Avaliação da influência do comprimento do implante em prótese fixa implantodentossuportada, pelo método dos elementos finitos / Influence of implant length in combined tooth-to-implant supported prosthesis through finite elements analysis
Lanza, Marcos Daniel S; Rocha, Wellington M. dos S; Lanza, Lincoln Dias; Lemos, Eduardo Souza; Takenaka, Satoshi; Lanza, Marcos Dias.
  • Lanza, Marcos Daniel S; Universidade de São Paulo. FOB. Bauru. BR
  • Rocha, Wellington M. dos S; Universidade de São Paulo. FOB. Bauru. BR
  • Lanza, Lincoln Dias; Universidade de São Paulo. FOB. Bauru. BR
  • Lemos, Eduardo Souza; UFMG. Faculdade de Odontologia. Belo Horizonte. BR
  • Takenaka, Satoshi; UFMG. Faculdade de Odontologia. Belo Horizonte. BR
  • Lanza, Marcos Dias; Universidade de São Paulo. FOB. Bauru. BR
ImplantNews ; 7(6): 821-827, 2010. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-599215
RESUMO
Os implantes osseointegrados utilizados para reabilitação de edentulismo total mostram um elevado grau de previsibilidade terapêutica. Entretanto, surgiu a necessidade de extrapolar as alternativas de tratamento com implantes para pacientes parcialmente edêntulos. Diante disso, vários estudos têm sido direcionados para a possibilidade ou não de unir tais implantes a dentes naturais, visto que o comportamento biomecânico dessas duas estruturas apresentam peculiaridades distintas. A partir dos métodos de elementos finitos (MEF), foram modelados dois modelos visando à simulação do comportamento mecânico de uma prótese fixa de união rígida entre dente natural e implante osseointegrado. Em um modelo o implante tinha 10 mm de comprimento e em outro modelo 6 mm de comprimento. Uma carga de 100 N, distribuída uniformemente foi aplicada em todo o conjunto para simular a mastigação funcional e posterior análise das tensões principais SEQV (Von Mises). Na análise quantitativa, pode-se observar que na prótese contendo o implante de 10 mm, as tensões máximas SEQV foram menores em relação ao implante de 6 mm, porém, com localizações semelhantes. Com base nos resultados obtidos pelo programa, podemos concluir que a utilização de implante curto é mais crítica ao sistema.
ABSTRACT
Osseointegrated implants used for total rehabilitation of edentulous show a high degree of predictability therapy. However, the need to extrapolate treatment options with implants for partially edentulous patients. Given that several studies have been focused on the possibility or not to join such implants to natural teeth as the biomechanical behavior of these two structures have distinct peculiarities. Two models were constructed aiming to simulate the behavior of a fixed rigid connection between natural tooth and osseointegrated implants. In one model, the implant was 10 mm in height, whereas in the other the length was 6mm. A load of 100N was applied, evenly distributed across the assembly simulating mastication for further analysis of the principal stresses SEQV (Von Mises). Based on quantitative analysis it was seen in the first model that maximum generated stresses were slightly lower than in the second model under similar locations. Based on the results, one can conclude that the use of short implants can be more harmful to the system.
Subject(s)

Search on Google
Index: LILACS (Americas) Main subject: Biomechanical Phenomena / Dental Implants / Finite Element Analysis / Denture, Partial Type of study: Prognostic study Language: Portuguese Journal: ImplantNews Journal subject: Dentistry Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: UFMG/BR / Universidade de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS

Search on Google
Index: LILACS (Americas) Main subject: Biomechanical Phenomena / Dental Implants / Finite Element Analysis / Denture, Partial Type of study: Prognostic study Language: Portuguese Journal: ImplantNews Journal subject: Dentistry Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: UFMG/BR / Universidade de São Paulo/BR