Avaliação isocinética em pacientes submetidos à artroplastia total de joelho / Isokinetic evaluation of patients submitted to total knee arthroplasty
Acta ortop. bras
; Acta ortop. bras;17(1): 22-25, 2009. graf, tab
Article
in En, Pt
| LILACS
| ID: lil-509089
Responsible library:
BR734.1
RESUMO
OBJETIVOS:
Tem-se afirmado que a via de acesso minimamente invasiva na artroplastia total de joelho (ATJ) por não agredir o músculo quadríceps femoral permite reabilitação mais precoce. A fim de verificar a influência da preservação do aparelho extensor no ato cirúrgico, avaliou-se a força da musculatura extensora e flexora do joelho em pacientes submetidos à ATJ por duas vias de acesso diferentes.MATERIAIS E MÉTODOS:
Este estudo comparou, no período de janeiro de 2005 a julho de 2006, os valores de torque máximo e de trabalho total obtidos por dinamometria isocinética aos seis meses de pós-operatório. Foram avaliados 12 indivíduos submetidos a ATJ por via de acesso minimamente invasiva e 8 indivíduos submetidos a ATJ por via de acesso transquadricipital.RESULTADOS:
A análise estatística dos valores de torque máximo e de trabalho total absolutos e corrigidos pelo peso corporal não demonstrou diferença entre os dois grupos.CONCLUSÃO:
Não há diferença de força da musculatura extensora e flexora do joelho aos seis meses de cirurgia.ABSTRACT
OBJECTIVE:
In total knee arthroplasty, the minimally-invasive approach has been claimed to enable earlier rehabilitation because it spares the femoral quadriceps muscle. To check the influence of preserving the extensor apparatus during surgery, the strength of knee extension and flexion muscles was evaluated in patients submitted to total knee arthroplasty with different approaches. MATERIALS ANDMETHODS:
The values of maximum torque and total work obtained by isokinetic dynamometry six months after surgery were compared for the Minimally invasive surgery group constituted of 12 individuals submitted to total knee arthroplasty by the minimally invasive surgical approach and the Control group, constituted of eight patients submitted to total knee arthroplasty by the transquadricipital approach, between January 2005 and July 2006.RESULTS:
Statistical analysis of the absolute values for maximum torque and total work adjusted for body weights did not show differences between both groups.CONCLUSION:
There was no difference in the extension and flexion strength of the knee muscles six months after surgery.Key words
Full text:
1
Index:
LILACS
Main subject:
Arthroplasty, Replacement, Knee
/
Muscle Strength
/
Muscle Strength Dynamometer
/
Knee Prosthesis
Type of study:
Observational_studies
Limits:
Female
/
Humans
Language:
En
/
Pt
Journal:
Acta ortop. bras
Journal subject:
ORTOPEDIA
Year:
2009
Type: