RESUMO
JUSTIFICATIVA E OBJETIVOS:
Avaliar a incidência de infecções nosocomiais associadas aos dispositivos invasivos permite comparar as infecções associadas aos cuidados em saúde (IACS) entre as unidades de terapia intensiva (UTI) de diferentes hospitais e unidades do mesmo hospital. MATERIAL EMÉTODOS:
De janeiro de 2007 a dezembro de 2010, um estudo de vigilância retrospectivo foi realizado para identificar infecções nosocomiais, taxas de infecções relacionadas a dispositivos e agentes causadores na UTI de anestesiologia. As IACS foram definidas de acordo com os critérios do Centro de Controle e Prevenção de Doenças (CDC) e as infecções relacionadas aos dispositivos invasivos definidas de acordo com os critérios do Sistema Nacional de Vigilância de Infecções Nosocomiais (NNIS).RESULTADOS:
Durante dois anos, 939 pacientes em um universo de 7.892 pacientes/dia foram avaliados. As taxas de IACS foram de 53% em 2007, 29,15% em 2008, 28,85% em 2009 e 16,62% em 2010. A IACS mais comum foi infecção da corrente sanguínea. A taxa de infecção de tecido mole e pele foi a segunda. Entre os pacientes com infecções nosocomiais, os agentes causadores mais comuns foram Gram (-) 56,68%, Gram (+) 31,02% e candidíase 12,3%.CONCLUSÕES:
A incidência de IACS na UTI de nosso hospital foi alta, em comparação com as taxas turcas globais obtidas no Refik Saydam Center em 2007. Quando as taxas de infecções relacionadas aos dispositivos foram comparadas entre 2007 e 2008, foram maiores em 2007. A taxas de infecções relacionadas aos dispositivos em 2008 foram reduzidas abaixo da média nacional por causa das medidas de controle de infecção. Como a taxa de infecções relacionada ao cateter urinário ainda permanece alta, devemos exercer esforços contínuos para o controle das infecções.ABSTRACT
BACKGROUND AND OBJECTIVES:
Evaluating the incidence of nosocomial and invasive device-related infections enables the comparison of the health care associated infection (HAI) between the intensive care units of different hospitals and different units in the same hospital. MATERIAL ANDMETHODS:
A retrospective surveillance study was performed to identify nosocomial infections, device-related infections rates, and causal agents from January 2007 through December 2010 in the Anesthesiology Intensive care unit (ICU). HAI were defined according to the CDC (Centers for Disease Control and Prevention) criteria, and invasive device-related infections were defined according to National Nosocomial Infection Surveillance System (NNIS) criteria.RESULTS:
During a two-year period, 939 patients were analyzed throughout a total of 7,892 patientdays. The rates of HAI were 53% in 2007, 29.15% in 2008, 28.85% in 2009 while 16.62% in 2010. Most common HAI was blood stream infection. The rate of soft tissue and skin infection was the second most common. Overall, the most common agents were Gram(-) 56.68 %, Gram(+) 31.02% and Candida spp 12.3% among patients with nosocomial infections.CONCLUSIONS:
The incidence of HAI in the ICU of our hospital was high, compared to the Turkish overall rates obtained at the Refik Saydam Center in 2007. When the rates of device-related infections between 2007 and 2008 were compared, they were higher in 2007. The rates of devicerelated infections were diminished in 2008 to below-national mean rates by infection control measures. Since the rate of urinary catheter-related infections are still high, we should exert continuous efforts for infection control.RESUMEN
JUSTIfiCATIVA Y OBJETIVOS:
La evaluación de la incidencia de las infecciones nosocomiales asociadas con los dispositivos invasivos, permite comparar las infecciones relacionadas con la asistencia a la sanidad (IRAS) entre las UCIs de diferentes hospitales y las unidades del mismo hospital. MATERIAL YMÉTODOS:
De enero de 2007 a diciembre de 2010, un estudio de vigilancia retrospectivo fue realizado para identificar infecciones nosocomiales, tasas de infecciones relacionadas con los dispositivos y agentes causantes en la unidad de cuidados intensivos (UCI) de anestesiología. Las IRAS se definieron de acuerdo con los criterios del Centro de Control y Prevención de Enfermedades (CDC) y las infecciones relacionadas con los dispositivos invasivos definidas de acuerdo con los criterios del Sistema Nacional de Vigilancia de Infecciones Nosocomiales (NNIS).RESULTADOS:
Durante dos años, se evaluaron 939 pacientes dentro de un universo de 7.892 pacientes/día. Las tasas de IRAS alcanzaron el umbral del 53% en 2007, 29,15% en 2008, 28,85% en 2009 y 16,62% en 2010. La IRAS más frecuente fue la infección de la corriente sanguínea. La tasa de infección de tejido suave y de la piel fue la segunda. Entre los pacientes con infecciones nosocomiales, los agentes causantes más a menudo encontrados fueron Gr (-) 56,68%, Gr (+) 31,02% y la candidiasis 12,3%.CONCLUSIONES:
La incidencia de IRAS en la UCI de nuestro hospital fue alta en comparación con las tasas turcas globales obtenidas en el Refik Saydam Center en 2007. Cuando las tasas de infecciones relacionadas con los dispositivos se compararon entre 2007 y 2008, fueron mayores en el 2007. Las tasas de infecciones relacionadas con los dispositivos en 2008 quedaron por debajo del promedio nacional a causa de las medidas de control de infección. Como la tasa de infecciones relacionada con el catéter urinario todavía permanece alta, debemos esforzarnos más en el sentido de controlar las infecciones.Key words
Full text:
1
Index:
LILACS
Main subject:
Cross Infection
/
Intensive Care Units
Type of study:
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
/
Screening_studies
Limits:
Humans
Language:
Pt
Journal:
Rev. bras. anestesiol
Journal subject:
ANESTESIOLOGIA
Year:
2013
Type:
Article