Evaluación de un modelo de capacitación preclínica en el uso de los localizadores electrónicos del foramen, por alumnos de grado de endodoncia / Evaluation of a preclinical training model of undergraduatestudents in the use of electronic foramen locatorsin endodontics
Cantarini, Carlos; Macchi, Ricardo Luis; Goldberg, Fernando.
  • Cantarini, Carlos; USAL/AOA. Escuela de Odontología. Cátedra de Endodoncia I. Buenos Aires. AR
  • Macchi, Ricardo Luis; Universidad de Buenos Aires. Facultad de Odontología. Buenos Aires. AR
  • Goldberg, Fernando; USAL/AOA. Escuela de Odontología. Buenos Aires. AR
Rev. Asoc. Odontol. Argent ; 105(2): 36-41, jun. 2017. tab, ilus
Article in Spanish | LILACS | ID: biblio-908055
RESUMEN

Objetivo:

evaluar la capacitación y los resultados del uso de localizadores del foramen en un curso preclínico destinado a alumnos de grado de la Escuela de Odontología de la Universidad del Salvador / AsociaciónOdontológica Argentina, entre 2005 y 2016. Materiales y

métodos:

Se emplearon 2053 incisivos, caninos y premolares inferiores y superiores humanos extraídos. Los dientes se montaron de modo tal que sus raí-ces quedasen sumergidas en una solución salina, utilizando dos

métodos:

a) tubos de plástico, b) modelos que simulan la arcada dentaria. Se realizaron los accesos coronarios al conducto radicular de forma convencional y se prepararonlos tercios cervical y medio. Para determinar la longitud de trabajo, se introdujo una lima tipo K de calibre acorde con el conducto radicular, ajustando en ella el terminal del localizador electrónico del foramen. El terminal labial se sumergió en la misma solución salina en que se encontraban las raíces dentarias. En la mayoría de los dientes se empleó, parala determinación, la técnica de ingreso, y en los restantes, la de regreso. El nivel de penetración se estableció con la señal lumínica y/o sonora de 0,5. Se ajustó el tope del instrumento al borde de referencia y se obtuvo una imagen radiográfica periapical del diente evaluado. Se retiró el instrumento del conducto radicular y se midió desde su punta hasta el tope respectivo. Las medidas obtenidas con los localizadores electrónicos del foramen se compararon con las conductometrías radiográficas, considerando una tolerancia de 0,5 mm. Para la evaluación estadística, se tomó en cuenta el cálculo de intervalo deconfianza (95 por ciento) realizado a partir de la distribución binomial.

Resultados:

De los 2053 dientes en los cuales se determinó la longitud de trabajo, 1743 (84,9 por ciento) fueron consideradas medidas correctas, y 310 (15,1 por ciento), incorrectas...
ABSTRACT

Aim:

To assess the training process and results of the useof electronic apex locators in an

Aim:

To assess the training process and results of the useof electronic apex locators in an undergraduate preclinicalcourse for students from the University del Salvador / AsociaciónOdontológica Argentina between 2005 and 2016.Materials and

methods:

Two thousand fifty threeextracted human incisors, canines, maxillary and mandibularbicuspid teeth were used. The teeth were mounted withthe roots submerged in saline solution using two

methods:

a) plastic tubes, b) models simulating the dental arch. Conventionalcoronal access to the root canal was performedand the cervical and middle portions of the root canal wereflared. To determine the working length a K-file with a caliberaccording to the root canal was selected for each tooth andintroduced in the root canal with the clip adjusted in the file.The labial clip was immersed in the model saline solution. Inthe majority of the teeth the advanced and withdrawal techniquewas employed. The level of penetration was establishedusing the light and/or the acoustic signal at 0.5. Then, the rubberstop was adjusted to the reference line and a radiographwas obtained. The instrument was removed and measuredfrom its tip to the rubber stop. The measurements obtainedwith the electronic apex locators were compared with thoseobtained from the X rays considering a tolerance of 0.5 mm.For the statistical evaluation, 95% confidence intervals werecalculated using the binomial distribution.

Results:

Out of 2053 teeth in which the working lengthwas determined, 1743 (84.9%) were considered correct measurementsand 310 (15.1%) incorrects...
Subject(s)

Search on Google
Index: LILACS (Americas) Main subject: Tooth Apex / Education, Predental / Endodontics / Odontometry Type of study: Evaluation studies Limits: Humans Language: Spanish Journal: Rev. Asoc. Odontol. Argent Journal subject: Dentistry Year: 2017 Type: Article Affiliation country: Argentina Institution/Affiliation country: AOA+AR / Universidad de Buenos Aires/AR

Similar

MEDLINE

...
LILACS

LIS

Search on Google
Index: LILACS (Americas) Main subject: Tooth Apex / Education, Predental / Endodontics / Odontometry Type of study: Evaluation studies Limits: Humans Language: Spanish Journal: Rev. Asoc. Odontol. Argent Journal subject: Dentistry Year: 2017 Type: Article Affiliation country: Argentina Institution/Affiliation country: AOA+AR / Universidad de Buenos Aires/AR