Your browser doesn't support javascript.
loading
Utilidad de la monitorización de los colgajos microquirúrgicos / Utility of monitoring microvascular flaps
Rappoport, Daniel; Madrid, Arturo; Capdeville, Felipe; Valdés, Fabio.
Affiliation
  • Rappoport, Daniel; Universidad de Chile. Santiago. CL
  • Madrid, Arturo; Clínica Alemana de Santiago. Departamento de Cirugía y Oncología. Santiago. CL
  • Capdeville, Felipe; Clínica Alemana de Santiago. Departamento de Cirugía y Oncología. Santiago. CL
  • Valdés, Fabio; Universidad de Chile. Santiago. CL
Rev. chil. cir ; 68(5): 345-348, oct. 2016. ilus, tab
Article in Es | LILACS | ID: lil-797343
Responsible library: CL1.1
RESUMEN

Objetivo:

Evaluar el uso de una sonda Doppler para verificar la permeabilidad y el flujo de la anastomosis en colgajos microquirúrgicos. Material y

método:

Serie descriptiva prospectiva de los pacientes en los cuales se realizó reconstrucción con colgajo microquirúrgico en la Clínica Alemana entre marzo de 2013 y marzo de 2015, en los cuales se utilizó un monitor Doppler arterial postanastomótico (Coock® Swartz Doppler probe).

Resultados:

Se registraron 20 pacientes con colgajos microquirúrgicos. Se realizaron 10 colgajos antebraquiales, 7 fíbulas (4 con testigo cutáneo y 3 sin), 2 anterolaterales de muslo y uno recto abdominal. Se realizaron 6 reexploraciones en pabellón. En un caso hubo sospecha tanto clínica como por el cambio en la señal del Doppler; en 4 solo sospecha clínica, y en uno solo por cambio en la señal Doppler. Los hallazgos fueron edema del colgajo en un paciente y 5 hematomas. No hubo pérdida de colgajos. Se utilizó el monitor Doppler por un promedio de 9,5 días.

Conclusión:

Este método de evaluación no reemplaza a la observación cínica, pero representa una herramienta más para la toma de decisiones en el postoperatorio de este tipo de reconstrucciones en cabeza y cuello.
ABSTRACT

Aim:

To evaluate Doppler probe to assure the flow through the anastomoses at free flaps used in head and neck surgery. Material and

method:

Descriptive prospective series, of every patient that receive a free flap reconstruction at Clinica Alemana between March 2013 and March 2015, in which a Doppler monitor (Coock® Swartz Doppler probe) on the arterial anastomoses was used.

Results:

20 patients with free flaps were recorded. 10 radial flaps, 7 fibulas (4 with a skin paddle and 3 without), 2 antero lateral thigh flaps and 1 abdominis rectus flap. 6 reexplorations were done. In one case the suspicion was clinical, with change in the Doppler signal, 4 patients just clinical suspicion and 1 just because a change in the Doppler signal. The findings were flap edema in 1 patient and 5 hematomas. We didn’t loss any flap. The Doppler monitor was used for an average of 9.5 days.

Conclusion:

The Doppler monitor doesn’t replace the clinical observation but represents another tool for the decision making during the post operative period in this kind of head and neck reconstructions.
Subject(s)
Key words

Full text: 1 Index: LILACS Main subject: Postoperative Care / Ultrasonography, Doppler / Monitoring, Physiologic Type of study: Observational_studies / Prognostic_studies Limits: Female / Humans / Male Language: Es Journal: Rev. chil. cir Journal subject: CIRURGIA GERAL Year: 2016 Type: Article

Full text: 1 Index: LILACS Main subject: Postoperative Care / Ultrasonography, Doppler / Monitoring, Physiologic Type of study: Observational_studies / Prognostic_studies Limits: Female / Humans / Male Language: Es Journal: Rev. chil. cir Journal subject: CIRURGIA GERAL Year: 2016 Type: Article