RESUMO

Introdução:

Instrumentos rotatórios em níquel-titânio reduzem erros processuais e o tempo requerido para finalização do preparo do canal radicular. O objetivo deste estudo foi avaliar as ocorrências de transporte apical e aberrações nos canais produzidas com diferentes instrumentos utilizados para a criação de trajetória-guia (“glide path”) no preparo de canais curvos limas manuais K e limas rotatórias em níquel-titânio PathFile e Mtwo. Material e

Métodos:

Os canais mesiais de 45 primeiros e segundos molares inferiores (com ângulos de curvatura entre 25 e 35 graus) foram selecionados para o estudo. As amostras foram divididas aleatoriamente em três grupos de 15 canais cada e o preparo foi realizado por um endodontista utilizando limas manuais de aço inoxidável tipo K #10-15-20, conicidade 0,02 (grupo M), instrumentos rotatórios PathFile #13-16-19, conicidade 0,02 (grupo PF) e instrumentos rotatórios Mtwo #10/04- #15/05- #20/06 (grupo MT). Foi utilizada a técnica da dupla radiografia digital, pré e pós-instrumentação, para avaliar se ocorreu transporte apical e/ou aberrações na morfologia dos canais. Por meio de uma análise computadorizada e com o auxílio de magnificação, as imagens inicial e final do eixo central foram comparadas por meio de sua sobreposição. Os espécimes foram analisados por 3 avaliadores, cuja calibração foi checada por meio do teste de concordância de Kendall.

Resultados:

Não ocorreu transporte apical nem aberração na morfologia do canal em 100% dos dentes, portanto nenhuma análise estatística foi realizada.

Conclusão:

Tanto os instrumentos rotatórios PathFile e Mtwo quanto os instrumentos manuais utilizados para a criação de trajetória-guia não exerceram influência sobre a ocorrência de transporte apical nem promoveram aberrações na morfologia dos canais .
ABSTRACT

Introduction:

Nickel-titanium rotary instruments reduce procedural errors and the time required to finish root canal preparation.The goal of this study was to evaluate the occurrences of apical transportation and canal aberrations produced with different instruments used to create a glide path in the preparation of curved root canals, namely manual K files and PathFile and Mtwo nickel-titanium rotary files.

Methods:

The mesial canals of 45 mandibular first and second molars (with curvature angles between 25 and 35 degrees) were selected for this study. The specimens were divided randomly into three groups with 15 canals each, and canal preparation was performed by an endodontist using #10-15-20 K-type stainless steel manual files (Group M), #13-16-19 PathFile rotary instruments (Group PF), and #10-15-20 Mtwo rotary instruments (Group MT). The double digital radiograph technique was used, pre- and post-instrumentation, to assess whether apical transportation and/or aberration in root canal morphology occurred. The initial and final images of the central axis of the canals were compared by superimposition through computerized analysis and with the aid of magnification. The specimens were analyzed by 3 evaluators, whose calibration was checked using the Kendall agreement test.

Results:

No apical transportation or aberration in root canal morphology occurred in any of the teeth; therefore, no statistical analysis was conducted.

Conclusion:

Neither the manual instruments nor the PathFile or Mtwo rotary instruments used to create a glide path had any influence on the occurrence of apical transportation or produced any canal aberration