Your browser doesn't support javascript.
loading
A prospective multicenter parallel-controlled trial of TIVOLI biodegradable-polymer-based sirolimus-eluting stent compared to ENDEAVOR zotarolimus-eluting stent for the treatment of coronary artery disease: 8-month angiographic and 2-year clinical follow-up results / 中华医学杂志(英文版)
Chinese Medical Journal ; (24): 811-816, 2011.
Article in English | WPRIM | ID: wpr-239942
ABSTRACT
<p><b>BACKGROUND</b>Available drug-eluting stents (DES) have achieved great success in reducing restenosis rates. Recently, investigators have demonstrated that the durable polymer carrier plays a significant role in DES-related hypersensitive reaction and delays vessel healing. TIVOLI stent is a novel sirolimus-eluting coronary stent with biodegradable coating containing sirolimus and polylactic-co-glycolic acid (PLGA) polymer. The present study sought to evaluate the effectiveness and safety of the TIVOLI biodegradable-polymer-based sirolimus-eluting stent in treating patients with coronary artery disease.</p><p><b>METHODS</b>A prospective, multicenter clinical trial comparing TIVOLI biodegradable coated sirolimus-eluting stent with ENDEAVOR zotarolimus-eluting stent was conducted in 324 patients (TIVOLI group 168 patients; ENDEAVOR group 156 patients) at 12 centers in China to demonstrate the non-inferiority of in-stent late loss with TIVOLI stent compared to ENDEAVOR stent in subjects with a maximum of two de novo native coronary artery lesions (lesion length ≤ 40 mm, reference vessel diameter 2.25-4.00 mm). The primary end point was angiographic in-stent late loss at 8-month. The secondary end points were clinical outcomes at 2 years, including major adverse cardiac events (cardiac death, myocardial infarction, or target-lesion revascularization) and stent thrombosis.</p><p><b>RESULTS</b>Angiographic late lumen loss at 8 months in the TIVOLI group was superior to the ENDEAVOR group (in-stent (0.25 ± 0.33) mm vs. (0.57 ± 0.55) mm, diff (95%CI) -0.23 (-0.32, -0.14), P < 0.0001; in-segment (0.25 ± 0.33) mm vs. (0.42 ± 0.55) mm, diff (95%CI) -0.13 (-0.23, -0.02), P = 0.0083). The rate of in-stent binary restenosis at 8 months was reduced from 8.6% in the ENDEAVOR group to 2.9% in the TIVOLI group (P = 0.0229). Compared to ENDEAVOR stent, TIVOLI stent resulted in a significant reduction in target-lesion revascularization (4.2% vs. 9.6%, P = 0.0495) at 2 years. The two-year major adverse cardiac events (MACE) rate was lower for the TIVOLI group, but not significantly different (6.6% vs. 10.9%, P = 0.1630).</p><p><b>CONCLUSIONS</b>TIVOLI was superior to ENDEAVOR stent with respect to late lumen loss at 8 months, and it yielded both lower rates of angiographic binary restenosis at 8 months and target lesion revascularization (TLR) at 2 years. The MACE rate at 2 years was comparable in both groups.</p>
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: Polymers / Therapeutics / Coronary Artery Disease / Angioplasty, Balloon, Coronary / Chemistry / Treatment Outcome / Coronary Angiography / Sirolimus / Therapeutic Uses / Drug Therapy Type of study: Controlled clinical trial Limits: Aged / Female / Humans / Male Language: English Journal: Chinese Medical Journal Year: 2011 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Polymers / Therapeutics / Coronary Artery Disease / Angioplasty, Balloon, Coronary / Chemistry / Treatment Outcome / Coronary Angiography / Sirolimus / Therapeutic Uses / Drug Therapy Type of study: Controlled clinical trial Limits: Aged / Female / Humans / Male Language: English Journal: Chinese Medical Journal Year: 2011 Type: Article