Your browser doesn't support javascript.
loading
Detection of horizontal root fracture using four different protocols of cone-beam computed tomography
SALINEIRO, Fernanda Cristina Sales; PINHEIRO, Lucas Rodrigues; SANTOS JÚNIOR, Oséas dos; CAVALCANTI, Marcelo Gusmão Paraiso.
Affiliation
  • SALINEIRO, Fernanda Cristina Sales; Universidade de São Paulo. School of Dentistry. Department of Stomatology. São Paulo. BR
  • PINHEIRO, Lucas Rodrigues; Universidade de São Paulo. School of Dentistry. Department of Stomatology. São Paulo. BR
  • SANTOS JÚNIOR, Oséas dos; Universidade de São Paulo. School of Dentistry. Department of Stomatology. São Paulo. BR
  • CAVALCANTI, Marcelo Gusmão Paraiso; Universidade de São Paulo. School of Dentistry. Department of Stomatology. São Paulo. BR
Braz. oral res. (Online) ; 29(1): 1-6, 2015. tab, ilus
Article in En | LILACS | ID: lil-777179
Responsible library: BR1.1
ABSTRACT
The purpose of this study was to analyze four different cone-beam computed tomography (CBCT) protocols to identify horizontal root fractures (HRF) in endodontically treated teeth, with or without the presence of a metallic post. Thirty extracted single-rooted human premolars were treated endodontically. Afterwards, an observer induced a horizontal fracture in 15 teeth. Each tooth was inserted in an empty mandibular socket and submitted to a computed tomography scan taken with and without the metallic post. The acquisition followed four different protocols, with different fields of view (FOV) and voxel sizes, as follows FOV 6X16 cm/0.2 mm voxel; FOV 6X16 cm/0.25 mm voxel; FOV 8X8 cm/0.2 mm voxel; FOV 8X8 cm/0.25 mm voxel. Two observers checked all the acquisitions within a two-week interval, and the values of sensitivity, specificity, accuracy and kappa were calculated. The sensitivity, specificity and accuracy values were better for the 8X8 cm/0.2 mm and 16X6 cm/0.25 mm protocols, ranging from 0.60 to 0.86 and 0.53 to 0.80, respectively. The intra- and interobserver concordance ranged from 0.65 to 0.72. The protocols where FOV and voxel were proportional showed better results. The 8x8 cm/0.2 mm protocol had the least interference from the metallic artifact. All four protocols showed a decline in values in the presence of the metallic artifact.
Subject(s)
Key words

Full text: 1 Index: LILACS Main subject: Tooth Fractures / Tooth Root / Tooth, Nonvital / Cone-Beam Computed Tomography Type of study: Diagnostic_studies / Prognostic_studies Limits: Humans Language: En Journal: Braz. oral res. (Online) Journal subject: ODONTOLOGIA Year: 2015 Type: Article / Project document

Full text: 1 Index: LILACS Main subject: Tooth Fractures / Tooth Root / Tooth, Nonvital / Cone-Beam Computed Tomography Type of study: Diagnostic_studies / Prognostic_studies Limits: Humans Language: En Journal: Braz. oral res. (Online) Journal subject: ODONTOLOGIA Year: 2015 Type: Article / Project document