Your browser doesn't support javascript.
loading
Rendimiento del Kit de Chagas V2.0 IICS-UNA para el tamizaje de la enfermedad
Acosta-de Hetter, María Eugenia; Aria, Laura; Guillén, Ivalena de; Rojas, Alejandra; Infanzón, Belén; Cantero, César; Bernal, Cynthia; Peter, Kaspar.
  • Acosta-de Hetter, María Eugenia; s.af
  • Aria, Laura; s.af
  • Guillén, Ivalena de; s.af
  • Rojas, Alejandra; s.af
  • Infanzón, Belén; s.af
  • Cantero, César; s.af
  • Bernal, Cynthia; s.af
  • Peter, Kaspar; s.af
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1422116
RESUMEN
En Paraguay la enfermedad de Chagas es endémica, siendo el número de personas infectadas de aproximadamente 165.000 y la población expuesta del 30% según registros del 2012. El objetivo del trabajo fue evaluar el ELISA Chagas test IICS V2.0 para tamizaje de la enfermedad en muestras de donantes de sangre. Se realizó un estudio transversal de pruebas diagnósticas, para lo que se incluyeron 775 muestras de suero provenientes de dos bancos de sangre, a partir de cuyos resultados se calculó la sensibilidad, valores predictivos positivo, negativo y la curva ROC. También se determinó la concordancia y correlación entre el ELISA Chagas test IICS V2.0 y un ELISA comercial. De las 775 muestras de bancos de sangre analizadas se obtuvo una sensibilidad del 99%, especificidad de 96%, VPP 96%, VPN 99% y un índice kappa igual a 0,95 (0,93-0,97) Error Estándar (EE) 0.01 y p>00001 y el área ROC igual a 0,9835. Con respecto a la concordancia con el test comercial, el índice kappa fue de 0,926 IC95% (0,888-0,976), p=0,00001 y el coeficiente de correlación r=0,971 IC95% (0,962-0.978) p=0,0001. Las concordancias obtenidas fueron muy buenas con respecto a la serología de las muestras de banco de sangre como la comparada con el test comercial, pudiendo utilizarse el kit de Chagas IICS V2 para el tamizaje de la enfermedad.
ABSTRACT
In Paraguay, Chagas disease is endemic, with approximately 165,000 infected people and 30% of the exposed population according to 2012 records. The objective of this study was to evaluate the ELISA Chagas test IICS V2.0 for screening of the disease in blood donor samples. We carried out a cross-sectional study of diagnostic tests, including 775 serum samples from two blood banks, and then calculating sensitivity, positive and negative values and the ROC curve. We also determined the concordance and correlation between the ELISA Chagas test IICS V2.0 and commercial ELISA. In the 775 blood bank samples analyzed, the Chagas ELISA test IICS V2.0 obtained a sensitivity of 99%, specificity of 96%, PPV 96%, NPV 99% and a kappa index equal to 0.95 (0.93-0.97) Standard Error (SE) 0.01 and p>0.0001 and the ROC area equal to 0.9835. Regarding the concordance with the commercial test, the kappa index was 0.926 CI95% (0.888-0.976), p=0.00001 and the correlation coefficient r=0.971 CI95%(0.962-0.978) p=0.0001.The concordances obtained were very good with respect to the serology of the blood bank samples as compared to the commercial test, allowing the use of the Chagas IICS V2 kit for the disease screening.

Full text: Available Index: LILACS (Americas) Type of study: Observational study / Prevalence study / Prognostic study / Risk factors / Screening study Language: Spanish Journal: Mem. Inst. Invest. Cienc. Salud (Impr.) Journal subject: Ciˆncias da Sa£de / Medicine / Pesquisa Year: 2022 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Type of study: Observational study / Prevalence study / Prognostic study / Risk factors / Screening study Language: Spanish Journal: Mem. Inst. Invest. Cienc. Salud (Impr.) Journal subject: Ciˆncias da Sa£de / Medicine / Pesquisa Year: 2022 Type: Article