The Effectiveness of Visual Field C10-2 in the Early Detection of Glaucoma with Parafoveal Scotoma
Journal of the Korean Ophthalmological Society
; : 321-326, 2017.
Article
in Ko
| WPRIM
| ID: wpr-179983
Responsible library:
WPRO
ABSTRACT
PURPOSE:
To identify the correspondence between the central sensitivity of several visual field (VF) tests and ganglion cell inner plexiform layer (GC-IPL) thickness in early glaucoma patients with parafoveal scotoma.METHODS:
Fifty-seven eyes from 57 patients with glaucomatous optic neuropathy and parafoveal scotoma were analyzed using the standard automated perimetry (SAP) C10-2 test, the SAP C24-2 test, and the frequency doubling technology perimetry (FDT) C24-2 test. The correlation between the VF central sensitivity and the GC-IPL thickness from macular scans via optical coherence tomography was analyzed.RESULTS:
The central sensitivity was 27.51 ± 5.43 dB, 27.39 ± 5.05 dB, and 22.09 ± 5.08 dB for SAP C24-2, SAP C10-2, and FDT C24-2, respectively. Mean GC-IPL thickness was 70.2 ± 8.5 µm. Using regression analysis, the value of log R² between the logarithmic central sensitivity and GC-IPL thickness was 0.498, and the linear R2 between the antilogarithmic central sensitivity and GC-IPL thickness in SAP C10-2 was 0.486, and both were statistically significant (p < 0.05). This relationship was stronger in early glaucoma patients compared to late glaucoma patients using SAP C10-2.CONCLUSIONS:
The structure-function relationship between GC-IPL thickness and central sensitivity was better with SAP C10-2, especially in early glaucoma patients, compared to other VF modalities.Key words
Full text:
1
Index:
WPRIM
Main subject:
Scotoma
/
Visual Fields
/
Optic Nerve Diseases
/
Glaucoma
/
Ganglion Cysts
/
Tomography, Optical Coherence
/
Visual Field Tests
Type of study:
Diagnostic_studies
/
Screening_studies
Limits:
Humans
Language:
Ko
Journal:
Journal of the Korean Ophthalmological Society
Year:
2017
Type: