Proteína C reactiva y su progresión en el tiempo para la detección de las fugas anastomóticas / C-reactive protein and its progression over time for the detection of anastomotic leaks
Rev. colomb. cir
; 38(2): 283-288, 20230303. tab, fig
Article
in Es
| LILACS
| ID: biblio-1425201
Responsible library:
CO113
RESUMEN
Introducción. Las fugas anastomóticas son una complicación común y crítica en cirugía gastrointestinal, por lo que su identificación y tratamiento temprano son necesarios para evitar resultados adversos. El uso convencional con un valor límite de la proteína C reactiva ha demostrado una utilidad limitada. El objetivo de este estudio fue determinar la utilidad de la medición seriada de la proteína C reactiva en la detección de fugas anastomóticas. Métodos. Revisión prospectiva de base de datos retrospectiva de pacientes sometidos a cirugía abdominal mayor con al menos una anastomosis intestinal. Se midió la proteína C reactiva al tercer y quinto día posoperatorio. Las complicaciones se categorizaron según la clasificación de Clavien-Dindo. La precisión diagnóstica fue evaluada por el área bajo la curva. Resultados. Se incluyeron 157 pacientes, el 52 % mujeres. La edad promedio fue de 63,7 años. El mayor número de cirugías correspondió a gastrectomía (36,3 %), resección anterior de recto (15,3 %) y hemicolectomía derecha (13,4 %). El 25,5 % tuvieron alguna complicación postoperatoria y el 32,5 % (n=13) presentaron fuga en la anastomosis. El aumento de la proteína C reactiva tuvo un área bajo la curva de 0,918 con un punto de corte de aumento en 1,3 mg/L, sensibilidad de 92,3 % (IC95% 78 100) y una especificidad de 92,4 % (IC95% 88 96). Conclusiones. El aumento de 1,3 mg/L en la proteína C reactiva entre el día de la cirugía y el quinto día fue un predictor preciso de fugas anastomóticas en pacientes con cirugía abdominal mayor
ABSTRACT
Introduction. Anastomotic leaks are a common and critical complication in gastrointestinal surgery. Their identification and early treatment are necessary to avoid adverse results, and conventional use with a cutoff value of C-reactive protein has shown limited utility. The objective of this study was to determine the usefulness of serial measurement of C-reactive protein in the detection of anastomotic leaks. Methods. Prospective review of a retrospective database of patients undergoing major abdominal surgery with at least one intestinal anastomosis. C-reactive protein was measured on the third and fifth postoperative days. Complications were classified according to the Clavien-Dindo classification. Diagnostic accuracy was evaluated by the area under the curve.Results. 157 patients were included, 52% were females. The average age was 63.7 years. The largest number of surgeries corresponded to gastrectomies (36.3%), anterior resection of the rectum (15.3%) and right hemicolectomies (13.4%). 25.5% had some postoperative complication and 32.5% (n=13) had anastomosis leaks. The increase in C-reactive protein had an area under the curve of 0.918 with an increase cut-off point of 1.3 mg/L, sensitivity of 92.3% (95% CI 78-100) and specificity of 92.4%. (95% CI 88-96). Conclusions. The 1.3 mg/L increase in C-reactive protein between the day of surgery and the fifth day was an accurate predictor of anastomotic leaks in patients with major abdominal surgery
Key words
C-reactive protein; anastomosis quirúrgica; anastomotic leak; clinical evolution; complicaciones posoperatorias; digestive system surgical procedures; evolución clínica; fuga anastomótica; gastrectomy; gastrectomía; postoperative complications; procedimientos quirúrgicos del sistema digestivo; proteína C-reactiva; surgical anastomosis
Full text:
1
Index:
LILACS
Main subject:
Protein C
/
Anastomosis, Surgical
/
Anastomotic Leak
Type of study:
Diagnostic_studies
/
Prognostic_studies
/
Systematic_reviews
Limits:
Humans
Language:
Es
Journal:
Rev. colomb. cir
Journal subject:
CIRURGIA GERAL
Year:
2023
Type:
Article