Your browser doesn't support javascript.
loading
Analysis of temperature rise on the root surface during continuous wave of condensation technique / 대한치과보존학회지
Article in Ko | WPRIM | ID: wpr-111388
Responsible library: WPRO
ABSTRACT
This study was conducted to evaluate the temperature rise on the root surface while the root canal is being obturated using continuous wave of condensation technique. Maxillary central incisor was prepared for repeated canal obturation. Ten thermocouples (Omega Engineering Inc., Stanford, USA) were placed at 1 mm increment from the anatomical root apex. The real temperature of Buchanan plugger was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan and the root surface temperature was recorded during obturation at 150degrees C, 200degrees C, 250degrees C and 300degrees C temperature settings of System B HeatSource (Model 1005, Analytic technologies, Redmond, WA, USA). After completion of the temperature recording, the dentinal-cementum thickness at each sites was measured. The data were analyzed using one-way ANOVA followed by Scheffe' s test and linear regression test. The results were as follows. 1. When the temperature was set at 150degrees C, 200degrees C, 250degrees C and 300degrees C on the digital display of System B HeatSource, the real temperature of the plugger at the 1mm point from the tip revealed 130.82+/-2.96degrees C, 158.00+/-5.26degrees C, 215.92+/-6.91degrees C and 249.88+/-3.65degrees C respectively. 2. The position of 8 mm from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.01). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was 2.37+/-0.09degrees C at 150degrees C setting, 3.11+/-0.12degrees C at 200degrees C setting, 3.93+/-0.09degrees C at 250degrees C setting and 5.69+/-0.15degrees C at 300degrees C setting respectively. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at 150degrees C, 200degrees C, 250degrees C and 300degrees C temperature settings on digital temperature display of System B HeatSource.
Subject(s)
Key words
Full text: 1 Index: WPRIM Main subject: Linear Models / Dental Pulp Cavity / Incisor Language: Ko Journal: Journal of Korean Academy of Conservative Dentistry Year: 2003 Type: Article
Full text: 1 Index: WPRIM Main subject: Linear Models / Dental Pulp Cavity / Incisor Language: Ko Journal: Journal of Korean Academy of Conservative Dentistry Year: 2003 Type: Article