Your browser doesn't support javascript.
loading
Non-fluoroscopic navigation systems for radiofrequency catheter ablation for supraventricular tachycardia reduce ionising radiation exposure
Singap. med. j ; Singap. med. j;: 390-395, 2016.
Article in En | WPRIM | ID: wpr-276708
Responsible library: WPRO
ABSTRACT
<p><b>INTRODUCTION</b>The use of non-fluoroscopic systems (NFS) to guide radiofrequency catheter ablation (RFCA) for the treatment of supraventricular tachycardia (SVT) is associated with lower radiation exposure. This study aimed to determine if NFS reduces fluoroscopy time, radiation dose and procedure time.</p><p><b>METHODS</b>We prospectively enrolled patients undergoing RFCA for SVT. NFS included EnSiteTM NavXTM or CARTO® mapping. We compared procedure and fluoroscopy times, and radiation exposure between NFS and conventional fluoroscopy (CF) cohorts. Procedural success, complications and one-year success rates were reported.</p><p><b>RESULTS</b>A total of 200 patients over 27 months were included and RFCA was guided by NFS for 79 patients; those with atrioventricular nodal reentrant tachycardia (AVNRT), left-sided atrioventricular reentrant tachycardia (AVRT) and right-sided AVRT were included (n = 101, 63 and 36, respectively). Fluoroscopy times were significantly lower with NFS than with CF (10.8 ± 11.1 minutes vs. 32.0 ± 27.5 minutes; p < 0.001). The mean fluoroscopic dose area product was also significantly reduced with NFS (NSF: 5,382 ± 5,768 mGy*cm2 vs. CF: 21,070 ± 23,311 mGy*cm2; p < 0.001); for all SVT subtypes. There was no significant reduction in procedure time, except for left-sided AVRT ablation (NFS: 79.2 minutes vs. CF: 116.4 minutes; p = 0.001). Procedural success rates were comparable (NFS: 97.5% vs. CF: 98.3%) and at one-year follow-up, there was no significant difference in the recurrence rates (NFS: 5.2% vs. CF: 4.2%). No clinically significant complications were observed in both groups.</p><p><b>CONCLUSION</b>The use of NFS for RFCA for SVT is safe, with significantly reduced radiation dose and fluoroscopy time.</p>
Subject(s)
Key words
Full text: 1 Index: WPRIM Main subject: Radiation Dosage / Radiation, Ionizing / Therapeutics / Tachycardia, Atrioventricular Nodal Reentry / Tachycardia, Supraventricular / Fluoroscopy / Prospective Studies / Treatment Outcome / Catheter Ablation / Methods Type of study: Observational_studies Limits: Adolescent / Adult / Aged / Aged80 / Child / Female / Humans / Male Language: En Journal: Singap. med. j Year: 2016 Type: Article
Full text: 1 Index: WPRIM Main subject: Radiation Dosage / Radiation, Ionizing / Therapeutics / Tachycardia, Atrioventricular Nodal Reentry / Tachycardia, Supraventricular / Fluoroscopy / Prospective Studies / Treatment Outcome / Catheter Ablation / Methods Type of study: Observational_studies Limits: Adolescent / Adult / Aged / Aged80 / Child / Female / Humans / Male Language: En Journal: Singap. med. j Year: 2016 Type: Article