Amplatzer vascular Plug II (AVP II) es un dispositivo oclusor autoexpandible, indicado para oclusiones arteriales o venosas en la vasculatura periférica. Objetivo:
Describir nuestra experiencia clínica inicial con el AVP II, en el cierre percutáneo del conducto arterioso permeable pequeño.Métodos:
Analizamos retrospectivamente, siete pacientes sometidos a oclusión percutánea del conducto arterioso. El AVP II se eligió con un diámetro mayor a 50% del diámetro mínimo del conducto arterioso.Resultados:
Los pacientes evidenciaron un conducto arterioso con un diámetro mínimo de 1.5 ± 1.4 (intervalo 0.8 a 4.7mm). Se logró un implante exitoso y con adecuada oclusión angiográfica en seis pacientes. Un paciente fue enviado a cirugía. Sólo observamos una complicación mayor. El ecocardiograma transtorácico a las 24 horas, confirmó la oclusión completa en estos pacientes. El seguimiento fue de 10.6 ± 9.1 meses.Conclusiones:
El AVP II, en este grupo de pacientes mostró ser seguro y efectivo para el cierre percutáneo del conducto arterioso.ABSTRACT
The Amplatzer vascular Plug II (AVP II) is a self-expanding occluder device, indicated for arterial and venous occlusion in the peripheral circulation. Objective:
To describe our initial clinical experience with the AVP II, in the percutaneous closure of small patent ductus arteriosus.Method:
We retrospectively analyzed seven patients who underwent percutaneous closure of patent ductus arteriosus. The AVP II was chosen with a diameter greater than 50% of the minimum diameter of the ductus arteriosus.Results:
Patients showed a ductus arteriosus with a diameter of 1.5 ± 1.4 (range 0.8 - 4.7mm). Successful implant was achieved with adequate angiographic occlusion in 6 patients. One patient was sent to surgery. We only found a major complication. Transthoracic echocardiography at 24 hours, confirmed the complete occlusion in this patients. The follow-up was 10.6 ± 9.1 months.Conclusion:
The AVP II in this group of patients was shown to be safe and effective for percutaneous closure of patent ductus arteriosus.Key words
Full text:
1
Index:
LILACS
Main subject:
Ductus Arteriosus, Patent
/
Septal Occluder Device
Type of study:
Observational_studies
Limits:
Child, preschool
/
Female
/
Humans
/
Infant
/
Male
Language:
Es
Journal:
Arch. cardiol. Méx
Journal subject:
CARDIOLOGIA
Year:
2011
Type:
Article