Ruído em uma Unidade de Terapia Intensiva neonatal: mensuração e percepção de profissionais e pais / Noise in a neonatal Intensive Care Unit: measurement and perception of professionals and parents
Aurélio, Fernanda Soares; Tochetto, Tania Maria.
  • Aurélio, Fernanda Soares; Universidade Federal de Santa Maria. Santa Maria. BR
  • Tochetto, Tania Maria; Universidade Federal de Santa Maria. Programa de Pós-Graduação em Distúrbios da Comunicação Humana. Santa Maria. BR
Rev. paul. pediatr ; 28(2): 162-169, jun. 2010. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-551687
RESUMO

OBJETIVO:

Conhecer a percepção dos profissionais atuantes em Unidade de Terapia Intensiva Neonatal e dos pais dos recém-nascidos internados sobre o ruído existente, além de compará-la aos níveis de ruído mensurados.

MÉTODOS:

Por meio de questionário, investigou-se a percepção dos profissionais que atuam na unidade, bem como a dos pais dos recém-nascidos internados, quanto ao ruído existente no ambiente. Os níveis sonoros das três salas e do corredor da unidade foram registrados 24 horas/dia, por nove dias em cada local, com dosímetro Quest 400, e analisados pelo software QuestSuíteMR. Para comparar os níveis de ruído nos diferentes locais, aplicaram-se os testes de Kruskal-Wallis e Mann-Whitney, sendo significante p<0,05.

RESULTADOS:

Nas salas de cuidados intensivos e intermediários, no isolamento e no corredor da unidade foram registrados níveis médios de ruído de 64,8, 62,1, 63,8 e 61,9dBA, respectivamente, sendo diferentes entre si (p<0,001). Os profissionais da saúde consideraram o ruído presente e intenso e os pais, moderado. Só os primeiros julgam ruidoso o próprio comportamento. Os profissionais da saúde acreditam que tanto os recém-nascidos quanto as pessoas que trabalham nesse ambiente podem ser prejudicados pelo ruído, enquanto os pais acreditam que não. Todos os grupos julgam possível reduzir tal ruído.

CONCLUSÕES:

A opinião sobre a intensidade do ruído diferiu entre os profissionais da saúde e os pais dos recém-nascidos. Houve maior concordância entre o nível de ruído mensurado e a percepção do mesmo pelos profissionais da saúde.
ABSTRACT

OBJECTIVE:

To study the perception about environmental noise of professionals and parents of neonates assisted in a Neonatal Intensive Care Unit (NICU), and to compare the findings with the measured noise levels.

METHODS:

The perception of parents and professionals that work in the NICU in relation to the presence of noise was evaluated by a questionnaire. Sound levels in three rooms and in the corridor of that environment were registered 24 hours/day during 9 days by the Quest Q-400 Noise Dosimeter and analyzed by QuestSuíteMR software. Kruskal-Wallis e Mann-Whitney tests were used to compare the noise levels in different places, being significant p<0.05.

RESULTS:

The average noise levels in the intensive, intermediary care, isolation rooms and in the corridor of the unit were 64.8, 62.1, 63.8 and 61.9dBA, respectively (p<0.001). Health professionals qualified the noise as present and intense, but parents evaluated the noise as moderate. Health professionals judged their own behaviors as noisy, and parents believe that they do not contribute to the existent noise at the place. Health professionals believed that newborns and professionals who work in the NICU may be injured by the noise, but this was not true for parents. All groups considered possible to reduce noise.

CONCLUSIONS:

The opinion about noise intensity differed significantly among health professionals and parents. Health professionals were more coherent about NICU's measured and perceived noise levels.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Intensive Care Units, Neonatal / Noise Measurement / Noise Limits: Humans / Infant, Newborn Language: English / Portuguese Journal: Rev. paul. pediatr Journal subject: Pediatrics Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Santa Maria/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Intensive Care Units, Neonatal / Noise Measurement / Noise Limits: Humans / Infant, Newborn Language: English / Portuguese Journal: Rev. paul. pediatr Journal subject: Pediatrics Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Santa Maria/BR