Your browser doesn't support javascript.
loading
Viability study of a multiplex diagnostic platform for Chagas disease
Foti, Leonardo; Fonseca, Bruna de Paula Fonseca e; Nascimento, Lilian Dias; Marques, Christiane de Fatima Silva; Silva, Edmilson Domingos da; Duarte, Cesar Augusto Barros; Probst, Christian M; Goldenberg, Samuel; Pinto, Antônio Gomes; Krieger, Marco Aurélio.
Affiliation
  • Foti, Leonardo; Fiocruz. Instituto Carlos Chagas. Curitiba. BR
  • Fonseca, Bruna de Paula Fonseca e; Fiocruz. Biomanguinho. Laboratório de Tecnologia. Diagnóstica. Rio de Janeiro. BR
  • Nascimento, Lilian Dias; Fiocruz. Biomanguinho. Laboratório de Tecnologia. Diagnóstica. Rio de Janeiro. BR
  • Marques, Christiane de Fatima Silva; Fiocruz. Biomanguinho. Laboratório de Tecnologia. Diagnóstica. Rio de Janeiro. BR
  • Silva, Edmilson Domingos da; Fiocruz. Biomanguinho. Laboratório de Tecnologia. Diagnóstica. Rio de Janeiro. BR
  • Duarte, Cesar Augusto Barros; Fiocruz. Instituto Carlos Chagas. Curitiba. BR
  • Probst, Christian M; Fiocruz. Instituto Carlos Chagas. Curitiba. BR
  • Goldenberg, Samuel; Fiocruz. Instituto Carlos Chagas. Curitiba. BR
  • Pinto, Antônio Gomes; Fiocruz. Biomanguinho. Laboratório de Tecnologia. Diagnóstica. Rio de Janeiro. BR
  • Krieger, Marco Aurélio; Fiocruz. Instituto Carlos Chagas. Curitiba. BR
Mem. Inst. Oswaldo Cruz ; 104(supl.1): 136-141, July 2009. graf
Article in En | LILACS | ID: lil-520900
Responsible library: BR1.1
ABSTRACT
A new multiplex assay platform was evaluated to detect Trypanosoma cruzi infection using the recombinant antigensCRA, FRA, CRAFRA fusion and parasite lysate. The antigens presented different sensitivity and specificity in a singleplex test when compared to a serial dilution of two pools comprising 10 positive serum samples and one pool of 10 negative samples. The recombinant protein CRA presented lower sensitivity (55%) in contrast to the 100% specificity and sensitivity of FRA, CRAFRA and T. cruzi lysate. These antigens also showed good results in a duplex test and the duplex test with CRAFRA/T. cruzi lysate showed better performance with 100% specificity and sensitivity, as well as a lower cut-off value in comparison to the other duplex test, FRA/T. cruzi lysate. Hence, when the antigens were used in duplex format, both tests showed decreased cut-off values and no interference between different bead sets, resulting in increasing sensitivity and specificity. The results of these multiplex tests show that they could be an alternative to singleplex detection for Chagas disease, and also indicate the necessity of using multiplex diagnostic tools to increase the sensitivity and specificity for diagnostic tests. Emerging data from the T. cruzi genome and from its ORFeome project will also allow the identification of new antigens for this disease detection application.
Subject(s)
Key words
Full text: 1 Index: LILACS Main subject: Immunoassay / Chagas Disease / Antigens, Protozoan Type of study: Diagnostic_studies / Observational_studies / Prognostic_studies Limits: Humans Language: En Journal: Mem. Inst. Oswaldo Cruz Journal subject: MEDICINA TROPICAL / PARASITOLOGIA Year: 2009 Type: Article
Full text: 1 Index: LILACS Main subject: Immunoassay / Chagas Disease / Antigens, Protozoan Type of study: Diagnostic_studies / Observational_studies / Prognostic_studies Limits: Humans Language: En Journal: Mem. Inst. Oswaldo Cruz Journal subject: MEDICINA TROPICAL / PARASITOLOGIA Year: 2009 Type: Article