Anestesia para implante de marca-passo em paciente adulto com ventrículo único não-operado: relato de caso / Anesthesia for pacemaker implant in an adult patient with unoperated univentricular heart: case report
Hobaika, Adriano Bechara de Souza; Procópio, André Luís Pontes; Pereira, Marcelo Luiz Souza; Coimbra, Aristóteles Pereira; Fernandes, Magda Lourenço; Pires, Kleber Costa de Castro.
  • Hobaika, Adriano Bechara de Souza; Santa Casa de Belo Horizonte. Belo Horizonte. BR
  • Procópio, André Luís Pontes; Santa Casa de Belo Horizonte. Belo Horizonte. BR
  • Pereira, Marcelo Luiz Souza; Santa Casa de Belo Horizonte. Belo Horizonte. BR
  • Coimbra, Aristóteles Pereira; Santa Casa de Belo Horizonte. Belo Horizonte. BR
  • Fernandes, Magda Lourenço; Santa Casa de Belo Horizonte. Belo Horizonte. BR
  • Pires, Kleber Costa de Castro; Santa Casa de Belo Horizonte. Belo Horizonte. BR
Rev. bras. anestesiol ; 57(1): 90-93, jan.-fev. 2007.
Article in Portuguese | LILACS | ID: lil-440121
RESUMO
JUSTIFICATIVA E OBJETIVOS: Ventrículo único é anormalidade rara encontrada em cerca de 1 por cento dos pacientes com cardiopatia congênita. Somente 11 casos de pacientes com ventrículo único não-operado e idade acima de 50 anos foram relatados na literatura. Este trabalho teve como objetivo descrever a conduta anestésica em paciente com ventrículo único para implante de marca-passo. RELATO DO CASO: Paciente do sexo feminino, 47 anos, com presença de dupla via de entrada do ventrículo esquerdo, L-transposição de grandes artérias e estenose subpulmonar, sem correção cirúrgica prévia, foi agendada para implante de marca-passo cardíaco definitivo seqüencial de duas câmaras. Ao MAPA apresentava bloqueio atrioventricular de segundo grau e uma freqüência cardíaca média de 45 bpm. Os exames pré-operatórios mostravam hematócrito de 57 por cento, coagulograma normal, função ventricular preservada. A monitorização constou de oxímetro de pulso, ECG nas derivações D II e V5, PIA, capnógrafo e analisador de gases. Um marca-passo temporário transcutâneo foi disponibilizado no caso de bradicardia intensa. A anestesia foi induzida com fentanil (0,25 mg), etomidato (20 mg) e atracúrio (35 mg). Quatro minutos após a indução, a freqüência cardíaca diminuiu para 30 bpm, sendo administrado 1 mg de atropina, com reversão da bradicardia. A anestesia foi mantida com sevoflurano a 2,5 por cento, ar 60 por cento e oxigênio 40 por cento. O estado hemodinâmico e a saturação de oxigênio permaneceram estáveis. A paciente foi encaminhada à unidade de terapia intensiva estável e extubada ao final do procedimento. CONCLUSÕES: A conduta anestésica para implante de marca-passo em paciente de 47 anos com dupla via de entrada do ventrículo esquerdo e estenose subpulmonar não-operada foi adequada, haja vista que permitiu a realização do procedimento indicado.
ABSTRACT
BACKGROUND AND OBJECTIVES: Single ventricle is a rare abnormality, affecting 1 percent of the patients with congenital cardiopathy. Only 11 cases of patients with unoperated univentricular heart older than 50 years were reported in the literature. The aim of this report was to describe the anesthetic conduct in a patient with univentricular heart undergoing pacemaker implant. CASE REPORT: A female patient, 47 years old, with double outlet left ventricle, L-transposition of the great vessels, and pulmonary stenosis, without prior surgical correction, was scheduled for definitive implant of a sequential dual-chamber pacemaker. The ABPM demonstrated second degree atrioventricular block and a mean heart rate of 45 bpm. Preoperative exams showed a hematocrit of 57 percent, normal coagulation studies, and preserved ventricular function. Monitoring consisted of pulse oxymeter, ECG on D II and V5, IBP, capnograph, and gas analyzer. A temporary transcutaneous pacemaker was available in case of severe bradycardia. Anesthesia was induced with fentanyl (0.25 mg), etomidate (20 mg), and atracurium (35 mg). Four minutes after anesthetic induction, the heart rate decreased to 30 bmp and 1 mg of atropine was administered with reversal of the bradycardia. Anesthesia was maintained with 2.5 percent sevoflurane, 60 percent room air, and 40 percent oxygen. Hemodynamic parameters and oxygen saturation remained stable. The patient was transferred to the intensive care unit in stable condition and extubated at the end of the procedure. CONCLUSIONS: The anesthetic conduct for pacemaker implant in a 47-year old patient with non-operated double outlet left ventricle and pulmonary stenosis was appropriate, since it allowed the procedure to be performed.
RESUMEN
JUSTIFICATIVA Y OBJETIVOS: Ventrículo único es una anormalidad rara encontrada en aproximadamente 1 por ciento de los pacientes con cardiopatía congénita. Solamente 11 casos de pacientes con ventrículo único no operado y edad por encima de los 50 años, fueron relatados en la literatura. Este trabajo tiene el objetivo de describir la conducta anestésica en paciente con ventrículo único para implante de marcapaso. RELATO DEL CASO: Paciente del sexo femenino, 47 años, con doble vía de entrada del ventrículo izquierdo, L-transposición de grandes arterias y estenosis subpulmonar, sin corrección quirúrgica previa, se marcó consulta para implante de marcapaso cardíaco definitivo secuencial de dos cámaras. En el MAPA presentaba bloqueo atrioventricular de segundo grado y una frecuencia cardiaca promedio de 45bpm. Los exámenes preoperatorios mostraban hematócrito de 57 por ciento, coagulograma normal, función ventricular preservada. La monitorización constó de oxímetro de pulso, ECG en las derivaciones D II y V5, PIA, capnógrafo y analizador de gases. Un marcapaso temporal transcutáneo quedó a disposición para el caso de bradicardia intensa. La anestesia se indujo con fentanil (0.25 mg), etomidato (20 mg) y atracurio (35 mg). Cuatro minutos después de la inducción, la frecuencia cardiaca disminuyó para 30bpm siendo administrado 1 mg de atropina, con reversión de la bradicardia. La anestesia se mantuvo con sevoflurano a 2.5 por ciento, aire 60 por ciento y oxígeno 40 por ciento. El estado hemodinámico y la saturación de oxígeno permanecieron estables. La paciente fue llevada a la unidad de terapia intensiva estable y extubada al final del procedimiento. CONCLUSIONES: La conducta anestésica para implante de marcapaso en paciente de 47 años con doble vía de entrada del ventrículo izquierdo y estenosis subpulmonar no operada, fue adecuada, ya que permitió la realización del procedimiento indicado.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Pacemaker, Artificial / Cardiac Surgical Procedures / Heart Ventricles / Anesthesia Limits: Female / Humans Language: Portuguese Journal: Rev. bras. anestesiol Journal subject: Anesthesiology Year: 2007 Type: Article Affiliation country: Brazil Institution/Affiliation country: Santa Casa de Belo Horizonte/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Pacemaker, Artificial / Cardiac Surgical Procedures / Heart Ventricles / Anesthesia Limits: Female / Humans Language: Portuguese Journal: Rev. bras. anestesiol Journal subject: Anesthesiology Year: 2007 Type: Article Affiliation country: Brazil Institution/Affiliation country: Santa Casa de Belo Horizonte/BR