conducted. A total 522 affected fetuses were confirmed, and 382 couples requested pregnancy termination. The subprogram achieved 99.24 percent coverage in the country.

Conclusion:

The high frequency of hemoglobinopathies in Cuba justifies the importance of continuing the carrier detection subprogram to prevent the emergence of severe forms of the disease(AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Prenatal Diagnosis / Family Characteristics / Electrophoresis / Genetic Counseling / Hemoglobinopathies / Hydrogen-Ion Concentration Type of study: Diagnostic study / Observational study / Prevalence study / Prognostic study / Risk factors / Screening study Limits: Female / Humans / Pregnancy Country/Region as subject: Caribbean / Cuba Language: Spanish Journal: Rev. cuba. hematol. inmunol. hemoter Journal subject: Allergy and Immunology / Hematology Year: 2021 Type: Article Affiliation country: Cuba Institution/Affiliation country: Centro Nacional de Genética Médica/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Prenatal Diagnosis / Family Characteristics / Electrophoresis / Genetic Counseling / Hemoglobinopathies / Hydrogen-Ion Concentration Type of study: Diagnostic study / Observational study / Prevalence study / Prognostic study / Risk factors / Screening study Limits: Female / Humans / Pregnancy Country/Region as subject: Caribbean / Cuba Language: Spanish Journal: Rev. cuba. hematol. inmunol. hemoter Journal subject: Allergy and Immunology / Hematology Year: 2021 Type: Article Affiliation country: Cuba Institution/Affiliation country: Centro Nacional de Genética Médica/CU