Your browser doesn't support javascript.
loading
Efectividad del cálculo del lente intraocular por Pentacam y por el método de Maloney en pacientes con cirugía refractiva corneal previa / Effectiveness of the calculation of the intraocular lens by Pentacam and by Maloney's method in patients with previous refractive corneal surgery
Pérez Candelaria, Eneida de la Caridad; Cárdenas Díaz, Taimi; Montero Díaz, Eric; Ramos Pereira, Yanay; Guerra Almaguer, Michel; Cuan Aguilar, Yoriel.
  • Pérez Candelaria, Eneida de la Caridad; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Cárdenas Díaz, Taimi; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Montero Díaz, Eric; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Ramos Pereira, Yanay; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Guerra Almaguer, Michel; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Cuan Aguilar, Yoriel; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
Rev. cuba. oftalmol ; 30(1): 0-0, ene.-mar. 2017. tab
Article in Spanish | LILACS | ID: biblio-901342
RESUMEN

Objetivo:

comparar los resultados visuales de los pacientes con cirugía refractiva corneal, operados de catarata e implante de lente intraocular, calculado por el método de Maloney y por Pentacam.

Métodos:

se realizó un estudio descriptivo, prospectivo y longitudinal en 41 ojos de 31 pacientes con catarata y antecedentes de cirugía refractiva corneal, divididos aleatoriamente en dos grupos (1 y 2) con 23 y 18 ojos respectivamente, para calcular el poder corneal por el método de Maloney y por Pentacam, respectivamente, necesario para el cálculo de la lente intraocular a implantar.

Resultados:

la mayoría de los pacientes tenía antecedentes de queratotomía radial (90,24 pr ciento). El poder dióptrico medio de la lente mediante el método de Maloney fue de 18,8 ± 4,20, mientras que con la lectura queratométrica, medida a 4,0 mm del Pentacam, fue de 18 ± 4,20, con una diferencia media de 0,80 dioptrías ( p= 0,000) asociada a la prueba de los rangos con signo de Wilcoxon. El componente esférico posoperatorio promedio fue de -0,49 ± 0,65 dioptrías en el grupo 1 y de -0,57 ± 0,685 en el grupo 2, con una diferencia entre la esfera observada y la esperada de 0,16 y 0,15 dioptrías respectivamente (p= 0,906), asociada a la prueba U de Mann-Whitney. quedaron emétropes un 43,48 por ciento del grupo 1 y un 50 por ciento del grupo 2.

Conclusiones:

ambos métodos brindan resultados visuales favorables, pero el cálculo de la lente intraocular a partir de las lecturas queratométricas aportadas por el Pentacam ofrece mejores resultados visuales para los pacientes con antecedentes de cirugía refractiva corneal(AU)
ABSTRACT

Objective:

to compare the visual results of patients operated from cataract and with intraocular lens implantation through corneal refractive surgery and estimated by Maloney's method and Pentacam camera.

Methods:

prospective, longitudinal and descriptive study conducted in 41 eyes from 31 patients with cataract and history of refractive corneal surgery. They were randomly assigned to two groups (1 and 2) with 23 and 18 eyes, respectively in order to estimate the corneal power of the intraocular lens to be implanted through Maloney's method and Pentacam camera.

Results:

most of patients had history of radial keratotomy (90.24 percent). The average dioptric power of the lens according to Maloney's method was 18.8 ± 4.20 whereas the kerametric reading, measured at 4.0 mm from Pentacam was 18 ± 4.20, with a mean difference of 0.80 dioptries ((p= 0,000) associated to Wilcoxon's sign range test. The average postoperative spheral component was -0.49 ± 0.65 D in group 1 and -0.57 ± 0.685 in group 2, with a difference between the observed and the expected sphere of 0.16 and 0.15 dioptries, respectively (p= 0.906), associated to Mann-Whitney's U test. In group 1, 43.48 percent and in group 2, 50 percent remained emetropes.

Conclusions:

Both methods provide favorable visual results, but the calculation of the intraocular lens power through the keratometric readings by Pentacam offers better visual results for patients with a history of refractive corneal surgery(AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Keratotomy, Radial / Corneal Topography / Lens Implantation, Intraocular Type of study: Controlled clinical trial / Observational study / Risk factors Limits: Humans Language: Spanish Journal: Rev. cuba. oftalmol Journal subject: Ophthalmology Year: 2017 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Keratotomy, Radial / Corneal Topography / Lens Implantation, Intraocular Type of study: Controlled clinical trial / Observational study / Risk factors Limits: Humans Language: Spanish Journal: Rev. cuba. oftalmol Journal subject: Ophthalmology Year: 2017 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU